Uzbekistan Digital Health Platform - Integrations
0.1.0 - ci-build Uzbekistan флаг

Uzbekistan Digital Health Platform - Integrations - Локальная сборка (v0.1.0), построенная FHIR (HL7® FHIR® Стандартные инструменты сборки. Смотрите каталог опубликованных версий

Профиль типа данных: - Подробные описания

Определения для observation-birth профиль типа данных

Рекомендации по толкованию содержимого этой таблицы можно найтиздесь-- no content: do not translate #97 --

0. Observation
Определение

Measurements and simple assertions made about a patient, device or other subject.

КороткийMeasurements and simple assertions
Комментарии

Used for simple observations such as device measurements, laboratory atomic results, vital signs, height, weight, smoking status, comments, etc. Other resources are used to provide context for observations such as laboratory reports, etc.

Контроль0..*
Модификаторfalse
Требуется поддержкаfalse
Summaryfalse
Альтернативные именаVital Signs, Measurement, Results, Tests
Инвариантыdom-2: If the resource is contained in another resource, it SHALL NOT contain nested Resources (contained.contained.empty())
dom-3: If the resource is contained in another resource, it SHALL be referred to from elsewhere in the resource or SHALL refer to the containing resource (contained.where((('#'+id in (%resource.descendants().reference | %resource.descendants().ofType(canonical) | %resource.descendants().ofType(uri) | %resource.descendants().ofType(url))) or descendants().where(reference = '#').exists() or descendants().where(ofType(canonical) = '#').exists() or descendants().where(ofType(canonical) = '#').exists()).not()).trace('unmatched', id).empty())
dom-4: If a resource is contained in another resource, it SHALL NOT have a meta.versionId or a meta.lastUpdated (contained.meta.versionId.empty() and contained.meta.lastUpdated.empty())
dom-5: If a resource is contained in another resource, it SHALL NOT have a security label (contained.meta.security.empty())
dom-6: A resource should have narrative for robust management (text.`div`.exists())
obs-6: dataAbsentReason SHALL only be present if Observation.value[x] is not present (dataAbsentReason.empty() or value.empty())
obs-7: If Observation.component.code is the same as Observation.code, then Observation.value SHALL NOT be present (the Observation.component.value[x] holds the value). (value.empty() or component.code.where(coding.intersect(%resource.code.coding).exists()).empty())
obs-8: bodyStructure SHALL only be present if Observation.bodySite is not present (bodySite.exists() implies bodyStructure.empty())
dom-2: If the resource is contained in another resource, it SHALL NOT contain nested Resources (contained.contained.empty())
dom-3: If the resource is contained in another resource, it SHALL be referred to from elsewhere in the resource or SHALL refer to the containing resource (contained.where((('#'+id in (%resource.descendants().reference | %resource.descendants().ofType(canonical) | %resource.descendants().ofType(uri) | %resource.descendants().ofType(url))) or descendants().where(reference = '#').exists() or descendants().where(ofType(canonical) = '#').exists() or descendants().where(ofType(canonical) = '#').exists()).not()).trace('unmatched', id).empty())
dom-4: If a resource is contained in another resource, it SHALL NOT have a meta.versionId or a meta.lastUpdated (contained.meta.versionId.empty() and contained.meta.lastUpdated.empty())
dom-5: If a resource is contained in another resource, it SHALL NOT have a security label (contained.meta.security.empty())
dom-6: A resource should have narrative for robust management (text.`div`.exists())
obs-6: dataAbsentReason SHALL only be present if Observation.value[x] is not present (dataAbsentReason.empty() or value.empty())
obs-7: If Observation.component.code is the same as Observation.code, then Observation.value SHALL NOT be present (the Observation.component.value[x] holds the value). (value.empty() or component.code.where(coding.intersect(%resource.code.coding).exists()).empty())
obs-8: bodyStructure SHALL only be present if Observation.bodySite is not present (bodySite.exists() implies bodyStructure.empty())
2. Observation.implicitRules
Определение

A reference to a set of rules that were followed when the resource was constructed, and which must be understood when processing the content. Often, this is a reference to an implementation guide that defines the special rules along with other profiles etc.

КороткийA set of rules under which this content was created
Комментарии

Asserting this rule set restricts the content to be only understood by a limited set of trading partners. This inherently limits the usefulness of the data in the long term. However, the existing health eco-system is highly fractured, and not yet ready to define, collect, and exchange data in a generally computable sense. Wherever possible, implementers and/or specification writers should avoid using this element. Often, when used, the URL is a reference to an implementation guide that defines these special rules as part of its narrative along with other profiles, value sets, etc.

Контроль0..1
Типuri
Модификаторtrue потому что This element is labeled as a modifier because the implicit rules may provide additional knowledge about the resource that modifies its meaning or interpretation
Примитивное значениеЭтот примитивный элемент может присутствовать или отсутствовать, или быть замененным расширением
Требуется поддержкаfalse
Summarytrue
Инвариантыele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
ele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
4. Observation.contained
Определение

These resources do not have an independent existence apart from the resource that contains them - they cannot be identified independently, nor can they have their own independent transaction scope. This is allowed to be a Parameters resource if and only if it is referenced by a resource that provides context/meaning.

КороткийContained, inline Resources
Комментарии

This should never be done when the content can be identified properly, as once identification is lost, it is extremely difficult (and context dependent) to restore it again. Contained resources may have profiles and tags in their meta elements, but SHALL NOT have security labels.

Контроль0..*
На этот элемент влияют следующие инварианты: dom-2, dom-4, dom-3, dom-5
ТипResource
Модификаторfalse
Требуется поддержкаfalse
Summaryfalse
Альтернативные именаinline resources, anonymous resources, contained resources
6. Observation.modifierExtension
Определение

May be used to represent additional information that is not part of the basic definition of the resource and that modifies the understanding of the element that contains it and/or the understanding of the containing element's descendants. Usually modifier elements provide negation or qualification. To make the use of extensions safe and managable, there is a strict set of governance applied to the definition and use of extensions. Though any implementer is allowed to define an extension, there is a set of requirements that SHALL be met as part of the definition of the extension. Applications processing a resource are required to check for modifier extensions.

Modifier extensions SHALL NOT change the meaning of any elements on Resource or DomainResource (including cannot change the meaning of modifierExtension itself).

КороткийExtensions that cannot be ignored
Комментарии

There can be no stigma associated with the use of extensions by any application, project, or standard - regardless of the institution or jurisdiction that uses or defines the extensions. The use of extensions is what allows the FHIR specification to retain a core level of simplicity for everyone.

Контроль0..*
ТипExtension
Модификаторtrue потому что Modifier extensions are expected to modify the meaning or interpretation of the resource that contains them
Требуется поддержкаfalse
Summarytrue
Требования

Modifier extensions allow for extensions that cannot be safely ignored to be clearly distinguished from the vast majority of extensions which can be safely ignored. This promotes interoperability by eliminating the need for implementers to prohibit the presence of extensions. For further information, see the definition of modifier extensions.

Альтернативные именаextensions, user content
Инвариантыele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
ext-1: Must have either extensions or value[x], not both (extension.exists() != value.exists())
ele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
ext-1: Must have either extensions or value[x], not both (extension.exists() != value.exists())
8. Observation.identifier
Определение

A unique identifier assigned to this observation.

КороткийID to monitorBusiness Identifier for observation
ПримечаниеЭто бизнес-идентификатор, а не идентификатор ресурса (см. обсуждение)
Контроль0..*
ТипIdentifier
Модификаторfalse
Требуется поддержкаtrue
Summarytrue
Требования

Allows observations to be distinguished and referenced.

Инвариантыele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
ele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
10. Observation.status
Определение

The status of the result value.

Короткийregistered | sample in the process of processing | preliminary | final | modified | corrected | added | cancelled | entered by mistake | unknown | cannot be receivedregistered | preliminary | final | amended +
Комментарии

This element is labeled as a modifier because the status contains codes that mark the resource as not currently valid.

Контроль1..1
ПривязкаКоды ДОЛЖНЫ быть взяты из ObservationStatusVS (0.3.0)http://hl7.org/fhir/ValueSet/observation-status|5.0.0
(required to https://terminology.dhp.uz/fhir/core/ValueSet/observation-status-vs|0.3.0)
Типcode
Модификаторtrue потому что This element is labeled as a modifier because it is a status element that contains status entered-in-error which means that the resource should not be treated as valid
Примитивное значениеЭтот примитивный элемент может присутствовать или отсутствовать, или быть замененным расширением
Требуется поддержкаtrue
Summarytrue
Требования

Need to track the status of individual results. Some results are finalized before the whole report is finalized.

Инвариантыele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
ele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
12. Observation.category
Определение

A code that classifies the general type of observation being made.

КороткийClassification of types of surveillanceClassification of type of observation
Комментарии

In addition to the required category valueset, this element allows various categorization schemes based on the owner’s definition of the category and effectively multiple categories can be used at once. The level of granularity is defined by the category concepts in the value set.

Контроль0..*
ПривязкаКоды ДОЛЖНЫ быть взяты из Коды СЛЕДУЕТ взять из ObservationCategoryVS (0.3.0)http://hl7.org/fhir/ValueSet/observation-category|5.0.0
(required to https://terminology.dhp.uz/fhir/core/ValueSet/observation-category-vs|0.3.0)
ТипCodeableConcept
Модификаторfalse
Требуется поддержкаtrue
Summaryfalse
Требования

Used for filtering what observations are retrieved and displayed.

Инвариантыele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
ele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
14. Observation.code
Определение

Describes what was observed. Sometimes this is called the observation "name".

КороткийType of surveillance (code/type)Type of observation (code / type)
Комментарии

All code-value and, if present, component.code-component.value pairs need to be taken into account to correctly understand the meaning of the observation.

Контроль1..1
На этот элемент влияют следующие инварианты: obs-7
ПривязкаКоды ДОЛЖНЫ быть взяты из Например, коды см. LOINC_CodesVS (0.1.0)http://hl7.org/fhir/ValueSet/observation-codes|5.0.0
(required to https://terminology.dhp.uz/ValueSet/loinc-codes-vs|0.1.0)
ТипCodeableConcept
Модификаторfalse
Требуется поддержкаtrue
Summarytrue
Требования

Knowing what kind of observation is being made is essential to understanding the observation.

Альтернативные именаName
Инвариантыele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
ele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
16. Observation.subject
Определение

The patient, or group of patients, location, device, organization, procedure or practitioner this observation is about and into whose or what record the observation is placed. If the actual focus of the observation is different from the subject (or a sample of, part, or region of the subject), the focus element or the code itself specifies the actual focus of the observation.

КороткийAbout the patient (child)Who and/or what the observation is about
Комментарии

One would expect this element to be a cardinality of 1..1. The only circumstance in which the subject can be missing is when the observation is made by a device that does not know the patient. In this case, the observation SHALL be matched to a patient through some context/channel matching technique, and at this point, the observation should be updated. The subject of an Observation may in some cases be a procedure. This supports the regulatory inspection use case where observations are captured during inspections of a procedure that is being performed (independent of any particular patient or whether patient related at all).

Контроль0..1
ТипReference(Patient of Birth, Patient, Group, Device, Location, Organization, Procedure, Practitioner, Medication, Substance, BiologicallyDerivedProduct, NutritionProduct)
Модификаторfalse
Требуется поддержкаtrue
Summarytrue
Требования

Observations have no value if you don't know who or what they're about.

Инвариантыele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
ele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
18. Observation.effective[x]
Определение

The time or time-period the observed value is asserted as being true. For biological subjects - e.g. human patients - this is usually called the "physiologically relevant time". This is usually either the time of the procedure or of specimen collection, but very often the source of the date/time is not known, only the date/time itself.

КороткийClinically significant time/follow-up periodClinically relevant time/time-period for observation
Комментарии

At least a date should be present unless this observation is a historical report. For recording imprecise or "fuzzy" times (For example, a blood glucose measurement taken "after breakfast") use the Timing datatype which allow the measurement to be tied to regular life events.

Контроль0..1
ТипВыбор: dateTime, Period, Timing, instant
[x] ЗаметкаСмотретьВыбор типов данныхдля дополнительной информации о том, как использовать [x]
Модификаторfalse
Примитивное значениеЭтот примитивный элемент может присутствовать или отсутствовать, или быть замененным расширением
Требуется поддержкаtrue
Необходимо поддерживать типыНет обязательных правил поддержки выбора типов/профилей
Summarytrue
Требования

Knowing when an observation was deemed true is important to its relevance as well as determining trends.

Альтернативные именаOccurrence
Инвариантыele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
ele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
20. Observation.performer
Определение

Who was responsible for asserting the observed value as "true".

КороткийThe doctor or specialist who measured the resultWho is responsible for the observation
Контроль0..*
ТипReference(UZ Core Practitioner, Practitioner, PractitionerRole, Organization, CareTeam, Patient, RelatedPerson)
Модификаторfalse
Требуется поддержкаtrue
Summarytrue
Требования

May give a degree of confidence in the observation and also indicates where follow-up questions should be directed.

Инвариантыele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
ele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
22. Observation.value[x]
Определение

The information determined as a result of making the observation, if the information has a simple value.

КороткийActual result
Комментарии
  • An observation may have:
    1. a single value here
    2. both a value and a set of related or component values
    3. only a set of related or component values.
  • If a value is present, the datatype for this element should be determined by the code.
  • CodeableConcept with just a text would be used instead of a string if the field was usually coded, or if the type associated with the code defines a coded value.
  • Attachment is used if the observation result value is a binary file such as an image. If the observation result value is derived from the binary file (for example 'X' detected and here is the the proof in this image), the binary file may be directly represented using DocumentReference and referenced by derivedFrom.
  • The usage of valueReference is restricted to the MolecularSequence resource when used as a definitional resource, not as a patient-specific finding. .
  • For additional guidance, see the Notes section below.
Контроль0..1
На этот элемент влияют следующие инварианты: obs-7, obs-6
ТипВыбор: Quantity, CodeableConcept, string, boolean, integer, Range, Ratio, SampledData, time, dateTime, Period, Attachment, Reference(MolecularSequence)
[x] ЗаметкаСмотретьВыбор типов данныхдля дополнительной информации о том, как использовать [x]
Модификаторfalse
Примитивное значениеЭтот примитивный элемент может присутствовать или отсутствовать, или быть замененным расширением
Требуется поддержкаfalse
Summarytrue
Требования

An observation exists to have a value, though it might not if it is in error, or if it represents a group of observations.

Инвариантыele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
ele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
24. Observation.component
Определение

Some observations have multiple component observations. These component observations are expressed as separate code value pairs that share the same attributes. Examples include systolic and diastolic component observations for blood pressure measurement and multiple component observations for genetics observations.

КороткийComponent results
Комментарии

For a discussion on the ways Observations can be assembled in groups together see Notes below.

