0. Observation
Определение

Measurements and simple assertions made about a patient, device or other subject.

КороткийMeasurements and simple assertions
Комментарии

Used for simple observations such as device measurements, laboratory atomic results, vital signs, height, weight, smoking status, comments, etc. Other resources are used to provide context for observations such as laboratory reports, etc.

Контроль0..*
Модификаторfalse
Требуется поддержкаfalse
Summaryfalse
Альтернативные именаVital Signs, Measurement, Results, Tests
Инвариантыdom-2: If the resource is contained in another resource, it SHALL NOT contain nested Resources (contained.contained.empty())
dom-3: If the resource is contained in another resource, it SHALL be referred to from elsewhere in the resource or SHALL refer to the containing resource (contained.where((('#'+id in (%resource.descendants().reference | %resource.descendants().ofType(canonical) | %resource.descendants().ofType(uri) | %resource.descendants().ofType(url))) or descendants().where(reference = '#').exists() or descendants().where(ofType(canonical) = '#').exists() or descendants().where(ofType(canonical) = '#').exists()).not()).trace('unmatched', id).empty())
dom-4: If a resource is contained in another resource, it SHALL NOT have a meta.versionId or a meta.lastUpdated (contained.meta.versionId.empty() and contained.meta.lastUpdated.empty())
dom-5: If a resource is contained in another resource, it SHALL NOT have a security label (contained.meta.security.empty())
dom-6: A resource should have narrative for robust management (text.`div`.exists())
obs-6: dataAbsentReason SHALL only be present if Observation.value[x] is not present (dataAbsentReason.empty() or value.empty())
obs-7: If Observation.component.code is the same as Observation.code, then Observation.value SHALL NOT be present (the Observation.component.value[x] holds the value). (value.empty() or component.code.where(coding.intersect(%resource.code.coding).exists()).empty())
obs-8: bodyStructure SHALL only be present if Observation.bodySite is not present (bodySite.exists() implies bodyStructure.empty())
smeta-1: meta.source identifies the DMED or HPV screening system (meta.source.replaceMatches('#.*$', '') in ('https://dhp.uz/fhir/source/screening' | 'https://dhp.uz/fhir/source/dmed'))
dom-2: If the resource is contained in another resource, it SHALL NOT contain nested Resources (contained.contained.empty())
dom-3: If the resource is contained in another resource, it SHALL be referred to from elsewhere in the resource or SHALL refer to the containing resource (contained.where((('#'+id in (%resource.descendants().reference | %resource.descendants().ofType(canonical) | %resource.descendants().ofType(uri) | %resource.descendants().ofType(url))) or descendants().where(reference = '#').exists() or descendants().where(ofType(canonical) = '#').exists() or descendants().where(ofType(canonical) = '#').exists()).not()).trace('unmatched', id).empty())
dom-4: If a resource is contained in another resource, it SHALL NOT have a meta.versionId or a meta.lastUpdated (contained.meta.versionId.empty() and contained.meta.lastUpdated.empty())
dom-5: If a resource is contained in another resource, it SHALL NOT have a security label (contained.meta.security.empty())
dom-6: A resource should have narrative for robust management (text.`div`.exists())
obs-6: dataAbsentReason SHALL only be present if Observation.value[x] is not present (dataAbsentReason.empty() or value.empty())
obs-7: If Observation.component.code is the same as Observation.code, then Observation.value SHALL NOT be present (the Observation.component.value[x] holds the value). (value.empty() or component.code.where(coding.intersect(%resource.code.coding).exists()).empty())
obs-8: bodyStructure SHALL only be present if Observation.bodySite is not present (bodySite.exists() implies bodyStructure.empty())
2. Observation.meta
Определение

The metadata about the resource. This is content that is maintained by the infrastructure. Changes to the content might not always be associated with version changes to the resource.

КороткийMetadata about the resource
Контроль10..1
ТипMeta
Модификаторfalse
Требуется поддержкаtrue
Summarytrue
Инвариантыele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
ele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
4. Observation.meta.source
Определение

A uri that identifies the source system of the resource. This provides a minimal amount of Provenance information that can be used to track or differentiate the source of information in the resource. The source may identify another FHIR server, document, message, database, etc.


A uri that identifies the source system of the resource. This provides a minimal amount of Provenance information that can be used to track or differentiate the source of information in the resource. The source may identify another FHIR server, document, message, database, etc.

Короткийhttps://dhp.uz/fhir/source/screening | https://dhp.uz/fhir/source/dmedIdentifies where the resource comes from
Комментарии

Identifies which system created this resource: the HPV (ВПЧ) screening system or DMED. Do not infer source system from the presence of an identifier from screening-identifier-system -- that system's usage does not indicate which system produced a resource; DMED currently not writing to it is an implementation detail, not a guarantee.


The exact use of the source (and the possible implied Provenance.entity.role and agent.role) is left to implementer discretion. Only one nominated source is allowed; for additional provenance details, a full Provenance resource should be used. The source may correspond to Provenance.entity.what[x] or Provenance.agent.who[x], though it may be a more general or abstract reference.

This element can be used to indicate where the current master source of a resource that has a canonical URL if the resource is no longer hosted at the canonical URL.

Контроль10..1
Типuri
Модификаторfalse
Примитивное значениеЭтот примитивный элемент может присутствовать или отсутствовать, или быть замененным расширением
Требуется поддержкаtrue
Summarytrue
Инвариантыele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
ele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
6. Observation.implicitRules
Определение

A reference to a set of rules that were followed when the resource was constructed, and which must be understood when processing the content. Often, this is a reference to an implementation guide that defines the special rules along with other profiles etc.

КороткийA set of rules under which this content was created
Комментарии

Asserting this rule set restricts the content to be only understood by a limited set of trading partners. This inherently limits the usefulness of the data in the long term. However, the existing health eco-system is highly fractured, and not yet ready to define, collect, and exchange data in a generally computable sense. Wherever possible, implementers and/or specification writers should avoid using this element. Often, when used, the URL is a reference to an implementation guide that defines these special rules as part of its narrative along with other profiles, value sets, etc.

Контроль0..1
Типuri
Модификаторtrue потому что This element is labeled as a modifier because the implicit rules may provide additional knowledge about the resource that modifies its meaning or interpretation
Примитивное значениеЭтот примитивный элемент может присутствовать или отсутствовать, или быть замененным расширением
Требуется поддержкаfalse
Summarytrue
Инвариантыele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
ele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
8. Observation.contained
Определение

These resources do not have an independent existence apart from the resource that contains them - they cannot be identified independently, nor can they have their own independent transaction scope. This is allowed to be a Parameters resource if and only if it is referenced by a resource that provides context/meaning.

КороткийContained, inline Resources
Комментарии

This should never be done when the content can be identified properly, as once identification is lost, it is extremely difficult (and context dependent) to restore it again. Contained resources may have profiles and tags in their meta elements, but SHALL NOT have security labels.

Контроль0..*
На этот элемент влияют следующие инварианты: dom-2, dom-4, dom-3, dom-5
ТипResource
Модификаторfalse
Требуется поддержкаfalse
Summaryfalse
Альтернативные именаinline resources, anonymous resources, contained resources
10. Observation.modifierExtension
Определение

May be used to represent additional information that is not part of the basic definition of the resource and that modifies the understanding of the element that contains it and/or the understanding of the containing element's descendants. Usually modifier elements provide negation or qualification. To make the use of extensions safe and managable, there is a strict set of governance applied to the definition and use of extensions. Though any implementer is allowed to define an extension, there is a set of requirements that SHALL be met as part of the definition of the extension. Applications processing a resource are required to check for modifier extensions.

Modifier extensions SHALL NOT change the meaning of any elements on Resource or DomainResource (including cannot change the meaning of modifierExtension itself).

КороткийExtensions that cannot be ignored
Комментарии

There can be no stigma associated with the use of extensions by any application, project, or standard - regardless of the institution or jurisdiction that uses or defines the extensions. The use of extensions is what allows the FHIR specification to retain a core level of simplicity for everyone.

Контроль0..*
ТипExtension
Модификаторtrue потому что Modifier extensions are expected to modify the meaning or interpretation of the resource that contains them
Требуется поддержкаfalse
Summarytrue
Требования

Modifier extensions allow for extensions that cannot be safely ignored to be clearly distinguished from the vast majority of extensions which can be safely ignored. This promotes interoperability by eliminating the need for implementers to prohibit the presence of extensions. For further information, see the definition of modifier extensions.

Альтернативные именаextensions, user content
Инвариантыele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
ext-1: Must have either extensions or value[x], not both (extension.exists() != value.exists())
ele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
ext-1: Must have either extensions or value[x], not both (extension.exists() != value.exists())
12. Observation.identifier
Определение

A unique identifier assigned to this observation.

КороткийBusiness Identifier for observation
ПримечаниеЭто бизнес-идентификатор, а не идентификатор ресурса (см. обсуждение)
Контроль0..*
ТипIdentifier
Модификаторfalse
Требуется поддержкаtrue
Summarytrue
Требования

Allows observations to be distinguished and referenced.

Инвариантыele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
ele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
14. Observation.instantiates[x]
Определение

The reference to a FHIR ObservationDefinition resource that provides the definition that is adhered to in whole or in part by this Observation instance.

КороткийInstantiates FHIR ObservationDefinition
Комментарии

ObservationDefinition can be referenced by its canonical url using instantiatesCanonical, or by a name or an identifier using the appropriate sub-elements of instantiatesReference.

Контроль0..1
ТипВыбор: canonical(ObservationDefinition), Reference(ObservationDefinition)
[x] ЗаметкаСмотретьВыбор типов данныхдля дополнительной информации о том, как использовать [x]
Модификаторfalse
Примитивное значениеЭтот примитивный элемент может присутствовать или отсутствовать, или быть замененным расширением
Требуется поддержкаtrue
Необходимо поддерживать типыНет обязательных правил поддержки выбора типов/профилей
Summarytrue
Инвариантыele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
ele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
16. Observation.basedOn
Определение

A plan, proposal or order that is fulfilled in whole or in part by this event. For example, a MedicationRequest may require a patient to have laboratory test performed before it is dispensed.

КороткийFulfills plan, proposal or order
Контроль0..*
ТипReference(CarePlan, MedicationRequest, ServiceRequest, UZ Core ImmunizationRecommendation, DeviceRequest, ImmunizationRecommendation, NutritionOrder)
Модификаторfalse
Требуется поддержкаtrue
Необходимо поддерживать типыНет обязательных правил поддержки выбора типов/профилей
Summarytrue
Требования

Allows tracing of authorization for the event and tracking whether proposals/recommendations were acted upon.

Альтернативные именаFulfills
Инвариантыele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
ele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
18. Observation.triggeredBy
Определение

Identifies the observation(s) that triggered the performance of this observation.

КороткийTriggering observation(s)
Контроль0..*
ТипBackboneElement
Модификаторfalse
Требуется поддержкаtrue
Summaryfalse
Инвариантыele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
ele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
20. Observation.triggeredBy.modifierExtension
Определение

May be used to represent additional information that is not part of the basic definition of the element and that modifies the understanding of the element in which it is contained and/or the understanding of the containing element's descendants. Usually modifier elements provide negation or qualification. To make the use of extensions safe and managable, there is a strict set of governance applied to the definition and use of extensions. Though any implementer can define an extension, there is a set of requirements that SHALL be met as part of the definition of the extension. Applications processing a resource are required to check for modifier extensions.

Modifier extensions SHALL NOT change the meaning of any elements on Resource or DomainResource (including cannot change the meaning of modifierExtension itself).

КороткийExtensions that cannot be ignored even if unrecognized
Комментарии

There can be no stigma associated with the use of extensions by any application, project, or standard - regardless of the institution or jurisdiction that uses or defines the extensions. The use of extensions is what allows the FHIR specification to retain a core level of simplicity for everyone.

Контроль0..*
ТипExtension
Модификаторtrue потому что Modifier extensions are expected to modify the meaning or interpretation of the element that contains them
Summarytrue
Требования

Modifier extensions allow for extensions that cannot be safely ignored to be clearly distinguished from the vast majority of extensions which can be safely ignored. This promotes interoperability by eliminating the need for implementers to prohibit the presence of extensions. For further information, see the definition of modifier extensions.

Альтернативные именаextensions, user content, modifiers
Инвариантыele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
ext-1: Must have either extensions or value[x], not both (extension.exists() != value.exists())
ele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
ext-1: Must have either extensions or value[x], not both (extension.exists() != value.exists())
22. Observation.triggeredBy.observation
Определение

Reference to the triggering observation.

КороткийTriggering observation
Контроль1..1
ТипReference(UZ Core Observation, Observation)
Модификаторfalse
Требуется поддержкаfalse
Summarytrue
Инвариантыele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
ele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
24. Observation.triggeredBy.type
Определение

The type of trigger. Reflex | Repeat | Re-run.

Короткийreflex | repeat | re-run
Контроль1..1
ПривязкаКоды ДОЛЖНЫ быть взяты из TriggeredByTypeVS (0.12.0)http://hl7.org/fhir/ValueSet/observation-triggeredbytype|5.0.0
(required to https://terminology.dhp.uz/fhir/core/ValueSet/triggered-bytype-vs|0.12.0)
Типcode
Модификаторfalse
Примитивное значениеЭтот примитивный элемент может присутствовать или отсутствовать, или быть замененным расширением
Требуется поддержкаfalse
Summarytrue
Инвариантыele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
ele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
26. Observation.triggeredBy.reason
Определение

Provides the reason why this observation was performed as a result of the observation(s) referenced.

КороткийReason that the observation was triggered
Контроль0..1
Типstring
Модификаторfalse
Примитивное значениеЭтот примитивный элемент может присутствовать или отсутствовать, или быть замененным расширением
Требуется поддержкаtrue
Summaryfalse
Инвариантыele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
ele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
28. Observation.partOf
Определение

A larger event of which this particular Observation is a component or step. For example, an observation as part of a procedure.

КороткийPart of referenced event
Комментарии

To link an Observation to an Encounter use encounter. See the Notes below for guidance on referencing another Observation.

Контроль0..*
ТипReference(MedicationAdministration, MedicationDispense, UZ Core Procedure, UZ Core Immunization, ImagingStudy, MedicationStatement, Procedure, Immunization, GenomicStudy)
Модификаторfalse
Требуется поддержкаtrue
Необходимо поддерживать типыНет обязательных правил поддержки выбора типов/профилей
Summarytrue
Альтернативные именаContainer
Инвариантыele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
ele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
30. Observation.status
Определение

The status of the result value.

Короткийregistered | preliminary | final | amended +
Комментарии

This element is labeled as a modifier because the status contains codes that mark the resource as not currently valid.

Контроль1..1
ПривязкаКоды ДОЛЖНЫ быть взяты из ObservationStatusVS (0.12.0)http://hl7.org/fhir/ValueSet/observation-status|5.0.0
(required to https://terminology.dhp.uz/fhir/core/ValueSet/observation-status-vs|0.12.0)
Типcode
Модификаторtrue потому что This element is labeled as a modifier because it is a status element that contains status entered-in-error which means that the resource should not be treated as valid
Примитивное значениеЭтот примитивный элемент может присутствовать или отсутствовать, или быть замененным расширением
Требуется поддержкаtrue
Summarytrue
Требования

Need to track the status of individual results. Some results are finalized before the whole report is finalized.

Инвариантыele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
ele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
32. Observation.category
Определение

A code that classifies the general type of observation being made.

КороткийClassification of type of observation
Комментарии

In addition to the required category valueset, this element allows various categorization schemes based on the owner’s definition of the category and effectively multiple categories can be used at once. The level of granularity is defined by the category concepts in the value set.

Контроль0..*
ПривязкаКоды СЛЕДУЕТ взять из ObservationCategoryVS (0.12.0)http://hl7.org/fhir/ValueSet/observation-category|5.0.0
(preferred to https://terminology.dhp.uz/fhir/core/ValueSet/observation-category-vs|0.12.0)
ТипCodeableConcept
Модификаторfalse
Требуется поддержкаtrue
Summaryfalse
Требования

Used for filtering what observations are retrieved and displayed.

Инвариантыele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
ele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
SlicingЭтот элемент представляет набор разрезов на Observation.category. Разрезы бываютНе упорядочено и Open, и могут быть дифференцированы с помощью следующих дискриминаторов:
  • value @ $this
  • 34. Observation.category:dhpCategory
    Название разрезаdhpCategory
    Определение

    A code that classifies the general type of observation being made.

    КороткийCategory from the national value setClassification of type of observation
    Комментарии

    In addition to the required category valueset, this element allows various categorization schemes based on the owner’s definition of the category and effectively multiple categories can be used at once. The level of granularity is defined by the category concepts in the value set.

    Контроль0..*
    ПривязкаКоды ДОЛЖНЫ быть взяты из Коды СЛЕДУЕТ взять из ObservationCategoryVS (0.12.0)http://hl7.org/fhir/ValueSet/observation-category|5.0.0
    (required to https://terminology.dhp.uz/fhir/core/ValueSet/observation-category-vs|0.12.0)
    ТипCodeableConcept
    Модификаторfalse
    Требуется поддержкаtrue
    Summaryfalse
    Требования

    Used for filtering what observations are retrieved and displayed.

    Инвариантыele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
    ele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
    36. Observation.code
    Определение

    Describes what was observed. Sometimes this is called the observation "name".

    КороткийType of observation (code / type)
    Комментарии

    All code-value and, if present, component.code-component.value pairs need to be taken into account to correctly understand the meaning of the observation.

    Контроль1..1
    На этот элемент влияют следующие инварианты: obs-7
    ПривязкаКоды СЛЕДУЕТ взять из Например, коды см. ScreeningObservationCodesVS (0.12.1)http://hl7.org/fhir/ValueSet/observation-codes|5.0.0
    (preferred to https://terminology.dhp.uz/fhir/integrations/ValueSet/screening-observation-codes-vs|0.12.1)
    ТипCodeableConcept
    Модификаторfalse
    Требуется поддержкаtrue
    Summarytrue
    Требования

    Knowing what kind of observation is being made is essential to understanding the observation.

    Альтернативные именаName
    Значение шаблона{
      "coding" : [{
        "system" : "http://snomed.info/sct",
        "code" : "47079000",
        "display" : "Ultrasonography of breast"
      }]
    }
    Инвариантыele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
    ele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
    38. Observation.subject
    Определение

    The patient, or group of patients, location, device, organization, procedure or practitioner this observation is about and into whose or what record the observation is placed. If the actual focus of the observation is different from the subject (or a sample of, part, or region of the subject), the focus element or the code itself specifies the actual focus of the observation.

    КороткийWho and/or what the observation is about
    Комментарии

    One would expect this element to be a cardinality of 1..1. The only circumstance in which the subject can be missing is when the observation is made by a device that does not know the patient. In this case, the observation SHALL be matched to a patient through some context/channel matching technique, and at this point, the observation should be updated. The subject of an Observation may in some cases be a procedure. This supports the regulatory inspection use case where observations are captured during inspections of a procedure that is being performed (independent of any particular patient or whether patient related at all).

    Контроль0..1
    ТипReference(UZ Core Patient, UZ Core Location, UZ Core Organization, UZ Core Procedure, UZ Core Practitioner, UZ Core Medication, Patient, Group, Device, Location, Organization, Procedure, Practitioner, Medication, Substance, BiologicallyDerivedProduct, NutritionProduct)
    Модификаторfalse
    Требуется поддержкаtrue
    Необходимо поддерживать типыНет обязательных правил поддержки выбора типов/профилей
    Summarytrue
    Требования

    Observations have no value if you don't know who or what they're about.

    Инвариантыele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
    ele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
    40. Observation.focus
    Определение

    The actual focus of an observation when it is not the patient of record representing something or someone associated with the patient such as a spouse, parent, fetus, or donor. For example, fetus observations in a mother's record. The focus of an observation could also be an existing condition, an intervention, the subject's diet, another observation of the subject, or a body structure such as tumor or implanted device. An example use case would be using the Observation resource to capture whether the mother is trained to change her child's tracheostomy tube. In this example, the child is the patient of record and the mother is the focus.

    КороткийWhat the observation is about, when it is not about the subject of record
    Комментарии

    Typically, an observation is made about the subject - a patient, or group of patients, location, or device - and the distinction between the subject and what is directly measured for an observation is specified in the observation code itself ( e.g., "Blood Glucose") and does not need to be represented separately using this element. Use specimen if a reference to a specimen is required. If a code is required instead of a resource use either bodysite for bodysites or the standard extension http://hl7.org/fhir/StructureDefinition/observation-focusCode.

    Контроль0..*
    ТипReference(Resource)
    Модификаторfalse
    Требуется поддержкаtrue
    Summarytrue
    Инвариантыele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
    ele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
    42. Observation.encounter
    Определение

    The healthcare event (e.g. a patient and healthcare provider interaction) during which this observation is made.

    КороткийHealthcare event during which this observation is made
    Комментарии

    This will typically be the encounter the event occurred within, but some events may be initiated prior to or after the official completion of an encounter but still be tied to the context of the encounter (e.g. pre-admission laboratory tests).

    Контроль0..1
    ТипReference(UZ Core Encounter, Encounter)
    Модификаторfalse
    Требуется поддержкаtrue
    Summarytrue
    Требования

    For some observations it may be important to know the link between an observation and a particular encounter.

    Альтернативные именаContext
    Инвариантыele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
    ele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
    44. Observation.effective[x]
    Определение

    The time or time-period the observed value is asserted as being true. For biological subjects - e.g. human patients - this is usually called the "physiologically relevant time". This is usually either the time of the procedure or of specimen collection, but very often the source of the date/time is not known, only the date/time itself.

    КороткийClinically relevant time/time-period for observation
    Комментарии

    At least a date should be present unless this observation is a historical report. For recording imprecise or "fuzzy" times (For example, a blood glucose measurement taken "after breakfast") use the Timing datatype which allow the measurement to be tied to regular life events.

    Контроль0..1
    ТипВыбор: dateTime, Period, Timing, instant
    [x] ЗаметкаСмотретьВыбор типов данныхдля дополнительной информации о том, как использовать [x]
    Модификаторfalse
    Примитивное значениеЭтот примитивный элемент может присутствовать или отсутствовать, или быть замененным расширением
    Требуется поддержкаtrue
    Необходимо поддерживать типыНет обязательных правил поддержки выбора типов/профилей
    Summarytrue
    Требования

    Knowing when an observation was deemed true is important to its relevance as well as determining trends.

    Альтернативные именаOccurrence
    Инвариантыele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
    ele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
    46. Observation.issued
    Определение

    The date and time this version of the observation was made available to providers, typically after the results have been reviewed and verified.

    КороткийDate/Time this version was made available
    Комментарии

    For Observations that don't require review and verification, it may be the same as the lastUpdated time of the resource itself. For Observations that do require review and verification for certain updates, it might not be the same as the lastUpdated time of the resource itself due to a non-clinically significant update that doesn't require the new version to be reviewed and verified again.

    Контроль0..1
    Типinstant
    Модификаторfalse
    Примитивное значениеЭтот примитивный элемент может присутствовать или отсутствовать, или быть замененным расширением
    Требуется поддержкаtrue
    Summarytrue
    Инвариантыele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
    ele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
    48. Observation.performer
    Определение

    Who was responsible for asserting the observed value as "true".

    КороткийWho is responsible for the observation
    Контроль0..*
    ТипReference(UZ Core Practitioner, UZ Core PractitionerRole, UZ Core Organization, Practitioner, PractitionerRole, Organization, CareTeam, Patient, RelatedPerson)
    Модификаторfalse
    Требуется поддержкаtrue
    Необходимо поддерживать типыНет обязательных правил поддержки выбора типов/профилей
    Summarytrue
    Требования

    May give a degree of confidence in the observation and also indicates where follow-up questions should be directed.

    Инвариантыele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
    ele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
    50. Observation.value[x]
    Определение

    The information determined as a result of making the observation, if the information has a simple value.

    КороткийActual result
    Комментарии
    • An observation may have:
      1. a single value here
      2. both a value and a set of related or component values
      3. only a set of related or component values.
    • If a value is present, the datatype for this element should be determined by the code.
    • CodeableConcept with just a text would be used instead of a string if the field was usually coded, or if the type associated with the code defines a coded value.
    • Attachment is used if the observation result value is a binary file such as an image. If the observation result value is derived from the binary file (for example 'X' detected and here is the the proof in this image), the binary file may be directly represented using DocumentReference and referenced by derivedFrom.
    • The usage of valueReference is restricted to the MolecularSequence resource when used as a definitional resource, not as a patient-specific finding. .
    • For additional guidance, see the Notes section below.
    Контроль0..1
    На этот элемент влияют следующие инварианты: obs-7, obs-6
    ТипCodeableConcept, dateTime, string, Reference(MolecularSequence), Quantity, Period, Attachment, integer, Range, boolean, SampledData, Ratio, time
    [x] ЗаметкаСмотретьВыбор типов данныхдля дополнительной информации о том, как использовать [x]
    Модификаторfalse
    Требуется поддержкаtrue
    Summarytrue
    Требования

    An observation exists to have a value, though it might not if it is in error, or if it represents a group of observations.

    Инвариантыele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
    ele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
    SlicingЭтот элемент представляет набор разрезов на Observation.value[x]. Разрезы бываютНе упорядочено и Closed, и могут быть дифференцированы с помощью следующих дискриминаторов:
    • type @ $this
    • 52. Observation.value[x]:valueCodeableConcept
      Название разрезаvalueCodeableConcept
      Определение

      The information determined as a result of making the observation, if the information has a simple value.

      КороткийActual result
      Комментарии
      • An observation may have:
        1. a single value here
        2. both a value and a set of related or component values
        3. only a set of related or component values.
      • If a value is present, the datatype for this element should be determined by the code.
      • CodeableConcept with just a text would be used instead of a string if the field was usually coded, or if the type associated with the code defines a coded value.
      • Attachment is used if the observation result value is a binary file such as an image. If the observation result value is derived from the binary file (for example 'X' detected and here is the the proof in this image), the binary file may be directly represented using DocumentReference and referenced by derivedFrom.
      • The usage of valueReference is restricted to the MolecularSequence resource when used as a definitional resource, not as a patient-specific finding. .
      • For additional guidance, see the Notes section below.
      Контроль0..1
      На этот элемент влияют следующие инварианты: obs-7, obs-6
      ПривязкаКоды СЛЕДУЕТ взять из Информацию о кодах см. ScreeningObservationValuesVS (0.12.1)
      (preferred to https://terminology.dhp.uz/fhir/integrations/ValueSet/screening-observation-values-vs|0.12.1)
      ТипCodeableConcept, dateTime, string, Reference(MolecularSequence), Quantity, Period, Attachment, integer, Range, boolean, SampledData, Ratio, time
      [x] ЗаметкаСмотретьВыбор типов данныхдля дополнительной информации о том, как использовать [x]
      Модификаторfalse
      Требуется поддержкаtrue
      Summarytrue
      Требования

      An observation exists to have a value, though it might not if it is in error, or if it represents a group of observations.

      Инвариантыele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
      ele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
      54. Observation.dataAbsentReason
      Определение

      Provides a reason why the expected value in the element Observation.value[x] is missing.

      КороткийWhy the result is missing
      Комментарии

      Null or exceptional values can be represented two ways in FHIR Observations. One way is to simply include them in the value set and represent the exceptions in the value. For example, measurement values for a serology test could be "detected", "not detected", "inconclusive", or "specimen unsatisfactory".

      The alternate way is to use the value element for actual observations and use the explicit dataAbsentReason element to record exceptional values. For example, the dataAbsentReason code "error" could be used when the measurement was not completed. Note that an observation may only be reported if there are values to report. For example differential cell counts values may be reported only when > 0. Because of these options, use-case agreements are required to interpret general observations for null or exceptional values.

      Контроль0..1
      На этот элемент влияют следующие инварианты: obs-6
      ПривязкаЕсли они не подходят, эти коды ДОЛЖНЫ быть взяты из DataAbsentReasonVS (0.12.0)http://hl7.org/fhir/ValueSet/data-absent-reason|5.0.0
      (extensible to https://terminology.dhp.uz/fhir/core/ValueSet/data-absent-reason-vs|0.12.0)
      ТипCodeableConcept
      Модификаторfalse
      Требуется поддержкаtrue
      Summaryfalse
      Требования

      For many results it is necessary to handle exceptional values in measurements.

      Инвариантыele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
      ele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
      56. Observation.note
      Определение

      Comments about the observation or the results.

      КороткийComments about the observation
      Комментарии

      May include general statements about the observation, or statements about significant, unexpected or unreliable results values, or information about its source when relevant to its interpretation.

      Контроль0..*
      ТипAnnotation
      Модификаторfalse
      Требуется поддержкаtrue
      Summaryfalse
      Требования

      Need to be able to provide free text additional information.

      Инвариантыele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
      ele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
      58. Observation.bodySite
      Определение

      Indicates the site on the subject's body where the observation was made (i.e. the target site).

      КороткийExamined breast sideObserved body part
      Комментарии

      Only used if not implicit in code found in Observation.code. In many systems, this may be represented as a related observation instead of an inline component.

      Контроль10..1
      На этот элемент влияют следующие инварианты: obs-8
      ПривязкаКоды ДОЛЖНЫ быть взяты из Например, коды см. ScreeningUltrasoundBreastSideVS (0.12.1)http://hl7.org/fhir/ValueSet/body-site|5.0.0
      (required to https://terminology.dhp.uz/fhir/integrations/ValueSet/screening-ultrasound-breast-side-vs|0.12.1)
      ТипCodeableConcept
      Модификаторfalse
      Требуется поддержкаtrue
      Summaryfalse
      Инвариантыele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
      ele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
      60. Observation.bodySite.extension:quadrant
      Название разрезаquadrant
      Определение

      Breast quadrant used to localize findings.

      КороткийBreast Quadrant Extension
      Контроль0..*
      ТипExtension(Breast Quadrant Extension) (Тип расширения: CodeableConcept)
      Модификаторfalse
      Требуется поддержкаtrue
      Summaryfalse
      Инвариантыele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
      ext-1: Must have either extensions or value[x], not both (extension.exists() != value.exists())
      ele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
      ext-1: Must have either extensions or value[x], not both (extension.exists() != value.exists())
      62. Observation.specimen
      Определение

      The specimen that was used when this observation was made.

      КороткийSpecimen used for this observation
      Комментарии

      Should only be used if not implicit in code found in Observation.code. Observations are not made on specimens themselves; they are made on a subject, but in many cases by the means of a specimen. Note that although specimens are often involved, they are not always tracked and reported explicitly. Also note that observation resources may be used in contexts that track the specimen explicitly (e.g. Diagnostic Report).

      Контроль0..1
      ТипReference(UZ Core Specimen, Specimen, Group)
      Модификаторfalse
      Требуется поддержкаtrue
      Summaryfalse
      Инвариантыele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
      obs-9: If Observation.specimen is a reference to Group, the group can only have specimens ((reference.resolve().exists() and reference.resolve() is Group) implies reference.resolve().member.entity.resolve().all($this is Specimen))
      ele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
      obs-9: If Observation.specimen is a reference to Group, the group can only have specimens ((reference.resolve().exists() and reference.resolve() is Group) implies reference.resolve().member.entity.resolve().all($this is Specimen))
      64. Observation.device
      Определение

      A reference to the device that generates the measurements or the device settings for the device.

      КороткийA reference to the device that generates the measurements or the device settings for the device
      Комментарии

      Note that this is not meant to represent a device involved in the transmission of the result, e.g., a gateway. Such devices may be documented using the Provenance resource where relevant.

      Контроль0..1
      ТипReference(Device, DeviceMetric)
      Модификаторfalse
      Требуется поддержкаtrue
      Необходимо поддерживать типыНет обязательных правил поддержки выбора типов/профилей
      Summaryfalse
      Инвариантыele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
      ele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
      66. Observation.referenceRange
      Определение

      Guidance on how to interpret the value by comparison to a normal or recommended range. Multiple reference ranges are interpreted as an "OR". In other words, to represent two distinct target populations, two referenceRange elements would be used.

      КороткийProvides guide for interpretation
      Комментарии

      Most observations only have one generic reference range. Systems MAY choose to restrict to only supplying the relevant reference range based on knowledge about the patient (e.g., specific to the patient's age, gender, weight and other factors), but this might not be possible or appropriate. Whenever more than one reference range is supplied, the differences between them SHOULD be provided in the reference range and/or age properties.

      Контроль0..*
      ТипBackboneElement
      Модификаторfalse
      Требуется поддержкаtrue
      Summaryfalse
      Требования

      Knowing what values are considered "normal" can help evaluate the significance of a particular result. Need to be able to provide multiple reference ranges for different contexts.

      Инвариантыele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
      obs-3: Must have at least a low or a high or text (low.exists() or high.exists() or text.exists())
      ele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
      obs-3: Must have at least a low or a high or text (low.exists() or high.exists() or text.exists())
      68. Observation.referenceRange.modifierExtension
      Определение

      May be used to represent additional information that is not part of the basic definition of the element and that modifies the understanding of the element in which it is contained and/or the understanding of the containing element's descendants. Usually modifier elements provide negation or qualification. To make the use of extensions safe and managable, there is a strict set of governance applied to the definition and use of extensions. Though any implementer can define an extension, there is a set of requirements that SHALL be met as part of the definition of the extension. Applications processing a resource are required to check for modifier extensions.

      Modifier extensions SHALL NOT change the meaning of any elements on Resource or DomainResource (including cannot change the meaning of modifierExtension itself).

      КороткийExtensions that cannot be ignored even if unrecognized
      Комментарии

      There can be no stigma associated with the use of extensions by any application, project, or standard - regardless of the institution or jurisdiction that uses or defines the extensions. The use of extensions is what allows the FHIR specification to retain a core level of simplicity for everyone.

      Контроль0..*
      ТипExtension
      Модификаторtrue потому что Modifier extensions are expected to modify the meaning or interpretation of the element that contains them
      Summarytrue
      Требования

      Modifier extensions allow for extensions that cannot be safely ignored to be clearly distinguished from the vast majority of extensions which can be safely ignored. This promotes interoperability by eliminating the need for implementers to prohibit the presence of extensions. For further information, see the definition of modifier extensions.

      Альтернативные именаextensions, user content, modifiers
      Инвариантыele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
      ext-1: Must have either extensions or value[x], not both (extension.exists() != value.exists())
      ele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
      ext-1: Must have either extensions or value[x], not both (extension.exists() != value.exists())
      70. Observation.referenceRange.low
      Определение

      The value of the low bound of the reference range. The low bound of the reference range endpoint is inclusive of the value (e.g. reference range is >=5 - <=9). If the low bound is omitted, it is assumed to be meaningless (e.g. reference range is <=2.3).

      КороткийLow Range, if relevant
      Контроль0..1
      На этот элемент влияют следующие инварианты: obs-3
      ТипQuantity(SimpleQuantity)
      Модификаторfalse
      Требуется поддержкаtrue
      Summaryfalse
      Инвариантыele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
      ele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
      72. Observation.referenceRange.high
      Определение

      The value of the high bound of the reference range. The high bound of the reference range endpoint is inclusive of the value (e.g. reference range is >=5 - <=9). If the high bound is omitted, it is assumed to be meaningless (e.g. reference range is >= 2.3).

      КороткийHigh Range, if relevant
      Контроль0..1
      На этот элемент влияют следующие инварианты: obs-3
      ТипQuantity(SimpleQuantity)
      Модификаторfalse
      Требуется поддержкаtrue
      Summaryfalse
      Инвариантыele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
      ele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
      74. Observation.referenceRange.normalValue
      Определение

      The value of the normal value of the reference range.

      КороткийNormal value, if relevant
      Контроль0..1
      ПривязкаЕсли они не подходят, эти коды ДОЛЖНЫ быть взяты из ObservationNormalValueVS (0.12.0)http://hl7.org/fhir/ValueSet/observation-referencerange-normalvalue|5.0.0
      (extensible to https://terminology.dhp.uz/fhir/core/ValueSet/observation-normal-value-vs|0.12.0)
      ТипCodeableConcept
      Модификаторfalse
      Требуется поддержкаtrue
      Summaryfalse
      Инвариантыele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
      ele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
      76. Observation.referenceRange.age
      Определение

      The age at which this reference range is applicable. This is a neonatal age (e.g. number of weeks at term) if the meaning says so.

      КороткийApplicable age range, if relevant
      Контроль0..1
      ТипRange
      Модификаторfalse
      Требуется поддержкаtrue
      Summaryfalse
      Требования

      Some analytes vary greatly over age.

      Инвариантыele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
      ele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
      78. Observation.referenceRange.text
      Определение

      Text based reference range in an observation which may be used when a quantitative range is not appropriate for an observation. An example would be a reference value of "Negative" or a list or table of "normals".

      КороткийText based reference range in an observation
      Контроль0..1
      На этот элемент влияют следующие инварианты: obs-3
      Типmarkdown
      Модификаторfalse
      Примитивное значениеЭтот примитивный элемент может присутствовать или отсутствовать, или быть замененным расширением
      Требуется поддержкаtrue
      Summaryfalse
      Инвариантыele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
      ele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
      80. Observation.hasMember
      Определение

      This observation is a group observation (e.g. a battery, a panel of tests, a set of vital sign measurements) that includes the target as a member of the group.

      КороткийRelated resource that belongs to the Observation group
      Комментарии

      When using this element, an observation will typically have either a value or a set of related resources, although both may be present in some cases. For a discussion on the ways Observations can assembled in groups together, see Notes below. Note that a system may calculate results from QuestionnaireResponse into a final score and represent the score as an Observation.


      When using this element, an observation will typically have either a value or a set of related resources, although both may be present in some cases. For a discussion on the ways Observations can assembled in groups together, see Notes below. Note that a system may calculate results from QuestionnaireResponse into a final score and represent the score as an Observation.

      Контроль0..*
      ТипReference(UZ Core Observation, UZ Core QuestionnaireResponse, Observation, QuestionnaireResponse, MolecularSequence)
      Модификаторfalse
      Требуется поддержкаtrue
      Необходимо поддерживать типыНет обязательных правил поддержки выбора типов/профилей
      Summarytrue
      Инвариантыele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
      ele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
      82. Observation.derivedFrom
      Определение

      The target resource that represents a measurement from which this observation value is derived. For example, a calculated anion gap or a fetal measurement based on an ultrasound image.

      КороткийRelated resource from which the observation is made
      Комментарии

      All the reference choices that are listed in this element can represent clinical observations and other measurements that may be the source for a derived value. The most common reference will be another Observation. For a discussion on the ways Observations can assembled in groups together, see Notes below.

      Контроль0..*
      ТипReference(DocumentReference, ImagingStudy, UZ Core QuestionnaireResponse, UZ Core Observation, ImagingSelection, QuestionnaireResponse, Observation, MolecularSequence, GenomicStudy)
      Модификаторfalse
      Требуется поддержкаtrue
      Необходимо поддерживать типыНет обязательных правил поддержки выбора типов/профилей
      Summarytrue
      Инвариантыele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
      ele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
      84. Observation.component
      Определение

      Some observations have multiple component observations. These component observations are expressed as separate code value pairs that share the same attributes. Examples include systolic and diastolic component observations for blood pressure measurement and multiple component observations for genetics observations.

      КороткийComponent results
      Комментарии

      For a discussion on the ways Observations can be assembled in groups together see Notes below.

      Контроль0..*
      На этот элемент влияют следующие инварианты: obs-7
      ТипBackboneElement
      Модификаторfalse
      Требуется поддержкаtrue
      Summarytrue
      Требования

      Component observations share the same attributes in the Observation resource as the primary observation and are always treated a part of a single observation (they are not separable). However, the reference range for the primary observation value is not inherited by the component values and is required when appropriate for each component observation.

      Инвариантыele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
      ele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
      SlicingЭтот элемент представляет набор разрезов на Observation.component. Разрезы бываютНе упорядочено и Open, и могут быть дифференцированы с помощью следующих дискриминаторов:
      • value @ code
      • 86. Observation.component.modifierExtension
        Определение

        May be used to represent additional information that is not part of the basic definition of the element and that modifies the understanding of the element in which it is contained and/or the understanding of the containing element's descendants. Usually modifier elements provide negation or qualification. To make the use of extensions safe and managable, there is a strict set of governance applied to the definition and use of extensions. Though any implementer can define an extension, there is a set of requirements that SHALL be met as part of the definition of the extension. Applications processing a resource are required to check for modifier extensions.

        Modifier extensions SHALL NOT change the meaning of any elements on Resource or DomainResource (including cannot change the meaning of modifierExtension itself).

        КороткийExtensions that cannot be ignored even if unrecognized
        Комментарии

        There can be no stigma associated with the use of extensions by any application, project, or standard - regardless of the institution or jurisdiction that uses or defines the extensions. The use of extensions is what allows the FHIR specification to retain a core level of simplicity for everyone.

        Контроль0..*
        ТипExtension
        Модификаторtrue потому что Modifier extensions are expected to modify the meaning or interpretation of the element that contains them
        Summarytrue
        Требования

        Modifier extensions allow for extensions that cannot be safely ignored to be clearly distinguished from the vast majority of extensions which can be safely ignored. This promotes interoperability by eliminating the need for implementers to prohibit the presence of extensions. For further information, see the definition of modifier extensions.

        Альтернативные именаextensions, user content, modifiers
        Инвариантыele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
        ext-1: Must have either extensions or value[x], not both (extension.exists() != value.exists())
        ele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
        ext-1: Must have either extensions or value[x], not both (extension.exists() != value.exists())
        88. Observation.component.code
        Определение

        Describes what was observed. Sometimes this is called the observation "code".

        КороткийType of component observation (code / type)
        Комментарии

        All code-value and component.code-component.value pairs need to be taken into account to correctly understand the meaning of the observation.

        Контроль1..1
        На этот элемент влияют следующие инварианты: obs-7
        ПривязкаКоды СЛЕДУЕТ взять из Например, коды см. ObservationCodesVS (0.12.0)http://hl7.org/fhir/ValueSet/observation-codes|5.0.0
        (preferred to https://terminology.dhp.uz/fhir/core/ValueSet/observation-codes-vs|0.12.0)
        ТипCodeableConcept
        Модификаторfalse
        Требуется поддержкаtrue
        Summarytrue
        Требования

        Knowing what kind of observation is being made is essential to understanding the observation.

        Инвариантыele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
        ele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
        90. Observation.component.value[x]
        Определение

        The information determined as a result of making the observation, if the information has a simple value.

        КороткийActual component result
        Комментарии

        Used when observation has a set of component observations:

        • An observation may have both a value (e.g. an Apgar score) and component observations (the observations from which the Apgar score was derived).
        • If a value is present, the datatype for this element should be determined by the code.
        • CodeableConcept with just a text would be used instead of a string if the field was usually coded, or if the type associated with the code defines a coded value.
        • Attachment is used if the observation result value is a binary file such as an image. If the observation result value is derived from the binary file (for example 'X' detected and here is the the proof in this image), the binary file may be directly represented using DocumentReference and referenced by derivedFrom.
        • If a value is present, the datatype for this element should be determined by the code.
        • CodeableConcept with just a text would be used instead of a string if the field was usually coded, or if the type associated with the code defines a coded value.
        • Attachment is used if the observation result value is a binary file such as an image. If the observation result value is derived from the binary file (for example 'X' detected and here is the the proof in this image), the binary file may be directly represented using DocumentReference and referenced by derivedFrom.
        • The usage of valueReference is restricted to the MolecularSequence resource when used as a definitional resource, not as a patient-specific finding. .
        • For additional guidance, see the Notes section below.
        Контроль0..1
        ТипВыбор: Quantity, CodeableConcept, string, boolean, integer, Range, Ratio, SampledData, time, dateTime, Period, Attachment, Reference(MolecularSequence)
        [x] ЗаметкаСмотретьВыбор типов данныхдля дополнительной информации о том, как использовать [x]
        Модификаторfalse
        Примитивное значениеЭтот примитивный элемент может присутствовать или отсутствовать, или быть замененным расширением
        Требуется поддержкаtrue
        Необходимо поддерживать типыНет обязательных правил поддержки выбора типов/профилей
        Summarytrue
        Требования

        An observation exists to have a value, though it might not if it is in error, or if it represents a group of observations.

        Инвариантыele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
        ele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
        92. Observation.component:transformationZone
        Название разрезаtransformationZone
        Определение

        Some observations have multiple component observations. These component observations are expressed as separate code value pairs that share the same attributes. Examples include systolic and diastolic component observations for blood pressure measurement and multiple component observations for genetics observations.

        КороткийCervical transformation zone type (colposcopy)Component results
        Комментарии

        For a discussion on the ways Observations can be assembled in groups together see Notes below.

        Контроль0..0*
        На этот элемент влияют следующие инварианты: obs-7
        ТипBackboneElement
        Модификаторfalse
        Требуется поддержкаtrue
        Summarytrue
        Требования

        Component observations share the same attributes in the Observation resource as the primary observation and are always treated a part of a single observation (they are not separable). However, the reference range for the primary observation value is not inherited by the component values and is required when appropriate for each component observation.

        Инвариантыele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
        ele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
        97. Observation.component:birads
        Название разрезаbirads
        Определение

        Some observations have multiple component observations. These component observations are expressed as separate code value pairs that share the same attributes. Examples include systolic and diastolic component observations for blood pressure measurement and multiple component observations for genetics observations.

        КороткийBI-RADS assessment category (mammography)Component results
        Комментарии

        For a discussion on the ways Observations can be assembled in groups together see Notes below.

        Контроль0..1*
        На этот элемент влияют следующие инварианты: obs-7
        ТипBackboneElement
        Модификаторfalse
        Требуется поддержкаtrue
        Summarytrue
        Требования

        Component observations share the same attributes in the Observation resource as the primary observation and are always treated a part of a single observation (they are not separable). However, the reference range for the primary observation value is not inherited by the component values and is required when appropriate for each component observation.

        Инвариантыele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
        ele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
        99. Observation.component:birads.modifierExtension
        Определение

        May be used to represent additional information that is not part of the basic definition of the element and that modifies the understanding of the element in which it is contained and/or the understanding of the containing element's descendants. Usually modifier elements provide negation or qualification. To make the use of extensions safe and managable, there is a strict set of governance applied to the definition and use of extensions. Though any implementer can define an extension, there is a set of requirements that SHALL be met as part of the definition of the extension. Applications processing a resource are required to check for modifier extensions.

        Modifier extensions SHALL NOT change the meaning of any elements on Resource or DomainResource (including cannot change the meaning of modifierExtension itself).

        КороткийExtensions that cannot be ignored even if unrecognized
        Комментарии

        There can be no stigma associated with the use of extensions by any application, project, or standard - regardless of the institution or jurisdiction that uses or defines the extensions. The use of extensions is what allows the FHIR specification to retain a core level of simplicity for everyone.

        Контроль0..*
        ТипExtension
        Модификаторtrue потому что Modifier extensions are expected to modify the meaning or interpretation of the element that contains them
        Summarytrue
        Требования

        Modifier extensions allow for extensions that cannot be safely ignored to be clearly distinguished from the vast majority of extensions which can be safely ignored. This promotes interoperability by eliminating the need for implementers to prohibit the presence of extensions. For further information, see the definition of modifier extensions.

        Альтернативные именаextensions, user content, modifiers
        Инвариантыele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
        ext-1: Must have either extensions or value[x], not both (extension.exists() != value.exists())
        ele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
        ext-1: Must have either extensions or value[x], not both (extension.exists() != value.exists())
        101. Observation.component:birads.code
        Определение

        Describes what was observed. Sometimes this is called the observation "code".

        КороткийType of component observation (code / type)
        Комментарии

        All code-value and component.code-component.value pairs need to be taken into account to correctly understand the meaning of the observation.

        Контроль1..1
        На этот элемент влияют следующие инварианты: obs-7
        ПривязкаКоды СЛЕДУЕТ взять из Например, коды см. ObservationCodesVS (0.12.0)http://hl7.org/fhir/ValueSet/observation-codes|5.0.0
        (preferred to https://terminology.dhp.uz/fhir/core/ValueSet/observation-codes-vs|0.12.0)
        ТипCodeableConcept
        Модификаторfalse
        Требуется поддержкаtrue
        Summarytrue
        Требования

        Knowing what kind of observation is being made is essential to understanding the observation.

        Значение шаблона{
          "coding" : [{
            "system" : "http://snomed.info/sct",
            "code" : "1348266008"
          }]
        }
        Инвариантыele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
        ele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
        103. Observation.component:birads.value[x]
        Определение

        The information determined as a result of making the observation, if the information has a simple value.

        КороткийActual component result
        Комментарии

        Used when observation has a set of component observations:

        • An observation may have both a value (e.g. an Apgar score) and component observations (the observations from which the Apgar score was derived).
        • If a value is present, the datatype for this element should be determined by the code.
        • CodeableConcept with just a text would be used instead of a string if the field was usually coded, or if the type associated with the code defines a coded value.
        • Attachment is used if the observation result value is a binary file such as an image. If the observation result value is derived from the binary file (for example 'X' detected and here is the the proof in this image), the binary file may be directly represented using DocumentReference and referenced by derivedFrom.
        • If a value is present, the datatype for this element should be determined by the code.
        • CodeableConcept with just a text would be used instead of a string if the field was usually coded, or if the type associated with the code defines a coded value.
        • Attachment is used if the observation result value is a binary file such as an image. If the observation result value is derived from the binary file (for example 'X' detected and here is the the proof in this image), the binary file may be directly represented using DocumentReference and referenced by derivedFrom.
        • The usage of valueReference is restricted to the MolecularSequence resource when used as a definitional resource, not as a patient-specific finding. .
        • For additional guidance, see the Notes section below.
        Контроль0..1
        ПривязкаКоды ДОЛЖНЫ быть взяты из Информацию о кодах см. ScreeningBiradsVS (0.12.1)
        (required to https://terminology.dhp.uz/fhir/integrations/ValueSet/screening-birads-vs|0.12.1)
        ТипCodeableConcept, dateTime, string, Reference(MolecularSequence), Quantity, Period, Attachment, integer, Range, boolean, SampledData, Ratio, time
        [x] ЗаметкаСмотретьВыбор типов данныхдля дополнительной информации о том, как использовать [x]
        Модификаторfalse
        Требуется поддержкаtrue
        Summarytrue
        Требования

        An observation exists to have a value, though it might not if it is in error, or if it represents a group of observations.

        Инвариантыele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
        ele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
        105. Observation.component:breastDensity
        Название разрезаbreastDensity
        Определение

        Some observations have multiple component observations. These component observations are expressed as separate code value pairs that share the same attributes. Examples include systolic and diastolic component observations for blood pressure measurement and multiple component observations for genetics observations.

        КороткийMammographic breast density (mammography)Component results
        Комментарии

        For a discussion on the ways Observations can be assembled in groups together see Notes below.

        Контроль0..0*
        На этот элемент влияют следующие инварианты: obs-7
        ТипBackboneElement
        Модификаторfalse
        Требуется поддержкаtrue
        Summarytrue
        Требования

        Component observations share the same attributes in the Observation resource as the primary observation and are always treated a part of a single observation (they are not separable). However, the reference range for the primary observation value is not inherited by the component values and is required when appropriate for each component observation.

        Инвариантыele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
        ele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
        110. Observation.component:imageQuality
        Название разрезаimageQuality
        Определение

        Some observations have multiple component observations. These component observations are expressed as separate code value pairs that share the same attributes. Examples include systolic and diastolic component observations for blood pressure measurement and multiple component observations for genetics observations.

        КороткийImage quality (mammography)Component results
        Комментарии

        For a discussion on the ways Observations can be assembled in groups together see Notes below.

        Контроль0..0*
        На этот элемент влияют следующие инварианты: obs-7
        ТипBackboneElement
        Модификаторfalse
        Требуется поддержкаtrue
        Summarytrue
        Требования

        Component observations share the same attributes in the Observation resource as the primary observation and are always treated a part of a single observation (they are not separable). However, the reference range for the primary observation value is not inherited by the component values and is required when appropriate for each component observation.

        Инвариантыele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
        ele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
        115. Observation.component:breastFinding
        Название разрезаbreastFinding
        Определение

        Some observations have multiple component observations. These component observations are expressed as separate code value pairs that share the same attributes. Examples include systolic and diastolic component observations for blood pressure measurement and multiple component observations for genetics observations.

        КороткийBreast ultrasound findingComponent results
        Комментарии

        For a discussion on the ways Observations can be assembled in groups together see Notes below.

        Контроль0..*
        На этот элемент влияют следующие инварианты: obs-7
        ТипBackboneElement
        Модификаторfalse
        Требуется поддержкаtrue
        Summarytrue
        Требования

        Component observations share the same attributes in the Observation resource as the primary observation and are always treated a part of a single observation (they are not separable). However, the reference range for the primary observation value is not inherited by the component values and is required when appropriate for each component observation.