Контроль0..*
На этот элемент влияют следующие инварианты: obs-7
ТипBackboneElement
Модификаторfalse
Требуется поддержкаfalse
Summarytrue
Требования

Component observations share the same attributes in the Observation resource as the primary observation and are always treated a part of a single observation (they are not separable). However, the reference range for the primary observation value is not inherited by the component values and is required when appropriate for each component observation.

Инвариантыele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
ele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
SlicingЭтот элемент представляет набор разрезов на Observation.component. Разрезы бываютНе упорядочено и Open, и могут быть дифференцированы с помощью следующих дискриминаторов:
  • pattern @ code
  • 26. Observation.component.modifierExtension
    Определение

    May be used to represent additional information that is not part of the basic definition of the element and that modifies the understanding of the element in which it is contained and/or the understanding of the containing element's descendants. Usually modifier elements provide negation or qualification. To make the use of extensions safe and managable, there is a strict set of governance applied to the definition and use of extensions. Though any implementer can define an extension, there is a set of requirements that SHALL be met as part of the definition of the extension. Applications processing a resource are required to check for modifier extensions.

    Modifier extensions SHALL NOT change the meaning of any elements on Resource or DomainResource (including cannot change the meaning of modifierExtension itself).

    КороткийExtensions that cannot be ignored even if unrecognized
    Комментарии

    There can be no stigma associated with the use of extensions by any application, project, or standard - regardless of the institution or jurisdiction that uses or defines the extensions. The use of extensions is what allows the FHIR specification to retain a core level of simplicity for everyone.

    Контроль0..*
    ТипExtension
    Модификаторtrue потому что Modifier extensions are expected to modify the meaning or interpretation of the element that contains them
    Summarytrue
    Требования

    Modifier extensions allow for extensions that cannot be safely ignored to be clearly distinguished from the vast majority of extensions which can be safely ignored. This promotes interoperability by eliminating the need for implementers to prohibit the presence of extensions. For further information, see the definition of modifier extensions.

    Альтернативные именаextensions, user content, modifiers
    Инвариантыele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
    ext-1: Must have either extensions or value[x], not both (extension.exists() != value.exists())
    ele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
    ext-1: Must have either extensions or value[x], not both (extension.exists() != value.exists())
    28. Observation.component.code
    Определение

    Describes what was observed. Sometimes this is called the observation "code".

    КороткийType of component observation (code / type)
    Комментарии

    All code-value and component.code-component.value pairs need to be taken into account to correctly understand the meaning of the observation.

    Контроль1..1
    На этот элемент влияют следующие инварианты: obs-7
    ПривязкаНапример, коды см. LOINCCodeshttp://hl7.org/fhir/ValueSet/observation-codes|5.0.0
    (example to http://hl7.org/fhir/ValueSet/observation-codes|5.0.0)

    Codes identifying names of simple observations.

    ТипCodeableConcept
    Модификаторfalse
    Требуется поддержкаfalse
    Summarytrue
    Требования

    Knowing what kind of observation is being made is essential to understanding the observation.

    Инвариантыele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
    ele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
    30. Observation.component:birthMeasure
    Название разрезаbirthMeasure
    Определение

    Some observations have multiple component observations. These component observations are expressed as separate code value pairs that share the same attributes. Examples include systolic and diastolic component observations for blood pressure measurement and multiple component observations for genetics observations.

    КороткийComponent results
    Комментарии

    For a discussion on the ways Observations can be assembled in groups together see Notes below.

    Контроль0..*
    На этот элемент влияют следующие инварианты: obs-7
    ТипBackboneElement
    Модификаторfalse
    Требуется поддержкаtrue
    Summarytrue
    Требования

    Component observations share the same attributes in the Observation resource as the primary observation and are always treated a part of a single observation (they are not separable). However, the reference range for the primary observation value is not inherited by the component values and is required when appropriate for each component observation.

    Инвариантыele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
    ele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
    32. Observation.component:birthMeasure.modifierExtension
    Определение

    May be used to represent additional information that is not part of the basic definition of the element and that modifies the understanding of the element in which it is contained and/or the understanding of the containing element's descendants. Usually modifier elements provide negation or qualification. To make the use of extensions safe and managable, there is a strict set of governance applied to the definition and use of extensions. Though any implementer can define an extension, there is a set of requirements that SHALL be met as part of the definition of the extension. Applications processing a resource are required to check for modifier extensions.

    Modifier extensions SHALL NOT change the meaning of any elements on Resource or DomainResource (including cannot change the meaning of modifierExtension itself).

    КороткийExtensions that cannot be ignored even if unrecognized
    Комментарии

    There can be no stigma associated with the use of extensions by any application, project, or standard - regardless of the institution or jurisdiction that uses or defines the extensions. The use of extensions is what allows the FHIR specification to retain a core level of simplicity for everyone.

    Контроль0..*
    ТипExtension
    Модификаторtrue потому что Modifier extensions are expected to modify the meaning or interpretation of the element that contains them
    Summarytrue
    Требования

    Modifier extensions allow for extensions that cannot be safely ignored to be clearly distinguished from the vast majority of extensions which can be safely ignored. This promotes interoperability by eliminating the need for implementers to prohibit the presence of extensions. For further information, see the definition of modifier extensions.

    Альтернативные именаextensions, user content, modifiers
    Инвариантыele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
    ext-1: Must have either extensions or value[x], not both (extension.exists() != value.exists())
    ele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
    ext-1: Must have either extensions or value[x], not both (extension.exists() != value.exists())
    34. Observation.component:birthMeasure.code
    Определение

    Describes what was observed. Sometimes this is called the observation "code".

    КороткийType of componentType of component observation (code / type)
    Комментарии

    All code-value and component.code-component.value pairs need to be taken into account to correctly understand the meaning of the observation.

    Контроль1..1
    На этот элемент влияют следующие инварианты: obs-7
    ПривязкаКоды ДОЛЖНЫ быть взяты из Например, коды см. LOINCCodeshttp://hl7.org/fhir/ValueSet/observation-codes|5.0.0
    (required to http://hl7.org/fhir/ValueSet/observation-codes|5.0.0)
    ТипCodeableConcept
    Модификаторfalse
    Требуется поддержкаtrue
    Summarytrue
    Требования

    Knowing what kind of observation is being made is essential to understanding the observation.

    Инвариантыele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
    ele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
    36. Observation.component:birthMeasure.value[x]
    Определение

    The information determined as a result of making the observation, if the information has a simple value.

    КороткийActual component result
    Комментарии

    Used when observation has a set of component observations:

    • An observation may have both a value (e.g. an Apgar score) and component observations (the observations from which the Apgar score was derived).
    • If a value is present, the datatype for this element should be determined by the code.
    • CodeableConcept with just a text would be used instead of a string if the field was usually coded, or if the type associated with the code defines a coded value.
    • Attachment is used if the observation result value is a binary file such as an image. If the observation result value is derived from the binary file (for example 'X' detected and here is the the proof in this image), the binary file may be directly represented using DocumentReference and referenced by derivedFrom.
    • If a value is present, the datatype for this element should be determined by the code.
    • CodeableConcept with just a text would be used instead of a string if the field was usually coded, or if the type associated with the code defines a coded value.
    • Attachment is used if the observation result value is a binary file such as an image. If the observation result value is derived from the binary file (for example 'X' detected and here is the the proof in this image), the binary file may be directly represented using DocumentReference and referenced by derivedFrom.
    • The usage of valueReference is restricted to the MolecularSequence resource when used as a definitional resource, not as a patient-specific finding. .
    • For additional guidance, see the Notes section below.
    Контроль0..1
    ТипВыбор: Quantity, CodeableConcept, string, boolean, integer, Range, Ratio, SampledData, time, dateTime, Period, Attachment, Reference(MolecularSequence)
    [x] ЗаметкаСмотретьВыбор типов данныхдля дополнительной информации о том, как использовать [x]
    Модификаторfalse
    Примитивное значениеЭтот примитивный элемент может присутствовать или отсутствовать, или быть замененным расширением
    Требуется поддержкаfalse
    Summarytrue
    Требования

    An observation exists to have a value, though it might not if it is in error, or if it represents a group of observations.

    Инвариантыele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
    ele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
    SlicingЭтот элемент представляет набор разрезов на Observation.component.value[x]. Разрезы бываютНе упорядочено и Open, и могут быть дифференцированы с помощью следующих дискриминаторов:
    • type @ $this
    • 38. Observation.component:birthMeasure.value[x]:valueQuantity
      Название разрезаvalueQuantity
      Определение

      The information determined as a result of making the observation, if the information has a simple value.

      КороткийРост, вес ребенка при рожденииActual component result
      Комментарии

      Used when observation has a set of component observations:

      • An observation may have both a value (e.g. an Apgar score) and component observations (the observations from which the Apgar score was derived).
      • If a value is present, the datatype for this element should be determined by the code.
      • CodeableConcept with just a text would be used instead of a string if the field was usually coded, or if the type associated with the code defines a coded value.
      • Attachment is used if the observation result value is a binary file such as an image. If the observation result value is derived from the binary file (for example 'X' detected and here is the the proof in this image), the binary file may be directly represented using DocumentReference and referenced by derivedFrom.
      • If a value is present, the datatype for this element should be determined by the code.
      • CodeableConcept with just a text would be used instead of a string if the field was usually coded, or if the type associated with the code defines a coded value.
      • Attachment is used if the observation result value is a binary file such as an image. If the observation result value is derived from the binary file (for example 'X' detected and here is the the proof in this image), the binary file may be directly represented using DocumentReference and referenced by derivedFrom.
      • The usage of valueReference is restricted to the MolecularSequence resource when used as a definitional resource, not as a patient-specific finding. .
      • For additional guidance, see the Notes section below.
      Контроль0..1
      ТипQuantity, dateTime, string, Reference(MolecularSequence), Period, Attachment, integer, Range, boolean, SampledData, Ratio, time, CodeableConcept
      [x] ЗаметкаСмотретьВыбор типов данныхдля дополнительной информации о том, как использовать [x]
      Модификаторfalse
      Требуется поддержкаtrue
      Summarytrue
      Требования

      An observation exists to have a value, though it might not if it is in error, or if it represents a group of observations.

      Инвариантыele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
      ele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
      40. Observation.component:birthMeasure.value[x]:valueQuantity.value
      Определение

      The value of the measured amount. The value includes an implicit precision in the presentation of the value.

      КороткийЧисловое значение (с неявной точностью)Numerical value (with implicit precision)
      Комментарии

      The implicit precision in the value should always be honored. Monetary values have their own rules for handling precision (refer to standard accounting text books).

      Контроль0..1
      Типdecimal
      Модификаторfalse
      Примитивное значениеЭтот примитивный элемент может присутствовать или отсутствовать, или быть замененным расширением
      Требуется поддержкаtrue
      Summarytrue
      Требования

      Precision is handled implicitly in almost all cases of measurement.

      Инвариантыele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
      ele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
      42. Observation.component:birthMeasure.value[x]:valueQuantity.comparator
      Определение

      How the value should be understood and represented - whether the actual value is greater or less than the stated value due to measurement issues; e.g. if the comparator is "<" , then the real value is < stated value.

      Короткий< | <= | >= | > | ad - how to understand the value
      Контроль0..1
      ПривязкаКоды ДОЛЖНЫ быть взяты из QuantityComparatorhttp://hl7.org/fhir/ValueSet/quantity-comparator|5.0.0
      (required to http://hl7.org/fhir/ValueSet/quantity-comparator|5.0.0)

      How the Quantity should be understood and represented.

      Типcode
      Модификаторtrue потому что This is labeled as "Is Modifier" because the comparator modifies the interpretation of the value significantly. If there is no comparator, then there is no modification of the value
      Примитивное значениеЭтот примитивный элемент может присутствовать или отсутствовать, или быть замененным расширением
      Summarytrue
      Требования

      Need a framework for handling measures where the value is <5ug/L or >400mg/L due to the limitations of measuring methodology.

      Значение при отсутствииIf there is no comparator, then there is no modification of the value
      Инвариантыele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
      ele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
      44. Observation.component:birthMeasure.value[x]:valueQuantity.unit
      Определение

      A human-readable form of the unit.

      КороткийUnit representation
      Контроль0..1
      Типstring
      Модификаторfalse
      Примитивное значениеЭтот примитивный элемент может присутствовать или отсутствовать, или быть замененным расширением
      Требуется поддержкаtrue
      Summarytrue
      Требования

      There are many representations for units of measure and in many contexts, particular representations are fixed and required. I.e. mcg for micrograms.

      Инвариантыele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
      ele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
      46. Observation.component:birthMeasure.value[x]:valueQuantity.system
      Определение

      The identification of the system that provides the coded form of the unit.

      КороткийSystem that defines coded unit form
      Контроль0..1
      На этот элемент влияют следующие инварианты: qty-3
      Типuri
      Модификаторfalse
      Примитивное значениеЭтот примитивный элемент может присутствовать или отсутствовать, или быть замененным расширением
      Требуется поддержкаtrue
      Summarytrue
      Требования

      Need to know the system that defines the coded form of the unit.

      Инвариантыele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
      ele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
      48. Observation.component:birthMeasure.value[x]:valueQuantity.code
      Определение

      A computer processable form of the unit in some unit representation system.

      КороткийCoded form of the unit
      Комментарии

      The preferred system is UCUM, but SNOMED CT can also be used (for customary units) or ISO 4217 for currency. The context of use may additionally require a code from a particular system.

      Контроль0..1
      На этот элемент влияют следующие инварианты: qty-3
      ПривязкаКоды ДОЛЖНЫ быть взяты из Информацию о кодах см. LOINC_CodesVS (0.1.0)
      (required to https://terminology.dhp.uz/ValueSet/loinc-codes-vs|0.1.0)
      Типcode
      Модификаторfalse
      Примитивное значениеЭтот примитивный элемент может присутствовать или отсутствовать, или быть замененным расширением
      Требуется поддержкаtrue
      Summarytrue
      Требования

      Need a computable form of the unit that is fixed across all forms. UCUM provides this for quantities, but SNOMED CT provides many units of interest.

      Инвариантыele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
      ele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
      50. Observation.component:lifeCrit
      Название разрезаlifeCrit
      Определение

      Some observations have multiple component observations. These component observations are expressed as separate code value pairs that share the same attributes. Examples include systolic and diastolic component observations for blood pressure measurement and multiple component observations for genetics observations.

      КороткийComponent results
      Комментарии

      For a discussion on the ways Observations can be assembled in groups together see Notes below.

      Контроль0..1*
      На этот элемент влияют следующие инварианты: obs-7
      ТипBackboneElement
      Модификаторfalse
      Требуется поддержкаtrue
      Summarytrue
      Требования

      Component observations share the same attributes in the Observation resource as the primary observation and are always treated a part of a single observation (they are not separable). However, the reference range for the primary observation value is not inherited by the component values and is required when appropriate for each component observation.