        Инвариантыele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
        ele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
        117. Observation.component:breastFinding.modifierExtension
        Определение

        May be used to represent additional information that is not part of the basic definition of the element and that modifies the understanding of the element in which it is contained and/or the understanding of the containing element's descendants. Usually modifier elements provide negation or qualification. To make the use of extensions safe and managable, there is a strict set of governance applied to the definition and use of extensions. Though any implementer can define an extension, there is a set of requirements that SHALL be met as part of the definition of the extension. Applications processing a resource are required to check for modifier extensions.

        Modifier extensions SHALL NOT change the meaning of any elements on Resource or DomainResource (including cannot change the meaning of modifierExtension itself).

        КороткийExtensions that cannot be ignored even if unrecognized
        Комментарии

        There can be no stigma associated with the use of extensions by any application, project, or standard - regardless of the institution or jurisdiction that uses or defines the extensions. The use of extensions is what allows the FHIR specification to retain a core level of simplicity for everyone.

        Контроль0..*
        ТипExtension
        Модификаторtrue потому что Modifier extensions are expected to modify the meaning or interpretation of the element that contains them
        Summarytrue
        Требования

        Modifier extensions allow for extensions that cannot be safely ignored to be clearly distinguished from the vast majority of extensions which can be safely ignored. This promotes interoperability by eliminating the need for implementers to prohibit the presence of extensions. For further information, see the definition of modifier extensions.

        Альтернативные именаextensions, user content, modifiers
        Инвариантыele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
        ext-1: Must have either extensions or value[x], not both (extension.exists() != value.exists())
        ele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
        ext-1: Must have either extensions or value[x], not both (extension.exists() != value.exists())
        119. Observation.component:breastFinding.code
        Определение

        Describes what was observed. Sometimes this is called the observation "code".

        КороткийType of component observation (code / type)
        Комментарии

        All code-value and component.code-component.value pairs need to be taken into account to correctly understand the meaning of the observation.

        Контроль1..1
        На этот элемент влияют следующие инварианты: obs-7
        ПривязкаКоды СЛЕДУЕТ взять из Например, коды см. ObservationCodesVS (0.12.0)http://hl7.org/fhir/ValueSet/observation-codes|5.0.0
        (preferred to https://terminology.dhp.uz/fhir/core/ValueSet/observation-codes-vs|0.12.0)
        ТипCodeableConcept
        Модификаторfalse
        Требуется поддержкаtrue
        Summarytrue
        Требования

        Knowing what kind of observation is being made is essential to understanding the observation.

        Значение шаблона{
          "coding" : [{
            "system" : "https://terminology.dhp.uz/fhir/integrations/CodeSystem/screening-specialized-observation-parameter-cs",
            "code" : "scrn-0073-00004"
          }]
        }
        Инвариантыele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
        ele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
        121. Observation.component:breastFinding.value[x]
        Определение

        The information determined as a result of making the observation, if the information has a simple value.

        КороткийActual component result
        Комментарии

        Used when observation has a set of component observations:

        • An observation may have both a value (e.g. an Apgar score) and component observations (the observations from which the Apgar score was derived).
        • If a value is present, the datatype for this element should be determined by the code.
        • CodeableConcept with just a text would be used instead of a string if the field was usually coded, or if the type associated with the code defines a coded value.
        • Attachment is used if the observation result value is a binary file such as an image. If the observation result value is derived from the binary file (for example 'X' detected and here is the the proof in this image), the binary file may be directly represented using DocumentReference and referenced by derivedFrom.
        • If a value is present, the datatype for this element should be determined by the code.
        • CodeableConcept with just a text would be used instead of a string if the field was usually coded, or if the type associated with the code defines a coded value.
        • Attachment is used if the observation result value is a binary file such as an image. If the observation result value is derived from the binary file (for example 'X' detected and here is the the proof in this image), the binary file may be directly represented using DocumentReference and referenced by derivedFrom.
        • The usage of valueReference is restricted to the MolecularSequence resource when used as a definitional resource, not as a patient-specific finding. .
        • For additional guidance, see the Notes section below.
        Контроль0..1
        ПривязкаКоды ДОЛЖНЫ быть взяты из Информацию о кодах см. ScreeningBreastFindingVS (0.12.1)
        (required to https://terminology.dhp.uz/fhir/integrations/ValueSet/screening-breast-finding-vs|0.12.1)
        ТипCodeableConcept, dateTime, string, Reference(MolecularSequence), Quantity, Period, Attachment, integer, Range, boolean, SampledData, Ratio, time
        [x] ЗаметкаСмотретьВыбор типов данныхдля дополнительной информации о том, как использовать [x]
        Модификаторfalse
        Требуется поддержкаtrue
        Summarytrue
        Требования

        An observation exists to have a value, though it might not if it is in error, or if it represents a group of observations.

        Инвариантыele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
        ele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
        123. Observation.component:breastSymmetry
        Название разрезаbreastSymmetry
        Определение

        Some observations have multiple component observations. These component observations are expressed as separate code value pairs that share the same attributes. Examples include systolic and diastolic component observations for blood pressure measurement and multiple component observations for genetics observations.

        КороткийBreast symmetryComponent results
        Комментарии

        For a discussion on the ways Observations can be assembled in groups together see Notes below.

        Контроль0..1*
        На этот элемент влияют следующие инварианты: obs-7
        ТипBackboneElement
        Модификаторfalse
        Требуется поддержкаtrue
        Summarytrue
        Требования

        Component observations share the same attributes in the Observation resource as the primary observation and are always treated a part of a single observation (they are not separable). However, the reference range for the primary observation value is not inherited by the component values and is required when appropriate for each component observation.

        Инвариантыele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
        ele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
        125. Observation.component:breastSymmetry.modifierExtension
        Определение

        May be used to represent additional information that is not part of the basic definition of the element and that modifies the understanding of the element in which it is contained and/or the understanding of the containing element's descendants. Usually modifier elements provide negation or qualification. To make the use of extensions safe and managable, there is a strict set of governance applied to the definition and use of extensions. Though any implementer can define an extension, there is a set of requirements that SHALL be met as part of the definition of the extension. Applications processing a resource are required to check for modifier extensions.

        Modifier extensions SHALL NOT change the meaning of any elements on Resource or DomainResource (including cannot change the meaning of modifierExtension itself).

        КороткийExtensions that cannot be ignored even if unrecognized
        Комментарии

        There can be no stigma associated with the use of extensions by any application, project, or standard - regardless of the institution or jurisdiction that uses or defines the extensions. The use of extensions is what allows the FHIR specification to retain a core level of simplicity for everyone.

        Контроль0..*
        ТипExtension
        Модификаторtrue потому что Modifier extensions are expected to modify the meaning or interpretation of the element that contains them
        Summarytrue
        Требования

        Modifier extensions allow for extensions that cannot be safely ignored to be clearly distinguished from the vast majority of extensions which can be safely ignored. This promotes interoperability by eliminating the need for implementers to prohibit the presence of extensions. For further information, see the definition of modifier extensions.

        Альтернативные именаextensions, user content, modifiers
        Инвариантыele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
        ext-1: Must have either extensions or value[x], not both (extension.exists() != value.exists())
        ele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
        ext-1: Must have either extensions or value[x], not both (extension.exists() != value.exists())
        127. Observation.component:breastSymmetry.code
        Определение

        Describes what was observed. Sometimes this is called the observation "code".

        КороткийType of component observation (code / type)
        Комментарии

        All code-value and component.code-component.value pairs need to be taken into account to correctly understand the meaning of the observation.

        Контроль1..1
        На этот элемент влияют следующие инварианты: obs-7
        ПривязкаКоды СЛЕДУЕТ взять из Например, коды см. ObservationCodesVS (0.12.0)http://hl7.org/fhir/ValueSet/observation-codes|5.0.0
        (preferred to https://terminology.dhp.uz/fhir/core/ValueSet/observation-codes-vs|0.12.0)
        ТипCodeableConcept
        Модификаторfalse
        Требуется поддержкаtrue
        Summarytrue
        Требования

        Knowing what kind of observation is being made is essential to understanding the observation.

        Значение шаблона{
          "coding" : [{
            "system" : "https://terminology.dhp.uz/fhir/integrations/CodeSystem/screening-ultrasound-parameter-cs",
            "code" : "scrn-0052-00004"
          }]
        }
        Инвариантыele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
        ele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
        129. Observation.component:breastSymmetry.value[x]
        Определение

        The information determined as a result of making the observation, if the information has a simple value.

        КороткийActual component result
        Комментарии

        Used when observation has a set of component observations:

        • An observation may have both a value (e.g. an Apgar score) and component observations (the observations from which the Apgar score was derived).
        • If a value is present, the datatype for this element should be determined by the code.
        • CodeableConcept with just a text would be used instead of a string if the field was usually coded, or if the type associated with the code defines a coded value.
        • Attachment is used if the observation result value is a binary file such as an image. If the observation result value is derived from the binary file (for example 'X' detected and here is the the proof in this image), the binary file may be directly represented using DocumentReference and referenced by derivedFrom.
        • If a value is present, the datatype for this element should be determined by the code.
        • CodeableConcept with just a text would be used instead of a string if the field was usually coded, or if the type associated with the code defines a coded value.
        • Attachment is used if the observation result value is a binary file such as an image. If the observation result value is derived from the binary file (for example 'X' detected and here is the the proof in this image), the binary file may be directly represented using DocumentReference and referenced by derivedFrom.
        • The usage of valueReference is restricted to the MolecularSequence resource when used as a definitional resource, not as a patient-specific finding. .
        • For additional guidance, see the Notes section below.
        Контроль0..1
        ПривязкаКоды ДОЛЖНЫ быть взяты из Информацию о кодах см. ScreeningUltrasoundBreastSymmetryVS (0.12.1)
        (required to https://terminology.dhp.uz/fhir/integrations/ValueSet/screening-ultrasound-breast-symmetry-vs|0.12.1)
        ТипCodeableConcept, dateTime, string, Reference(MolecularSequence), Quantity, Period, Attachment, integer, Range, boolean, SampledData, Ratio, time
        [x] ЗаметкаСмотретьВыбор типов данныхдля дополнительной информации о том, как использовать [x]
        Модификаторfalse
        Требуется поддержкаtrue
        Summarytrue
        Требования

        An observation exists to have a value, though it might not if it is in error, or if it represents a group of observations.

        Инвариантыele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
        ele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
        131. Observation.component:acrComposition
        Название разрезаacrComposition
        Определение

        Some observations have multiple component observations. These component observations are expressed as separate code value pairs that share the same attributes. Examples include systolic and diastolic component observations for blood pressure measurement and multiple component observations for genetics observations.

        КороткийACR breast compositionComponent results
        Комментарии

        For a discussion on the ways Observations can be assembled in groups together see Notes below.

        Контроль0..1*
        На этот элемент влияют следующие инварианты: obs-7
        ТипBackboneElement
        Модификаторfalse
        Требуется поддержкаtrue
        Summarytrue
        Требования

        Component observations share the same attributes in the Observation resource as the primary observation and are always treated a part of a single observation (they are not separable). However, the reference range for the primary observation value is not inherited by the component values and is required when appropriate for each component observation.

        Инвариантыele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
        ele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
        133. Observation.component:acrComposition.modifierExtension
        Определение

        May be used to represent additional information that is not part of the basic definition of the element and that modifies the understanding of the element in which it is contained and/or the understanding of the containing element's descendants. Usually modifier elements provide negation or qualification. To make the use of extensions safe and managable, there is a strict set of governance applied to the definition and use of extensions. Though any implementer can define an extension, there is a set of requirements that SHALL be met as part of the definition of the extension. Applications processing a resource are required to check for modifier extensions.

        Modifier extensions SHALL NOT change the meaning of any elements on Resource or DomainResource (including cannot change the meaning of modifierExtension itself).

        КороткийExtensions that cannot be ignored even if unrecognized
        Комментарии

        There can be no stigma associated with the use of extensions by any application, project, or standard - regardless of the institution or jurisdiction that uses or defines the extensions. The use of extensions is what allows the FHIR specification to retain a core level of simplicity for everyone.

        Контроль0..*
        ТипExtension
        Модификаторtrue потому что Modifier extensions are expected to modify the meaning or interpretation of the element that contains them
        Summarytrue
        Требования

        Modifier extensions allow for extensions that cannot be safely ignored to be clearly distinguished from the vast majority of extensions which can be safely ignored. This promotes interoperability by eliminating the need for implementers to prohibit the presence of extensions. For further information, see the definition of modifier extensions.

        Альтернативные именаextensions, user content, modifiers
        Инвариантыele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
        ext-1: Must have either extensions or value[x], not both (extension.exists() != value.exists())
        ele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
        ext-1: Must have either extensions or value[x], not both (extension.exists() != value.exists())
        135. Observation.component:acrComposition.code
        Определение

        Describes what was observed. Sometimes this is called the observation "code".

        КороткийType of component observation (code / type)
        Комментарии

        All code-value and component.code-component.value pairs need to be taken into account to correctly understand the meaning of the observation.

        Контроль1..1
        На этот элемент влияют следующие инварианты: obs-7
        ПривязкаКоды СЛЕДУЕТ взять из Например, коды см. ObservationCodesVS (0.12.0)http://hl7.org/fhir/ValueSet/observation-codes|5.0.0
        (preferred to https://terminology.dhp.uz/fhir/core/ValueSet/observation-codes-vs|0.12.0)
        ТипCodeableConcept
        Модификаторfalse
        Требуется поддержкаtrue
        Summarytrue
        Требования

        Knowing what kind of observation is being made is essential to understanding the observation.

        Значение шаблона{
          "coding" : [{
            "system" : "https://terminology.dhp.uz/fhir/integrations/CodeSystem/screening-ultrasound-parameter-cs",
            "code" : "scrn-0052-00005"
          }]
        }
        Инвариантыele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
        ele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
        137. Observation.component:acrComposition.value[x]
        Определение

        The information determined as a result of making the observation, if the information has a simple value.

        КороткийActual component result
        Комментарии

        Used when observation has a set of component observations:

        • An observation may have both a value (e.g. an Apgar score) and component observations (the observations from which the Apgar score was derived).
        • If a value is present, the datatype for this element should be determined by the code.
        • CodeableConcept with just a text would be used instead of a string if the field was usually coded, or if the type associated with the code defines a coded value.
        • Attachment is used if the observation result value is a binary file such as an image. If the observation result value is derived from the binary file (for example 'X' detected and here is the the proof in this image), the binary file may be directly represented using DocumentReference and referenced by derivedFrom.
        • If a value is present, the datatype for this element should be determined by the code.
        • CodeableConcept with just a text would be used instead of a string if the field was usually coded, or if the type associated with the code defines a coded value.
        • Attachment is used if the observation result value is a binary file such as an image. If the observation result value is derived from the binary file (for example 'X' detected and here is the the proof in this image), the binary file may be directly represented using DocumentReference and referenced by derivedFrom.
        • The usage of valueReference is restricted to the MolecularSequence resource when used as a definitional resource, not as a patient-specific finding. .
        • For additional guidance, see the Notes section below.
        Контроль0..1
        ПривязкаКоды ДОЛЖНЫ быть взяты из Информацию о кодах см. ScreeningUltrasoundAcrCompositionVS (0.12.1)
        (required to https://terminology.dhp.uz/fhir/integrations/ValueSet/screening-ultrasound-acr-composition-vs|0.12.1)
        ТипCodeableConcept, dateTime, string, Reference(MolecularSequence), Quantity, Period, Attachment, integer, Range, boolean, SampledData, Ratio, time
        [x] ЗаметкаСмотретьВыбор типов данныхдля дополнительной информации о том, как использовать [x]
        Модификаторfalse
        Требуется поддержкаtrue
        Summarytrue
        Требования

        An observation exists to have a value, though it might not if it is in error, or if it represents a group of observations.

        Инвариантыele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
        ele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
        139. Observation.component:skinNippleStatus
        Название разрезаskinNippleStatus
        Определение

        Some observations have multiple component observations. These component observations are expressed as separate code value pairs that share the same attributes. Examples include systolic and diastolic component observations for blood pressure measurement and multiple component observations for genetics observations.

        КороткийSkin and nipple statusComponent results
        Комментарии

        For a discussion on the ways Observations can be assembled in groups together see Notes below.

        Контроль0..1*
        На этот элемент влияют следующие инварианты: obs-7
        ТипBackboneElement
        Модификаторfalse
        Требуется поддержкаtrue
        Summarytrue
        Требования

        Component observations share the same attributes in the Observation resource as the primary observation and are always treated a part of a single observation (they are not separable). However, the reference range for the primary observation value is not inherited by the component values and is required when appropriate for each component observation.

        Инвариантыele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
        ele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
        141. Observation.component:skinNippleStatus.modifierExtension
        Определение

        May be used to represent additional information that is not part of the basic definition of the element and that modifies the understanding of the element in which it is contained and/or the understanding of the containing element's descendants. Usually modifier elements provide negation or qualification. To make the use of extensions safe and managable, there is a strict set of governance applied to the definition and use of extensions. Though any implementer can define an extension, there is a set of requirements that SHALL be met as part of the definition of the extension. Applications processing a resource are required to check for modifier extensions.

        Modifier extensions SHALL NOT change the meaning of any elements on Resource or DomainResource (including cannot change the meaning of modifierExtension itself).

        КороткийExtensions that cannot be ignored even if unrecognized
        Комментарии

        There can be no stigma associated with the use of extensions by any application, project, or standard - regardless of the institution or jurisdiction that uses or defines the extensions. The use of extensions is what allows the FHIR specification to retain a core level of simplicity for everyone.

        Контроль0..*
        ТипExtension
        Модификаторtrue потому что Modifier extensions are expected to modify the meaning or interpretation of the element that contains them
        Summarytrue
        Требования

        Modifier extensions allow for extensions that cannot be safely ignored to be clearly distinguished from the vast majority of extensions which can be safely ignored. This promotes interoperability by eliminating the need for implementers to prohibit the presence of extensions. For further information, see the definition of modifier extensions.

        Альтернативные именаextensions, user content, modifiers
        Инвариантыele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
        ext-1: Must have either extensions or value[x], not both (extension.exists() != value.exists())
        ele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
        ext-1: Must have either extensions or value[x], not both (extension.exists() != value.exists())
        143. Observation.component:skinNippleStatus.code
        Определение

        Describes what was observed. Sometimes this is called the observation "code".

        КороткийType of component observation (code / type)
        Комментарии

        All code-value and component.code-component.value pairs need to be taken into account to correctly understand the meaning of the observation.

        Контроль1..1
        На этот элемент влияют следующие инварианты: obs-7
        ПривязкаКоды СЛЕДУЕТ взять из Например, коды см. ObservationCodesVS (0.12.0)http://hl7.org/fhir/ValueSet/observation-codes|5.0.0
        (preferred to https://terminology.dhp.uz/fhir/core/ValueSet/observation-codes-vs|0.12.0)
        ТипCodeableConcept
        Модификаторfalse
        Требуется поддержкаtrue
        Summarytrue
        Требования

        Knowing what kind of observation is being made is essential to understanding the observation.

        Значение шаблона{
          "coding" : [{
            "system" : "https://terminology.dhp.uz/fhir/integrations/CodeSystem/screening-ultrasound-parameter-cs",
            "code" : "scrn-0052-00006"
          }]
        }
        Инвариантыele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
        ele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
        145. Observation.component:skinNippleStatus.value[x]
        Определение

        The information determined as a result of making the observation, if the information has a simple value.

        КороткийActual component result
        Комментарии

        Used when observation has a set of component observations:

        • An observation may have both a value (e.g. an Apgar score) and component observations (the observations from which the Apgar score was derived).
        • If a value is present, the datatype for this element should be determined by the code.
        • CodeableConcept with just a text would be used instead of a string if the field was usually coded, or if the type associated with the code defines a coded value.
        • Attachment is used if the observation result value is a binary file such as an image. If the observation result value is derived from the binary file (for example 'X' detected and here is the the proof in this image), the binary file may be directly represented using DocumentReference and referenced by derivedFrom.
        • If a value is present, the datatype for this element should be determined by the code.
        • CodeableConcept with just a text would be used instead of a string if the field was usually coded, or if the type associated with the code defines a coded value.
        • Attachment is used if the observation result value is a binary file such as an image. If the observation result value is derived from the binary file (for example 'X' detected and here is the the proof in this image), the binary file may be directly represented using DocumentReference and referenced by derivedFrom.
        • The usage of valueReference is restricted to the MolecularSequence resource when used as a definitional resource, not as a patient-specific finding. .
        • For additional guidance, see the Notes section below.
        Контроль0..1
        ПривязкаКоды ДОЛЖНЫ быть взяты из Информацию о кодах см. ScreeningUltrasoundSkinNippleStatusVS (0.12.1)
        (required to https://terminology.dhp.uz/fhir/integrations/ValueSet/screening-ultrasound-skin-nipple-status-vs|0.12.1)
        ТипCodeableConcept, dateTime, string, Reference(MolecularSequence), Quantity, Period, Attachment, integer, Range, boolean, SampledData, Ratio, time
        [x] ЗаметкаСмотретьВыбор типов данныхдля дополнительной информации о том, как использовать [x]
        Модификаторfalse
        Требуется поддержкаtrue
        Summarytrue
        Требования

        An observation exists to have a value, though it might not if it is in error, or if it represents a group of observations.

        Инвариантыele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
        ele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
        147. Observation.component:tissueDifferentiation
        Название разрезаtissueDifferentiation
        Определение

        Some observations have multiple component observations. These component observations are expressed as separate code value pairs that share the same attributes. Examples include systolic and diastolic component observations for blood pressure measurement and multiple component observations for genetics observations.

        КороткийTissue differentiationComponent results
        Комментарии

        For a discussion on the ways Observations can be assembled in groups together see Notes below.

        Контроль0..1*
        На этот элемент влияют следующие инварианты: obs-7
        ТипBackboneElement
        Модификаторfalse
        Требуется поддержкаtrue
        Summarytrue
        Требования

        Component observations share the same attributes in the Observation resource as the primary observation and are always treated a part of a single observation (they are not separable). However, the reference range for the primary observation value is not inherited by the component values and is required when appropriate for each component observation.

        Инвариантыele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
        ele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
        149. Observation.component:tissueDifferentiation.modifierExtension
        Определение

        May be used to represent additional information that is not part of the basic definition of the element and that modifies the understanding of the element in which it is contained and/or the understanding of the containing element's descendants. Usually modifier elements provide negation or qualification. To make the use of extensions safe and managable, there is a strict set of governance applied to the definition and use of extensions. Though any implementer can define an extension, there is a set of requirements that SHALL be met as part of the definition of the extension. Applications processing a resource are required to check for modifier extensions.

        Modifier extensions SHALL NOT change the meaning of any elements on Resource or DomainResource (including cannot change the meaning of modifierExtension itself).

        КороткийExtensions that cannot be ignored even if unrecognized
        Комментарии

        There can be no stigma associated with the use of extensions by any application, project, or standard - regardless of the institution or jurisdiction that uses or defines the extensions. The use of extensions is what allows the FHIR specification to retain a core level of simplicity for everyone.

        Контроль0..*
        ТипExtension
        Модификаторtrue потому что Modifier extensions are expected to modify the meaning or interpretation of the element that contains them
        Summarytrue
        Требования

        Modifier extensions allow for extensions that cannot be safely ignored to be clearly distinguished from the vast majority of extensions which can be safely ignored. This promotes interoperability by eliminating the need for implementers to prohibit the presence of extensions. For further information, see the definition of modifier extensions.

        Альтернативные именаextensions, user content, modifiers
        Инвариантыele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
        ext-1: Must have either extensions or value[x], not both (extension.exists() != value.exists())
        ele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
        ext-1: Must have either extensions or value[x], not both (extension.exists() != value.exists())
        151. Observation.component:tissueDifferentiation.code
        Определение

        Describes what was observed. Sometimes this is called the observation "code".

        КороткийType of component observation (code / type)
        Комментарии

        All code-value and component.code-component.value pairs need to be taken into account to correctly understand the meaning of the observation.

        Контроль1..1
        На этот элемент влияют следующие инварианты: obs-7
        ПривязкаКоды СЛЕДУЕТ взять из Например, коды см. ObservationCodesVS (0.12.0)http://hl7.org/fhir/ValueSet/observation-codes|5.0.0
        (preferred to https://terminology.dhp.uz/fhir/core/ValueSet/observation-codes-vs|0.12.0)
        ТипCodeableConcept
        Модификаторfalse
        Требуется поддержкаtrue
        Summarytrue
        Требования

        Knowing what kind of observation is being made is essential to understanding the observation.

        Значение шаблона{
          "coding" : [{
            "system" : "https://terminology.dhp.uz/fhir/integrations/CodeSystem/screening-ultrasound-parameter-cs",
            "code" : "scrn-0052-00007"
          }]
        }
        Инвариантыele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
        ele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
        153. Observation.component:tissueDifferentiation.value[x]
        Определение

        The information determined as a result of making the observation, if the information has a simple value.

        КороткийActual component result
        Комментарии

        Used when observation has a set of component observations:

        • An observation may have both a value (e.g. an Apgar score) and component observations (the observations from which the Apgar score was derived).
        • If a value is present, the datatype for this element should be determined by the code.
        • CodeableConcept with just a text would be used instead of a string if the field was usually coded, or if the type associated with the code defines a coded value.
        • Attachment is used if the observation result value is a binary file such as an image. If the observation result value is derived from the binary file (for example 'X' detected and here is the the proof in this image), the binary file may be directly represented using DocumentReference and referenced by derivedFrom.
        • If a value is present, the datatype for this element should be determined by the code.
        • CodeableConcept with just a text would be used instead of a string if the field was usually coded, or if the type associated with the code defines a coded value.
        • Attachment is used if the observation result value is a binary file such as an image. If the observation result value is derived from the binary file (for example 'X' detected and here is the the proof in this image), the binary file may be directly represented using DocumentReference and referenced by derivedFrom.
        • The usage of valueReference is restricted to the MolecularSequence resource when used as a definitional resource, not as a patient-specific finding. .
        • For additional guidance, see the Notes section below.
        Контроль0..1
        ПривязкаКоды ДОЛЖНЫ быть взяты из Информацию о кодах см. ScreeningUltrasoundTissueDifferentiationVS (0.12.1)
        (required to https://terminology.dhp.uz/fhir/integrations/ValueSet/screening-ultrasound-tissue-differentiation-vs|0.12.1)
        ТипCodeableConcept, dateTime, string, Reference(MolecularSequence), Quantity, Period, Attachment, integer, Range, boolean, SampledData, Ratio, time
        [x] ЗаметкаСмотретьВыбор типов данныхдля дополнительной информации о том, как использовать [x]
        Модификаторfalse
        Требуется поддержкаtrue
        Summarytrue
        Требования

        An observation exists to have a value, though it might not if it is in error, or if it represents a group of observations.