      Инвариантыele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
      ele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
      52. Observation.component:lifeCrit.modifierExtension
      Определение

      May be used to represent additional information that is not part of the basic definition of the element and that modifies the understanding of the element in which it is contained and/or the understanding of the containing element's descendants. Usually modifier elements provide negation or qualification. To make the use of extensions safe and managable, there is a strict set of governance applied to the definition and use of extensions. Though any implementer can define an extension, there is a set of requirements that SHALL be met as part of the definition of the extension. Applications processing a resource are required to check for modifier extensions.

      Modifier extensions SHALL NOT change the meaning of any elements on Resource or DomainResource (including cannot change the meaning of modifierExtension itself).

      КороткийExtensions that cannot be ignored even if unrecognized
      Комментарии

      There can be no stigma associated with the use of extensions by any application, project, or standard - regardless of the institution or jurisdiction that uses or defines the extensions. The use of extensions is what allows the FHIR specification to retain a core level of simplicity for everyone.

      Контроль0..*
      ТипExtension
      Модификаторtrue потому что Modifier extensions are expected to modify the meaning or interpretation of the element that contains them
      Summarytrue
      Требования

      Modifier extensions allow for extensions that cannot be safely ignored to be clearly distinguished from the vast majority of extensions which can be safely ignored. This promotes interoperability by eliminating the need for implementers to prohibit the presence of extensions. For further information, see the definition of modifier extensions.

      Альтернативные именаextensions, user content, modifiers
      Инвариантыele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
      ext-1: Must have either extensions or value[x], not both (extension.exists() != value.exists())
      ele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
      ext-1: Must have either extensions or value[x], not both (extension.exists() != value.exists())
      54. Observation.component:lifeCrit.code
      Определение

      Describes what was observed. Sometimes this is called the observation "code".

      КороткийType of component observation (code / type)
      Комментарии

      All code-value and component.code-component.value pairs need to be taken into account to correctly understand the meaning of the observation.

      Контроль1..1
      На этот элемент влияют следующие инварианты: obs-7
      ПривязкаКоды ДОЛЖНЫ быть взяты из Например, коды см. LifeCritVS (0.1.0)http://hl7.org/fhir/ValueSet/observation-codes|5.0.0
      (required to https://terminology.dhp.uz/ValueSet/lifecrit-vs|0.1.0)
      ТипCodeableConcept
      Модификаторfalse
      Требуется поддержкаtrue
      Summarytrue
      Требования

      Knowing what kind of observation is being made is essential to understanding the observation.

      Инвариантыele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
      ele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
      56. Observation.component:lifeCrit.value[x]
      Определение

      The information determined as a result of making the observation, if the information has a simple value.

      КороткийActual component result
      Комментарии

      Used when observation has a set of component observations:

      • An observation may have both a value (e.g. an Apgar score) and component observations (the observations from which the Apgar score was derived).
      • If a value is present, the datatype for this element should be determined by the code.
      • CodeableConcept with just a text would be used instead of a string if the field was usually coded, or if the type associated with the code defines a coded value.
      • Attachment is used if the observation result value is a binary file such as an image. If the observation result value is derived from the binary file (for example 'X' detected and here is the the proof in this image), the binary file may be directly represented using DocumentReference and referenced by derivedFrom.
      • If a value is present, the datatype for this element should be determined by the code.
      • CodeableConcept with just a text would be used instead of a string if the field was usually coded, or if the type associated with the code defines a coded value.
      • Attachment is used if the observation result value is a binary file such as an image. If the observation result value is derived from the binary file (for example 'X' detected and here is the the proof in this image), the binary file may be directly represented using DocumentReference and referenced by derivedFrom.
      • The usage of valueReference is restricted to the MolecularSequence resource when used as a definitional resource, not as a patient-specific finding. .
      • For additional guidance, see the Notes section below.
      Контроль0..1
      ТипВыбор: Quantity, CodeableConcept, string, boolean, integer, Range, Ratio, SampledData, time, dateTime, Period, Attachment, Reference(MolecularSequence)
      [x] ЗаметкаСмотретьВыбор типов данныхдля дополнительной информации о том, как использовать [x]
      Модификаторfalse
      Примитивное значениеЭтот примитивный элемент может присутствовать или отсутствовать, или быть замененным расширением
      Требуется поддержкаfalse
      Summarytrue
      Требования

      An observation exists to have a value, though it might not if it is in error, or if it represents a group of observations.

      Инвариантыele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
      ele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
      SlicingЭтот элемент представляет набор разрезов на Observation.component.value[x]. Разрезы бываютНе упорядочено и Open, и могут быть дифференцированы с помощью следующих дискриминаторов:
      • type @ $this
      • 58. Observation.component:lifeCrit.value[x]:valueBoolean
        Название разрезаvalueBoolean
        Определение

        The information determined as a result of making the observation, if the information has a simple value.

        КороткийТип жизненные критерииActual component result
        Комментарии

        Used when observation has a set of component observations:

        • An observation may have both a value (e.g. an Apgar score) and component observations (the observations from which the Apgar score was derived).
        • If a value is present, the datatype for this element should be determined by the code.
        • CodeableConcept with just a text would be used instead of a string if the field was usually coded, or if the type associated with the code defines a coded value.
        • Attachment is used if the observation result value is a binary file such as an image. If the observation result value is derived from the binary file (for example 'X' detected and here is the the proof in this image), the binary file may be directly represented using DocumentReference and referenced by derivedFrom.
        • If a value is present, the datatype for this element should be determined by the code.
        • CodeableConcept with just a text would be used instead of a string if the field was usually coded, or if the type associated with the code defines a coded value.
        • Attachment is used if the observation result value is a binary file such as an image. If the observation result value is derived from the binary file (for example 'X' detected and here is the the proof in this image), the binary file may be directly represented using DocumentReference and referenced by derivedFrom.
        • The usage of valueReference is restricted to the MolecularSequence resource when used as a definitional resource, not as a patient-specific finding. .
        • For additional guidance, see the Notes section below.
        Контроль0..1
        Типboolean, dateTime, string, Reference(MolecularSequence), Quantity, Period, Attachment, integer, Range, SampledData, Ratio, time, CodeableConcept
        [x] ЗаметкаСмотретьВыбор типов данныхдля дополнительной информации о том, как использовать [x]
        Модификаторfalse
        Примитивное значениеЭтот примитивный элемент может присутствовать или отсутствовать, или быть замененным расширением
        Требуется поддержкаtrue
        Summarytrue
        Требования

        An observation exists to have a value, though it might not if it is in error, or if it represents a group of observations.

        Инвариантыele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
        ele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))

        Рекомендации по толкованию содержимого этой таблицы можно найтиздесь-- no content: do not translate #97 --

        0. Observation
        2. Observation.identifier
        КороткийID to monitor
        ПримечаниеЭто бизнес-идентификатор, а не идентификатор ресурса (см. обсуждение)
        Требуется поддержкаtrue
        4. Observation.status
        Короткийregistered | sample in the process of processing | preliminary | final | modified | corrected | added | cancelled | entered by mistake | unknown | cannot be received
        ПривязкаКоды ДОЛЖНЫ быть взяты из ObservationStatusVS (0.3.0)
        (required to https://terminology.dhp.uz/fhir/core/ValueSet/observation-status-vs|0.3.0)
        Требуется поддержкаtrue
        6. Observation.category
        КороткийClassification of types of surveillance
        ПривязкаКоды ДОЛЖНЫ быть взяты из ObservationCategoryVS (0.3.0)
        (required to https://terminology.dhp.uz/fhir/core/ValueSet/observation-category-vs|0.3.0)
        Требуется поддержкаtrue
        8. Observation.code
        КороткийType of surveillance (code/type)
        ПривязкаКоды ДОЛЖНЫ быть взяты из LOINC_CodesVS (0.1.0)
        (required to https://terminology.dhp.uz/ValueSet/loinc-codes-vs|0.1.0)
        Требуется поддержкаtrue
        10. Observation.subject
        КороткийAbout the patient (child)
        ТипReference(Patient of Birth)
        Требуется поддержкаtrue
        12. Observation.effective[x]
        КороткийClinically significant time/follow-up period
        [x] ЗаметкаСмотретьВыбор типов данныхдля дополнительной информации о том, как использовать [x]
        Требуется поддержкаtrue
        14. Observation.performer
        КороткийThe doctor or specialist who measured the result
        ТипReference(UZ Core Practitioner)
        Требуется поддержкаtrue
        16. Observation.component
        SlicingЭтот элемент представляет набор разрезов на Observation.component. Разрезы бываютНе упорядочено и Open, и могут быть дифференцированы с помощью следующих дискриминаторов:
        • pattern @ code
        • 18. Observation.component:birthMeasure
          Название разрезаbirthMeasure
          Контроль0..*
          Требуется поддержкаtrue
          20. Observation.component:birthMeasure.code
          КороткийType of component
          ПривязкаКоды ДОЛЖНЫ быть взяты из LOINCCodes
          (required to http://hl7.org/fhir/ValueSet/observation-codes|5.0.0)
          Требуется поддержкаtrue
          22. Observation.component:birthMeasure.value[x]
          [x] ЗаметкаСмотретьВыбор типов данныхдля дополнительной информации о том, как использовать [x]
          SlicingЭтот элемент представляет набор разрезов на Observation.component.value[x]. Разрезы бываютНе упорядочено и Open, и могут быть дифференцированы с помощью следующих дискриминаторов:
          • type @ $this
          • 24. Observation.component:birthMeasure.value[x]:valueQuantity
            Название разрезаvalueQuantity
            КороткийРост, вес ребенка при рождении
            Контроль0..1
            ТипQuantity
            [x] ЗаметкаСмотретьВыбор типов данныхдля дополнительной информации о том, как использовать [x]
            Требуется поддержкаtrue
            26. Observation.component:birthMeasure.value[x]:valueQuantity.value
            КороткийЧисловое значение (с неявной точностью)
            Требуется поддержкаtrue
            28. Observation.component:birthMeasure.value[x]:valueQuantity.unit
            Требуется поддержкаtrue
            30. Observation.component:birthMeasure.value[x]:valueQuantity.system
            Требуется поддержкаtrue
            32. Observation.component:birthMeasure.value[x]:valueQuantity.code
            ПривязкаКоды ДОЛЖНЫ быть взяты из LOINC_CodesVS (0.1.0)
            (required to https://terminology.dhp.uz/ValueSet/loinc-codes-vs|0.1.0)
            Требуется поддержкаtrue
            34. Observation.component:lifeCrit
            Название разрезаlifeCrit
            Контроль0..1
            Требуется поддержкаtrue
            36. Observation.component:lifeCrit.code
            ПривязкаКоды ДОЛЖНЫ быть взяты из LifeCritVS (0.1.0)
            (required to https://terminology.dhp.uz/ValueSet/lifecrit-vs|0.1.0)
            Требуется поддержкаtrue
            38. Observation.component:lifeCrit.value[x]
            [x] ЗаметкаСмотретьВыбор типов данныхдля дополнительной информации о том, как использовать [x]
            SlicingЭтот элемент представляет набор разрезов на Observation.component.value[x]. Разрезы бываютНе упорядочено и Open, и могут быть дифференцированы с помощью следующих дискриминаторов:
            • type @ $this
            • 40. Observation.component:lifeCrit.value[x]:valueBoolean
              Название разрезаvalueBoolean
              КороткийТип жизненные критерии
              Контроль0..1
              Типboolean
              [x] ЗаметкаСмотретьВыбор типов данныхдля дополнительной информации о том, как использовать [x]
              Примитивное значениеЭтот примитивный элемент может присутствовать или отсутствовать, или быть замененным расширением
              Требуется поддержкаtrue

              Рекомендации по толкованию содержимого этой таблицы можно найтиздесь-- no content: do not translate #97 --

              0. Observation
              Определение

              Measurements and simple assertions made about a patient, device or other subject.

              КороткийMeasurements and simple assertions
              Комментарии

              Used for simple observations such as device measurements, laboratory atomic results, vital signs, height, weight, smoking status, comments, etc. Other resources are used to provide context for observations such as laboratory reports, etc.

              Контроль0..*
              Модификаторfalse
              Требуется поддержкаfalse
              Summaryfalse
              Альтернативные именаVital Signs, Measurement, Results, Tests
              Инвариантыdom-2: If the resource is contained in another resource, it SHALL NOT contain nested Resources (contained.contained.empty())
              dom-3: If the resource is contained in another resource, it SHALL be referred to from elsewhere in the resource or SHALL refer to the containing resource (contained.where((('#'+id in (%resource.descendants().reference | %resource.descendants().ofType(canonical) | %resource.descendants().ofType(uri) | %resource.descendants().ofType(url))) or descendants().where(reference = '#').exists() or descendants().where(ofType(canonical) = '#').exists() or descendants().where(ofType(canonical) = '#').exists()).not()).trace('unmatched', id).empty())
              dom-4: If a resource is contained in another resource, it SHALL NOT have a meta.versionId or a meta.lastUpdated (contained.meta.versionId.empty() and contained.meta.lastUpdated.empty())
              dom-5: If a resource is contained in another resource, it SHALL NOT have a security label (contained.meta.security.empty())
              dom-6: A resource should have narrative for robust management (text.`div`.exists())
              obs-6: dataAbsentReason SHALL only be present if Observation.value[x] is not present (dataAbsentReason.empty() or value.empty())
              obs-7: If Observation.component.code is the same as Observation.code, then Observation.value SHALL NOT be present (the Observation.component.value[x] holds the value). (value.empty() or component.code.where(coding.intersect(%resource.code.coding).exists()).empty())
              obs-8: bodyStructure SHALL only be present if Observation.bodySite is not present (bodySite.exists() implies bodyStructure.empty())
              2. Observation.id
              Определение

              The logical id of the resource, as used in the URL for the resource. Once assigned, this value never changes.

              КороткийLogical id of this artifact
              Комментарии

              Within the context of the FHIR RESTful interactions, the resource has an id except for cases like the create and conditional update. Otherwise, the use of the resouce id depends on the given use case.

              Контроль0..1
              Типid
              Модификаторfalse
              Требуется поддержкаfalse
              Summarytrue
              4. Observation.meta
              Определение

              The metadata about the resource. This is content that is maintained by the infrastructure. Changes to the content might not always be associated with version changes to the resource.

              КороткийMetadata about the resource
              Контроль0..1
              ТипMeta
              Модификаторfalse
              Требуется поддержкаfalse
              Summarytrue
              Инвариантыele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
              6. Observation.implicitRules
              Определение

              A reference to a set of rules that were followed when the resource was constructed, and which must be understood when processing the content. Often, this is a reference to an implementation guide that defines the special rules along with other profiles etc.