        Инвариантыele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
        ele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
        155. Observation.component:subcutaneousFat
        Название разрезаsubcutaneousFat
        Определение

        Some observations have multiple component observations. These component observations are expressed as separate code value pairs that share the same attributes. Examples include systolic and diastolic component observations for blood pressure measurement and multiple component observations for genetics observations.

        КороткийSubcutaneous fatComponent results
        Комментарии

        For a discussion on the ways Observations can be assembled in groups together see Notes below.

        Контроль0..1*
        На этот элемент влияют следующие инварианты: obs-7
        ТипBackboneElement
        Модификаторfalse
        Требуется поддержкаtrue
        Summarytrue
        Требования

        Component observations share the same attributes in the Observation resource as the primary observation and are always treated a part of a single observation (they are not separable). However, the reference range for the primary observation value is not inherited by the component values and is required when appropriate for each component observation.

        Инвариантыele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
        ele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
        157. Observation.component:subcutaneousFat.modifierExtension
        Определение

        May be used to represent additional information that is not part of the basic definition of the element and that modifies the understanding of the element in which it is contained and/or the understanding of the containing element's descendants. Usually modifier elements provide negation or qualification. To make the use of extensions safe and managable, there is a strict set of governance applied to the definition and use of extensions. Though any implementer can define an extension, there is a set of requirements that SHALL be met as part of the definition of the extension. Applications processing a resource are required to check for modifier extensions.

        Modifier extensions SHALL NOT change the meaning of any elements on Resource or DomainResource (including cannot change the meaning of modifierExtension itself).

        КороткийExtensions that cannot be ignored even if unrecognized
        Комментарии

        There can be no stigma associated with the use of extensions by any application, project, or standard - regardless of the institution or jurisdiction that uses or defines the extensions. The use of extensions is what allows the FHIR specification to retain a core level of simplicity for everyone.

        Контроль0..*
        ТипExtension
        Модификаторtrue потому что Modifier extensions are expected to modify the meaning or interpretation of the element that contains them
        Summarytrue
        Требования

        Modifier extensions allow for extensions that cannot be safely ignored to be clearly distinguished from the vast majority of extensions which can be safely ignored. This promotes interoperability by eliminating the need for implementers to prohibit the presence of extensions. For further information, see the definition of modifier extensions.

        Альтернативные именаextensions, user content, modifiers
        Инвариантыele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
        ext-1: Must have either extensions or value[x], not both (extension.exists() != value.exists())
        ele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
        ext-1: Must have either extensions or value[x], not both (extension.exists() != value.exists())
        159. Observation.component:subcutaneousFat.code
        Определение

        Describes what was observed. Sometimes this is called the observation "code".

        КороткийType of component observation (code / type)
        Комментарии

        All code-value and component.code-component.value pairs need to be taken into account to correctly understand the meaning of the observation.

        Контроль1..1
        На этот элемент влияют следующие инварианты: obs-7
        ПривязкаКоды СЛЕДУЕТ взять из Например, коды см. ObservationCodesVS (0.12.0)http://hl7.org/fhir/ValueSet/observation-codes|5.0.0
        (preferred to https://terminology.dhp.uz/fhir/core/ValueSet/observation-codes-vs|0.12.0)
        ТипCodeableConcept
        Модификаторfalse
        Требуется поддержкаtrue
        Summarytrue
        Требования

        Knowing what kind of observation is being made is essential to understanding the observation.

        Значение шаблона{
          "coding" : [{
            "system" : "https://terminology.dhp.uz/fhir/integrations/CodeSystem/screening-ultrasound-parameter-cs",
            "code" : "scrn-0052-00008"
          }]
        }
        Инвариантыele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
        ele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
        161. Observation.component:subcutaneousFat.value[x]
        Определение

        The information determined as a result of making the observation, if the information has a simple value.

        КороткийActual component result
        Комментарии

        Used when observation has a set of component observations:

        • An observation may have both a value (e.g. an Apgar score) and component observations (the observations from which the Apgar score was derived).
        • If a value is present, the datatype for this element should be determined by the code.
        • CodeableConcept with just a text would be used instead of a string if the field was usually coded, or if the type associated with the code defines a coded value.
        • Attachment is used if the observation result value is a binary file such as an image. If the observation result value is derived from the binary file (for example 'X' detected and here is the the proof in this image), the binary file may be directly represented using DocumentReference and referenced by derivedFrom.
        • If a value is present, the datatype for this element should be determined by the code.
        • CodeableConcept with just a text would be used instead of a string if the field was usually coded, or if the type associated with the code defines a coded value.
        • Attachment is used if the observation result value is a binary file such as an image. If the observation result value is derived from the binary file (for example 'X' detected and here is the the proof in this image), the binary file may be directly represented using DocumentReference and referenced by derivedFrom.
        • The usage of valueReference is restricted to the MolecularSequence resource when used as a definitional resource, not as a patient-specific finding. .
        • For additional guidance, see the Notes section below.
        Контроль0..1
        ПривязкаКоды ДОЛЖНЫ быть взяты из Информацию о кодах см. ScreeningUltrasoundSubcutaneousFatVS (0.12.1)
        (required to https://terminology.dhp.uz/fhir/integrations/ValueSet/screening-ultrasound-subcutaneous-fat-vs|0.12.1)
        ТипCodeableConcept, dateTime, string, Reference(MolecularSequence), Quantity, Period, Attachment, integer, Range, boolean, SampledData, Ratio, time
        [x] ЗаметкаСмотретьВыбор типов данныхдля дополнительной информации о том, как использовать [x]
        Модификаторfalse
        Требуется поддержкаtrue
        Summarytrue
        Требования

        An observation exists to have a value, though it might not if it is in error, or if it represents a group of observations.

        Инвариантыele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
        ele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
        163. Observation.component:fibroglandularEchogenicity
        Название разрезаfibroglandularEchogenicity
        Определение

        Some observations have multiple component observations. These component observations are expressed as separate code value pairs that share the same attributes. Examples include systolic and diastolic component observations for blood pressure measurement and multiple component observations for genetics observations.

        КороткийFibroglandular echogenicityComponent results
        Комментарии

        For a discussion on the ways Observations can be assembled in groups together see Notes below.

        Контроль0..1*
        На этот элемент влияют следующие инварианты: obs-7
        ТипBackboneElement
        Модификаторfalse
        Требуется поддержкаtrue
        Summarytrue
        Требования

        Component observations share the same attributes in the Observation resource as the primary observation and are always treated a part of a single observation (they are not separable). However, the reference range for the primary observation value is not inherited by the component values and is required when appropriate for each component observation.

        Инвариантыele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
        ele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
        165. Observation.component:fibroglandularEchogenicity.modifierExtension
        Определение

        May be used to represent additional information that is not part of the basic definition of the element and that modifies the understanding of the element in which it is contained and/or the understanding of the containing element's descendants. Usually modifier elements provide negation or qualification. To make the use of extensions safe and managable, there is a strict set of governance applied to the definition and use of extensions. Though any implementer can define an extension, there is a set of requirements that SHALL be met as part of the definition of the extension. Applications processing a resource are required to check for modifier extensions.

        Modifier extensions SHALL NOT change the meaning of any elements on Resource or DomainResource (including cannot change the meaning of modifierExtension itself).

        КороткийExtensions that cannot be ignored even if unrecognized
        Комментарии

        There can be no stigma associated with the use of extensions by any application, project, or standard - regardless of the institution or jurisdiction that uses or defines the extensions. The use of extensions is what allows the FHIR specification to retain a core level of simplicity for everyone.

        Контроль0..*
        ТипExtension
        Модификаторtrue потому что Modifier extensions are expected to modify the meaning or interpretation of the element that contains them
        Summarytrue
        Требования

        Modifier extensions allow for extensions that cannot be safely ignored to be clearly distinguished from the vast majority of extensions which can be safely ignored. This promotes interoperability by eliminating the need for implementers to prohibit the presence of extensions. For further information, see the definition of modifier extensions.

        Альтернативные именаextensions, user content, modifiers
        Инвариантыele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
        ext-1: Must have either extensions or value[x], not both (extension.exists() != value.exists())
        ele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
        ext-1: Must have either extensions or value[x], not both (extension.exists() != value.exists())
        167. Observation.component:fibroglandularEchogenicity.code
        Определение

        Describes what was observed. Sometimes this is called the observation "code".

        КороткийType of component observation (code / type)
        Комментарии

        All code-value and component.code-component.value pairs need to be taken into account to correctly understand the meaning of the observation.

        Контроль1..1
        На этот элемент влияют следующие инварианты: obs-7
        ПривязкаКоды СЛЕДУЕТ взять из Например, коды см. ObservationCodesVS (0.12.0)http://hl7.org/fhir/ValueSet/observation-codes|5.0.0
        (preferred to https://terminology.dhp.uz/fhir/core/ValueSet/observation-codes-vs|0.12.0)
        ТипCodeableConcept
        Модификаторfalse
        Требуется поддержкаtrue
        Summarytrue
        Требования

        Knowing what kind of observation is being made is essential to understanding the observation.

        Значение шаблона{
          "coding" : [{
            "system" : "https://terminology.dhp.uz/fhir/integrations/CodeSystem/screening-ultrasound-parameter-cs",
            "code" : "scrn-0052-00010"
          }]
        }
        Инвариантыele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
        ele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
        169. Observation.component:fibroglandularEchogenicity.value[x]
        Определение

        The information determined as a result of making the observation, if the information has a simple value.

        КороткийActual component result
        Комментарии

        Used when observation has a set of component observations:

        • An observation may have both a value (e.g. an Apgar score) and component observations (the observations from which the Apgar score was derived).
        • If a value is present, the datatype for this element should be determined by the code.
        • CodeableConcept with just a text would be used instead of a string if the field was usually coded, or if the type associated with the code defines a coded value.
        • Attachment is used if the observation result value is a binary file such as an image. If the observation result value is derived from the binary file (for example 'X' detected and here is the the proof in this image), the binary file may be directly represented using DocumentReference and referenced by derivedFrom.
        • If a value is present, the datatype for this element should be determined by the code.
        • CodeableConcept with just a text would be used instead of a string if the field was usually coded, or if the type associated with the code defines a coded value.
        • Attachment is used if the observation result value is a binary file such as an image. If the observation result value is derived from the binary file (for example 'X' detected and here is the the proof in this image), the binary file may be directly represented using DocumentReference and referenced by derivedFrom.
        • The usage of valueReference is restricted to the MolecularSequence resource when used as a definitional resource, not as a patient-specific finding. .
        • For additional guidance, see the Notes section below.
        Контроль0..1
        ПривязкаКоды ДОЛЖНЫ быть взяты из Информацию о кодах см. ScreeningUltrasoundFibroglandularEchogenicityVS (0.12.1)
        (required to https://terminology.dhp.uz/fhir/integrations/ValueSet/screening-ultrasound-fibroglandular-echogenicity-vs|0.12.1)
        ТипCodeableConcept, dateTime, string, Reference(MolecularSequence), Quantity, Period, Attachment, integer, Range, boolean, SampledData, Ratio, time
        [x] ЗаметкаСмотретьВыбор типов данныхдля дополнительной информации о том, как использовать [x]
        Модификаторfalse
        Требуется поддержкаtrue
        Summarytrue
        Требования

        An observation exists to have a value, though it might not if it is in error, or if it represents a group of observations.

        Инвариантыele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
        ele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
        171. Observation.component:ductStatus
        Название разрезаductStatus
        Определение

        Some observations have multiple component observations. These component observations are expressed as separate code value pairs that share the same attributes. Examples include systolic and diastolic component observations for blood pressure measurement and multiple component observations for genetics observations.

        КороткийDuct statusComponent results
        Комментарии

        For a discussion on the ways Observations can be assembled in groups together see Notes below.

        Контроль0..1*
        На этот элемент влияют следующие инварианты: obs-7
        ТипBackboneElement
        Модификаторfalse
        Требуется поддержкаtrue
        Summarytrue
        Требования

        Component observations share the same attributes in the Observation resource as the primary observation and are always treated a part of a single observation (they are not separable). However, the reference range for the primary observation value is not inherited by the component values and is required when appropriate for each component observation.

        Инвариантыele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
        ele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
        173. Observation.component:ductStatus.modifierExtension
        Определение

        May be used to represent additional information that is not part of the basic definition of the element and that modifies the understanding of the element in which it is contained and/or the understanding of the containing element's descendants. Usually modifier elements provide negation or qualification. To make the use of extensions safe and managable, there is a strict set of governance applied to the definition and use of extensions. Though any implementer can define an extension, there is a set of requirements that SHALL be met as part of the definition of the extension. Applications processing a resource are required to check for modifier extensions.

        Modifier extensions SHALL NOT change the meaning of any elements on Resource or DomainResource (including cannot change the meaning of modifierExtension itself).

        КороткийExtensions that cannot be ignored even if unrecognized
        Комментарии

        There can be no stigma associated with the use of extensions by any application, project, or standard - regardless of the institution or jurisdiction that uses or defines the extensions. The use of extensions is what allows the FHIR specification to retain a core level of simplicity for everyone.

        Контроль0..*
        ТипExtension
        Модификаторtrue потому что Modifier extensions are expected to modify the meaning or interpretation of the element that contains them
        Summarytrue
        Требования

        Modifier extensions allow for extensions that cannot be safely ignored to be clearly distinguished from the vast majority of extensions which can be safely ignored. This promotes interoperability by eliminating the need for implementers to prohibit the presence of extensions. For further information, see the definition of modifier extensions.

        Альтернативные именаextensions, user content, modifiers
        Инвариантыele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
        ext-1: Must have either extensions or value[x], not both (extension.exists() != value.exists())
        ele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
        ext-1: Must have either extensions or value[x], not both (extension.exists() != value.exists())
        175. Observation.component:ductStatus.code
        Определение

        Describes what was observed. Sometimes this is called the observation "code".

        КороткийType of component observation (code / type)
        Комментарии

        All code-value and component.code-component.value pairs need to be taken into account to correctly understand the meaning of the observation.

        Контроль1..1
        На этот элемент влияют следующие инварианты: obs-7
        ПривязкаКоды СЛЕДУЕТ взять из Например, коды см. ObservationCodesVS (0.12.0)http://hl7.org/fhir/ValueSet/observation-codes|5.0.0
        (preferred to https://terminology.dhp.uz/fhir/core/ValueSet/observation-codes-vs|0.12.0)
        ТипCodeableConcept
        Модификаторfalse
        Требуется поддержкаtrue
        Summarytrue
        Требования

        Knowing what kind of observation is being made is essential to understanding the observation.

        Значение шаблона{
          "coding" : [{
            "system" : "https://terminology.dhp.uz/fhir/integrations/CodeSystem/screening-ultrasound-parameter-cs",
            "code" : "scrn-0052-00012"
          }]
        }
        Инвариантыele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
        ele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
        177. Observation.component:ductStatus.value[x]
        Определение

        The information determined as a result of making the observation, if the information has a simple value.

        КороткийActual component result
        Комментарии

        Used when observation has a set of component observations:

        • An observation may have both a value (e.g. an Apgar score) and component observations (the observations from which the Apgar score was derived).
        • If a value is present, the datatype for this element should be determined by the code.
        • CodeableConcept with just a text would be used instead of a string if the field was usually coded, or if the type associated with the code defines a coded value.
        • Attachment is used if the observation result value is a binary file such as an image. If the observation result value is derived from the binary file (for example 'X' detected and here is the the proof in this image), the binary file may be directly represented using DocumentReference and referenced by derivedFrom.
        • If a value is present, the datatype for this element should be determined by the code.
        • CodeableConcept with just a text would be used instead of a string if the field was usually coded, or if the type associated with the code defines a coded value.
        • Attachment is used if the observation result value is a binary file such as an image. If the observation result value is derived from the binary file (for example 'X' detected and here is the the proof in this image), the binary file may be directly represented using DocumentReference and referenced by derivedFrom.
        • The usage of valueReference is restricted to the MolecularSequence resource when used as a definitional resource, not as a patient-specific finding. .
        • For additional guidance, see the Notes section below.
        Контроль0..1
        ПривязкаКоды ДОЛЖНЫ быть взяты из Информацию о кодах см. ScreeningUltrasoundDuctStatusVS (0.12.1)
        (required to https://terminology.dhp.uz/fhir/integrations/ValueSet/screening-ultrasound-duct-status-vs|0.12.1)
        ТипCodeableConcept, dateTime, string, Reference(MolecularSequence), Quantity, Period, Attachment, integer, Range, boolean, SampledData, Ratio, time
        [x] ЗаметкаСмотретьВыбор типов данныхдля дополнительной информации о том, как использовать [x]
        Модификаторfalse
        Требуется поддержкаtrue
        Summarytrue
        Требования

        An observation exists to have a value, though it might not if it is in error, or if it represents a group of observations.

        Инвариантыele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
        ele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
        179. Observation.component:retromammarySpace
        Название разрезаretromammarySpace
        Определение

        Some observations have multiple component observations. These component observations are expressed as separate code value pairs that share the same attributes. Examples include systolic and diastolic component observations for blood pressure measurement and multiple component observations for genetics observations.

        КороткийRetromammary spaceComponent results
        Комментарии

        For a discussion on the ways Observations can be assembled in groups together see Notes below.

        Контроль0..1*
        На этот элемент влияют следующие инварианты: obs-7
        ТипBackboneElement
        Модификаторfalse
        Требуется поддержкаtrue
        Summarytrue
        Требования

        Component observations share the same attributes in the Observation resource as the primary observation and are always treated a part of a single observation (they are not separable). However, the reference range for the primary observation value is not inherited by the component values and is required when appropriate for each component observation.

        Инвариантыele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
        ele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
        181. Observation.component:retromammarySpace.modifierExtension
        Определение

        May be used to represent additional information that is not part of the basic definition of the element and that modifies the understanding of the element in which it is contained and/or the understanding of the containing element's descendants. Usually modifier elements provide negation or qualification. To make the use of extensions safe and managable, there is a strict set of governance applied to the definition and use of extensions. Though any implementer can define an extension, there is a set of requirements that SHALL be met as part of the definition of the extension. Applications processing a resource are required to check for modifier extensions.

        Modifier extensions SHALL NOT change the meaning of any elements on Resource or DomainResource (including cannot change the meaning of modifierExtension itself).

        КороткийExtensions that cannot be ignored even if unrecognized
        Комментарии

        There can be no stigma associated with the use of extensions by any application, project, or standard - regardless of the institution or jurisdiction that uses or defines the extensions. The use of extensions is what allows the FHIR specification to retain a core level of simplicity for everyone.

        Контроль0..*
        ТипExtension
        Модификаторtrue потому что Modifier extensions are expected to modify the meaning or interpretation of the element that contains them
        Summarytrue
        Требования

        Modifier extensions allow for extensions that cannot be safely ignored to be clearly distinguished from the vast majority of extensions which can be safely ignored. This promotes interoperability by eliminating the need for implementers to prohibit the presence of extensions. For further information, see the definition of modifier extensions.

        Альтернативные именаextensions, user content, modifiers
        Инвариантыele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
        ext-1: Must have either extensions or value[x], not both (extension.exists() != value.exists())
        ele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
        ext-1: Must have either extensions or value[x], not both (extension.exists() != value.exists())
        183. Observation.component:retromammarySpace.code
        Определение

        Describes what was observed. Sometimes this is called the observation "code".

        КороткийType of component observation (code / type)
        Комментарии

        All code-value and component.code-component.value pairs need to be taken into account to correctly understand the meaning of the observation.

        Контроль1..1
        На этот элемент влияют следующие инварианты: obs-7
        ПривязкаКоды СЛЕДУЕТ взять из Например, коды см. ObservationCodesVS (0.12.0)http://hl7.org/fhir/ValueSet/observation-codes|5.0.0
        (preferred to https://terminology.dhp.uz/fhir/core/ValueSet/observation-codes-vs|0.12.0)
        ТипCodeableConcept
        Модификаторfalse
        Требуется поддержкаtrue
        Summarytrue
        Требования

        Knowing what kind of observation is being made is essential to understanding the observation.

        Значение шаблона{
          "coding" : [{
            "system" : "https://terminology.dhp.uz/fhir/integrations/CodeSystem/screening-ultrasound-parameter-cs",
            "code" : "scrn-0052-00013"
          }]
        }
        Инвариантыele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
        ele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
        185. Observation.component:retromammarySpace.value[x]
        Определение

        The information determined as a result of making the observation, if the information has a simple value.

        КороткийActual component result
        Комментарии

        Used when observation has a set of component observations:

        • An observation may have both a value (e.g. an Apgar score) and component observations (the observations from which the Apgar score was derived).
        • If a value is present, the datatype for this element should be determined by the code.
        • CodeableConcept with just a text would be used instead of a string if the field was usually coded, or if the type associated with the code defines a coded value.
        • Attachment is used if the observation result value is a binary file such as an image. If the observation result value is derived from the binary file (for example 'X' detected and here is the the proof in this image), the binary file may be directly represented using DocumentReference and referenced by derivedFrom.
        • If a value is present, the datatype for this element should be determined by the code.
        • CodeableConcept with just a text would be used instead of a string if the field was usually coded, or if the type associated with the code defines a coded value.
        • Attachment is used if the observation result value is a binary file such as an image. If the observation result value is derived from the binary file (for example 'X' detected and here is the the proof in this image), the binary file may be directly represented using DocumentReference and referenced by derivedFrom.
        • The usage of valueReference is restricted to the MolecularSequence resource when used as a definitional resource, not as a patient-specific finding. .
        • For additional guidance, see the Notes section below.
        Контроль0..1
        ПривязкаКоды ДОЛЖНЫ быть взяты из Информацию о кодах см. ScreeningUltrasoundRetromammarySpaceVS (0.12.1)
        (required to https://terminology.dhp.uz/fhir/integrations/ValueSet/screening-ultrasound-retromammary-space-vs|0.12.1)
        ТипCodeableConcept, dateTime, string, Reference(MolecularSequence), Quantity, Period, Attachment, integer, Range, boolean, SampledData, Ratio, time
        [x] ЗаметкаСмотретьВыбор типов данныхдля дополнительной информации о том, как использовать [x]
        Модификаторfalse
        Требуется поддержкаtrue
        Summarytrue
        Требования

        An observation exists to have a value, though it might not if it is in error, or if it represents a group of observations.

        Инвариантыele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
        ele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
        187. Observation.component:elastographyColorType
        Название разрезаelastographyColorType
        Определение

        Some observations have multiple component observations. These component observations are expressed as separate code value pairs that share the same attributes. Examples include systolic and diastolic component observations for blood pressure measurement and multiple component observations for genetics observations.

        КороткийElastography color typeComponent results
        Комментарии

        For a discussion on the ways Observations can be assembled in groups together see Notes below.

        Контроль0..1*
        На этот элемент влияют следующие инварианты: obs-7
        ТипBackboneElement
        Модификаторfalse
        Требуется поддержкаtrue
        Summarytrue
        Требования

        Component observations share the same attributes in the Observation resource as the primary observation and are always treated a part of a single observation (they are not separable). However, the reference range for the primary observation value is not inherited by the component values and is required when appropriate for each component observation.

        Инвариантыele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
        ele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
        189. Observation.component:elastographyColorType.modifierExtension
        Определение

        May be used to represent additional information that is not part of the basic definition of the element and that modifies the understanding of the element in which it is contained and/or the understanding of the containing element's descendants. Usually modifier elements provide negation or qualification. To make the use of extensions safe and managable, there is a strict set of governance applied to the definition and use of extensions. Though any implementer can define an extension, there is a set of requirements that SHALL be met as part of the definition of the extension. Applications processing a resource are required to check for modifier extensions.

        Modifier extensions SHALL NOT change the meaning of any elements on Resource or DomainResource (including cannot change the meaning of modifierExtension itself).

        КороткийExtensions that cannot be ignored even if unrecognized
        Комментарии

        There can be no stigma associated with the use of extensions by any application, project, or standard - regardless of the institution or jurisdiction that uses or defines the extensions. The use of extensions is what allows the FHIR specification to retain a core level of simplicity for everyone.

        Контроль0..*
        ТипExtension
        Модификаторtrue потому что Modifier extensions are expected to modify the meaning or interpretation of the element that contains them
        Summarytrue
        Требования

        Modifier extensions allow for extensions that cannot be safely ignored to be clearly distinguished from the vast majority of extensions which can be safely ignored. This promotes interoperability by eliminating the need for implementers to prohibit the presence of extensions. For further information, see the definition of modifier extensions.

        Альтернативные именаextensions, user content, modifiers
        Инвариантыele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
        ext-1: Must have either extensions or value[x], not both (extension.exists() != value.exists())
        ele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
        ext-1: Must have either extensions or value[x], not both (extension.exists() != value.exists())
        191. Observation.component:elastographyColorType.code
        Определение

        Describes what was observed. Sometimes this is called the observation "code".

        КороткийType of component observation (code / type)
        Комментарии

        All code-value and component.code-component.value pairs need to be taken into account to correctly understand the meaning of the observation.

        Контроль1..1
        На этот элемент влияют следующие инварианты: obs-7
        ПривязкаКоды СЛЕДУЕТ взять из Например, коды см. ObservationCodesVS (0.12.0)http://hl7.org/fhir/ValueSet/observation-codes|5.0.0
        (preferred to https://terminology.dhp.uz/fhir/core/ValueSet/observation-codes-vs|0.12.0)
        ТипCodeableConcept
        Модификаторfalse
        Требуется поддержкаtrue
        Summarytrue
        Требования

        Knowing what kind of observation is being made is essential to understanding the observation.

        Значение шаблона{
          "coding" : [{
            "system" : "https://terminology.dhp.uz/fhir/integrations/CodeSystem/screening-ultrasound-parameter-cs",
            "code" : "scrn-0052-00015"
          }]
        }
        Инвариантыele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
        ele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
        193. Observation.component:elastographyColorType.value[x]
        Определение

        The information determined as a result of making the observation, if the information has a simple value.