              КороткийA set of rules under which this content was created
              Комментарии

              Asserting this rule set restricts the content to be only understood by a limited set of trading partners. This inherently limits the usefulness of the data in the long term. However, the existing health eco-system is highly fractured, and not yet ready to define, collect, and exchange data in a generally computable sense. Wherever possible, implementers and/or specification writers should avoid using this element. Often, when used, the URL is a reference to an implementation guide that defines these special rules as part of its narrative along with other profiles, value sets, etc.

              Контроль0..1
              Типuri
              Модификаторtrue потому что This element is labeled as a modifier because the implicit rules may provide additional knowledge about the resource that modifies its meaning or interpretation
              Примитивное значениеЭтот примитивный элемент может присутствовать или отсутствовать, или быть замененным расширением
              Требуется поддержкаfalse
              Summarytrue
              Инвариантыele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
              8. Observation.language
              Определение

              The base language in which the resource is written.

              КороткийLanguage of the resource content
              Комментарии

              Language is provided to support indexing and accessibility (typically, services such as text to speech use the language tag). The html language tag in the narrative applies to the narrative. The language tag on the resource may be used to specify the language of other presentations generated from the data in the resource. Not all the content has to be in the base language. The Resource.language should not be assumed to apply to the narrative automatically. If a language is specified, it should it also be specified on the div element in the html (see rules in HTML5 for information about the relationship between xml:lang and the html lang attribute).

              Контроль0..1
              ПривязкаКоды ДОЛЖНЫ быть взяты из AllLanguages
              (required to http://hl7.org/fhir/ValueSet/all-languages|5.0.0)

              IETF language tag for a human language

              Типcode
              Модификаторfalse
              Примитивное значениеЭтот примитивный элемент может присутствовать или отсутствовать, или быть замененным расширением
              Требуется поддержкаfalse
              Summaryfalse
              Инвариантыele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
              10. Observation.text
              Определение

              A human-readable narrative that contains a summary of the resource and can be used to represent the content of the resource to a human. The narrative need not encode all the structured data, but is required to contain sufficient detail to make it "clinically safe" for a human to just read the narrative. Resource definitions may define what content should be represented in the narrative to ensure clinical safety.

              КороткийText summary of the resource, for human interpretation
              Комментарии

              Contained resources do not have a narrative. Resources that are not contained SHOULD have a narrative. In some cases, a resource may only have text with little or no additional discrete data (as long as all minOccurs=1 elements are satisfied). This may be necessary for data from legacy systems where information is captured as a "text blob" or where text is additionally entered raw or narrated and encoded information is added later.

              Контроль0..1
              На этот элемент влияют следующие инварианты: dom-6
              ТипNarrative
              Модификаторfalse
              Требуется поддержкаfalse
              Summaryfalse
              Альтернативные именаnarrative, html, xhtml, display
              Инвариантыele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
              12. Observation.contained
              Определение

              These resources do not have an independent existence apart from the resource that contains them - they cannot be identified independently, nor can they have their own independent transaction scope. This is allowed to be a Parameters resource if and only if it is referenced by a resource that provides context/meaning.

              КороткийContained, inline Resources
              Комментарии

              This should never be done when the content can be identified properly, as once identification is lost, it is extremely difficult (and context dependent) to restore it again. Contained resources may have profiles and tags in their meta elements, but SHALL NOT have security labels.

              Контроль0..*
              На этот элемент влияют следующие инварианты: dom-2, dom-4, dom-3, dom-5
              ТипResource
              Модификаторfalse
              Требуется поддержкаfalse
              Summaryfalse
              Альтернативные именаinline resources, anonymous resources, contained resources
              14. Observation.extension
              Определение

              May be used to represent additional information that is not part of the basic definition of the resource. To make the use of extensions safe and managable, there is a strict set of governance applied to the definition and use of extensions. Though any implementer can define an extension, there is a set of requirements that SHALL be met as part of the definition of the extension.

              КороткийAdditional content defined by implementations
              Комментарии

              There can be no stigma associated with the use of extensions by any application, project, or standard - regardless of the institution or jurisdiction that uses or defines the extensions. The use of extensions is what allows the FHIR specification to retain a core level of simplicity for everyone.

              Контроль0..*
              ТипExtension
              Модификаторfalse
              Требуется поддержкаfalse
              Summaryfalse
              Альтернативные именаextensions, user content
              Инвариантыele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
              ext-1: Must have either extensions or value[x], not both (extension.exists() != value.exists())
              16. Observation.modifierExtension
              Определение

              May be used to represent additional information that is not part of the basic definition of the resource and that modifies the understanding of the element that contains it and/or the understanding of the containing element's descendants. Usually modifier elements provide negation or qualification. To make the use of extensions safe and managable, there is a strict set of governance applied to the definition and use of extensions. Though any implementer is allowed to define an extension, there is a set of requirements that SHALL be met as part of the definition of the extension. Applications processing a resource are required to check for modifier extensions.

              Modifier extensions SHALL NOT change the meaning of any elements on Resource or DomainResource (including cannot change the meaning of modifierExtension itself).

              КороткийExtensions that cannot be ignored
              Комментарии

              There can be no stigma associated with the use of extensions by any application, project, or standard - regardless of the institution or jurisdiction that uses or defines the extensions. The use of extensions is what allows the FHIR specification to retain a core level of simplicity for everyone.

              Контроль0..*
              ТипExtension
              Модификаторtrue потому что Modifier extensions are expected to modify the meaning or interpretation of the resource that contains them
              Требуется поддержкаfalse
              Summarytrue
              Требования

              Modifier extensions allow for extensions that cannot be safely ignored to be clearly distinguished from the vast majority of extensions which can be safely ignored. This promotes interoperability by eliminating the need for implementers to prohibit the presence of extensions. For further information, see the definition of modifier extensions.

              Альтернативные именаextensions, user content
              Инвариантыele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
              ext-1: Must have either extensions or value[x], not both (extension.exists() != value.exists())
              18. Observation.identifier
              Определение

              A unique identifier assigned to this observation.

              КороткийID to monitor
              ПримечаниеЭто бизнес-идентификатор, а не идентификатор ресурса (см. обсуждение)
              Контроль0..*
              ТипIdentifier
              Модификаторfalse
              Требуется поддержкаtrue
              Summarytrue
              Требования

              Allows observations to be distinguished and referenced.

              Инвариантыele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
              20. Observation.instantiates[x]
              Определение

              The reference to a FHIR ObservationDefinition resource that provides the definition that is adhered to in whole or in part by this Observation instance.

              КороткийInstantiates FHIR ObservationDefinition
              Комментарии

              ObservationDefinition can be referenced by its canonical url using instantiatesCanonical, or by a name or an identifier using the appropriate sub-elements of instantiatesReference.

              Контроль0..1
              ТипВыбор: canonical(ObservationDefinition), Reference(ObservationDefinition)
              [x] ЗаметкаСмотретьВыбор типов данныхдля дополнительной информации о том, как использовать [x]
              Модификаторfalse
              Примитивное значениеЭтот примитивный элемент может присутствовать или отсутствовать, или быть замененным расширением
              Требуется поддержкаfalse
              Summarytrue
              Инвариантыele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
              22. Observation.basedOn
              Определение

              A plan, proposal or order that is fulfilled in whole or in part by this event. For example, a MedicationRequest may require a patient to have laboratory test performed before it is dispensed.

              КороткийFulfills plan, proposal or order
              Контроль0..*
              ТипReference(CarePlan, DeviceRequest, ImmunizationRecommendation, MedicationRequest, NutritionOrder, ServiceRequest)
              Модификаторfalse
              Требуется поддержкаfalse
              Summarytrue
              Требования

              Allows tracing of authorization for the event and tracking whether proposals/recommendations were acted upon.

              Альтернативные именаFulfills
              Инвариантыele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
              24. Observation.triggeredBy
              Определение

              Identifies the observation(s) that triggered the performance of this observation.

              КороткийTriggering observation(s)
              Контроль0..*
              ТипBackboneElement
              Модификаторfalse
              Требуется поддержкаfalse
              Summaryfalse
              Инвариантыele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
              26. Observation.triggeredBy.id
              Определение

              Unique id for the element within a resource (for internal references). This may be any string value that does not contain spaces.

              КороткийUnique id for inter-element referencing
              Контроль0..1
              На этот элемент влияют следующие инварианты: ele-1
              Типstring
              Модификаторfalse
              Формат XMLВ формате XML это свойство представлено в качестве атрибута.
              Summaryfalse
              28. Observation.triggeredBy.extension
              Определение

              May be used to represent additional information that is not part of the basic definition of the element. To make the use of extensions safe and managable, there is a strict set of governance applied to the definition and use of extensions. Though any implementer can define an extension, there is a set of requirements that SHALL be met as part of the definition of the extension.

              КороткийAdditional content defined by implementations
              Комментарии

              There can be no stigma associated with the use of extensions by any application, project, or standard - regardless of the institution or jurisdiction that uses or defines the extensions. The use of extensions is what allows the FHIR specification to retain a core level of simplicity for everyone.

              Контроль0..*
              ТипExtension
              Модификаторfalse
              Summaryfalse
              Альтернативные именаextensions, user content
              Инвариантыele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
              ext-1: Must have either extensions or value[x], not both (extension.exists() != value.exists())
              30. Observation.triggeredBy.modifierExtension
              Определение

              May be used to represent additional information that is not part of the basic definition of the element and that modifies the understanding of the element in which it is contained and/or the understanding of the containing element's descendants. Usually modifier elements provide negation or qualification. To make the use of extensions safe and managable, there is a strict set of governance applied to the definition and use of extensions. Though any implementer can define an extension, there is a set of requirements that SHALL be met as part of the definition of the extension. Applications processing a resource are required to check for modifier extensions.

              Modifier extensions SHALL NOT change the meaning of any elements on Resource or DomainResource (including cannot change the meaning of modifierExtension itself).

              КороткийExtensions that cannot be ignored even if unrecognized
              Комментарии

              There can be no stigma associated with the use of extensions by any application, project, or standard - regardless of the institution or jurisdiction that uses or defines the extensions. The use of extensions is what allows the FHIR specification to retain a core level of simplicity for everyone.

              Контроль0..*
              ТипExtension
              Модификаторtrue потому что Modifier extensions are expected to modify the meaning or interpretation of the element that contains them
              Summarytrue
              Требования

              Modifier extensions allow for extensions that cannot be safely ignored to be clearly distinguished from the vast majority of extensions which can be safely ignored. This promotes interoperability by eliminating the need for implementers to prohibit the presence of extensions. For further information, see the definition of modifier extensions.

              Альтернативные именаextensions, user content, modifiers
              Инвариантыele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
              ext-1: Must have either extensions or value[x], not both (extension.exists() != value.exists())
              32. Observation.triggeredBy.observation
              Определение

              Reference to the triggering observation.

              КороткийTriggering observation
              Контроль1..1
              ТипReference(Observation)
              Модификаторfalse
              Требуется поддержкаfalse
              Summarytrue
              Инвариантыele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
              34. Observation.triggeredBy.type
              Определение

              The type of trigger. Reflex | Repeat | Re-run.

              Короткийreflex | repeat | re-run
              Контроль1..1
              ПривязкаКоды ДОЛЖНЫ быть взяты из TriggeredBytype
              (required to http://hl7.org/fhir/ValueSet/observation-triggeredbytype|5.0.0)

              The type of TriggeredBy Observation.

              Типcode
              Модификаторfalse
              Примитивное значениеЭтот примитивный элемент может присутствовать или отсутствовать, или быть замененным расширением
              Требуется поддержкаfalse
              Summarytrue
              Инвариантыele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
              36. Observation.triggeredBy.reason
              Определение

              Provides the reason why this observation was performed as a result of the observation(s) referenced.

              КороткийReason that the observation was triggered
              Контроль0..1
              Типstring
              Модификаторfalse
              Примитивное значениеЭтот примитивный элемент может присутствовать или отсутствовать, или быть замененным расширением
              Требуется поддержкаfalse
              Summaryfalse
              Инвариантыele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
              38. Observation.partOf
              Определение

              A larger event of which this particular Observation is a component or step. For example, an observation as part of a procedure.

              КороткийPart of referenced event
              Комментарии

              To link an Observation to an Encounter use encounter. See the Notes below for guidance on referencing another Observation.

              Контроль0..*
              ТипReference(MedicationAdministration, MedicationDispense, MedicationStatement, Procedure, Immunization, ImagingStudy, GenomicStudy)
              Модификаторfalse
              Требуется поддержкаfalse
              Summarytrue
              Альтернативные именаContainer
              Инвариантыele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
              40. Observation.status
              Определение

              The status of the result value.

              Короткийregistered | sample in the process of processing | preliminary | final | modified | corrected | added | cancelled | entered by mistake | unknown | cannot be received
              Комментарии

              This element is labeled as a modifier because the status contains codes that mark the resource as not currently valid.

              Контроль1..1
              ПривязкаКоды ДОЛЖНЫ быть взяты из ObservationStatusVS (0.3.0)
              (required to https://terminology.dhp.uz/fhir/core/ValueSet/observation-status-vs|0.3.0)
              Типcode
              Модификаторtrue потому что This element is labeled as a modifier because it is a status element that contains status entered-in-error which means that the resource should not be treated as valid
              Примитивное значениеЭтот примитивный элемент может присутствовать или отсутствовать, или быть замененным расширением
              Требуется поддержкаtrue
              Summarytrue
              Требования

              Need to track the status of individual results. Some results are finalized before the whole report is finalized.

              Инвариантыele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
              42. Observation.category
              Определение

              A code that classifies the general type of observation being made.

              КороткийClassification of types of surveillance
              Комментарии

              In addition to the required category valueset, this element allows various categorization schemes based on the owner’s definition of the category and effectively multiple categories can be used at once. The level of granularity is defined by the category concepts in the value set.

              Контроль0..*
              ПривязкаКоды ДОЛЖНЫ быть взяты из ObservationCategoryVS (0.3.0)
              (required to https://terminology.dhp.uz/fhir/core/ValueSet/observation-category-vs|0.3.0)
              ТипCodeableConcept
              Модификаторfalse
              Требуется поддержкаtrue
              Summaryfalse
              Требования

              Used for filtering what observations are retrieved and displayed.

              Инвариантыele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
              44. Observation.code
              Определение

              Describes what was observed. Sometimes this is called the observation "name".

              КороткийType of surveillance (code/type)
              Комментарии

              All code-value and, if present, component.code-component.value pairs need to be taken into account to correctly understand the meaning of the observation.

              Контроль1..1
              На этот элемент влияют следующие инварианты: obs-7
              ПривязкаКоды ДОЛЖНЫ быть взяты из LOINC_CodesVS (0.1.0)
              (required to https://terminology.dhp.uz/ValueSet/loinc-codes-vs|0.1.0)
              ТипCodeableConcept
              Модификаторfalse
              Требуется поддержкаtrue
              Summarytrue
              Требования

              Knowing what kind of observation is being made is essential to understanding the observation.

              Альтернативные именаName
              Инвариантыele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
              46. Observation.subject
              Определение

              The patient, or group of patients, location, device, organization, procedure or practitioner this observation is about and into whose or what record the observation is placed. If the actual focus of the observation is different from the subject (or a sample of, part, or region of the subject), the focus element or the code itself specifies the actual focus of the observation.

              КороткийAbout the patient (child)
              Комментарии

              One would expect this element to be a cardinality of 1..1. The only circumstance in which the subject can be missing is when the observation is made by a device that does not know the patient. In this case, the observation SHALL be matched to a patient through some context/channel matching technique, and at this point, the observation should be updated. The subject of an Observation may in some cases be a procedure. This supports the regulatory inspection use case where observations are captured during inspections of a procedure that is being performed (independent of any particular patient or whether patient related at all).

              Контроль0..1
              ТипReference(Patient of Birth)
              Модификаторfalse
              Требуется поддержкаtrue
              Summarytrue
              Требования

              Observations have no value if you don't know who or what they're about.

              Инвариантыele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
              48. Observation.focus
              Определение

              The actual focus of an observation when it is not the patient of record representing something or someone associated with the patient such as a spouse, parent, fetus, or donor. For example, fetus observations in a mother's record. The focus of an observation could also be an existing condition, an intervention, the subject's diet, another observation of the subject, or a body structure such as tumor or implanted device. An example use case would be using the Observation resource to capture whether the mother is trained to change her child's tracheostomy tube. In this example, the child is the patient of record and the mother is the focus.

              КороткийWhat the observation is about, when it is not about the subject of record
              Комментарии

              Typically, an observation is made about the subject - a patient, or group of patients, location, or device - and the distinction between the subject and what is directly measured for an observation is specified in the observation code itself ( e.g., "Blood Glucose") and does not need to be represented separately using this element. Use specimen if a reference to a specimen is required. If a code is required instead of a resource use either bodysite for bodysites or the standard extension http://hl7.org/fhir/StructureDefinition/observation-focusCode.

              Контроль0..*
              ТипReference(Resource)
              Модификаторfalse
              Требуется поддержкаfalse
              Summarytrue
              Инвариантыele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
              50. Observation.encounter
              Определение

              The healthcare event (e.g. a patient and healthcare provider interaction) during which this observation is made.

              КороткийHealthcare event during which this observation is made
              Комментарии

              This will typically be the encounter the event occurred within, but some events may be initiated prior to or after the official completion of an encounter but still be tied to the context of the encounter (e.g. pre-admission laboratory tests).

              Контроль0..1
              ТипReference(Encounter)
              Модификаторfalse
              Требуется поддержкаfalse
              Summarytrue
              Требования

              For some observations it may be important to know the link between an observation and a particular encounter.

              Альтернативные именаContext
              Инвариантыele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
              52. Observation.effective[x]
              Определение

              The time or time-period the observed value is asserted as being true. For biological subjects - e.g. human patients - this is usually called the "physiologically relevant time". This is usually either the time of the procedure or of specimen collection, but very often the source of the date/time is not known, only the date/time itself.

              КороткийClinically significant time/follow-up period
              Комментарии

              At least a date should be present unless this observation is a historical report. For recording imprecise or "fuzzy" times (For example, a blood glucose measurement taken "after breakfast") use the Timing datatype which allow the measurement to be tied to regular life events.

              Контроль0..1
              ТипВыбор: dateTime, Period, Timing, instant
              [x] ЗаметкаСмотретьВыбор типов данныхдля дополнительной информации о том, как использовать [x]
              Модификаторfalse
              Примитивное значениеЭтот примитивный элемент может присутствовать или отсутствовать, или быть замененным расширением
              Требуется поддержкаtrue
              Необходимо поддерживать типыНет обязательных правил поддержки выбора типов/профилей
              Summarytrue
              Требования

              Knowing when an observation was deemed true is important to its relevance as well as determining trends.

              Альтернативные именаOccurrence
              Инвариантыele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
              54. Observation.issued
              Определение

              The date and time this version of the observation was made available to providers, typically after the results have been reviewed and verified.

              КороткийDate/Time this version was made available
              Комментарии

              For Observations that don't require review and verification, it may be the same as the lastUpdated time of the resource itself. For Observations that do require review and verification for certain updates, it might not be the same as the lastUpdated time of the resource itself due to a non-clinically significant update that doesn't require the new version to be reviewed and verified again.

              Контроль0..1
              Типinstant
              Модификаторfalse
              Примитивное значениеЭтот примитивный элемент может присутствовать или отсутствовать, или быть замененным расширением
              Требуется поддержкаfalse
              Summarytrue
              Инвариантыele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
              56. Observation.performer
              Определение

              Who was responsible for asserting the observed value as "true".

              КороткийThe doctor or specialist who measured the result
              Контроль0..*
              ТипReference(UZ Core Practitioner)
              Модификаторfalse
              Требуется поддержкаtrue
              Summarytrue
              Требования

              May give a degree of confidence in the observation and also indicates where follow-up questions should be directed.

              Инвариантыele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
              58. Observation.value[x]
              Определение

              The information determined as a result of making the observation, if the information has a simple value.

              КороткийActual result
              Комментарии
              • An observation may have:
                1. a single value here
                2. both a value and a set of related or component values
                3. only a set of related or component values.
              • If a value is present, the datatype for this element should be determined by the code.
              • CodeableConcept with just a text would be used instead of a string if the field was usually coded, or if the type associated with the code defines a coded value.
              • Attachment is used if the observation result value is a binary file such as an image. If the observation result value is derived from the binary file (for example 'X' detected and here is the the proof in this image), the binary file may be directly represented using DocumentReference and referenced by derivedFrom.
              • The usage of valueReference is restricted to the MolecularSequence resource when used as a definitional resource, not as a patient-specific finding. .
              • For additional guidance, see the Notes section below.
              Контроль0..1
              На этот элемент влияют следующие инварианты: obs-7, obs-6
              ТипВыбор: Quantity, CodeableConcept, string, boolean, integer, Range, Ratio, SampledData, time, dateTime, Period, Attachment, Reference(MolecularSequence)
              [x] ЗаметкаСмотретьВыбор типов данныхдля дополнительной информации о том, как использовать [x]
              Модификаторfalse
              Примитивное значениеЭтот примитивный элемент может присутствовать или отсутствовать, или быть замененным расширением
              Требуется поддержкаfalse
              Summarytrue
              Требования

              An observation exists to have a value, though it might not if it is in error, or if it represents a group of observations.

              Инвариантыele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
              60. Observation.dataAbsentReason
              Определение

              Provides a reason why the expected value in the element Observation.value[x] is missing.

              КороткийWhy the result is missing
              Комментарии

              Null or exceptional values can be represented two ways in FHIR Observations. One way is to simply include them in the value set and represent the exceptions in the value. For example, measurement values for a serology test could be "detected", "not detected", "inconclusive", or "specimen unsatisfactory".

              The alternate way is to use the value element for actual observations and use the explicit dataAbsentReason element to record exceptional values. For example, the dataAbsentReason code "error" could be used when the measurement was not completed. Note that an observation may only be reported if there are values to report. For example differential cell counts values may be reported only when > 0. Because of these options, use-case agreements are required to interpret general observations for null or exceptional values.

              Контроль0..1
              На этот элемент влияют следующие инварианты: obs-6
              ПривязкаЕсли они не подходят, эти коды ДОЛЖНЫ быть взяты из DataAbsentReason
              (extensible to http://hl7.org/fhir/ValueSet/data-absent-reason|5.0.0)

              Codes specifying why the result (Observation.value[x]) is missing.

              ТипCodeableConcept
              Модификаторfalse
              Требуется поддержкаfalse
              Summaryfalse
              Требования

              For many results it is necessary to handle exceptional values in measurements.

              Инвариантыele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
              62. Observation.interpretation
              Определение

              A categorical assessment of an observation value. For example, high, low, normal.

              КороткийHigh, low, normal, etc
              Комментарии

              Historically used for laboratory results (known as 'abnormal flag' ), its use extends to other use cases where coded interpretations are relevant. Often reported as one or more simple compact codes this element is often placed adjacent to the result value in reports and flow sheets to signal the meaning/normalcy status of the result.

              Контроль0..*
              ПривязкаЕсли они не подходят, эти коды ДОЛЖНЫ быть взяты из ObservationInterpretationCodes
              (extensible to http://hl7.org/fhir/ValueSet/observation-interpretation|5.0.0)

              Codes identifying interpretations of observations.

              ТипCodeableConcept
              Модификаторfalse
              Требуется поддержкаfalse
              Summaryfalse
              Требования

              For some results, particularly numeric results, an interpretation is necessary to fully understand the significance of a result.

              Альтернативные именаAbnormal Flag
              Инвариантыele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
              64. Observation.note
              Определение

              Comments about the observation or the results.

              КороткийComments about the observation
              Комментарии

              May include general statements about the observation, or statements about significant, unexpected or unreliable results values, or information about its source when relevant to its interpretation.

              Контроль0..*
              ТипAnnotation
              Модификаторfalse
              Требуется поддержкаfalse
              Summaryfalse
              Требования

              Need to be able to provide free text additional information.

              Инвариантыele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
              66. Observation.bodySite
              Определение

              Indicates the site on the subject's body where the observation was made (i.e. the target site).

              КороткийObserved body part
              Комментарии

              Only used if not implicit in code found in Observation.code. In many systems, this may be represented as a related observation instead of an inline component.

              Контроль0..1
              На этот элемент влияют следующие инварианты: obs-8
              ПривязкаНапример, коды см. SNOMEDCTBodyStructures
              (example to http://hl7.org/fhir/ValueSet/body-site|5.0.0)

              SNOMED CT Body site concepts

              ТипCodeableConcept
              Модификаторfalse
              Требуется поддержкаfalse
              Summaryfalse
              Инвариантыele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
              68. Observation.bodyStructure
              Определение

              Indicates the body structure on the subject's body where the observation was made (i.e. the target site).

              КороткийObserved body structure
              Комментарии

              Only used if not implicit in code found in Observation.code or bodySite is used. In many systems, this may be represented as a related observation instead of an inline component.

              Контроль0..1
              На этот элемент влияют следующие инварианты: obs-8
              ТипReference(BodyStructure)
              Модификаторfalse
              Требуется поддержкаfalse
              Summaryfalse
              Инвариантыele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
              70. Observation.method
              Определение

              Indicates the mechanism used to perform the observation.

              КороткийHow it was done
              Комментарии

              Only used if not implicit in code for Observation.code.

              Контроль0..1
              ПривязкаНапример, коды см. ObservationMethods
              (example to http://hl7.org/fhir/ValueSet/observation-methods|5.0.0)

              Methods for simple observations.

              ТипCodeableConcept
              Модификаторfalse
              Требуется поддержкаfalse
              Summaryfalse
              Требования

              In some cases, method can impact results and is thus used for determining whether results can be compared or determining significance of results.

              Инвариантыele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
              72. Observation.specimen
              Определение

              The specimen that was used when this observation was made.

              КороткийSpecimen used for this observation
              Комментарии

              Should only be used if not implicit in code found in Observation.code. Observations are not made on specimens themselves; they are made on a subject, but in many cases by the means of a specimen. Note that although specimens are often involved, they are not always tracked and reported explicitly. Also note that observation resources may be used in contexts that track the specimen explicitly (e.g. Diagnostic Report).

              Контроль0..1
              ТипReference(Specimen, Group)
              Модификаторfalse
              Требуется поддержкаfalse
              Summaryfalse
              Инвариантыele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
              obs-9: If Observation.specimen is a reference to Group, the group can only have specimens ((reference.resolve().exists() and reference.resolve() is Group) implies reference.resolve().member.entity.resolve().all($this is Specimen))
              74. Observation.device
              Определение

              A reference to the device that generates the measurements or the device settings for the device.

              КороткийA reference to the device that generates the measurements or the device settings for the device
              Комментарии

              Note that this is not meant to represent a device involved in the transmission of the result, e.g., a gateway. Such devices may be documented using the Provenance resource where relevant.

              Контроль0..1
              ТипReference(Device, DeviceMetric)
              Модификаторfalse
              Требуется поддержкаfalse
              Summaryfalse
              Инвариантыele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
              76. Observation.referenceRange
              Определение

              Guidance on how to interpret the value by comparison to a normal or recommended range. Multiple reference ranges are interpreted as an "OR". In other words, to represent two distinct target populations, two referenceRange elements would be used.

              КороткийProvides guide for interpretation
              Комментарии

              Most observations only have one generic reference range. Systems MAY choose to restrict to only supplying the relevant reference range based on knowledge about the patient (e.g., specific to the patient's age, gender, weight and other factors), but this might not be possible or appropriate. Whenever more than one reference range is supplied, the differences between them SHOULD be provided in the reference range and/or age properties.

              Контроль0..*
              ТипBackboneElement
              Модификаторfalse
              Требуется поддержкаfalse
              Summaryfalse
              Требования

              Knowing what values are considered "normal" can help evaluate the significance of a particular result. Need to be able to provide multiple reference ranges for different contexts.

              Инвариантыele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
              obs-3: Must have at least a low or a high or text (low.exists() or high.exists() or text.exists())
              78. Observation.referenceRange.id
              Определение

              Unique id for the element within a resource (for internal references). This may be any string value that does not contain spaces.

              КороткийUnique id for inter-element referencing
              Контроль0..1
              На этот элемент влияют следующие инварианты: ele-1
              Типstring
              Модификаторfalse
              Формат XMLВ формате XML это свойство представлено в качестве атрибута.
              Summaryfalse
              80. Observation.referenceRange.extension
              Определение

              May be used to represent additional information that is not part of the basic definition of the element. To make the use of extensions safe and managable, there is a strict set of governance applied to the definition and use of extensions. Though any implementer can define an extension, there is a set of requirements that SHALL be met as part of the definition of the extension.

              КороткийAdditional content defined by implementations
              Комментарии

              There can be no stigma associated with the use of extensions by any application, project, or standard - regardless of the institution or jurisdiction that uses or defines the extensions. The use of extensions is what allows the FHIR specification to retain a core level of simplicity for everyone.

              Контроль0..*
              ТипExtension
              Модификаторfalse
              Summaryfalse
              Альтернативные именаextensions, user content
              Инвариантыele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
              ext-1: Must have either extensions or value[x], not both (extension.exists() != value.exists())
              82. Observation.referenceRange.modifierExtension
              Определение

              May be used to represent additional information that is not part of the basic definition of the element and that modifies the understanding of the element in which it is contained and/or the understanding of the containing element's descendants. Usually modifier elements provide negation or qualification. To make the use of extensions safe and managable, there is a strict set of governance applied to the definition and use of extensions. Though any implementer can define an extension, there is a set of requirements that SHALL be met as part of the definition of the extension. Applications processing a resource are required to check for modifier extensions.