        КороткийActual component result
        Комментарии

        Used when observation has a set of component observations:

        • An observation may have both a value (e.g. an Apgar score) and component observations (the observations from which the Apgar score was derived).
        • If a value is present, the datatype for this element should be determined by the code.
        • CodeableConcept with just a text would be used instead of a string if the field was usually coded, or if the type associated with the code defines a coded value.
        • Attachment is used if the observation result value is a binary file such as an image. If the observation result value is derived from the binary file (for example 'X' detected and here is the the proof in this image), the binary file may be directly represented using DocumentReference and referenced by derivedFrom.
        • If a value is present, the datatype for this element should be determined by the code.
        • CodeableConcept with just a text would be used instead of a string if the field was usually coded, or if the type associated with the code defines a coded value.
        • Attachment is used if the observation result value is a binary file such as an image. If the observation result value is derived from the binary file (for example 'X' detected and here is the the proof in this image), the binary file may be directly represented using DocumentReference and referenced by derivedFrom.
        • The usage of valueReference is restricted to the MolecularSequence resource when used as a definitional resource, not as a patient-specific finding. .
        • For additional guidance, see the Notes section below.
        Контроль0..1
        ПривязкаКоды ДОЛЖНЫ быть взяты из Информацию о кодах см. ScreeningUltrasoundElastographyColorTypeVS (0.12.1)
        (required to https://terminology.dhp.uz/fhir/integrations/ValueSet/screening-ultrasound-elastography-color-type-vs|0.12.1)
        ТипCodeableConcept, dateTime, string, Reference(MolecularSequence), Quantity, Period, Attachment, integer, Range, boolean, SampledData, Ratio, time
        [x] ЗаметкаСмотретьВыбор типов данныхдля дополнительной информации о том, как использовать [x]
        Модификаторfalse
        Требуется поддержкаtrue
        Summarytrue
        Требования

        An observation exists to have a value, though it might not if it is in error, or if it represents a group of observations.

        Инвариантыele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
        ele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
        195. Observation.component:intramammaryNodeStatus
        Название разрезаintramammaryNodeStatus
        Определение

        Some observations have multiple component observations. These component observations are expressed as separate code value pairs that share the same attributes. Examples include systolic and diastolic component observations for blood pressure measurement and multiple component observations for genetics observations.

        КороткийIntramammary lymph node statusComponent results
        Комментарии

        For a discussion on the ways Observations can be assembled in groups together see Notes below.

        Контроль0..1*
        На этот элемент влияют следующие инварианты: obs-7
        ТипBackboneElement
        Модификаторfalse
        Требуется поддержкаtrue
        Summarytrue
        Требования

        Component observations share the same attributes in the Observation resource as the primary observation and are always treated a part of a single observation (they are not separable). However, the reference range for the primary observation value is not inherited by the component values and is required when appropriate for each component observation.

        Инвариантыele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
        ele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
        197. Observation.component:intramammaryNodeStatus.modifierExtension
        Определение

        May be used to represent additional information that is not part of the basic definition of the element and that modifies the understanding of the element in which it is contained and/or the understanding of the containing element's descendants. Usually modifier elements provide negation or qualification. To make the use of extensions safe and managable, there is a strict set of governance applied to the definition and use of extensions. Though any implementer can define an extension, there is a set of requirements that SHALL be met as part of the definition of the extension. Applications processing a resource are required to check for modifier extensions.

        Modifier extensions SHALL NOT change the meaning of any elements on Resource or DomainResource (including cannot change the meaning of modifierExtension itself).

        КороткийExtensions that cannot be ignored even if unrecognized
        Комментарии

        There can be no stigma associated with the use of extensions by any application, project, or standard - regardless of the institution or jurisdiction that uses or defines the extensions. The use of extensions is what allows the FHIR specification to retain a core level of simplicity for everyone.

        Контроль0..*
        ТипExtension
        Модификаторtrue потому что Modifier extensions are expected to modify the meaning or interpretation of the element that contains them
        Summarytrue
        Требования

        Modifier extensions allow for extensions that cannot be safely ignored to be clearly distinguished from the vast majority of extensions which can be safely ignored. This promotes interoperability by eliminating the need for implementers to prohibit the presence of extensions. For further information, see the definition of modifier extensions.

        Альтернативные именаextensions, user content, modifiers
        Инвариантыele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
        ext-1: Must have either extensions or value[x], not both (extension.exists() != value.exists())
        ele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
        ext-1: Must have either extensions or value[x], not both (extension.exists() != value.exists())
        199. Observation.component:intramammaryNodeStatus.code
        Определение

        Describes what was observed. Sometimes this is called the observation "code".

        КороткийType of component observation (code / type)
        Комментарии

        All code-value and component.code-component.value pairs need to be taken into account to correctly understand the meaning of the observation.

        Контроль1..1
        На этот элемент влияют следующие инварианты: obs-7
        ПривязкаКоды СЛЕДУЕТ взять из Например, коды см. ObservationCodesVS (0.12.0)http://hl7.org/fhir/ValueSet/observation-codes|5.0.0
        (preferred to https://terminology.dhp.uz/fhir/core/ValueSet/observation-codes-vs|0.12.0)
        ТипCodeableConcept
        Модификаторfalse
        Требуется поддержкаtrue
        Summarytrue
        Требования

        Knowing what kind of observation is being made is essential to understanding the observation.

        Значение шаблона{
          "coding" : [{
            "system" : "https://terminology.dhp.uz/fhir/integrations/CodeSystem/screening-ultrasound-parameter-cs",
            "code" : "scrn-0052-00016"
          }]
        }
        Инвариантыele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
        ele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
        201. Observation.component:intramammaryNodeStatus.value[x]
        Определение

        The information determined as a result of making the observation, if the information has a simple value.

        КороткийActual component result
        Комментарии

        Used when observation has a set of component observations:

        • An observation may have both a value (e.g. an Apgar score) and component observations (the observations from which the Apgar score was derived).
        • If a value is present, the datatype for this element should be determined by the code.
        • CodeableConcept with just a text would be used instead of a string if the field was usually coded, or if the type associated with the code defines a coded value.
        • Attachment is used if the observation result value is a binary file such as an image. If the observation result value is derived from the binary file (for example 'X' detected and here is the the proof in this image), the binary file may be directly represented using DocumentReference and referenced by derivedFrom.
        • If a value is present, the datatype for this element should be determined by the code.
        • CodeableConcept with just a text would be used instead of a string if the field was usually coded, or if the type associated with the code defines a coded value.
        • Attachment is used if the observation result value is a binary file such as an image. If the observation result value is derived from the binary file (for example 'X' detected and here is the the proof in this image), the binary file may be directly represented using DocumentReference and referenced by derivedFrom.
        • The usage of valueReference is restricted to the MolecularSequence resource when used as a definitional resource, not as a patient-specific finding. .
        • For additional guidance, see the Notes section below.
        Контроль0..1
        ПривязкаКоды ДОЛЖНЫ быть взяты из Информацию о кодах см. ScreeningUltrasoundIntramammaryNodeStatusVS (0.12.1)
        (required to https://terminology.dhp.uz/fhir/integrations/ValueSet/screening-ultrasound-intramammary-node-status-vs|0.12.1)
        ТипCodeableConcept, dateTime, string, Reference(MolecularSequence), Quantity, Period, Attachment, integer, Range, boolean, SampledData, Ratio, time
        [x] ЗаметкаСмотретьВыбор типов данныхдля дополнительной информации о том, как использовать [x]
        Модификаторfalse
        Требуется поддержкаtrue
        Summarytrue
        Требования

        An observation exists to have a value, though it might not if it is in error, or if it represents a group of observations.

        Инвариантыele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
        ele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
        203. Observation.component:axillaryNodeStatus
        Название разрезаaxillaryNodeStatus
        Определение

        Some observations have multiple component observations. These component observations are expressed as separate code value pairs that share the same attributes. Examples include systolic and diastolic component observations for blood pressure measurement and multiple component observations for genetics observations.

        КороткийAxillary lymph node statusComponent results
        Комментарии

        For a discussion on the ways Observations can be assembled in groups together see Notes below.

        Контроль0..1*
        На этот элемент влияют следующие инварианты: obs-7
        ТипBackboneElement
        Модификаторfalse
        Требуется поддержкаtrue
        Summarytrue
        Требования

        Component observations share the same attributes in the Observation resource as the primary observation and are always treated a part of a single observation (they are not separable). However, the reference range for the primary observation value is not inherited by the component values and is required when appropriate for each component observation.

        Инвариантыele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
        ele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
        205. Observation.component:axillaryNodeStatus.modifierExtension
        Определение

        May be used to represent additional information that is not part of the basic definition of the element and that modifies the understanding of the element in which it is contained and/or the understanding of the containing element's descendants. Usually modifier elements provide negation or qualification. To make the use of extensions safe and managable, there is a strict set of governance applied to the definition and use of extensions. Though any implementer can define an extension, there is a set of requirements that SHALL be met as part of the definition of the extension. Applications processing a resource are required to check for modifier extensions.

        Modifier extensions SHALL NOT change the meaning of any elements on Resource or DomainResource (including cannot change the meaning of modifierExtension itself).

        КороткийExtensions that cannot be ignored even if unrecognized
        Комментарии

        There can be no stigma associated with the use of extensions by any application, project, or standard - regardless of the institution or jurisdiction that uses or defines the extensions. The use of extensions is what allows the FHIR specification to retain a core level of simplicity for everyone.

        Контроль0..*
        ТипExtension
        Модификаторtrue потому что Modifier extensions are expected to modify the meaning or interpretation of the element that contains them
        Summarytrue
        Требования

        Modifier extensions allow for extensions that cannot be safely ignored to be clearly distinguished from the vast majority of extensions which can be safely ignored. This promotes interoperability by eliminating the need for implementers to prohibit the presence of extensions. For further information, see the definition of modifier extensions.

        Альтернативные именаextensions, user content, modifiers
        Инвариантыele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
        ext-1: Must have either extensions or value[x], not both (extension.exists() != value.exists())
        ele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
        ext-1: Must have either extensions or value[x], not both (extension.exists() != value.exists())
        207. Observation.component:axillaryNodeStatus.code
        Определение

        Describes what was observed. Sometimes this is called the observation "code".

        КороткийType of component observation (code / type)
        Комментарии

        All code-value and component.code-component.value pairs need to be taken into account to correctly understand the meaning of the observation.

        Контроль1..1
        На этот элемент влияют следующие инварианты: obs-7
        ПривязкаКоды СЛЕДУЕТ взять из Например, коды см. ObservationCodesVS (0.12.0)http://hl7.org/fhir/ValueSet/observation-codes|5.0.0
        (preferred to https://terminology.dhp.uz/fhir/core/ValueSet/observation-codes-vs|0.12.0)
        ТипCodeableConcept
        Модификаторfalse
        Требуется поддержкаtrue
        Summarytrue
        Требования

        Knowing what kind of observation is being made is essential to understanding the observation.

        Значение шаблона{
          "coding" : [{
            "system" : "https://terminology.dhp.uz/fhir/integrations/CodeSystem/screening-ultrasound-parameter-cs",
            "code" : "scrn-0052-00017"
          }]
        }
        Инвариантыele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
        ele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
        209. Observation.component:axillaryNodeStatus.value[x]
        Определение

        The information determined as a result of making the observation, if the information has a simple value.

        КороткийActual component result
        Комментарии

        Used when observation has a set of component observations:

        • An observation may have both a value (e.g. an Apgar score) and component observations (the observations from which the Apgar score was derived).
        • If a value is present, the datatype for this element should be determined by the code.
        • CodeableConcept with just a text would be used instead of a string if the field was usually coded, or if the type associated with the code defines a coded value.
        • Attachment is used if the observation result value is a binary file such as an image. If the observation result value is derived from the binary file (for example 'X' detected and here is the the proof in this image), the binary file may be directly represented using DocumentReference and referenced by derivedFrom.
        • If a value is present, the datatype for this element should be determined by the code.
        • CodeableConcept with just a text would be used instead of a string if the field was usually coded, or if the type associated with the code defines a coded value.
        • Attachment is used if the observation result value is a binary file such as an image. If the observation result value is derived from the binary file (for example 'X' detected and here is the the proof in this image), the binary file may be directly represented using DocumentReference and referenced by derivedFrom.
        • The usage of valueReference is restricted to the MolecularSequence resource when used as a definitional resource, not as a patient-specific finding. .
        • For additional guidance, see the Notes section below.
        Контроль0..1
        ПривязкаКоды ДОЛЖНЫ быть взяты из Информацию о кодах см. ScreeningUltrasoundAxillaryNodeStatusVS (0.12.1)
        (required to https://terminology.dhp.uz/fhir/integrations/ValueSet/screening-ultrasound-axillary-node-status-vs|0.12.1)
        ТипCodeableConcept, dateTime, string, Reference(MolecularSequence), Quantity, Period, Attachment, integer, Range, boolean, SampledData, Ratio, time
        [x] ЗаметкаСмотретьВыбор типов данныхдля дополнительной информации о том, как использовать [x]
        Модификаторfalse
        Требуется поддержкаtrue
        Summarytrue
        Требования

        An observation exists to have a value, though it might not if it is in error, or if it represents a group of observations.

        Инвариантыele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
        ele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
        211. Observation.component:axillaryNodeDifferentiation
        Название разрезаaxillaryNodeDifferentiation
        Определение

        Some observations have multiple component observations. These component observations are expressed as separate code value pairs that share the same attributes. Examples include systolic and diastolic component observations for blood pressure measurement and multiple component observations for genetics observations.

        КороткийAxillary lymph node differentiationComponent results
        Комментарии

        For a discussion on the ways Observations can be assembled in groups together see Notes below.

        Контроль0..1*
        На этот элемент влияют следующие инварианты: obs-7
        ТипBackboneElement
        Модификаторfalse
        Требуется поддержкаtrue
        Summarytrue
        Требования

        Component observations share the same attributes in the Observation resource as the primary observation and are always treated a part of a single observation (they are not separable). However, the reference range for the primary observation value is not inherited by the component values and is required when appropriate for each component observation.

        Инвариантыele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
        ele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
        213. Observation.component:axillaryNodeDifferentiation.modifierExtension
        Определение

        May be used to represent additional information that is not part of the basic definition of the element and that modifies the understanding of the element in which it is contained and/or the understanding of the containing element's descendants. Usually modifier elements provide negation or qualification. To make the use of extensions safe and managable, there is a strict set of governance applied to the definition and use of extensions. Though any implementer can define an extension, there is a set of requirements that SHALL be met as part of the definition of the extension. Applications processing a resource are required to check for modifier extensions.

        Modifier extensions SHALL NOT change the meaning of any elements on Resource or DomainResource (including cannot change the meaning of modifierExtension itself).

        КороткийExtensions that cannot be ignored even if unrecognized
        Комментарии

        There can be no stigma associated with the use of extensions by any application, project, or standard - regardless of the institution or jurisdiction that uses or defines the extensions. The use of extensions is what allows the FHIR specification to retain a core level of simplicity for everyone.

        Контроль0..*
        ТипExtension
        Модификаторtrue потому что Modifier extensions are expected to modify the meaning or interpretation of the element that contains them
        Summarytrue
        Требования

        Modifier extensions allow for extensions that cannot be safely ignored to be clearly distinguished from the vast majority of extensions which can be safely ignored. This promotes interoperability by eliminating the need for implementers to prohibit the presence of extensions. For further information, see the definition of modifier extensions.

        Альтернативные именаextensions, user content, modifiers
        Инвариантыele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
        ext-1: Must have either extensions or value[x], not both (extension.exists() != value.exists())
        ele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
        ext-1: Must have either extensions or value[x], not both (extension.exists() != value.exists())
        215. Observation.component:axillaryNodeDifferentiation.code
        Определение

        Describes what was observed. Sometimes this is called the observation "code".

        КороткийType of component observation (code / type)
        Комментарии

        All code-value and component.code-component.value pairs need to be taken into account to correctly understand the meaning of the observation.

        Контроль1..1
        На этот элемент влияют следующие инварианты: obs-7
        ПривязкаКоды СЛЕДУЕТ взять из Например, коды см. ObservationCodesVS (0.12.0)http://hl7.org/fhir/ValueSet/observation-codes|5.0.0
        (preferred to https://terminology.dhp.uz/fhir/core/ValueSet/observation-codes-vs|0.12.0)
        ТипCodeableConcept
        Модификаторfalse
        Требуется поддержкаtrue
        Summarytrue
        Требования

        Knowing what kind of observation is being made is essential to understanding the observation.

        Значение шаблона{
          "coding" : [{
            "system" : "https://terminology.dhp.uz/fhir/integrations/CodeSystem/screening-specialized-observation-parameter-cs",
            "code" : "scrn-0073-00016"
          }]
        }
        Инвариантыele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
        ele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
        217. Observation.component:axillaryNodeDifferentiation.value[x]
        Определение

        The information determined as a result of making the observation, if the information has a simple value.

        КороткийActual component result
        Комментарии

        Used when observation has a set of component observations:

        • An observation may have both a value (e.g. an Apgar score) and component observations (the observations from which the Apgar score was derived).
        • If a value is present, the datatype for this element should be determined by the code.
        • CodeableConcept with just a text would be used instead of a string if the field was usually coded, or if the type associated with the code defines a coded value.
        • Attachment is used if the observation result value is a binary file such as an image. If the observation result value is derived from the binary file (for example 'X' detected and here is the the proof in this image), the binary file may be directly represented using DocumentReference and referenced by derivedFrom.
        • If a value is present, the datatype for this element should be determined by the code.
        • CodeableConcept with just a text would be used instead of a string if the field was usually coded, or if the type associated with the code defines a coded value.
        • Attachment is used if the observation result value is a binary file such as an image. If the observation result value is derived from the binary file (for example 'X' detected and here is the the proof in this image), the binary file may be directly represented using DocumentReference and referenced by derivedFrom.
        • The usage of valueReference is restricted to the MolecularSequence resource when used as a definitional resource, not as a patient-specific finding. .
        • For additional guidance, see the Notes section below.
        Контроль0..1
        ПривязкаКоды ДОЛЖНЫ быть взяты из Информацию о кодах см. ScreeningUltrasoundAxillaryNodeDifferentiationVS (0.12.1)
        (required to https://terminology.dhp.uz/fhir/integrations/ValueSet/screening-ultrasound-axillary-node-differentiation-vs|0.12.1)
        ТипCodeableConcept, dateTime, string, Reference(MolecularSequence), Quantity, Period, Attachment, integer, Range, boolean, SampledData, Ratio, time
        [x] ЗаметкаСмотретьВыбор типов данныхдля дополнительной информации о том, как использовать [x]
        Модификаторfalse
        Требуется поддержкаtrue
        Summarytrue
        Требования

        An observation exists to have a value, though it might not if it is in error, or if it represents a group of observations.

        Инвариантыele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
        ele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
        219. Observation.component:regionalNodeStatus
        Название разрезаregionalNodeStatus
        Определение

        Some observations have multiple component observations. These component observations are expressed as separate code value pairs that share the same attributes. Examples include systolic and diastolic component observations for blood pressure measurement and multiple component observations for genetics observations.

        КороткийRegional lymph node statusComponent results
        Комментарии

        For a discussion on the ways Observations can be assembled in groups together see Notes below.

        Контроль0..1*
        На этот элемент влияют следующие инварианты: obs-7
        ТипBackboneElement
        Модификаторfalse
        Требуется поддержкаtrue
        Summarytrue
        Требования

        Component observations share the same attributes in the Observation resource as the primary observation and are always treated a part of a single observation (they are not separable). However, the reference range for the primary observation value is not inherited by the component values and is required when appropriate for each component observation.

        Инвариантыele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
        ele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
        221. Observation.component:regionalNodeStatus.modifierExtension
        Определение

        May be used to represent additional information that is not part of the basic definition of the element and that modifies the understanding of the element in which it is contained and/or the understanding of the containing element's descendants. Usually modifier elements provide negation or qualification. To make the use of extensions safe and managable, there is a strict set of governance applied to the definition and use of extensions. Though any implementer can define an extension, there is a set of requirements that SHALL be met as part of the definition of the extension. Applications processing a resource are required to check for modifier extensions.

        Modifier extensions SHALL NOT change the meaning of any elements on Resource or DomainResource (including cannot change the meaning of modifierExtension itself).

        КороткийExtensions that cannot be ignored even if unrecognized
        Комментарии

        There can be no stigma associated with the use of extensions by any application, project, or standard - regardless of the institution or jurisdiction that uses or defines the extensions. The use of extensions is what allows the FHIR specification to retain a core level of simplicity for everyone.

        Контроль0..*
        ТипExtension
        Модификаторtrue потому что Modifier extensions are expected to modify the meaning or interpretation of the element that contains them
        Summarytrue
        Требования

        Modifier extensions allow for extensions that cannot be safely ignored to be clearly distinguished from the vast majority of extensions which can be safely ignored. This promotes interoperability by eliminating the need for implementers to prohibit the presence of extensions. For further information, see the definition of modifier extensions.

        Альтернативные именаextensions, user content, modifiers
        Инвариантыele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
        ext-1: Must have either extensions or value[x], not both (extension.exists() != value.exists())
        ele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
        ext-1: Must have either extensions or value[x], not both (extension.exists() != value.exists())
        223. Observation.component:regionalNodeStatus.code
        Определение

        Describes what was observed. Sometimes this is called the observation "code".

        КороткийType of component observation (code / type)
        Комментарии

        All code-value and component.code-component.value pairs need to be taken into account to correctly understand the meaning of the observation.

        Контроль1..1
        На этот элемент влияют следующие инварианты: obs-7
        ПривязкаКоды СЛЕДУЕТ взять из Например, коды см. ObservationCodesVS (0.12.0)http://hl7.org/fhir/ValueSet/observation-codes|5.0.0
        (preferred to https://terminology.dhp.uz/fhir/core/ValueSet/observation-codes-vs|0.12.0)
        ТипCodeableConcept
        Модификаторfalse
        Требуется поддержкаtrue
        Summarytrue
        Требования

        Knowing what kind of observation is being made is essential to understanding the observation.

        Значение шаблона{
          "coding" : [{
            "system" : "https://terminology.dhp.uz/fhir/integrations/CodeSystem/screening-ultrasound-parameter-cs",
            "code" : "scrn-0052-00018"
          }]
        }
        Инвариантыele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
        ele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
        225. Observation.component:regionalNodeStatus.value[x]
        Определение

        The information determined as a result of making the observation, if the information has a simple value.

        КороткийActual component result
        Комментарии

        Used when observation has a set of component observations:

        • An observation may have both a value (e.g. an Apgar score) and component observations (the observations from which the Apgar score was derived).
        • If a value is present, the datatype for this element should be determined by the code.
        • CodeableConcept with just a text would be used instead of a string if the field was usually coded, or if the type associated with the code defines a coded value.
        • Attachment is used if the observation result value is a binary file such as an image. If the observation result value is derived from the binary file (for example 'X' detected and here is the the proof in this image), the binary file may be directly represented using DocumentReference and referenced by derivedFrom.
        • If a value is present, the datatype for this element should be determined by the code.
        • CodeableConcept with just a text would be used instead of a string if the field was usually coded, or if the type associated with the code defines a coded value.
        • Attachment is used if the observation result value is a binary file such as an image. If the observation result value is derived from the binary file (for example 'X' detected and here is the the proof in this image), the binary file may be directly represented using DocumentReference and referenced by derivedFrom.
        • The usage of valueReference is restricted to the MolecularSequence resource when used as a definitional resource, not as a patient-specific finding. .
        • For additional guidance, see the Notes section below.
        Контроль0..1
        ПривязкаКоды ДОЛЖНЫ быть взяты из Информацию о кодах см. ScreeningUltrasoundRegionalNodeStatusVS (0.12.1)
        (required to https://terminology.dhp.uz/fhir/integrations/ValueSet/screening-ultrasound-regional-node-status-vs|0.12.1)
        ТипCodeableConcept, dateTime, string, Reference(MolecularSequence), Quantity, Period, Attachment, integer, Range, boolean, SampledData, Ratio, time
        [x] ЗаметкаСмотретьВыбор типов данныхдля дополнительной информации о том, как использовать [x]
        Модификаторfalse
        Требуется поддержкаtrue
        Summarytrue
        Требования

        An observation exists to have a value, though it might not if it is in error, or if it represents a group of observations.

        Инвариантыele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
        ele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
        227. Observation.component:dynamics
        Название разрезаdynamics
        Определение

        Some observations have multiple component observations. These component observations are expressed as separate code value pairs that share the same attributes. Examples include systolic and diastolic component observations for blood pressure measurement and multiple component observations for genetics observations.

        КороткийComparison with previous studyComponent results
        Комментарии

        For a discussion on the ways Observations can be assembled in groups together see Notes below.

        Контроль0..1*
        На этот элемент влияют следующие инварианты: obs-7
        ТипBackboneElement
        Модификаторfalse
        Требуется поддержкаtrue
        Summarytrue
        Требования

        Component observations share the same attributes in the Observation resource as the primary observation and are always treated a part of a single observation (they are not separable). However, the reference range for the primary observation value is not inherited by the component values and is required when appropriate for each component observation.

        Инвариантыele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
        ele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
        229. Observation.component:dynamics.modifierExtension
        Определение

        May be used to represent additional information that is not part of the basic definition of the element and that modifies the understanding of the element in which it is contained and/or the understanding of the containing element's descendants. Usually modifier elements provide negation or qualification. To make the use of extensions safe and managable, there is a strict set of governance applied to the definition and use of extensions. Though any implementer can define an extension, there is a set of requirements that SHALL be met as part of the definition of the extension. Applications processing a resource are required to check for modifier extensions.

        Modifier extensions SHALL NOT change the meaning of any elements on Resource or DomainResource (including cannot change the meaning of modifierExtension itself).

        КороткийExtensions that cannot be ignored even if unrecognized
        Комментарии

        There can be no stigma associated with the use of extensions by any application, project, or standard - regardless of the institution or jurisdiction that uses or defines the extensions. The use of extensions is what allows the FHIR specification to retain a core level of simplicity for everyone.

        Контроль0..*
        ТипExtension
        Модификаторtrue потому что Modifier extensions are expected to modify the meaning or interpretation of the element that contains them
        Summarytrue
        Требования

        Modifier extensions allow for extensions that cannot be safely ignored to be clearly distinguished from the vast majority of extensions which can be safely ignored. This promotes interoperability by eliminating the need for implementers to prohibit the presence of extensions. For further information, see the definition of modifier extensions.

        Альтернативные именаextensions, user content, modifiers
        Инвариантыele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
        ext-1: Must have either extensions or value[x], not both (extension.exists() != value.exists())
        ele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
        ext-1: Must have either extensions or value[x], not both (extension.exists() != value.exists())
        231. Observation.component:dynamics.code
        Определение

        Describes what was observed. Sometimes this is called the observation "code".

        КороткийType of component observation (code / type)
        Комментарии

        All code-value and component.code-component.value pairs need to be taken into account to correctly understand the meaning of the observation.