              Modifier extensions SHALL NOT change the meaning of any elements on Resource or DomainResource (including cannot change the meaning of modifierExtension itself).

              КороткийExtensions that cannot be ignored even if unrecognized
              Комментарии

              There can be no stigma associated with the use of extensions by any application, project, or standard - regardless of the institution or jurisdiction that uses or defines the extensions. The use of extensions is what allows the FHIR specification to retain a core level of simplicity for everyone.

              Контроль0..*
              ТипExtension
              Модификаторtrue потому что Modifier extensions are expected to modify the meaning or interpretation of the element that contains them
              Summarytrue
              Требования

              Modifier extensions allow for extensions that cannot be safely ignored to be clearly distinguished from the vast majority of extensions which can be safely ignored. This promotes interoperability by eliminating the need for implementers to prohibit the presence of extensions. For further information, see the definition of modifier extensions.

              Альтернативные именаextensions, user content, modifiers
              Инвариантыele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
              ext-1: Must have either extensions or value[x], not both (extension.exists() != value.exists())
              84. Observation.referenceRange.low
              Определение

              The value of the low bound of the reference range. The low bound of the reference range endpoint is inclusive of the value (e.g. reference range is >=5 - <=9). If the low bound is omitted, it is assumed to be meaningless (e.g. reference range is <=2.3).

              КороткийLow Range, if relevant
              Контроль0..1
              На этот элемент влияют следующие инварианты: obs-3
              ТипQuantity(SimpleQuantity)
              Модификаторfalse
              Требуется поддержкаfalse
              Summaryfalse
              Инвариантыele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
              86. Observation.referenceRange.high
              Определение

              The value of the high bound of the reference range. The high bound of the reference range endpoint is inclusive of the value (e.g. reference range is >=5 - <=9). If the high bound is omitted, it is assumed to be meaningless (e.g. reference range is >= 2.3).

              КороткийHigh Range, if relevant
              Контроль0..1
              На этот элемент влияют следующие инварианты: obs-3
              ТипQuantity(SimpleQuantity)
              Модификаторfalse
              Требуется поддержкаfalse
              Summaryfalse
              Инвариантыele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
              88. Observation.referenceRange.normalValue
              Определение

              The value of the normal value of the reference range.

              КороткийNormal value, if relevant
              Контроль0..1
              ПривязкаЕсли они не подходят, эти коды ДОЛЖНЫ быть взяты из ObservationReferenceRangeNormalValueCodes
              (extensible to http://hl7.org/fhir/ValueSet/observation-referencerange-normalvalue|5.0.0)

              Codes identifying the normal value of the observation.

              ТипCodeableConcept
              Модификаторfalse
              Требуется поддержкаfalse
              Summaryfalse
              Инвариантыele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
              90. Observation.referenceRange.type
              Определение

              Codes to indicate the what part of the targeted reference population it applies to. For example, the normal or therapeutic range.

              КороткийReference range qualifier
              Комментарии

              This SHOULD be populated if there is more than one range. If this element is not present then the normal range is assumed.

              Контроль0..1
              ПривязкаКоды СЛЕДУЕТ взять из ObservationReferenceRangeMeaningCodes
              (preferred to http://hl7.org/fhir/ValueSet/referencerange-meaning|5.0.0)

              Code for the meaning of a reference range.

              ТипCodeableConcept
              Модификаторfalse
              Требуется поддержкаfalse
              Summaryfalse
              Требования

              Need to be able to say what kind of reference range this is - normal, recommended, therapeutic, etc., - for proper interpretation.

              Инвариантыele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
              92. Observation.referenceRange.appliesTo
              Определение

              Codes to indicate the target population this reference range applies to. For example, a reference range may be based on the normal population or a particular sex or race. Multiple appliesTo are interpreted as an "AND" of the target populations. For example, to represent a target population of African American females, both a code of female and a code for African American would be used.

              КороткийReference range population
              Комментарии

              This SHOULD be populated if there is more than one range. If this element is not present then the normal population is assumed.

              Контроль0..*
              ПривязкаНапример, коды см. ObservationReferenceRangeAppliesToCodes
              (example to http://hl7.org/fhir/ValueSet/referencerange-appliesto|5.0.0)

              Codes identifying the population the reference range applies to.

              ТипCodeableConcept
              Модификаторfalse
              Требуется поддержкаfalse
              Summaryfalse
              Требования

              Need to be able to identify the target population for proper interpretation.

              Инвариантыele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
              94. Observation.referenceRange.age
              Определение

              The age at which this reference range is applicable. This is a neonatal age (e.g. number of weeks at term) if the meaning says so.

              КороткийApplicable age range, if relevant
              Контроль0..1
              ТипRange
              Модификаторfalse
              Требуется поддержкаfalse
              Summaryfalse
              Требования

              Some analytes vary greatly over age.

              Инвариантыele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
              96. Observation.referenceRange.text
              Определение

              Text based reference range in an observation which may be used when a quantitative range is not appropriate for an observation. An example would be a reference value of "Negative" or a list or table of "normals".

              КороткийText based reference range in an observation
              Контроль0..1
              На этот элемент влияют следующие инварианты: obs-3
              Типmarkdown
              Модификаторfalse
              Примитивное значениеЭтот примитивный элемент может присутствовать или отсутствовать, или быть замененным расширением
              Требуется поддержкаfalse
              Summaryfalse
              Инвариантыele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
              98. Observation.hasMember
              Определение

              This observation is a group observation (e.g. a battery, a panel of tests, a set of vital sign measurements) that includes the target as a member of the group.

              КороткийRelated resource that belongs to the Observation group
              Комментарии

              When using this element, an observation will typically have either a value or a set of related resources, although both may be present in some cases. For a discussion on the ways Observations can assembled in groups together, see Notes below. Note that a system may calculate results from QuestionnaireResponse into a final score and represent the score as an Observation.

              Контроль0..*
              ТипReference(Observation, QuestionnaireResponse, MolecularSequence)
              Модификаторfalse
              Требуется поддержкаfalse
              Summarytrue
              Инвариантыele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
              100. Observation.derivedFrom
              Определение

              The target resource that represents a measurement from which this observation value is derived. For example, a calculated anion gap or a fetal measurement based on an ultrasound image.

              КороткийRelated resource from which the observation is made
              Комментарии

              All the reference choices that are listed in this element can represent clinical observations and other measurements that may be the source for a derived value. The most common reference will be another Observation. For a discussion on the ways Observations can assembled in groups together, see Notes below.

              Контроль0..*
              ТипReference(DocumentReference, ImagingStudy, ImagingSelection, QuestionnaireResponse, Observation, MolecularSequence, GenomicStudy)
              Модификаторfalse
              Требуется поддержкаfalse
              Summarytrue
              Инвариантыele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
              102. Observation.component
              Определение

              Some observations have multiple component observations. These component observations are expressed as separate code value pairs that share the same attributes. Examples include systolic and diastolic component observations for blood pressure measurement and multiple component observations for genetics observations.

              КороткийComponent results
              Комментарии

              For a discussion on the ways Observations can be assembled in groups together see Notes below.

              Контроль0..*
              На этот элемент влияют следующие инварианты: obs-7
              ТипBackboneElement
              Модификаторfalse
              Требуется поддержкаfalse
              Summarytrue
              Требования

              Component observations share the same attributes in the Observation resource as the primary observation and are always treated a part of a single observation (they are not separable). However, the reference range for the primary observation value is not inherited by the component values and is required when appropriate for each component observation.

              Инвариантыele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
              SlicingЭтот элемент представляет набор разрезов на Observation.component. Разрезы бываютНе упорядочено и Open, и могут быть дифференцированы с помощью следующих дискриминаторов:
              • pattern @ code
              • 104. Observation.component.id
                Определение

                Unique id for the element within a resource (for internal references). This may be any string value that does not contain spaces.

                КороткийUnique id for inter-element referencing
                Контроль0..1
                На этот элемент влияют следующие инварианты: ele-1
                Типstring
                Модификаторfalse
                Формат XMLВ формате XML это свойство представлено в качестве атрибута.
                Summaryfalse
                106. Observation.component.extension
                Определение

                May be used to represent additional information that is not part of the basic definition of the element. To make the use of extensions safe and managable, there is a strict set of governance applied to the definition and use of extensions. Though any implementer can define an extension, there is a set of requirements that SHALL be met as part of the definition of the extension.

                КороткийAdditional content defined by implementations
                Комментарии

                There can be no stigma associated with the use of extensions by any application, project, or standard - regardless of the institution or jurisdiction that uses or defines the extensions. The use of extensions is what allows the FHIR specification to retain a core level of simplicity for everyone.

                Контроль0..*
                ТипExtension
                Модификаторfalse
                Summaryfalse
                Альтернативные именаextensions, user content
                Инвариантыele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
                ext-1: Must have either extensions or value[x], not both (extension.exists() != value.exists())
                108. Observation.component.modifierExtension
                Определение

                May be used to represent additional information that is not part of the basic definition of the element and that modifies the understanding of the element in which it is contained and/or the understanding of the containing element's descendants. Usually modifier elements provide negation or qualification. To make the use of extensions safe and managable, there is a strict set of governance applied to the definition and use of extensions. Though any implementer can define an extension, there is a set of requirements that SHALL be met as part of the definition of the extension. Applications processing a resource are required to check for modifier extensions.

                Modifier extensions SHALL NOT change the meaning of any elements on Resource or DomainResource (including cannot change the meaning of modifierExtension itself).

                КороткийExtensions that cannot be ignored even if unrecognized
                Комментарии

                There can be no stigma associated with the use of extensions by any application, project, or standard - regardless of the institution or jurisdiction that uses or defines the extensions. The use of extensions is what allows the FHIR specification to retain a core level of simplicity for everyone.

                Контроль0..*
                ТипExtension
                Модификаторtrue потому что Modifier extensions are expected to modify the meaning or interpretation of the element that contains them
                Summarytrue
                Требования

                Modifier extensions allow for extensions that cannot be safely ignored to be clearly distinguished from the vast majority of extensions which can be safely ignored. This promotes interoperability by eliminating the need for implementers to prohibit the presence of extensions. For further information, see the definition of modifier extensions.

                Альтернативные именаextensions, user content, modifiers
                Инвариантыele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
                ext-1: Must have either extensions or value[x], not both (extension.exists() != value.exists())
                110. Observation.component.code
                Определение

                Describes what was observed. Sometimes this is called the observation "code".

                КороткийType of component observation (code / type)
                Комментарии

                All code-value and component.code-component.value pairs need to be taken into account to correctly understand the meaning of the observation.

                Контроль1..1
                На этот элемент влияют следующие инварианты: obs-7
                ПривязкаНапример, коды см. LOINCCodes
                (example to http://hl7.org/fhir/ValueSet/observation-codes|5.0.0)

                Codes identifying names of simple observations.

                ТипCodeableConcept
                Модификаторfalse
                Требуется поддержкаfalse
                Summarytrue
                Требования

                Knowing what kind of observation is being made is essential to understanding the observation.

                Инвариантыele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
                112. Observation.component.value[x]
                Определение

                The information determined as a result of making the observation, if the information has a simple value.

                КороткийActual component result
                Комментарии

                Used when observation has a set of component observations:

                • An observation may have both a value (e.g. an Apgar score) and component observations (the observations from which the Apgar score was derived).
                • If a value is present, the datatype for this element should be determined by the code.
                • CodeableConcept with just a text would be used instead of a string if the field was usually coded, or if the type associated with the code defines a coded value.
                • Attachment is used if the observation result value is a binary file such as an image. If the observation result value is derived from the binary file (for example 'X' detected and here is the the proof in this image), the binary file may be directly represented using DocumentReference and referenced by derivedFrom.
                • If a value is present, the datatype for this element should be determined by the code.
                • CodeableConcept with just a text would be used instead of a string if the field was usually coded, or if the type associated with the code defines a coded value.
                • Attachment is used if the observation result value is a binary file such as an image. If the observation result value is derived from the binary file (for example 'X' detected and here is the the proof in this image), the binary file may be directly represented using DocumentReference and referenced by derivedFrom.
                • The usage of valueReference is restricted to the MolecularSequence resource when used as a definitional resource, not as a patient-specific finding. .
                • For additional guidance, see the Notes section below.
                Контроль0..1
                ТипВыбор: Quantity, CodeableConcept, string, boolean, integer, Range, Ratio, SampledData, time, dateTime, Period, Attachment, Reference(MolecularSequence)
                [x] ЗаметкаСмотретьВыбор типов данныхдля дополнительной информации о том, как использовать [x]
                Модификаторfalse
                Примитивное значениеЭтот примитивный элемент может присутствовать или отсутствовать, или быть замененным расширением
                Требуется поддержкаfalse
                Summarytrue
                Требования

                An observation exists to have a value, though it might not if it is in error, or if it represents a group of observations.

                Инвариантыele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
                114. Observation.component.dataAbsentReason
                Определение

                Provides a reason why the expected value in the element Observation.component.value[x] is missing.

                КороткийWhy the component result is missing
                Комментарии

                "Null" or exceptional values can be represented two ways in FHIR Observations. One way is to simply include them in the value set and represent the exceptions in the value. For example, measurement values for a serology test could be "detected", "not detected", "inconclusive", or "test not done".

                The alternate way is to use the value element for actual observations and use the explicit dataAbsentReason element to record exceptional values. For example, the dataAbsentReason code "error" could be used when the measurement was not completed. Because of these options, use-case agreements are required to interpret general observations for exceptional values.

                Контроль0..1
                ПривязкаЕсли они не подходят, эти коды ДОЛЖНЫ быть взяты из DataAbsentReason
                (extensible to http://hl7.org/fhir/ValueSet/data-absent-reason|5.0.0)

                Codes specifying why the result (Observation.value[x]) is missing.

                ТипCodeableConcept
                Модификаторfalse
                Требуется поддержкаfalse
                Summaryfalse
                Требования

                For many results it is necessary to handle exceptional values in measurements.

                Инвариантыele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
                116. Observation.component.interpretation
                Определение

                A categorical assessment of an observation value. For example, high, low, normal.

                КороткийHigh, low, normal, etc
                Комментарии

                Historically used for laboratory results (known as 'abnormal flag' ), its use extends to other use cases where coded interpretations are relevant. Often reported as one or more simple compact codes this element is often placed adjacent to the result value in reports and flow sheets to signal the meaning/normalcy status of the result.

                Контроль0..*
                ПривязкаЕсли они не подходят, эти коды ДОЛЖНЫ быть взяты из ObservationInterpretationCodes
                (extensible to http://hl7.org/fhir/ValueSet/observation-interpretation|5.0.0)

                Codes identifying interpretations of observations.

                ТипCodeableConcept
                Модификаторfalse
                Требуется поддержкаfalse
                Summaryfalse
                Требования

                For some results, particularly numeric results, an interpretation is necessary to fully understand the significance of a result.

                Альтернативные именаAbnormal Flag
                Инвариантыele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
                118. Observation.component.referenceRange
                Определение

                Guidance on how to interpret the value by comparison to a normal or recommended range.

                КороткийProvides guide for interpretation of component result
                Комментарии

                Most observations only have one generic reference range. Systems MAY choose to restrict to only supplying the relevant reference range based on knowledge about the patient (e.g., specific to the patient's age, gender, weight and other factors), but this might not be possible or appropriate. Whenever more than one reference range is supplied, the differences between them SHOULD be provided in the reference range and/or age properties.

                Контроль0..*
                ТипСмотретьttp://hl7.org/fhir/StructureDefinition/Observation#Observation.referenceRange
                Модификаторfalse
                Требуется поддержкаfalse
                Summaryfalse
                Требования

                Knowing what values are considered "normal" can help evaluate the significance of a particular result. Need to be able to provide multiple reference ranges for different contexts.

                Инвариантыele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
                120. Observation.component:birthMeasure
                Название разрезаbirthMeasure
                Определение

                Some observations have multiple component observations. These component observations are expressed as separate code value pairs that share the same attributes. Examples include systolic and diastolic component observations for blood pressure measurement and multiple component observations for genetics observations.

                КороткийComponent results
                Комментарии

                For a discussion on the ways Observations can be assembled in groups together see Notes below.

                Контроль0..*
                На этот элемент влияют следующие инварианты: obs-7
                ТипBackboneElement
                Модификаторfalse
                Требуется поддержкаtrue
                Summarytrue
                Требования

                Component observations share the same attributes in the Observation resource as the primary observation and are always treated a part of a single observation (they are not separable). However, the reference range for the primary observation value is not inherited by the component values and is required when appropriate for each component observation.

                Инвариантыele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
                122. Observation.component:birthMeasure.id
                Определение

                Unique id for the element within a resource (for internal references). This may be any string value that does not contain spaces.

                КороткийUnique id for inter-element referencing
                Контроль0..1
                На этот элемент влияют следующие инварианты: ele-1
                Типstring
                Модификаторfalse
                Формат XMLВ формате XML это свойство представлено в качестве атрибута.
                Summaryfalse
                124. Observation.component:birthMeasure.extension
                Определение

                May be used to represent additional information that is not part of the basic definition of the element. To make the use of extensions safe and managable, there is a strict set of governance applied to the definition and use of extensions. Though any implementer can define an extension, there is a set of requirements that SHALL be met as part of the definition of the extension.

                КороткийAdditional content defined by implementations
                Комментарии

                There can be no stigma associated with the use of extensions by any application, project, or standard - regardless of the institution or jurisdiction that uses or defines the extensions. The use of extensions is what allows the FHIR specification to retain a core level of simplicity for everyone.

                Контроль0..*
                ТипExtension
                Модификаторfalse
                Summaryfalse
                Альтернативные именаextensions, user content
                Инвариантыele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
                ext-1: Must have either extensions or value[x], not both (extension.exists() != value.exists())
                126. Observation.component:birthMeasure.modifierExtension
                Определение

                May be used to represent additional information that is not part of the basic definition of the element and that modifies the understanding of the element in which it is contained and/or the understanding of the containing element's descendants. Usually modifier elements provide negation or qualification. To make the use of extensions safe and managable, there is a strict set of governance applied to the definition and use of extensions. Though any implementer can define an extension, there is a set of requirements that SHALL be met as part of the definition of the extension. Applications processing a resource are required to check for modifier extensions.

                Modifier extensions SHALL NOT change the meaning of any elements on Resource or DomainResource (including cannot change the meaning of modifierExtension itself).

                КороткийExtensions that cannot be ignored even if unrecognized
                Комментарии

                There can be no stigma associated with the use of extensions by any application, project, or standard - regardless of the institution or jurisdiction that uses or defines the extensions. The use of extensions is what allows the FHIR specification to retain a core level of simplicity for everyone.

                Контроль0..*
                ТипExtension
                Модификаторtrue потому что Modifier extensions are expected to modify the meaning or interpretation of the element that contains them
                Summarytrue
                Требования

                Modifier extensions allow for extensions that cannot be safely ignored to be clearly distinguished from the vast majority of extensions which can be safely ignored. This promotes interoperability by eliminating the need for implementers to prohibit the presence of extensions. For further information, see the definition of modifier extensions.

                Альтернативные именаextensions, user content, modifiers
                Инвариантыele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
                ext-1: Must have either extensions or value[x], not both (extension.exists() != value.exists())
                128. Observation.component:birthMeasure.code
                Определение

                Describes what was observed. Sometimes this is called the observation "code".

                КороткийType of component
                Комментарии

                All code-value and component.code-component.value pairs need to be taken into account to correctly understand the meaning of the observation.

                Контроль1..1
                На этот элемент влияют следующие инварианты: obs-7
                ПривязкаКоды ДОЛЖНЫ быть взяты из LOINCCodes
                (required to http://hl7.org/fhir/ValueSet/observation-codes|5.0.0)
                ТипCodeableConcept
                Модификаторfalse
                Требуется поддержкаtrue
                Summarytrue
                Требования

                Knowing what kind of observation is being made is essential to understanding the observation.

                Инвариантыele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
                130. Observation.component:birthMeasure.value[x]
                Определение

                The information determined as a result of making the observation, if the information has a simple value.

                КороткийActual component result
                Комментарии

                Used when observation has a set of component observations:

                • An observation may have both a value (e.g. an Apgar score) and component observations (the observations from which the Apgar score was derived).
                • If a value is present, the datatype for this element should be determined by the code.
                • CodeableConcept with just a text would be used instead of a string if the field was usually coded, or if the type associated with the code defines a coded value.
                • Attachment is used if the observation result value is a binary file such as an image. If the observation result value is derived from the binary file (for example 'X' detected and here is the the proof in this image), the binary file may be directly represented using DocumentReference and referenced by derivedFrom.
                • If a value is present, the datatype for this element should be determined by the code.
                • CodeableConcept with just a text would be used instead of a string if the field was usually coded, or if the type associated with the code defines a coded value.
                • Attachment is used if the observation result value is a binary file such as an image. If the observation result value is derived from the binary file (for example 'X' detected and here is the the proof in this image), the binary file may be directly represented using DocumentReference and referenced by derivedFrom.
                • The usage of valueReference is restricted to the MolecularSequence resource when used as a definitional resource, not as a patient-specific finding. .
                • For additional guidance, see the Notes section below.
                Контроль0..1
                ТипВыбор: Quantity, CodeableConcept, string, boolean, integer, Range, Ratio, SampledData, time, dateTime, Period, Attachment, Reference(MolecularSequence)
                [x] ЗаметкаСмотретьВыбор типов данныхдля дополнительной информации о том, как использовать [x]
                Модификаторfalse
                Примитивное значениеЭтот примитивный элемент может присутствовать или отсутствовать, или быть замененным расширением
                Требуется поддержкаfalse
                Summarytrue
                Требования

                An observation exists to have a value, though it might not if it is in error, or if it represents a group of observations.

                Инвариантыele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
                SlicingЭтот элемент представляет набор разрезов на Observation.component.value[x]. Разрезы бываютНе упорядочено и Open, и могут быть дифференцированы с помощью следующих дискриминаторов:
                • type @ $this
                • 132. Observation.component:birthMeasure.value[x]:valueQuantity
                  Название разрезаvalueQuantity
                  Определение

                  The information determined as a result of making the observation, if the information has a simple value.

                  КороткийРост, вес ребенка при рождении
                  Комментарии

                  Used when observation has a set of component observations:

                  • An observation may have both a value (e.g. an Apgar score) and component observations (the observations from which the Apgar score was derived).
                  • If a value is present, the datatype for this element should be determined by the code.
                  • CodeableConcept with just a text would be used instead of a string if the field was usually coded, or if the type associated with the code defines a coded value.
                  • Attachment is used if the observation result value is a binary file such as an image. If the observation result value is derived from the binary file (for example 'X' detected and here is the the proof in this image), the binary file may be directly represented using DocumentReference and referenced by derivedFrom.
                  • If a value is present, the datatype for this element should be determined by the code.
                  • CodeableConcept with just a text would be used instead of a string if the field was usually coded, or if the type associated with the code defines a coded value.
                  • Attachment is used if the observation result value is a binary file such as an image. If the observation result value is derived from the binary file (for example 'X' detected and here is the the proof in this image), the binary file may be directly represented using DocumentReference and referenced by derivedFrom.
                  • The usage of valueReference is restricted to the MolecularSequence resource when used as a definitional resource, not as a patient-specific finding. .
                  • For additional guidance, see the Notes section below.
                  Контроль0..1
                  ТипQuantity
                  [x] ЗаметкаСмотретьВыбор типов данныхдля дополнительной информации о том, как использовать [x]
                  Модификаторfalse
                  Требуется поддержкаtrue
                  Summarytrue
                  Требования

                  An observation exists to have a value, though it might not if it is in error, or if it represents a group of observations.

                  Инвариантыele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
                  134. Observation.component:birthMeasure.value[x]:valueQuantity.id
                  Определение

                  Unique id for the element within a resource (for internal references). This may be any string value that does not contain spaces.

                  КороткийUnique id for inter-element referencing
                  Контроль0..1
                  На этот элемент влияют следующие инварианты: ele-1
                  Типid
                  Модификаторfalse
                  Формат XMLВ формате XML это свойство представлено в качестве атрибута.
                  Summaryfalse
                  136. Observation.component:birthMeasure.value[x]:valueQuantity.extension
                  Определение

                  May be used to represent additional information that is not part of the basic definition of the element. To make the use of extensions safe and managable, there is a strict set of governance applied to the definition and use of extensions. Though any implementer can define an extension, there is a set of requirements that SHALL be met as part of the definition of the extension.

                  КороткийAdditional content defined by implementations
                  Комментарии

                  There can be no stigma associated with the use of extensions by any application, project, or standard - regardless of the institution or jurisdiction that uses or defines the extensions. The use of extensions is what allows the FHIR specification to retain a core level of simplicity for everyone.

                  Контроль0..*
                  ТипExtension
                  Модификаторfalse
                  Summaryfalse
                  Альтернативные именаextensions, user content
                  Инвариантыele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
                  ext-1: Must have either extensions or value[x], not both (extension.exists() != value.exists())
                  SlicingЭтот элемент представляет набор разрезов на Observation.component.value[x].extension. Разрезы бываютНе упорядочено и Open, и могут быть дифференцированы с помощью следующих дискриминаторов:
                  • value @ url
                  • 138. Observation.component:birthMeasure.value[x]:valueQuantity.value
                    Определение

                    The value of the measured amount. The value includes an implicit precision in the presentation of the value.

                    КороткийЧисловое значение (с неявной точностью)
                    Комментарии

                    The implicit precision in the value should always be honored. Monetary values have their own rules for handling precision (refer to standard accounting text books).

                    Контроль0..1
                    Типdecimal
                    Модификаторfalse
                    Примитивное значениеЭтот примитивный элемент может присутствовать или отсутствовать, или быть замененным расширением
                    Требуется поддержкаtrue
                    Summarytrue
                    Требования

                    Precision is handled implicitly in almost all cases of measurement.

                    Инвариантыele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
                    140. Observation.component:birthMeasure.value[x]:valueQuantity.comparator
                    Определение

                    How the value should be understood and represented - whether the actual value is greater or less than the stated value due to measurement issues; e.g. if the comparator is "<" , then the real value is < stated value.

                    Короткий< | <= | >= | > | ad - how to understand the value
                    Контроль0..1
                    ПривязкаКоды ДОЛЖНЫ быть взяты из QuantityComparator
                    (required to http://hl7.org/fhir/ValueSet/quantity-comparator|5.0.0)

                    How the Quantity should be understood and represented.

                    Типcode
                    Модификаторtrue потому что This is labeled as "Is Modifier" because the comparator modifies the interpretation of the value significantly. If there is no comparator, then there is no modification of the value
                    Примитивное значениеЭтот примитивный элемент может присутствовать или отсутствовать, или быть замененным расширением
                    Summarytrue
                    Требования

                    Need a framework for handling measures where the value is <5ug/L or >400mg/L due to the limitations of measuring methodology.

                    Значение при отсутствииIf there is no comparator, then there is no modification of the value
                    Инвариантыele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
                    142. Observation.component:birthMeasure.value[x]:valueQuantity.unit
                    Определение

                    A human-readable form of the unit.

                    КороткийUnit representation
                    Контроль0..1
                    Типstring
                    Модификаторfalse
                    Примитивное значениеЭтот примитивный элемент может присутствовать или отсутствовать, или быть замененным расширением
                    Требуется поддержкаtrue
                    Summarytrue
                    Требования

                    There are many representations for units of measure and in many contexts, particular representations are fixed and required. I.e. mcg for micrograms.

                    Инвариантыele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
                    144. Observation.component:birthMeasure.value[x]:valueQuantity.system
                    Определение

                    The identification of the system that provides the coded form of the unit.

                    КороткийSystem that defines coded unit form
                    Контроль0..1
                    На этот элемент влияют следующие инварианты: qty-3
                    Типuri
                    Модификаторfalse
                    Примитивное значениеЭтот примитивный элемент может присутствовать или отсутствовать, или быть замененным расширением
                    Требуется поддержкаtrue
                    Summarytrue
                    Требования

                    Need to know the system that defines the coded form of the unit.

                    Инвариантыele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
                    146. Observation.component:birthMeasure.value[x]:valueQuantity.code
                    Определение

                    A computer processable form of the unit in some unit representation system.

                    КороткийCoded form of the unit
                    Комментарии

                    The preferred system is UCUM, but SNOMED CT can also be used (for customary units) or ISO 4217 for currency. The context of use may additionally require a code from a particular system.

                    Контроль0..1
                    На этот элемент влияют следующие инварианты: qty-3
                    ПривязкаКоды ДОЛЖНЫ быть взяты из LOINC_CodesVS (0.1.0)
                    (required to https://terminology.dhp.uz/ValueSet/loinc-codes-vs|0.1.0)
                    Типcode
                    Модификаторfalse
                    Примитивное значениеЭтот примитивный элемент может присутствовать или отсутствовать, или быть замененным расширением
                    Требуется поддержкаtrue
                    Summarytrue
                    Требования

                    Need a computable form of the unit that is fixed across all forms. UCUM provides this for quantities, but SNOMED CT provides many units of interest.