        Контроль1..1
        На этот элемент влияют следующие инварианты: obs-7
        ПривязкаКоды СЛЕДУЕТ взять из Например, коды см. ObservationCodesVS (0.12.0)http://hl7.org/fhir/ValueSet/observation-codes|5.0.0
        (preferred to https://terminology.dhp.uz/fhir/core/ValueSet/observation-codes-vs|0.12.0)
        ТипCodeableConcept
        Модификаторfalse
        Требуется поддержкаtrue
        Summarytrue
        Требования

        Knowing what kind of observation is being made is essential to understanding the observation.

        Значение шаблона{
          "coding" : [{
            "system" : "https://terminology.dhp.uz/fhir/integrations/CodeSystem/screening-ultrasound-parameter-cs",
            "code" : "scrn-0052-00020"
          }]
        }
        Инвариантыele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
        ele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
        233. Observation.component:dynamics.value[x]
        Определение

        The information determined as a result of making the observation, if the information has a simple value.

        КороткийActual component result
        Комментарии

        Used when observation has a set of component observations:

        • An observation may have both a value (e.g. an Apgar score) and component observations (the observations from which the Apgar score was derived).
        • If a value is present, the datatype for this element should be determined by the code.
        • CodeableConcept with just a text would be used instead of a string if the field was usually coded, or if the type associated with the code defines a coded value.
        • Attachment is used if the observation result value is a binary file such as an image. If the observation result value is derived from the binary file (for example 'X' detected and here is the the proof in this image), the binary file may be directly represented using DocumentReference and referenced by derivedFrom.
        • If a value is present, the datatype for this element should be determined by the code.
        • CodeableConcept with just a text would be used instead of a string if the field was usually coded, or if the type associated with the code defines a coded value.
        • Attachment is used if the observation result value is a binary file such as an image. If the observation result value is derived from the binary file (for example 'X' detected and here is the the proof in this image), the binary file may be directly represented using DocumentReference and referenced by derivedFrom.
        • The usage of valueReference is restricted to the MolecularSequence resource when used as a definitional resource, not as a patient-specific finding. .
        • For additional guidance, see the Notes section below.
        Контроль0..1
        ПривязкаКоды ДОЛЖНЫ быть взяты из Информацию о кодах см. ScreeningUltrasoundDynamicsVS (0.12.1)
        (required to https://terminology.dhp.uz/fhir/integrations/ValueSet/screening-ultrasound-dynamics-vs|0.12.1)
        ТипCodeableConcept, dateTime, string, Reference(MolecularSequence), Quantity, Period, Attachment, integer, Range, boolean, SampledData, Ratio, time
        [x] ЗаметкаСмотретьВыбор типов данныхдля дополнительной информации о том, как использовать [x]
        Модификаторfalse
        Требуется поддержкаtrue
        Summarytrue
        Требования

        An observation exists to have a value, though it might not if it is in error, or if it represents a group of observations.

        Инвариантыele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
        ele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
        235. Observation.component:breastQuadrant
        Название разрезаbreastQuadrant
        Определение

        Some observations have multiple component observations. These component observations are expressed as separate code value pairs that share the same attributes. Examples include systolic and diastolic component observations for blood pressure measurement and multiple component observations for genetics observations.

        КороткийBreast quadrantComponent results
        Комментарии

        For a discussion on the ways Observations can be assembled in groups together see Notes below.

        Контроль0..1*
        На этот элемент влияют следующие инварианты: obs-7
        ТипBackboneElement
        Модификаторfalse
        Требуется поддержкаtrue
        Summarytrue
        Требования

        Component observations share the same attributes in the Observation resource as the primary observation and are always treated a part of a single observation (they are not separable). However, the reference range for the primary observation value is not inherited by the component values and is required when appropriate for each component observation.

        Инвариантыele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
        ele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
        237. Observation.component:breastQuadrant.modifierExtension
        Определение

        May be used to represent additional information that is not part of the basic definition of the element and that modifies the understanding of the element in which it is contained and/or the understanding of the containing element's descendants. Usually modifier elements provide negation or qualification. To make the use of extensions safe and managable, there is a strict set of governance applied to the definition and use of extensions. Though any implementer can define an extension, there is a set of requirements that SHALL be met as part of the definition of the extension. Applications processing a resource are required to check for modifier extensions.

        Modifier extensions SHALL NOT change the meaning of any elements on Resource or DomainResource (including cannot change the meaning of modifierExtension itself).

        КороткийExtensions that cannot be ignored even if unrecognized
        Комментарии

        There can be no stigma associated with the use of extensions by any application, project, or standard - regardless of the institution or jurisdiction that uses or defines the extensions. The use of extensions is what allows the FHIR specification to retain a core level of simplicity for everyone.

        Контроль0..*
        ТипExtension
        Модификаторtrue потому что Modifier extensions are expected to modify the meaning or interpretation of the element that contains them
        Summarytrue
        Требования

        Modifier extensions allow for extensions that cannot be safely ignored to be clearly distinguished from the vast majority of extensions which can be safely ignored. This promotes interoperability by eliminating the need for implementers to prohibit the presence of extensions. For further information, see the definition of modifier extensions.

        Альтернативные именаextensions, user content, modifiers
        Инвариантыele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
        ext-1: Must have either extensions or value[x], not both (extension.exists() != value.exists())
        ele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
        ext-1: Must have either extensions or value[x], not both (extension.exists() != value.exists())
        239. Observation.component:breastQuadrant.code
        Определение

        Describes what was observed. Sometimes this is called the observation "code".

        КороткийType of component observation (code / type)
        Комментарии

        All code-value and component.code-component.value pairs need to be taken into account to correctly understand the meaning of the observation.

        Контроль1..1
        На этот элемент влияют следующие инварианты: obs-7
        ПривязкаКоды СЛЕДУЕТ взять из Например, коды см. ObservationCodesVS (0.12.0)http://hl7.org/fhir/ValueSet/observation-codes|5.0.0
        (preferred to https://terminology.dhp.uz/fhir/core/ValueSet/observation-codes-vs|0.12.0)
        ТипCodeableConcept
        Модификаторfalse
        Требуется поддержкаtrue
        Summarytrue
        Требования

        Knowing what kind of observation is being made is essential to understanding the observation.

        Значение шаблона{
          "coding" : [{
            "system" : "https://terminology.dhp.uz/fhir/integrations/CodeSystem/screening-specialized-observation-parameter-cs",
            "code" : "scrn-0073-00015"
          }]
        }
        Инвариантыele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
        ele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
        241. Observation.component:breastQuadrant.value[x]
        Определение

        The information determined as a result of making the observation, if the information has a simple value.

        КороткийActual component result
        Комментарии

        Used when observation has a set of component observations:

        • An observation may have both a value (e.g. an Apgar score) and component observations (the observations from which the Apgar score was derived).
        • If a value is present, the datatype for this element should be determined by the code.
        • CodeableConcept with just a text would be used instead of a string if the field was usually coded, or if the type associated with the code defines a coded value.
        • Attachment is used if the observation result value is a binary file such as an image. If the observation result value is derived from the binary file (for example 'X' detected and here is the the proof in this image), the binary file may be directly represented using DocumentReference and referenced by derivedFrom.
        • If a value is present, the datatype for this element should be determined by the code.
        • CodeableConcept with just a text would be used instead of a string if the field was usually coded, or if the type associated with the code defines a coded value.
        • Attachment is used if the observation result value is a binary file such as an image. If the observation result value is derived from the binary file (for example 'X' detected and here is the the proof in this image), the binary file may be directly represented using DocumentReference and referenced by derivedFrom.
        • The usage of valueReference is restricted to the MolecularSequence resource when used as a definitional resource, not as a patient-specific finding. .
        • For additional guidance, see the Notes section below.
        Контроль0..1
        ПривязкаКоды ДОЛЖНЫ быть взяты из Информацию о кодах см. ScreeningUltrasoundBreastQuadrantVS (0.12.1)
        (required to https://terminology.dhp.uz/fhir/integrations/ValueSet/screening-ultrasound-breast-quadrant-vs|0.12.1)
        ТипCodeableConcept, dateTime, string, Reference(MolecularSequence), Quantity, Period, Attachment, integer, Range, boolean, SampledData, Ratio, time
        [x] ЗаметкаСмотретьВыбор типов данныхдля дополнительной информации о том, как использовать [x]
        Модификаторfalse
        Требуется поддержкаtrue
        Summarytrue
        Требования

        An observation exists to have a value, though it might not if it is in error, or if it represents a group of observations.

        Инвариантыele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
        ele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
        243. Observation.component:lesionShape
        Название разрезаlesionShape
        Определение

        Some observations have multiple component observations. These component observations are expressed as separate code value pairs that share the same attributes. Examples include systolic and diastolic component observations for blood pressure measurement and multiple component observations for genetics observations.

        КороткийLesion shapeComponent results
        Комментарии

        For a discussion on the ways Observations can be assembled in groups together see Notes below.

        Контроль0..1*
        На этот элемент влияют следующие инварианты: obs-7
        ТипBackboneElement
        Модификаторfalse
        Требуется поддержкаtrue
        Summarytrue
        Требования

        Component observations share the same attributes in the Observation resource as the primary observation and are always treated a part of a single observation (they are not separable). However, the reference range for the primary observation value is not inherited by the component values and is required when appropriate for each component observation.

        Инвариантыele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
        ele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
        245. Observation.component:lesionShape.modifierExtension
        Определение

        May be used to represent additional information that is not part of the basic definition of the element and that modifies the understanding of the element in which it is contained and/or the understanding of the containing element's descendants. Usually modifier elements provide negation or qualification. To make the use of extensions safe and managable, there is a strict set of governance applied to the definition and use of extensions. Though any implementer can define an extension, there is a set of requirements that SHALL be met as part of the definition of the extension. Applications processing a resource are required to check for modifier extensions.

        Modifier extensions SHALL NOT change the meaning of any elements on Resource or DomainResource (including cannot change the meaning of modifierExtension itself).

        КороткийExtensions that cannot be ignored even if unrecognized
        Комментарии

        There can be no stigma associated with the use of extensions by any application, project, or standard - regardless of the institution or jurisdiction that uses or defines the extensions. The use of extensions is what allows the FHIR specification to retain a core level of simplicity for everyone.

        Контроль0..*
        ТипExtension
        Модификаторtrue потому что Modifier extensions are expected to modify the meaning or interpretation of the element that contains them
        Summarytrue
        Требования

        Modifier extensions allow for extensions that cannot be safely ignored to be clearly distinguished from the vast majority of extensions which can be safely ignored. This promotes interoperability by eliminating the need for implementers to prohibit the presence of extensions. For further information, see the definition of modifier extensions.

        Альтернативные именаextensions, user content, modifiers
        Инвариантыele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
        ext-1: Must have either extensions or value[x], not both (extension.exists() != value.exists())
        ele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
        ext-1: Must have either extensions or value[x], not both (extension.exists() != value.exists())
        247. Observation.component:lesionShape.code
        Определение

        Describes what was observed. Sometimes this is called the observation "code".

        КороткийType of component observation (code / type)
        Комментарии

        All code-value and component.code-component.value pairs need to be taken into account to correctly understand the meaning of the observation.

        Контроль1..1
        На этот элемент влияют следующие инварианты: obs-7
        ПривязкаКоды СЛЕДУЕТ взять из Например, коды см. ObservationCodesVS (0.12.0)http://hl7.org/fhir/ValueSet/observation-codes|5.0.0
        (preferred to https://terminology.dhp.uz/fhir/core/ValueSet/observation-codes-vs|0.12.0)
        ТипCodeableConcept
        Модификаторfalse
        Требуется поддержкаtrue
        Summarytrue
        Требования

        Knowing what kind of observation is being made is essential to understanding the observation.

        Значение шаблона{
          "coding" : [{
            "system" : "https://terminology.dhp.uz/fhir/integrations/CodeSystem/screening-ultrasound-parameter-cs",
            "code" : "scrn-0052-00027"
          }]
        }
        Инвариантыele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
        ele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
        249. Observation.component:lesionShape.value[x]
        Определение

        The information determined as a result of making the observation, if the information has a simple value.

        КороткийActual component result
        Комментарии

        Used when observation has a set of component observations:

        • An observation may have both a value (e.g. an Apgar score) and component observations (the observations from which the Apgar score was derived).
        • If a value is present, the datatype for this element should be determined by the code.
        • CodeableConcept with just a text would be used instead of a string if the field was usually coded, or if the type associated with the code defines a coded value.
        • Attachment is used if the observation result value is a binary file such as an image. If the observation result value is derived from the binary file (for example 'X' detected and here is the the proof in this image), the binary file may be directly represented using DocumentReference and referenced by derivedFrom.
        • If a value is present, the datatype for this element should be determined by the code.
        • CodeableConcept with just a text would be used instead of a string if the field was usually coded, or if the type associated with the code defines a coded value.
        • Attachment is used if the observation result value is a binary file such as an image. If the observation result value is derived from the binary file (for example 'X' detected and here is the the proof in this image), the binary file may be directly represented using DocumentReference and referenced by derivedFrom.
        • The usage of valueReference is restricted to the MolecularSequence resource when used as a definitional resource, not as a patient-specific finding. .
        • For additional guidance, see the Notes section below.
        Контроль0..1
        ПривязкаКоды ДОЛЖНЫ быть взяты из Информацию о кодах см. ScreeningUltrasoundLesionShapeVS (0.12.1)
        (required to https://terminology.dhp.uz/fhir/integrations/ValueSet/screening-ultrasound-lesion-shape-vs|0.12.1)
        ТипCodeableConcept, dateTime, string, Reference(MolecularSequence), Quantity, Period, Attachment, integer, Range, boolean, SampledData, Ratio, time
        [x] ЗаметкаСмотретьВыбор типов данныхдля дополнительной информации о том, как использовать [x]
        Модификаторfalse
        Требуется поддержкаtrue
        Summarytrue
        Требования

        An observation exists to have a value, though it might not if it is in error, or if it represents a group of observations.

        Инвариантыele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
        ele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
        251. Observation.component:lesionOrientation
        Название разрезаlesionOrientation
        Определение

        Some observations have multiple component observations. These component observations are expressed as separate code value pairs that share the same attributes. Examples include systolic and diastolic component observations for blood pressure measurement and multiple component observations for genetics observations.

        КороткийLesion orientationComponent results
        Комментарии

        For a discussion on the ways Observations can be assembled in groups together see Notes below.

        Контроль0..1*
        На этот элемент влияют следующие инварианты: obs-7
        ТипBackboneElement
        Модификаторfalse
        Требуется поддержкаtrue
        Summarytrue
        Требования

        Component observations share the same attributes in the Observation resource as the primary observation and are always treated a part of a single observation (they are not separable). However, the reference range for the primary observation value is not inherited by the component values and is required when appropriate for each component observation.

        Инвариантыele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
        ele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
        253. Observation.component:lesionOrientation.modifierExtension
        Определение

        May be used to represent additional information that is not part of the basic definition of the element and that modifies the understanding of the element in which it is contained and/or the understanding of the containing element's descendants. Usually modifier elements provide negation or qualification. To make the use of extensions safe and managable, there is a strict set of governance applied to the definition and use of extensions. Though any implementer can define an extension, there is a set of requirements that SHALL be met as part of the definition of the extension. Applications processing a resource are required to check for modifier extensions.

        Modifier extensions SHALL NOT change the meaning of any elements on Resource or DomainResource (including cannot change the meaning of modifierExtension itself).

        КороткийExtensions that cannot be ignored even if unrecognized
        Комментарии

        There can be no stigma associated with the use of extensions by any application, project, or standard - regardless of the institution or jurisdiction that uses or defines the extensions. The use of extensions is what allows the FHIR specification to retain a core level of simplicity for everyone.

        Контроль0..*
        ТипExtension
        Модификаторtrue потому что Modifier extensions are expected to modify the meaning or interpretation of the element that contains them
        Summarytrue
        Требования

        Modifier extensions allow for extensions that cannot be safely ignored to be clearly distinguished from the vast majority of extensions which can be safely ignored. This promotes interoperability by eliminating the need for implementers to prohibit the presence of extensions. For further information, see the definition of modifier extensions.

        Альтернативные именаextensions, user content, modifiers
        Инвариантыele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
        ext-1: Must have either extensions or value[x], not both (extension.exists() != value.exists())
        ele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
        ext-1: Must have either extensions or value[x], not both (extension.exists() != value.exists())
        255. Observation.component:lesionOrientation.code
        Определение

        Describes what was observed. Sometimes this is called the observation "code".

        КороткийType of component observation (code / type)
        Комментарии

        All code-value and component.code-component.value pairs need to be taken into account to correctly understand the meaning of the observation.

        Контроль1..1
        На этот элемент влияют следующие инварианты: obs-7
        ПривязкаКоды СЛЕДУЕТ взять из Например, коды см. ObservationCodesVS (0.12.0)http://hl7.org/fhir/ValueSet/observation-codes|5.0.0
        (preferred to https://terminology.dhp.uz/fhir/core/ValueSet/observation-codes-vs|0.12.0)
        ТипCodeableConcept
        Модификаторfalse
        Требуется поддержкаtrue
        Summarytrue
        Требования

        Knowing what kind of observation is being made is essential to understanding the observation.

        Значение шаблона{
          "coding" : [{
            "system" : "https://terminology.dhp.uz/fhir/integrations/CodeSystem/screening-ultrasound-parameter-cs",
            "code" : "scrn-0052-00028"
          }]
        }
        Инвариантыele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
        ele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
        257. Observation.component:lesionOrientation.value[x]
        Определение

        The information determined as a result of making the observation, if the information has a simple value.

        КороткийActual component result
        Комментарии

        Used when observation has a set of component observations:

        • An observation may have both a value (e.g. an Apgar score) and component observations (the observations from which the Apgar score was derived).
        • If a value is present, the datatype for this element should be determined by the code.
        • CodeableConcept with just a text would be used instead of a string if the field was usually coded, or if the type associated with the code defines a coded value.
        • Attachment is used if the observation result value is a binary file such as an image. If the observation result value is derived from the binary file (for example 'X' detected and here is the the proof in this image), the binary file may be directly represented using DocumentReference and referenced by derivedFrom.
        • If a value is present, the datatype for this element should be determined by the code.
        • CodeableConcept with just a text would be used instead of a string if the field was usually coded, or if the type associated with the code defines a coded value.
        • Attachment is used if the observation result value is a binary file such as an image. If the observation result value is derived from the binary file (for example 'X' detected and here is the the proof in this image), the binary file may be directly represented using DocumentReference and referenced by derivedFrom.
        • The usage of valueReference is restricted to the MolecularSequence resource when used as a definitional resource, not as a patient-specific finding. .
        • For additional guidance, see the Notes section below.
        Контроль0..1
        ПривязкаКоды ДОЛЖНЫ быть взяты из Информацию о кодах см. ScreeningUltrasoundLesionOrientationVS (0.12.1)
        (required to https://terminology.dhp.uz/fhir/integrations/ValueSet/screening-ultrasound-lesion-orientation-vs|0.12.1)
        ТипCodeableConcept, dateTime, string, Reference(MolecularSequence), Quantity, Period, Attachment, integer, Range, boolean, SampledData, Ratio, time
        [x] ЗаметкаСмотретьВыбор типов данныхдля дополнительной информации о том, как использовать [x]
        Модификаторfalse
        Требуется поддержкаtrue
        Summarytrue
        Требования

        An observation exists to have a value, though it might not if it is in error, or if it represents a group of observations.

        Инвариантыele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
        ele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
        259. Observation.component:lesionContour
        Название разрезаlesionContour
        Определение

        Some observations have multiple component observations. These component observations are expressed as separate code value pairs that share the same attributes. Examples include systolic and diastolic component observations for blood pressure measurement and multiple component observations for genetics observations.

        КороткийLesion contourComponent results
        Комментарии

        For a discussion on the ways Observations can be assembled in groups together see Notes below.

        Контроль0..1*
        На этот элемент влияют следующие инварианты: obs-7
        ТипBackboneElement
        Модификаторfalse
        Требуется поддержкаtrue
        Summarytrue
        Требования

        Component observations share the same attributes in the Observation resource as the primary observation and are always treated a part of a single observation (they are not separable). However, the reference range for the primary observation value is not inherited by the component values and is required when appropriate for each component observation.

        Инвариантыele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
        ele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
        261. Observation.component:lesionContour.modifierExtension
        Определение

        May be used to represent additional information that is not part of the basic definition of the element and that modifies the understanding of the element in which it is contained and/or the understanding of the containing element's descendants. Usually modifier elements provide negation or qualification. To make the use of extensions safe and managable, there is a strict set of governance applied to the definition and use of extensions. Though any implementer can define an extension, there is a set of requirements that SHALL be met as part of the definition of the extension. Applications processing a resource are required to check for modifier extensions.

        Modifier extensions SHALL NOT change the meaning of any elements on Resource or DomainResource (including cannot change the meaning of modifierExtension itself).

        КороткийExtensions that cannot be ignored even if unrecognized
        Комментарии

        There can be no stigma associated with the use of extensions by any application, project, or standard - regardless of the institution or jurisdiction that uses or defines the extensions. The use of extensions is what allows the FHIR specification to retain a core level of simplicity for everyone.

        Контроль0..*
        ТипExtension
        Модификаторtrue потому что Modifier extensions are expected to modify the meaning or interpretation of the element that contains them
        Summarytrue
        Требования

        Modifier extensions allow for extensions that cannot be safely ignored to be clearly distinguished from the vast majority of extensions which can be safely ignored. This promotes interoperability by eliminating the need for implementers to prohibit the presence of extensions. For further information, see the definition of modifier extensions.

        Альтернативные именаextensions, user content, modifiers
        Инвариантыele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
        ext-1: Must have either extensions or value[x], not both (extension.exists() != value.exists())
        ele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
        ext-1: Must have either extensions or value[x], not both (extension.exists() != value.exists())
        263. Observation.component:lesionContour.code
        Определение

        Describes what was observed. Sometimes this is called the observation "code".

        КороткийType of component observation (code / type)
        Комментарии

        All code-value and component.code-component.value pairs need to be taken into account to correctly understand the meaning of the observation.

        Контроль1..1
        На этот элемент влияют следующие инварианты: obs-7
        ПривязкаКоды СЛЕДУЕТ взять из Например, коды см. ObservationCodesVS (0.12.0)http://hl7.org/fhir/ValueSet/observation-codes|5.0.0
        (preferred to https://terminology.dhp.uz/fhir/core/ValueSet/observation-codes-vs|0.12.0)
        ТипCodeableConcept
        Модификаторfalse
        Требуется поддержкаtrue
        Summarytrue
        Требования

        Knowing what kind of observation is being made is essential to understanding the observation.

        Значение шаблона{
          "coding" : [{
            "system" : "https://terminology.dhp.uz/fhir/integrations/CodeSystem/screening-ultrasound-parameter-cs",
            "code" : "scrn-0052-00029"
          }]
        }
        Инвариантыele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
        ele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
        265. Observation.component:lesionContour.value[x]
        Определение

        The information determined as a result of making the observation, if the information has a simple value.

        КороткийActual component result
        Комментарии

        Used when observation has a set of component observations:

        • An observation may have both a value (e.g. an Apgar score) and component observations (the observations from which the Apgar score was derived).
        • If a value is present, the datatype for this element should be determined by the code.
        • CodeableConcept with just a text would be used instead of a string if the field was usually coded, or if the type associated with the code defines a coded value.
        • Attachment is used if the observation result value is a binary file such as an image. If the observation result value is derived from the binary file (for example 'X' detected and here is the the proof in this image), the binary file may be directly represented using DocumentReference and referenced by derivedFrom.
        • If a value is present, the datatype for this element should be determined by the code.
        • CodeableConcept with just a text would be used instead of a string if the field was usually coded, or if the type associated with the code defines a coded value.
        • Attachment is used if the observation result value is a binary file such as an image. If the observation result value is derived from the binary file (for example 'X' detected and here is the the proof in this image), the binary file may be directly represented using DocumentReference and referenced by derivedFrom.
        • The usage of valueReference is restricted to the MolecularSequence resource when used as a definitional resource, not as a patient-specific finding. .
        • For additional guidance, see the Notes section below.
        Контроль0..1
        ПривязкаКоды ДОЛЖНЫ быть взяты из Информацию о кодах см. ScreeningUltrasoundLesionContourVS (0.12.1)
        (required to https://terminology.dhp.uz/fhir/integrations/ValueSet/screening-ultrasound-lesion-contour-vs|0.12.1)
        ТипCodeableConcept, dateTime, string, Reference(MolecularSequence), Quantity, Period, Attachment, integer, Range, boolean, SampledData, Ratio, time
        [x] ЗаметкаСмотретьВыбор типов данныхдля дополнительной информации о том, как использовать [x]
        Модификаторfalse
        Требуется поддержкаtrue
        Summarytrue
        Требования

        An observation exists to have a value, though it might not if it is in error, or if it represents a group of observations.

        Инвариантыele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
        ele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
        267. Observation.component:lesionEchogenicity
        Название разрезаlesionEchogenicity
        Определение

        Some observations have multiple component observations. These component observations are expressed as separate code value pairs that share the same attributes. Examples include systolic and diastolic component observations for blood pressure measurement and multiple component observations for genetics observations.

        КороткийLesion echogenicityComponent results
        Комментарии

        For a discussion on the ways Observations can be assembled in groups together see Notes below.

        Контроль0..1*
        На этот элемент влияют следующие инварианты: obs-7
        ТипBackboneElement
        Модификаторfalse
        Требуется поддержкаtrue
        Summarytrue
        Требования

        Component observations share the same attributes in the Observation resource as the primary observation and are always treated a part of a single observation (they are not separable). However, the reference range for the primary observation value is not inherited by the component values and is required when appropriate for each component observation.

        Инвариантыele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
        ele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
        269. Observation.component:lesionEchogenicity.modifierExtension
        Определение

        May be used to represent additional information that is not part of the basic definition of the element and that modifies the understanding of the element in which it is contained and/or the understanding of the containing element's descendants. Usually modifier elements provide negation or qualification. To make the use of extensions safe and managable, there is a strict set of governance applied to the definition and use of extensions. Though any implementer can define an extension, there is a set of requirements that SHALL be met as part of the definition of the extension. Applications processing a resource are required to check for modifier extensions.

        Modifier extensions SHALL NOT change the meaning of any elements on Resource or DomainResource (including cannot change the meaning of modifierExtension itself).

        КороткийExtensions that cannot be ignored even if unrecognized
        Комментарии

        There can be no stigma associated with the use of extensions by any application, project, or standard - regardless of the institution or jurisdiction that uses or defines the extensions. The use of extensions is what allows the FHIR specification to retain a core level of simplicity for everyone.

        Контроль0..*
        ТипExtension
        Модификаторtrue потому что Modifier extensions are expected to modify the meaning or interpretation of the element that contains them
        Summarytrue
        Требования

        Modifier extensions allow for extensions that cannot be safely ignored to be clearly distinguished from the vast majority of extensions which can be safely ignored. This promotes interoperability by eliminating the need for implementers to prohibit the presence of extensions. For further information, see the definition of modifier extensions.

        Альтернативные именаextensions, user content, modifiers
        Инвариантыele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
        ext-1: Must have either extensions or value[x], not both (extension.exists() != value.exists())
        ele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
        ext-1: Must have either extensions or value[x], not both (extension.exists() != value.exists())
        271. Observation.component:lesionEchogenicity.code
        Определение

        Describes what was observed. Sometimes this is called the observation "code".

        КороткийType of component observation (code / type)
        Комментарии

        All code-value and component.code-component.value pairs need to be taken into account to correctly understand the meaning of the observation.

        Контроль1..1
        На этот элемент влияют следующие инварианты: obs-7
        ПривязкаКоды СЛЕДУЕТ взять из Например, коды см. ObservationCodesVS (0.12.0)http://hl7.org/fhir/ValueSet/observation-codes|5.0.0
        (preferred to https://terminology.dhp.uz/fhir/core/ValueSet/observation-codes-vs|0.12.0)
        ТипCodeableConcept
        Модификаторfalse
        Требуется поддержкаtrue
        Summarytrue
        Требования

        Knowing what kind of observation is being made is essential to understanding the observation.

        Значение шаблона{
          "coding" : [{
            "system" : "https://terminology.dhp.uz/fhir/integrations/CodeSystem/screening-ultrasound-parameter-cs",
            "code" : "scrn-0052-00030"
          }]
        }
        Инвариантыele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
        ele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
        273. Observation.component:lesionEchogenicity.value[x]
        Определение

        The information determined as a result of making the observation, if the information has a simple value.

        КороткийActual component result
        Комментарии

        Used when observation has a set of component observations:

        • An observation may have both a value (e.g. an Apgar score) and component observations (the observations from which the Apgar score was derived).
        • If a value is present, the datatype for this element should be determined by the code.
        • CodeableConcept with just a text would be used instead of a string if the field was usually coded, or if the type associated with the code defines a coded value.
        • Attachment is used if the observation result value is a binary file such as an image. If the observation result value is derived from the binary file (for example 'X' detected and here is the the proof in this image), the binary file may be directly represented using DocumentReference and referenced by derivedFrom.
        • If a value is present, the datatype for this element should be determined by the code.
        • CodeableConcept with just a text would be used instead of a string if the field was usually coded, or if the type associated with the code defines a coded value.
        • Attachment is used if the observation result value is a binary file such as an image. If the observation result value is derived from the binary file (for example 'X' detected and here is the the proof in this image), the binary file may be directly represented using DocumentReference and referenced by derivedFrom.
        • The usage of valueReference is restricted to the MolecularSequence resource when used as a definitional resource, not as a patient-specific finding. .
        • For additional guidance, see the Notes section below.
        Контроль0..1
        ПривязкаКоды ДОЛЖНЫ быть взяты из Информацию о кодах см. ScreeningUltrasoundLesionEchogenicityVS (0.12.1)
        (required to https://terminology.dhp.uz/fhir/integrations/ValueSet/screening-ultrasound-lesion-echogenicity-vs|0.12.1)
        ТипCodeableConcept, dateTime, string, Reference(MolecularSequence), Quantity, Period, Attachment, integer, Range, boolean, SampledData, Ratio, time
        [x] ЗаметкаСмотретьВыбор типов данныхдля дополнительной информации о том, как использовать [x]
        Модификаторfalse
        Требуется поддержкаtrue
        Summarytrue
        Требования

        An observation exists to have a value, though it might not if it is in error, or if it represents a group of observations.

        Инвариантыele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
        ele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
        275. Observation.component:lesionAcousticEffect
        Название разрезаlesionAcousticEffect
        Определение

        Some observations have multiple component observations. These component observations are expressed as separate code value pairs that share the same attributes. Examples include systolic and diastolic component observations for blood pressure measurement and multiple component observations for genetics observations.

        КороткийLesion acoustic effectComponent results
        Комментарии

        For a discussion on the ways Observations can be assembled in groups together see Notes below.

        Контроль0..1*
        На этот элемент влияют следующие инварианты: obs-7
        ТипBackboneElement
        Модификаторfalse
        Требуется поддержкаtrue
        Summarytrue
        Требования

        Component observations share the same attributes in the Observation resource as the primary observation and are always treated a part of a single observation (they are not separable). However, the reference range for the primary observation value is not inherited by the component values and is required when appropriate for each component observation.

        Инвариантыele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
        ele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
        277. Observation.component:lesionAcousticEffect.modifierExtension
        Определение

        May be used to represent additional information that is not part of the basic definition of the element and that modifies the understanding of the element in which it is contained and/or the understanding of the containing element's descendants. Usually modifier elements provide negation or qualification. To make the use of extensions safe and managable, there is a strict set of governance applied to the definition and use of extensions. Though any implementer can define an extension, there is a set of requirements that SHALL be met as part of the definition of the extension. Applications processing a resource are required to check for modifier extensions.

        Modifier extensions SHALL NOT change the meaning of any elements on Resource or DomainResource (including cannot change the meaning of modifierExtension itself).

        КороткийExtensions that cannot be ignored even if unrecognized
        Комментарии

        There can be no stigma associated with the use of extensions by any application, project, or standard - regardless of the institution or jurisdiction that uses or defines the extensions. The use of extensions is what allows the FHIR specification to retain a core level of simplicity for everyone.

        Контроль0..*
        ТипExtension
        Модификаторtrue потому что Modifier extensions are expected to modify the meaning or interpretation of the element that contains them
        Summarytrue
        Требования

        Modifier extensions allow for extensions that cannot be safely ignored to be clearly distinguished from the vast majority of extensions which can be safely ignored. This promotes interoperability by eliminating the need for implementers to prohibit the presence of extensions. For further information, see the definition of modifier extensions.

        Альтернативные именаextensions, user content, modifiers
        Инвариантыele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
        ext-1: Must have either extensions or value[x], not both (extension.exists() != value.exists())
        ele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
        ext-1: Must have either extensions or value[x], not both (extension.exists() != value.exists())
        279. Observation.component:lesionAcousticEffect.code
        Определение

        Describes what was observed. Sometimes this is called the observation "code".

        КороткийType of component observation (code / type)
        Комментарии

        All code-value and component.code-component.value pairs need to be taken into account to correctly understand the meaning of the observation.

        Контроль1..1
        На этот элемент влияют следующие инварианты: obs-7
        ПривязкаКоды СЛЕДУЕТ взять из Например, коды см. ObservationCodesVS (0.12.0)http://hl7.org/fhir/ValueSet/observation-codes|5.0.0
        (preferred to https://terminology.dhp.uz/fhir/core/ValueSet/observation-codes-vs|0.12.0)
        ТипCodeableConcept
        Модификаторfalse
        Требуется поддержкаtrue
        Summarytrue
        Требования

        Knowing what kind of observation is being made is essential to understanding the observation.

        Значение шаблона{
          "coding" : [{
            "system" : "https://terminology.dhp.uz/fhir/integrations/CodeSystem/screening-ultrasound-parameter-cs",
            "code" : "scrn-0052-00036"
          }]
        }
        Инвариантыele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
        ele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
        281. Observation.component:lesionAcousticEffect.value[x]
        Определение

        The information determined as a result of making the observation, if the information has a simple value.

        КороткийActual component result
        Комментарии

        Used when observation has a set of component observations:

        • An observation may have both a value (e.g. an Apgar score) and component observations (the observations from which the Apgar score was derived).
        • If a value is present, the datatype for this element should be determined by the code.
        • CodeableConcept with just a text would be used instead of a string if the field was usually coded, or if the type associated with the code defines a coded value.
        • Attachment is used if the observation result value is a binary file such as an image. If the observation result value is derived from the binary file (for example 'X' detected and here is the the proof in this image), the binary file may be directly represented using DocumentReference and referenced by derivedFrom.
        • If a value is present, the datatype for this element should be determined by the code.
        • CodeableConcept with just a text would be used instead of a string if the field was usually coded, or if the type associated with the code defines a coded value.
        • Attachment is used if the observation result value is a binary file such as an image. If the observation result value is derived from the binary file (for example 'X' detected and here is the the proof in this image), the binary file may be directly represented using DocumentReference and referenced by derivedFrom.
        • The usage of valueReference is restricted to the MolecularSequence resource when used as a definitional resource, not as a patient-specific finding. .
        • For additional guidance, see the Notes section below.
        Контроль0..1
        ПривязкаКоды ДОЛЖНЫ быть взяты из Информацию о кодах см. ScreeningUltrasoundLesionAcousticEffectVS (0.12.1)
        (required to https://terminology.dhp.uz/fhir/integrations/ValueSet/screening-ultrasound-lesion-acoustic-effect-vs|0.12.1)
        ТипCodeableConcept, dateTime, string, Reference(MolecularSequence), Quantity, Period, Attachment, integer, Range, boolean, SampledData, Ratio, time
        [x] ЗаметкаСмотретьВыбор типов данныхдля дополнительной информации о том, как использовать [x]
        Модификаторfalse
        Требуется поддержкаtrue
        Summarytrue
        Требования

        An observation exists to have a value, though it might not if it is in error, or if it represents a group of observations.

        Инвариантыele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
        ele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
        283. Observation.component:lesionVascularization
        Название разрезаlesionVascularization
        Определение

        Some observations have multiple component observations. These component observations are expressed as separate code value pairs that share the same attributes. Examples include systolic and diastolic component observations for blood pressure measurement and multiple component observations for genetics observations.

        КороткийLesion vascularizationComponent results
        Комментарии

        For a discussion on the ways Observations can be assembled in groups together see Notes below.

        Контроль0..1*
        На этот элемент влияют следующие инварианты: obs-7
        ТипBackboneElement
        Модификаторfalse
        Требуется поддержкаtrue
        Summarytrue
        Требования

        Component observations share the same attributes in the Observation resource as the primary observation and are always treated a part of a single observation (they are not separable). However, the reference range for the primary observation value is not inherited by the component values and is required when appropriate for each component observation.

        Инвариантыele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
        ele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
        285. Observation.component:lesionVascularization.modifierExtension
        Определение

        May be used to represent additional information that is not part of the basic definition of the element and that modifies the understanding of the element in which it is contained and/or the understanding of the containing element's descendants. Usually modifier elements provide negation or qualification. To make the use of extensions safe and managable, there is a strict set of governance applied to the definition and use of extensions. Though any implementer can define an extension, there is a set of requirements that SHALL be met as part of the definition of the extension. Applications processing a resource are required to check for modifier extensions.

        Modifier extensions SHALL NOT change the meaning of any elements on Resource or DomainResource (including cannot change the meaning of modifierExtension itself).

        КороткийExtensions that cannot be ignored even if unrecognized
        Комментарии

        There can be no stigma associated with the use of extensions by any application, project, or standard - regardless of the institution or jurisdiction that uses or defines the extensions. The use of extensions is what allows the FHIR specification to retain a core level of simplicity for everyone.

        Контроль0..*
        ТипExtension
        Модификаторtrue потому что Modifier extensions are expected to modify the meaning or interpretation of the element that contains them
        Summarytrue
        Требования

        Modifier extensions allow for extensions that cannot be safely ignored to be clearly distinguished from the vast majority of extensions which can be safely ignored. This promotes interoperability by eliminating the need for implementers to prohibit the presence of extensions. For further information, see the definition of modifier extensions.

        Альтернативные именаextensions, user content, modifiers
        Инвариантыele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
        ext-1: Must have either extensions or value[x], not both (extension.exists() != value.exists())
        ele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
        ext-1: Must have either extensions or value[x], not both (extension.exists() != value.exists())
        287. Observation.component:lesionVascularization.code
        Определение

        Describes what was observed. Sometimes this is called the observation "code".

        КороткийType of component observation (code / type)
        Комментарии

        All code-value and component.code-component.value pairs need to be taken into account to correctly understand the meaning of the observation.

        Контроль1..1
        На этот элемент влияют следующие инварианты: obs-7
        ПривязкаКоды СЛЕДУЕТ взять из Например, коды см. ObservationCodesVS (0.12.0)http://hl7.org/fhir/ValueSet/observation-codes|5.0.0
        (preferred to https://terminology.dhp.uz/fhir/core/ValueSet/observation-codes-vs|0.12.0)
        ТипCodeableConcept
        Модификаторfalse
        Требуется поддержкаtrue
        Summarytrue
        Требования

        Knowing what kind of observation is being made is essential to understanding the observation.

        Значение шаблона{
          "coding" : [{
            "system" : "https://terminology.dhp.uz/fhir/integrations/CodeSystem/screening-ultrasound-parameter-cs",
            "code" : "scrn-0052-00037"
          }]
        }
        Инвариантыele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
        ele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
        289. Observation.component:lesionVascularization.value[x]
        Определение

        The information determined as a result of making the observation, if the information has a simple value.

        КороткийActual component result
        Комментарии

        Used when observation has a set of component observations:

        • An observation may have both a value (e.g. an Apgar score) and component observations (the observations from which the Apgar score was derived).
        • If a value is present, the datatype for this element should be determined by the code.
        • CodeableConcept with just a text would be used instead of a string if the field was usually coded, or if the type associated with the code defines a coded value.
        • Attachment is used if the observation result value is a binary file such as an image. If the observation result value is derived from the binary file (for example 'X' detected and here is the the proof in this image), the binary file may be directly represented using DocumentReference and referenced by derivedFrom.
        • If a value is present, the datatype for this element should be determined by the code.
        • CodeableConcept with just a text would be used instead of a string if the field was usually coded, or if the type associated with the code defines a coded value.
        • Attachment is used if the observation result value is a binary file such as an image. If the observation result value is derived from the binary file (for example 'X' detected and here is the the proof in this image), the binary file may be directly represented using DocumentReference and referenced by derivedFrom.
        • The usage of valueReference is restricted to the MolecularSequence resource when used as a definitional resource, not as a patient-specific finding. .
        • For additional guidance, see the Notes section below.
        Контроль0..1
        ПривязкаКоды ДОЛЖНЫ быть взяты из Информацию о кодах см. ScreeningUltrasoundLesionVascularizationVS (0.12.1)
        (required to https://terminology.dhp.uz/fhir/integrations/ValueSet/screening-ultrasound-lesion-vascularization-vs|0.12.1)
        ТипCodeableConcept, dateTime, string, Reference(MolecularSequence), Quantity, Period, Attachment, integer, Range, boolean, SampledData, Ratio, time
        [x] ЗаметкаСмотретьВыбор типов данныхдля дополнительной информации о том, как использовать [x]
        Модификаторfalse
        Требуется поддержкаtrue
        Summarytrue
        Требования

        An observation exists to have a value, though it might not if it is in error, or if it represents a group of observations.

        Инвариантыele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
        ele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
        291. Observation.component:menstrualCycleDuration
        Название разрезаmenstrualCycleDuration
        Определение

        Some observations have multiple component observations. These component observations are expressed as separate code value pairs that share the same attributes. Examples include systolic and diastolic component observations for blood pressure measurement and multiple component observations for genetics observations.

        КороткийMenstrual cycle durationComponent results
        Комментарии

        For a discussion on the ways Observations can be assembled in groups together see Notes below.

        Контроль0..1*
        На этот элемент влияют следующие инварианты: obs-7
        ТипBackboneElement
        Модификаторfalse
        Требуется поддержкаtrue
        Summarytrue
        Требования

        Component observations share the same attributes in the Observation resource as the primary observation and are always treated a part of a single observation (they are not separable). However, the reference range for the primary observation value is not inherited by the component values and is required when appropriate for each component observation.

        Инвариантыele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
        ele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
        293. Observation.component:menstrualCycleDuration.modifierExtension
        Определение

        May be used to represent additional information that is not part of the basic definition of the element and that modifies the understanding of the element in which it is contained and/or the understanding of the containing element's descendants. Usually modifier elements provide negation or qualification. To make the use of extensions safe and managable, there is a strict set of governance applied to the definition and use of extensions. Though any implementer can define an extension, there is a set of requirements that SHALL be met as part of the definition of the extension. Applications processing a resource are required to check for modifier extensions.

        Modifier extensions SHALL NOT change the meaning of any elements on Resource or DomainResource (including cannot change the meaning of modifierExtension itself).

        КороткийExtensions that cannot be ignored even if unrecognized
        Комментарии

        There can be no stigma associated with the use of extensions by any application, project, or standard - regardless of the institution or jurisdiction that uses or defines the extensions. The use of extensions is what allows the FHIR specification to retain a core level of simplicity for everyone.

        Контроль0..*
        ТипExtension
        Модификаторtrue потому что Modifier extensions are expected to modify the meaning or interpretation of the element that contains them
        Summarytrue
        Требования

        Modifier extensions allow for extensions that cannot be safely ignored to be clearly distinguished from the vast majority of extensions which can be safely ignored. This promotes interoperability by eliminating the need for implementers to prohibit the presence of extensions. For further information, see the definition of modifier extensions.

        Альтернативные именаextensions, user content, modifiers
        Инвариантыele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
        ext-1: Must have either extensions or value[x], not both (extension.exists() != value.exists())
        ele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
        ext-1: Must have either extensions or value[x], not both (extension.exists() != value.exists())
        295. Observation.component:menstrualCycleDuration.code
        Определение

        Describes what was observed. Sometimes this is called the observation "code".

        КороткийType of component observation (code / type)
        Комментарии

        All code-value and component.code-component.value pairs need to be taken into account to correctly understand the meaning of the observation.

        Контроль1..1
        На этот элемент влияют следующие инварианты: obs-7
        ПривязкаКоды СЛЕДУЕТ взять из Например, коды см. ObservationCodesVS (0.12.0)http://hl7.org/fhir/ValueSet/observation-codes|5.0.0
        (preferred to https://terminology.dhp.uz/fhir/core/ValueSet/observation-codes-vs|0.12.0)
        ТипCodeableConcept
        Модификаторfalse
        Требуется поддержкаtrue
        Summarytrue
        Требования

        Knowing what kind of observation is being made is essential to understanding the observation.

        Значение шаблона{
          "coding" : [{
            "system" : "https://terminology.dhp.uz/fhir/integrations/CodeSystem/screening-ultrasound-parameter-cs",
            "code" : "scrn-0052-00001"
          }]
        }
        Инвариантыele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
        ele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
        297. Observation.component:menstrualCycleDuration.value[x]
        Определение

        The information determined as a result of making the observation, if the information has a simple value.

        КороткийActual component result
        Комментарии

        Used when observation has a set of component observations:

        • An observation may have both a value (e.g. an Apgar score) and component observations (the observations from which the Apgar score was derived).
        • If a value is present, the datatype for this element should be determined by the code.
        • CodeableConcept with just a text would be used instead of a string if the field was usually coded, or if the type associated with the code defines a coded value.
        • Attachment is used if the observation result value is a binary file such as an image. If the observation result value is derived from the binary file (for example 'X' detected and here is the the proof in this image), the binary file may be directly represented using DocumentReference and referenced by derivedFrom.
        • If a value is present, the datatype for this element should be determined by the code.
        • CodeableConcept with just a text would be used instead of a string if the field was usually coded, or if the type associated with the code defines a coded value.
        • Attachment is used if the observation result value is a binary file such as an image. If the observation result value is derived from the binary file (for example 'X' detected and here is the the proof in this image), the binary file may be directly represented using DocumentReference and referenced by derivedFrom.
        • The usage of valueReference is restricted to the MolecularSequence resource when used as a definitional resource, not as a patient-specific finding. .
        • For additional guidance, see the Notes section below.
        Контроль10..1
        ТипQuantity, dateTime, string, Reference(MolecularSequence), Period, Attachment, integer, Range, boolean, SampledData, Ratio, time, CodeableConcept
        [x] ЗаметкаСмотретьВыбор типов данныхдля дополнительной информации о том, как использовать [x]
        Модификаторfalse
        Требуется поддержкаtrue
        Summarytrue
        Требования

        An observation exists to have a value, though it might not if it is in error, or if it represents a group of observations.

        Значение шаблона{
          "unit" : "d",
          "system" : "http://unitsofmeasure.org",
          "code" : "d"
        }
        Инвариантыele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
        ele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
        299. Observation.component:menstrualCycleDuration.value[x].value
        Определение

        The value of the measured amount. The value includes an implicit precision in the presentation of the value.

        КороткийNumerical value (with implicit precision)
        Комментарии

        The implicit precision in the value should always be honored. Monetary values have their own rules for handling precision (refer to standard accounting text books).

        Контроль10..1
        Типdecimal
        Модификаторfalse
        Примитивное значениеЭтот примитивный элемент может присутствовать или отсутствовать, или быть замененным расширением
        Summarytrue
        Требования

        Precision is handled implicitly in almost all cases of measurement.

        Мин. значение0
        Инвариантыele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
        ele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
        301. Observation.component:menstrualCycleDuration.value[x].comparator
        Определение

        How the value should be understood and represented - whether the actual value is greater or less than the stated value due to measurement issues; e.g. if the comparator is "<" , then the real value is < stated value.

        Короткий< | <= | >= | > | ad - how to understand the value
        Контроль0..1
        ПривязкаКоды ДОЛЖНЫ быть взяты из QuantityComparatorhttp://hl7.org/fhir/ValueSet/quantity-comparator|5.0.0
        (required to http://hl7.org/fhir/ValueSet/quantity-comparator|5.0.0)

        How the Quantity should be understood and represented.

        Типcode
        Модификаторtrue потому что This is labeled as "Is Modifier" because the comparator modifies the interpretation of the value significantly. If there is no comparator, then there is no modification of the value
        Примитивное значениеЭтот примитивный элемент может присутствовать или отсутствовать, или быть замененным расширением
        Summarytrue
        Требования

        Need a framework for handling measures where the value is <5ug/L or >400mg/L due to the limitations of measuring methodology.

        Значение при отсутствииIf there is no comparator, then there is no modification of the value
        Инвариантыele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
        ele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
        303. Observation.component:menstrualCycleDuration.value[x].unit
        Определение

        A human-readable form of the unit.

        КороткийUnit representation
        Контроль10..1
        Типstring
        Модификаторfalse
        Примитивное значениеЭтот примитивный элемент может присутствовать или отсутствовать, или быть замененным расширением
        Summarytrue
        Требования

        There are many representations for units of measure and in many contexts, particular representations are fixed and required. I.e. mcg for micrograms.

        Инвариантыele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
        ele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
        305. Observation.component:menstrualCycleDuration.value[x].system
        Определение

        The identification of the system that provides the coded form of the unit.

        КороткийSystem that defines coded unit form
        Контроль10..1
        На этот элемент влияют следующие инварианты: qty-3
        Типuri
        Модификаторfalse
        Примитивное значениеЭтот примитивный элемент может присутствовать или отсутствовать, или быть замененным расширением
        Summarytrue
        Требования

        Need to know the system that defines the coded form of the unit.

        Инвариантыele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
        ele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
        307. Observation.component:menstrualCycleDuration.value[x].code
        Определение

        A computer processable form of the unit in some unit representation system.

        КороткийCoded form of the unit
        Комментарии

        The preferred system is UCUM, but SNOMED CT can also be used (for customary units) or ISO 4217 for currency. The context of use may additionally require a code from a particular system.

        Контроль10..1
        На этот элемент влияют следующие инварианты: qty-3
        Типcode
        Модификаторfalse
        Примитивное значениеЭтот примитивный элемент может присутствовать или отсутствовать, или быть замененным расширением
        Summarytrue
        Требования

        Need a computable form of the unit that is fixed across all forms. UCUM provides this for quantities, but SNOMED CT provides many units of interest.

        Инвариантыele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
        ele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
        309. Observation.component:anamnesis
        Название разрезаanamnesis
        Определение

        Some observations have multiple component observations. These component observations are expressed as separate code value pairs that share the same attributes. Examples include systolic and diastolic component observations for blood pressure measurement and multiple component observations for genetics observations.

        КороткийUltrasound anamnesisComponent results
        Комментарии

        For a discussion on the ways Observations can be assembled in groups together see Notes below.

        Контроль0..1*
        На этот элемент влияют следующие инварианты: obs-7
        ТипBackboneElement
        Модификаторfalse
        Требуется поддержкаtrue
        Summarytrue
        Требования

        Component observations share the same attributes in the Observation resource as the primary observation and are always treated a part of a single observation (they are not separable). However, the reference range for the primary observation value is not inherited by the component values and is required when appropriate for each component observation.

        Инвариантыele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
        ele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
        311. Observation.component:anamnesis.modifierExtension
        Определение

        May be used to represent additional information that is not part of the basic definition of the element and that modifies the understanding of the element in which it is contained and/or the understanding of the containing element's descendants. Usually modifier elements provide negation or qualification. To make the use of extensions safe and managable, there is a strict set of governance applied to the definition and use of extensions. Though any implementer can define an extension, there is a set of requirements that SHALL be met as part of the definition of the extension. Applications processing a resource are required to check for modifier extensions.

        Modifier extensions SHALL NOT change the meaning of any elements on Resource or DomainResource (including cannot change the meaning of modifierExtension itself).

        КороткийExtensions that cannot be ignored even if unrecognized
        Комментарии

        There can be no stigma associated with the use of extensions by any application, project, or standard - regardless of the institution or jurisdiction that uses or defines the extensions. The use of extensions is what allows the FHIR specification to retain a core level of simplicity for everyone.

        Контроль0..*
        ТипExtension
        Модификаторtrue потому что Modifier extensions are expected to modify the meaning or interpretation of the element that contains them
        Summarytrue
        Требования

        Modifier extensions allow for extensions that cannot be safely ignored to be clearly distinguished from the vast majority of extensions which can be safely ignored. This promotes interoperability by eliminating the need for implementers to prohibit the presence of extensions. For further information, see the definition of modifier extensions.

        Альтернативные именаextensions, user content, modifiers
        Инвариантыele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
        ext-1: Must have either extensions or value[x], not both (extension.exists() != value.exists())
        ele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
        ext-1: Must have either extensions or value[x], not both (extension.exists() != value.exists())
        313. Observation.component:anamnesis.code
        Определение

        Describes what was observed. Sometimes this is called the observation "code".

        КороткийType of component observation (code / type)
        Комментарии

        All code-value and component.code-component.value pairs need to be taken into account to correctly understand the meaning of the observation.