                    Инвариантыele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
                    148. Observation.component:birthMeasure.dataAbsentReason
                    Определение

                    Provides a reason why the expected value in the element Observation.component.value[x] is missing.

                    КороткийWhy the component result is missing
                    Комментарии

                    "Null" or exceptional values can be represented two ways in FHIR Observations. One way is to simply include them in the value set and represent the exceptions in the value. For example, measurement values for a serology test could be "detected", "not detected", "inconclusive", or "test not done".

                    The alternate way is to use the value element for actual observations and use the explicit dataAbsentReason element to record exceptional values. For example, the dataAbsentReason code "error" could be used when the measurement was not completed. Because of these options, use-case agreements are required to interpret general observations for exceptional values.

                    Контроль0..1
                    ПривязкаЕсли они не подходят, эти коды ДОЛЖНЫ быть взяты из DataAbsentReason
                    (extensible to http://hl7.org/fhir/ValueSet/data-absent-reason|5.0.0)

                    Codes specifying why the result (Observation.value[x]) is missing.

                    ТипCodeableConcept
                    Модификаторfalse
                    Требуется поддержкаfalse
                    Summaryfalse
                    Требования

                    For many results it is necessary to handle exceptional values in measurements.

                    Инвариантыele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
                    150. Observation.component:birthMeasure.interpretation
                    Определение

                    A categorical assessment of an observation value. For example, high, low, normal.

                    КороткийHigh, low, normal, etc
                    Комментарии

                    Historically used for laboratory results (known as 'abnormal flag' ), its use extends to other use cases where coded interpretations are relevant. Often reported as one or more simple compact codes this element is often placed adjacent to the result value in reports and flow sheets to signal the meaning/normalcy status of the result.

                    Контроль0..*
                    ПривязкаЕсли они не подходят, эти коды ДОЛЖНЫ быть взяты из ObservationInterpretationCodes
                    (extensible to http://hl7.org/fhir/ValueSet/observation-interpretation|5.0.0)

                    Codes identifying interpretations of observations.

                    ТипCodeableConcept
                    Модификаторfalse
                    Требуется поддержкаfalse
                    Summaryfalse
                    Требования

                    For some results, particularly numeric results, an interpretation is necessary to fully understand the significance of a result.

                    Альтернативные именаAbnormal Flag
                    Инвариантыele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
                    152. Observation.component:birthMeasure.referenceRange
                    Определение

                    Guidance on how to interpret the value by comparison to a normal or recommended range.

                    КороткийProvides guide for interpretation of component result
                    Комментарии

                    Most observations only have one generic reference range. Systems MAY choose to restrict to only supplying the relevant reference range based on knowledge about the patient (e.g., specific to the patient's age, gender, weight and other factors), but this might not be possible or appropriate. Whenever more than one reference range is supplied, the differences between them SHOULD be provided in the reference range and/or age properties.

                    Контроль0..*
                    ТипСмотретьttp://hl7.org/fhir/StructureDefinition/Observation#Observation.referenceRange
                    Модификаторfalse
                    Требуется поддержкаfalse
                    Summaryfalse
                    Требования

                    Knowing what values are considered "normal" can help evaluate the significance of a particular result. Need to be able to provide multiple reference ranges for different contexts.

                    Инвариантыele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
                    154. Observation.component:lifeCrit
                    Название разрезаlifeCrit
                    Определение

                    Some observations have multiple component observations. These component observations are expressed as separate code value pairs that share the same attributes. Examples include systolic and diastolic component observations for blood pressure measurement and multiple component observations for genetics observations.

                    КороткийComponent results
                    Комментарии

                    For a discussion on the ways Observations can be assembled in groups together see Notes below.

                    Контроль0..1
                    На этот элемент влияют следующие инварианты: obs-7
                    ТипBackboneElement
                    Модификаторfalse
                    Требуется поддержкаtrue
                    Summarytrue
                    Требования

                    Component observations share the same attributes in the Observation resource as the primary observation and are always treated a part of a single observation (they are not separable). However, the reference range for the primary observation value is not inherited by the component values and is required when appropriate for each component observation.

                    Инвариантыele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
                    156. Observation.component:lifeCrit.id
                    Определение

                    Unique id for the element within a resource (for internal references). This may be any string value that does not contain spaces.

                    КороткийUnique id for inter-element referencing
                    Контроль0..1
                    На этот элемент влияют следующие инварианты: ele-1
                    Типstring
                    Модификаторfalse
                    Формат XMLВ формате XML это свойство представлено в качестве атрибута.
                    Summaryfalse
                    158. Observation.component:lifeCrit.extension
                    Определение

                    May be used to represent additional information that is not part of the basic definition of the element. To make the use of extensions safe and managable, there is a strict set of governance applied to the definition and use of extensions. Though any implementer can define an extension, there is a set of requirements that SHALL be met as part of the definition of the extension.

                    КороткийAdditional content defined by implementations
                    Комментарии

                    There can be no stigma associated with the use of extensions by any application, project, or standard - regardless of the institution or jurisdiction that uses or defines the extensions. The use of extensions is what allows the FHIR specification to retain a core level of simplicity for everyone.

                    Контроль0..*
                    ТипExtension
                    Модификаторfalse
                    Summaryfalse
                    Альтернативные именаextensions, user content
                    Инвариантыele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
                    ext-1: Must have either extensions or value[x], not both (extension.exists() != value.exists())
                    160. Observation.component:lifeCrit.modifierExtension
                    Определение

                    May be used to represent additional information that is not part of the basic definition of the element and that modifies the understanding of the element in which it is contained and/or the understanding of the containing element's descendants. Usually modifier elements provide negation or qualification. To make the use of extensions safe and managable, there is a strict set of governance applied to the definition and use of extensions. Though any implementer can define an extension, there is a set of requirements that SHALL be met as part of the definition of the extension. Applications processing a resource are required to check for modifier extensions.

                    Modifier extensions SHALL NOT change the meaning of any elements on Resource or DomainResource (including cannot change the meaning of modifierExtension itself).

                    КороткийExtensions that cannot be ignored even if unrecognized
                    Комментарии

                    There can be no stigma associated with the use of extensions by any application, project, or standard - regardless of the institution or jurisdiction that uses or defines the extensions. The use of extensions is what allows the FHIR specification to retain a core level of simplicity for everyone.

                    Контроль0..*
                    ТипExtension
                    Модификаторtrue потому что Modifier extensions are expected to modify the meaning or interpretation of the element that contains them
                    Summarytrue
                    Требования

                    Modifier extensions allow for extensions that cannot be safely ignored to be clearly distinguished from the vast majority of extensions which can be safely ignored. This promotes interoperability by eliminating the need for implementers to prohibit the presence of extensions. For further information, see the definition of modifier extensions.

                    Альтернативные именаextensions, user content, modifiers
                    Инвариантыele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
                    ext-1: Must have either extensions or value[x], not both (extension.exists() != value.exists())
                    162. Observation.component:lifeCrit.code
                    Определение

                    Describes what was observed. Sometimes this is called the observation "code".

                    КороткийType of component observation (code / type)
                    Комментарии

                    All code-value and component.code-component.value pairs need to be taken into account to correctly understand the meaning of the observation.

                    Контроль1..1
                    На этот элемент влияют следующие инварианты: obs-7
                    ПривязкаКоды ДОЛЖНЫ быть взяты из LifeCritVS (0.1.0)
                    (required to https://terminology.dhp.uz/ValueSet/lifecrit-vs|0.1.0)
                    ТипCodeableConcept
                    Модификаторfalse
                    Требуется поддержкаtrue
                    Summarytrue
                    Требования

                    Knowing what kind of observation is being made is essential to understanding the observation.

                    Инвариантыele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
                    164. Observation.component:lifeCrit.value[x]
                    Определение

                    The information determined as a result of making the observation, if the information has a simple value.

                    КороткийActual component result
                    Комментарии

                    Used when observation has a set of component observations:

                    • An observation may have both a value (e.g. an Apgar score) and component observations (the observations from which the Apgar score was derived).
                    • If a value is present, the datatype for this element should be determined by the code.
                    • CodeableConcept with just a text would be used instead of a string if the field was usually coded, or if the type associated with the code defines a coded value.
                    • Attachment is used if the observation result value is a binary file such as an image. If the observation result value is derived from the binary file (for example 'X' detected and here is the the proof in this image), the binary file may be directly represented using DocumentReference and referenced by derivedFrom.
                    • If a value is present, the datatype for this element should be determined by the code.
                    • CodeableConcept with just a text would be used instead of a string if the field was usually coded, or if the type associated with the code defines a coded value.
                    • Attachment is used if the observation result value is a binary file such as an image. If the observation result value is derived from the binary file (for example 'X' detected and here is the the proof in this image), the binary file may be directly represented using DocumentReference and referenced by derivedFrom.
                    • The usage of valueReference is restricted to the MolecularSequence resource when used as a definitional resource, not as a patient-specific finding. .
                    • For additional guidance, see the Notes section below.
                    Контроль0..1
                    ТипВыбор: Quantity, CodeableConcept, string, boolean, integer, Range, Ratio, SampledData, time, dateTime, Period, Attachment, Reference(MolecularSequence)
                    [x] ЗаметкаСмотретьВыбор типов данныхдля дополнительной информации о том, как использовать [x]
                    Модификаторfalse
                    Примитивное значениеЭтот примитивный элемент может присутствовать или отсутствовать, или быть замененным расширением
                    Требуется поддержкаfalse
                    Summarytrue
                    Требования

                    An observation exists to have a value, though it might not if it is in error, or if it represents a group of observations.

                    Инвариантыele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
                    SlicingЭтот элемент представляет набор разрезов на Observation.component.value[x]. Разрезы бываютНе упорядочено и Open, и могут быть дифференцированы с помощью следующих дискриминаторов:
                    • type @ $this
                    • 166. Observation.component:lifeCrit.value[x]:valueBoolean
                      Название разрезаvalueBoolean
                      Определение

                      The information determined as a result of making the observation, if the information has a simple value.

                      КороткийТип жизненные критерии
                      Комментарии

                      Used when observation has a set of component observations:

                      • An observation may have both a value (e.g. an Apgar score) and component observations (the observations from which the Apgar score was derived).
                      • If a value is present, the datatype for this element should be determined by the code.
                      • CodeableConcept with just a text would be used instead of a string if the field was usually coded, or if the type associated with the code defines a coded value.
                      • Attachment is used if the observation result value is a binary file such as an image. If the observation result value is derived from the binary file (for example 'X' detected and here is the the proof in this image), the binary file may be directly represented using DocumentReference and referenced by derivedFrom.
                      • If a value is present, the datatype for this element should be determined by the code.
                      • CodeableConcept with just a text would be used instead of a string if the field was usually coded, or if the type associated with the code defines a coded value.
                      • Attachment is used if the observation result value is a binary file such as an image. If the observation result value is derived from the binary file (for example 'X' detected and here is the the proof in this image), the binary file may be directly represented using DocumentReference and referenced by derivedFrom.
                      • The usage of valueReference is restricted to the MolecularSequence resource when used as a definitional resource, not as a patient-specific finding. .
                      • For additional guidance, see the Notes section below.
                      Контроль0..1
                      Типboolean
                      [x] ЗаметкаСмотретьВыбор типов данныхдля дополнительной информации о том, как использовать [x]
                      Модификаторfalse
                      Примитивное значениеЭтот примитивный элемент может присутствовать или отсутствовать, или быть замененным расширением
                      Требуется поддержкаtrue
                      Summarytrue
                      Требования

                      An observation exists to have a value, though it might not if it is in error, or if it represents a group of observations.

                      Инвариантыele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
                      168. Observation.component:lifeCrit.dataAbsentReason
                      Определение

                      Provides a reason why the expected value in the element Observation.component.value[x] is missing.

                      КороткийWhy the component result is missing
                      Комментарии

                      "Null" or exceptional values can be represented two ways in FHIR Observations. One way is to simply include them in the value set and represent the exceptions in the value. For example, measurement values for a serology test could be "detected", "not detected", "inconclusive", or "test not done".

                      The alternate way is to use the value element for actual observations and use the explicit dataAbsentReason element to record exceptional values. For example, the dataAbsentReason code "error" could be used when the measurement was not completed. Because of these options, use-case agreements are required to interpret general observations for exceptional values.

                      Контроль0..1
                      ПривязкаЕсли они не подходят, эти коды ДОЛЖНЫ быть взяты из DataAbsentReason
                      (extensible to http://hl7.org/fhir/ValueSet/data-absent-reason|5.0.0)

                      Codes specifying why the result (Observation.value[x]) is missing.

                      ТипCodeableConcept
                      Модификаторfalse
                      Требуется поддержкаfalse
                      Summaryfalse
                      Требования

                      For many results it is necessary to handle exceptional values in measurements.

                      Инвариантыele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
                      170. Observation.component:lifeCrit.interpretation
                      Определение

                      A categorical assessment of an observation value. For example, high, low, normal.

                      КороткийHigh, low, normal, etc
                      Комментарии

                      Historically used for laboratory results (known as 'abnormal flag' ), its use extends to other use cases where coded interpretations are relevant. Often reported as one or more simple compact codes this element is often placed adjacent to the result value in reports and flow sheets to signal the meaning/normalcy status of the result.

                      Контроль0..*
                      ПривязкаЕсли они не подходят, эти коды ДОЛЖНЫ быть взяты из ObservationInterpretationCodes
                      (extensible to http://hl7.org/fhir/ValueSet/observation-interpretation|5.0.0)

                      Codes identifying interpretations of observations.

                      ТипCodeableConcept
                      Модификаторfalse
                      Требуется поддержкаfalse
                      Summaryfalse
                      Требования

                      For some results, particularly numeric results, an interpretation is necessary to fully understand the significance of a result.

                      Альтернативные именаAbnormal Flag
                      Инвариантыele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
                      172. Observation.component:lifeCrit.referenceRange
                      Определение

                      Guidance on how to interpret the value by comparison to a normal or recommended range.

                      КороткийProvides guide for interpretation of component result
                      Комментарии

                      Most observations only have one generic reference range. Systems MAY choose to restrict to only supplying the relevant reference range based on knowledge about the patient (e.g., specific to the patient's age, gender, weight and other factors), but this might not be possible or appropriate. Whenever more than one reference range is supplied, the differences between them SHOULD be provided in the reference range and/or age properties.

                      Контроль0..*
                      ТипСмотретьttp://hl7.org/fhir/StructureDefinition/Observation#Observation.referenceRange
                      Модификаторfalse
                      Требуется поддержкаfalse
                      Summaryfalse
                      Требования

                      Knowing what values are considered "normal" can help evaluate the significance of a particular result. Need to be able to provide multiple reference ranges for different contexts.

                      Инвариантыele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))