        Контроль1..1
        На этот элемент влияют следующие инварианты: obs-7
        ПривязкаКоды СЛЕДУЕТ взять из Например, коды см. ObservationCodesVS (0.12.0)http://hl7.org/fhir/ValueSet/observation-codes|5.0.0
        (preferred to https://terminology.dhp.uz/fhir/core/ValueSet/observation-codes-vs|0.12.0)
        ТипCodeableConcept
        Модификаторfalse
        Требуется поддержкаtrue
        Summarytrue
        Требования

        Knowing what kind of observation is being made is essential to understanding the observation.

        Значение шаблона{
          "coding" : [{
            "system" : "https://terminology.dhp.uz/fhir/integrations/CodeSystem/screening-ultrasound-parameter-cs",
            "code" : "scrn-0052-00003"
          }]
        }
        Инвариантыele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
        ele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
        315. Observation.component:anamnesis.value[x]
        Определение

        The information determined as a result of making the observation, if the information has a simple value.

        КороткийActual component result
        Комментарии

        Used when observation has a set of component observations:

        • An observation may have both a value (e.g. an Apgar score) and component observations (the observations from which the Apgar score was derived).
        • If a value is present, the datatype for this element should be determined by the code.
        • CodeableConcept with just a text would be used instead of a string if the field was usually coded, or if the type associated with the code defines a coded value.
        • Attachment is used if the observation result value is a binary file such as an image. If the observation result value is derived from the binary file (for example 'X' detected and here is the the proof in this image), the binary file may be directly represented using DocumentReference and referenced by derivedFrom.
        • If a value is present, the datatype for this element should be determined by the code.
        • CodeableConcept with just a text would be used instead of a string if the field was usually coded, or if the type associated with the code defines a coded value.
        • Attachment is used if the observation result value is a binary file such as an image. If the observation result value is derived from the binary file (for example 'X' detected and here is the the proof in this image), the binary file may be directly represented using DocumentReference and referenced by derivedFrom.
        • The usage of valueReference is restricted to the MolecularSequence resource when used as a definitional resource, not as a patient-specific finding. .
        • For additional guidance, see the Notes section below.
        Контроль10..1
        Типstring, dateTime, Reference(MolecularSequence), Quantity, Period, Attachment, integer, Range, boolean, SampledData, Ratio, time, CodeableConcept
        [x] ЗаметкаСмотретьВыбор типов данныхдля дополнительной информации о том, как использовать [x]
        Модификаторfalse
        Примитивное значениеЭтот примитивный элемент может присутствовать или отсутствовать, или быть замененным расширением
        Требуется поддержкаtrue
        Summarytrue
        Требования

        An observation exists to have a value, though it might not if it is in error, or if it represents a group of observations.

        Инвариантыele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
        ele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
        317. Observation.component:fibroglandularThickness
        Название разрезаfibroglandularThickness
        Определение

        Some observations have multiple component observations. These component observations are expressed as separate code value pairs that share the same attributes. Examples include systolic and diastolic component observations for blood pressure measurement and multiple component observations for genetics observations.

        КороткийFibroglandular complex thicknessComponent results
        Комментарии

        For a discussion on the ways Observations can be assembled in groups together see Notes below.

        Контроль0..1*
        На этот элемент влияют следующие инварианты: obs-7
        ТипBackboneElement
        Модификаторfalse
        Требуется поддержкаtrue
        Summarytrue
        Требования

        Component observations share the same attributes in the Observation resource as the primary observation and are always treated a part of a single observation (they are not separable). However, the reference range for the primary observation value is not inherited by the component values and is required when appropriate for each component observation.

        Инвариантыele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
        ele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
        319. Observation.component:fibroglandularThickness.modifierExtension
        Определение

        May be used to represent additional information that is not part of the basic definition of the element and that modifies the understanding of the element in which it is contained and/or the understanding of the containing element's descendants. Usually modifier elements provide negation or qualification. To make the use of extensions safe and managable, there is a strict set of governance applied to the definition and use of extensions. Though any implementer can define an extension, there is a set of requirements that SHALL be met as part of the definition of the extension. Applications processing a resource are required to check for modifier extensions.

        Modifier extensions SHALL NOT change the meaning of any elements on Resource or DomainResource (including cannot change the meaning of modifierExtension itself).

        КороткийExtensions that cannot be ignored even if unrecognized
        Комментарии

        There can be no stigma associated with the use of extensions by any application, project, or standard - regardless of the institution or jurisdiction that uses or defines the extensions. The use of extensions is what allows the FHIR specification to retain a core level of simplicity for everyone.

        Контроль0..*
        ТипExtension
        Модификаторtrue потому что Modifier extensions are expected to modify the meaning or interpretation of the element that contains them
        Summarytrue
        Требования

        Modifier extensions allow for extensions that cannot be safely ignored to be clearly distinguished from the vast majority of extensions which can be safely ignored. This promotes interoperability by eliminating the need for implementers to prohibit the presence of extensions. For further information, see the definition of modifier extensions.

        Альтернативные именаextensions, user content, modifiers
        Инвариантыele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
        ext-1: Must have either extensions or value[x], not both (extension.exists() != value.exists())
        ele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
        ext-1: Must have either extensions or value[x], not both (extension.exists() != value.exists())
        321. Observation.component:fibroglandularThickness.code
        Определение

        Describes what was observed. Sometimes this is called the observation "code".

        КороткийType of component observation (code / type)
        Комментарии

        All code-value and component.code-component.value pairs need to be taken into account to correctly understand the meaning of the observation.

        Контроль1..1
        На этот элемент влияют следующие инварианты: obs-7
        ПривязкаКоды СЛЕДУЕТ взять из Например, коды см. ObservationCodesVS (0.12.0)http://hl7.org/fhir/ValueSet/observation-codes|5.0.0
        (preferred to https://terminology.dhp.uz/fhir/core/ValueSet/observation-codes-vs|0.12.0)
        ТипCodeableConcept
        Модификаторfalse
        Требуется поддержкаtrue
        Summarytrue
        Требования

        Knowing what kind of observation is being made is essential to understanding the observation.

        Значение шаблона{
          "coding" : [{
            "system" : "https://terminology.dhp.uz/fhir/integrations/CodeSystem/screening-ultrasound-parameter-cs",
            "code" : "scrn-0052-00009"
          }]
        }
        Инвариантыele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
        ele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
        323. Observation.component:fibroglandularThickness.value[x]
        Определение

        The information determined as a result of making the observation, if the information has a simple value.

        КороткийActual component result
        Комментарии

        Used when observation has a set of component observations:

        • An observation may have both a value (e.g. an Apgar score) and component observations (the observations from which the Apgar score was derived).
        • If a value is present, the datatype for this element should be determined by the code.
        • CodeableConcept with just a text would be used instead of a string if the field was usually coded, or if the type associated with the code defines a coded value.
        • Attachment is used if the observation result value is a binary file such as an image. If the observation result value is derived from the binary file (for example 'X' detected and here is the the proof in this image), the binary file may be directly represented using DocumentReference and referenced by derivedFrom.
        • If a value is present, the datatype for this element should be determined by the code.
        • CodeableConcept with just a text would be used instead of a string if the field was usually coded, or if the type associated with the code defines a coded value.
        • Attachment is used if the observation result value is a binary file such as an image. If the observation result value is derived from the binary file (for example 'X' detected and here is the the proof in this image), the binary file may be directly represented using DocumentReference and referenced by derivedFrom.
        • The usage of valueReference is restricted to the MolecularSequence resource when used as a definitional resource, not as a patient-specific finding. .
        • For additional guidance, see the Notes section below.
        Контроль10..1
        ТипQuantity, dateTime, string, Reference(MolecularSequence), Period, Attachment, integer, Range, boolean, SampledData, Ratio, time, CodeableConcept
        [x] ЗаметкаСмотретьВыбор типов данныхдля дополнительной информации о том, как использовать [x]
        Модификаторfalse
        Требуется поддержкаtrue
        Summarytrue
        Требования

        An observation exists to have a value, though it might not if it is in error, or if it represents a group of observations.

        Значение шаблона{
          "unit" : "mm",
          "system" : "http://unitsofmeasure.org",
          "code" : "mm"
        }
        Инвариантыele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
        ele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
        325. Observation.component:fibroglandularThickness.value[x].value
        Определение

        The value of the measured amount. The value includes an implicit precision in the presentation of the value.

        КороткийNumerical value (with implicit precision)
        Комментарии

        The implicit precision in the value should always be honored. Monetary values have their own rules for handling precision (refer to standard accounting text books).

        Контроль10..1
        Типdecimal
        Модификаторfalse
        Примитивное значениеЭтот примитивный элемент может присутствовать или отсутствовать, или быть замененным расширением
        Summarytrue
        Требования

        Precision is handled implicitly in almost all cases of measurement.

        Мин. значение0
        Инвариантыele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
        ele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
        327. Observation.component:fibroglandularThickness.value[x].comparator
        Определение

        How the value should be understood and represented - whether the actual value is greater or less than the stated value due to measurement issues; e.g. if the comparator is "<" , then the real value is < stated value.

        Короткий< | <= | >= | > | ad - how to understand the value
        Контроль0..1
        ПривязкаКоды ДОЛЖНЫ быть взяты из QuantityComparatorhttp://hl7.org/fhir/ValueSet/quantity-comparator|5.0.0
        (required to http://hl7.org/fhir/ValueSet/quantity-comparator|5.0.0)

        How the Quantity should be understood and represented.

        Типcode
        Модификаторtrue потому что This is labeled as "Is Modifier" because the comparator modifies the interpretation of the value significantly. If there is no comparator, then there is no modification of the value
        Примитивное значениеЭтот примитивный элемент может присутствовать или отсутствовать, или быть замененным расширением
        Summarytrue
        Требования

        Need a framework for handling measures where the value is <5ug/L or >400mg/L due to the limitations of measuring methodology.

        Значение при отсутствииIf there is no comparator, then there is no modification of the value
        Инвариантыele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
        ele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
        329. Observation.component:fibroglandularThickness.value[x].unit
        Определение

        A human-readable form of the unit.

        КороткийUnit representation
        Контроль10..1
        Типstring
        Модификаторfalse
        Примитивное значениеЭтот примитивный элемент может присутствовать или отсутствовать, или быть замененным расширением
        Summarytrue
        Требования

        There are many representations for units of measure and in many contexts, particular representations are fixed and required. I.e. mcg for micrograms.

        Инвариантыele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
        ele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
        331. Observation.component:fibroglandularThickness.value[x].system
        Определение

        The identification of the system that provides the coded form of the unit.

        КороткийSystem that defines coded unit form
        Контроль10..1
        На этот элемент влияют следующие инварианты: qty-3
        Типuri
        Модификаторfalse
        Примитивное значениеЭтот примитивный элемент может присутствовать или отсутствовать, или быть замененным расширением
        Summarytrue
        Требования

        Need to know the system that defines the coded form of the unit.

        Инвариантыele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
        ele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
        333. Observation.component:fibroglandularThickness.value[x].code
        Определение

        A computer processable form of the unit in some unit representation system.

        КороткийCoded form of the unit
        Комментарии

        The preferred system is UCUM, but SNOMED CT can also be used (for customary units) or ISO 4217 for currency. The context of use may additionally require a code from a particular system.

        Контроль10..1
        На этот элемент влияют следующие инварианты: qty-3
        Типcode
        Модификаторfalse
        Примитивное значениеЭтот примитивный элемент может присутствовать или отсутствовать, или быть замененным расширением
        Summarytrue
        Требования

        Need a computable form of the unit that is fixed across all forms. UCUM provides this for quantities, but SNOMED CT provides many units of interest.

        Инвариантыele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
        ele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
        335. Observation.component:maximumDuctDiameter
        Название разрезаmaximumDuctDiameter
        Определение

        Some observations have multiple component observations. These component observations are expressed as separate code value pairs that share the same attributes. Examples include systolic and diastolic component observations for blood pressure measurement and multiple component observations for genetics observations.

        КороткийMaximum duct diameterComponent results
        Комментарии

        For a discussion on the ways Observations can be assembled in groups together see Notes below.

        Контроль0..1*
        На этот элемент влияют следующие инварианты: obs-7
        ТипBackboneElement
        Модификаторfalse
        Требуется поддержкаtrue
        Summarytrue
        Требования

        Component observations share the same attributes in the Observation resource as the primary observation and are always treated a part of a single observation (they are not separable). However, the reference range for the primary observation value is not inherited by the component values and is required when appropriate for each component observation.

        Инвариантыele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
        ele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
        337. Observation.component:maximumDuctDiameter.modifierExtension
        Определение

        May be used to represent additional information that is not part of the basic definition of the element and that modifies the understanding of the element in which it is contained and/or the understanding of the containing element's descendants. Usually modifier elements provide negation or qualification. To make the use of extensions safe and managable, there is a strict set of governance applied to the definition and use of extensions. Though any implementer can define an extension, there is a set of requirements that SHALL be met as part of the definition of the extension. Applications processing a resource are required to check for modifier extensions.

        Modifier extensions SHALL NOT change the meaning of any elements on Resource or DomainResource (including cannot change the meaning of modifierExtension itself).

        КороткийExtensions that cannot be ignored even if unrecognized
        Комментарии

        There can be no stigma associated with the use of extensions by any application, project, or standard - regardless of the institution or jurisdiction that uses or defines the extensions. The use of extensions is what allows the FHIR specification to retain a core level of simplicity for everyone.

        Контроль0..*
        ТипExtension
        Модификаторtrue потому что Modifier extensions are expected to modify the meaning or interpretation of the element that contains them
        Summarytrue
        Требования

        Modifier extensions allow for extensions that cannot be safely ignored to be clearly distinguished from the vast majority of extensions which can be safely ignored. This promotes interoperability by eliminating the need for implementers to prohibit the presence of extensions. For further information, see the definition of modifier extensions.

        Альтернативные именаextensions, user content, modifiers
        Инвариантыele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
        ext-1: Must have either extensions or value[x], not both (extension.exists() != value.exists())
        ele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
        ext-1: Must have either extensions or value[x], not both (extension.exists() != value.exists())
        339. Observation.component:maximumDuctDiameter.code
        Определение

        Describes what was observed. Sometimes this is called the observation "code".

        КороткийType of component observation (code / type)
        Комментарии

        All code-value and component.code-component.value pairs need to be taken into account to correctly understand the meaning of the observation.

        Контроль1..1
        На этот элемент влияют следующие инварианты: obs-7
        ПривязкаКоды СЛЕДУЕТ взять из Например, коды см. ObservationCodesVS (0.12.0)http://hl7.org/fhir/ValueSet/observation-codes|5.0.0
        (preferred to https://terminology.dhp.uz/fhir/core/ValueSet/observation-codes-vs|0.12.0)
        ТипCodeableConcept
        Модификаторfalse
        Требуется поддержкаtrue
        Summarytrue
        Требования

        Knowing what kind of observation is being made is essential to understanding the observation.

        Значение шаблона{
          "coding" : [{
            "system" : "https://terminology.dhp.uz/fhir/integrations/CodeSystem/screening-ultrasound-parameter-cs",
            "code" : "scrn-0052-00011"
          }]
        }
        Инвариантыele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
        ele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
        341. Observation.component:maximumDuctDiameter.value[x]
        Определение

        The information determined as a result of making the observation, if the information has a simple value.

        КороткийActual component result
        Комментарии

        Used when observation has a set of component observations:

        • An observation may have both a value (e.g. an Apgar score) and component observations (the observations from which the Apgar score was derived).
        • If a value is present, the datatype for this element should be determined by the code.
        • CodeableConcept with just a text would be used instead of a string if the field was usually coded, or if the type associated with the code defines a coded value.
        • Attachment is used if the observation result value is a binary file such as an image. If the observation result value is derived from the binary file (for example 'X' detected and here is the the proof in this image), the binary file may be directly represented using DocumentReference and referenced by derivedFrom.
        • If a value is present, the datatype for this element should be determined by the code.
        • CodeableConcept with just a text would be used instead of a string if the field was usually coded, or if the type associated with the code defines a coded value.
        • Attachment is used if the observation result value is a binary file such as an image. If the observation result value is derived from the binary file (for example 'X' detected and here is the the proof in this image), the binary file may be directly represented using DocumentReference and referenced by derivedFrom.
        • The usage of valueReference is restricted to the MolecularSequence resource when used as a definitional resource, not as a patient-specific finding. .
        • For additional guidance, see the Notes section below.
        Контроль10..1
        ТипQuantity, dateTime, string, Reference(MolecularSequence), Period, Attachment, integer, Range, boolean, SampledData, Ratio, time, CodeableConcept
        [x] ЗаметкаСмотретьВыбор типов данныхдля дополнительной информации о том, как использовать [x]
        Модификаторfalse
        Требуется поддержкаtrue
        Summarytrue
        Требования

        An observation exists to have a value, though it might not if it is in error, or if it represents a group of observations.

        Значение шаблона{
          "unit" : "mm",
          "system" : "http://unitsofmeasure.org",
          "code" : "mm"
        }
        Инвариантыele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
        ele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
        343. Observation.component:maximumDuctDiameter.value[x].value
        Определение

        The value of the measured amount. The value includes an implicit precision in the presentation of the value.

        КороткийNumerical value (with implicit precision)
        Комментарии

        The implicit precision in the value should always be honored. Monetary values have their own rules for handling precision (refer to standard accounting text books).

        Контроль10..1
        Типdecimal
        Модификаторfalse
        Примитивное значениеЭтот примитивный элемент может присутствовать или отсутствовать, или быть замененным расширением
        Summarytrue
        Требования

        Precision is handled implicitly in almost all cases of measurement.

        Мин. значение0
        Инвариантыele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
        ele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
        345. Observation.component:maximumDuctDiameter.value[x].comparator
        Определение

        How the value should be understood and represented - whether the actual value is greater or less than the stated value due to measurement issues; e.g. if the comparator is "<" , then the real value is < stated value.

        Короткий< | <= | >= | > | ad - how to understand the value
        Контроль0..1
        ПривязкаКоды ДОЛЖНЫ быть взяты из QuantityComparatorhttp://hl7.org/fhir/ValueSet/quantity-comparator|5.0.0
        (required to http://hl7.org/fhir/ValueSet/quantity-comparator|5.0.0)

        How the Quantity should be understood and represented.

        Типcode
        Модификаторtrue потому что This is labeled as "Is Modifier" because the comparator modifies the interpretation of the value significantly. If there is no comparator, then there is no modification of the value
        Примитивное значениеЭтот примитивный элемент может присутствовать или отсутствовать, или быть замененным расширением
        Summarytrue
        Требования

        Need a framework for handling measures where the value is <5ug/L or >400mg/L due to the limitations of measuring methodology.

        Значение при отсутствииIf there is no comparator, then there is no modification of the value
        Инвариантыele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
        ele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
        347. Observation.component:maximumDuctDiameter.value[x].unit
        Определение

        A human-readable form of the unit.

        КороткийUnit representation
        Контроль10..1
        Типstring
        Модификаторfalse
        Примитивное значениеЭтот примитивный элемент может присутствовать или отсутствовать, или быть замененным расширением
        Summarytrue
        Требования

        There are many representations for units of measure and in many contexts, particular representations are fixed and required. I.e. mcg for micrograms.

        Инвариантыele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
        ele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
        349. Observation.component:maximumDuctDiameter.value[x].system
        Определение

        The identification of the system that provides the coded form of the unit.

        КороткийSystem that defines coded unit form
        Контроль10..1
        На этот элемент влияют следующие инварианты: qty-3
        Типuri
        Модификаторfalse
        Примитивное значениеЭтот примитивный элемент может присутствовать или отсутствовать, или быть замененным расширением
        Summarytrue
        Требования

        Need to know the system that defines the coded form of the unit.

        Инвариантыele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
        ele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
        351. Observation.component:maximumDuctDiameter.value[x].code
        Определение

        A computer processable form of the unit in some unit representation system.

        КороткийCoded form of the unit
        Комментарии

        The preferred system is UCUM, but SNOMED CT can also be used (for customary units) or ISO 4217 for currency. The context of use may additionally require a code from a particular system.

        Контроль10..1
        На этот элемент влияют следующие инварианты: qty-3
        Типcode
        Модификаторfalse
        Примитивное значениеЭтот примитивный элемент может присутствовать или отсутствовать, или быть замененным расширением
        Summarytrue
        Требования

        Need a computable form of the unit that is fixed across all forms. UCUM provides this for quantities, but SNOMED CT provides many units of interest.

        Инвариантыele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
        ele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
        353. Observation.component:elastographyStiffness
        Название разрезаelastographyStiffness
        Определение

        Some observations have multiple component observations. These component observations are expressed as separate code value pairs that share the same attributes. Examples include systolic and diastolic component observations for blood pressure measurement and multiple component observations for genetics observations.

        КороткийElastography stiffness; unit is supplied by ScreeningComponent results
        Комментарии

        For a discussion on the ways Observations can be assembled in groups together see Notes below.

        Контроль0..1*
        На этот элемент влияют следующие инварианты: obs-7
        ТипBackboneElement
        Модификаторfalse
        Требуется поддержкаtrue
        Summarytrue
        Требования

        Component observations share the same attributes in the Observation resource as the primary observation and are always treated a part of a single observation (they are not separable). However, the reference range for the primary observation value is not inherited by the component values and is required when appropriate for each component observation.

        Инвариантыele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
        ele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
        355. Observation.component:elastographyStiffness.modifierExtension
        Определение

        May be used to represent additional information that is not part of the basic definition of the element and that modifies the understanding of the element in which it is contained and/or the understanding of the containing element's descendants. Usually modifier elements provide negation or qualification. To make the use of extensions safe and managable, there is a strict set of governance applied to the definition and use of extensions. Though any implementer can define an extension, there is a set of requirements that SHALL be met as part of the definition of the extension. Applications processing a resource are required to check for modifier extensions.

        Modifier extensions SHALL NOT change the meaning of any elements on Resource or DomainResource (including cannot change the meaning of modifierExtension itself).

        КороткийExtensions that cannot be ignored even if unrecognized
        Комментарии

        There can be no stigma associated with the use of extensions by any application, project, or standard - regardless of the institution or jurisdiction that uses or defines the extensions. The use of extensions is what allows the FHIR specification to retain a core level of simplicity for everyone.

        Контроль0..*
        ТипExtension
        Модификаторtrue потому что Modifier extensions are expected to modify the meaning or interpretation of the element that contains them
        Summarytrue
        Требования

        Modifier extensions allow for extensions that cannot be safely ignored to be clearly distinguished from the vast majority of extensions which can be safely ignored. This promotes interoperability by eliminating the need for implementers to prohibit the presence of extensions. For further information, see the definition of modifier extensions.

        Альтернативные именаextensions, user content, modifiers
        Инвариантыele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
        ext-1: Must have either extensions or value[x], not both (extension.exists() != value.exists())
        ele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
        ext-1: Must have either extensions or value[x], not both (extension.exists() != value.exists())
        357. Observation.component:elastographyStiffness.code
        Определение

        Describes what was observed. Sometimes this is called the observation "code".

        КороткийType of component observation (code / type)
        Комментарии

        All code-value and component.code-component.value pairs need to be taken into account to correctly understand the meaning of the observation.

        Контроль1..1
        На этот элемент влияют следующие инварианты: obs-7
        ПривязкаКоды СЛЕДУЕТ взять из Например, коды см. ObservationCodesVS (0.12.0)http://hl7.org/fhir/ValueSet/observation-codes|5.0.0
        (preferred to https://terminology.dhp.uz/fhir/core/ValueSet/observation-codes-vs|0.12.0)
        ТипCodeableConcept
        Модификаторfalse
        Требуется поддержкаtrue
        Summarytrue
        Требования

        Knowing what kind of observation is being made is essential to understanding the observation.

        Значение шаблона{
          "coding" : [{
            "system" : "https://terminology.dhp.uz/fhir/integrations/CodeSystem/screening-ultrasound-parameter-cs",
            "code" : "scrn-0052-00014"
          }]
        }
        Инвариантыele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
        ele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
        359. Observation.component:elastographyStiffness.value[x]
        Определение

        The information determined as a result of making the observation, if the information has a simple value.

        КороткийActual component result
        Комментарии

        Used when observation has a set of component observations:

        • An observation may have both a value (e.g. an Apgar score) and component observations (the observations from which the Apgar score was derived).
        • If a value is present, the datatype for this element should be determined by the code.
        • CodeableConcept with just a text would be used instead of a string if the field was usually coded, or if the type associated with the code defines a coded value.
        • Attachment is used if the observation result value is a binary file such as an image. If the observation result value is derived from the binary file (for example 'X' detected and here is the the proof in this image), the binary file may be directly represented using DocumentReference and referenced by derivedFrom.
        • If a value is present, the datatype for this element should be determined by the code.
        • CodeableConcept with just a text would be used instead of a string if the field was usually coded, or if the type associated with the code defines a coded value.
        • Attachment is used if the observation result value is a binary file such as an image. If the observation result value is derived from the binary file (for example 'X' detected and here is the the proof in this image), the binary file may be directly represented using DocumentReference and referenced by derivedFrom.
        • The usage of valueReference is restricted to the MolecularSequence resource when used as a definitional resource, not as a patient-specific finding. .
        • For additional guidance, see the Notes section below.
        Контроль10..1
        ТипQuantity, dateTime, string, Reference(MolecularSequence), Period, Attachment, integer, Range, boolean, SampledData, Ratio, time, CodeableConcept
        [x] ЗаметкаСмотретьВыбор типов данныхдля дополнительной информации о том, как использовать [x]
        Модификаторfalse
        Требуется поддержкаtrue
        Summarytrue
        Требования

        An observation exists to have a value, though it might not if it is in error, or if it represents a group of observations.

        Значение шаблона{
          "system" : "http://unitsofmeasure.org"
        }
        Инвариантыele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
        ele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
        361. Observation.component:elastographyStiffness.value[x].value
        Определение

        The value of the measured amount. The value includes an implicit precision in the presentation of the value.

        КороткийNumerical value (with implicit precision)
        Комментарии

        The implicit precision in the value should always be honored. Monetary values have their own rules for handling precision (refer to standard accounting text books).

        Контроль10..1
        Типdecimal
        Модификаторfalse
        Примитивное значениеЭтот примитивный элемент может присутствовать или отсутствовать, или быть замененным расширением
        Summarytrue
        Требования

        Precision is handled implicitly in almost all cases of measurement.

        Мин. значение0
        Инвариантыele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
        ele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
        363. Observation.component:elastographyStiffness.value[x].comparator
        Определение

        How the value should be understood and represented - whether the actual value is greater or less than the stated value due to measurement issues; e.g. if the comparator is "<" , then the real value is < stated value.

        Короткий< | <= | >= | > | ad - how to understand the value
        Контроль0..1
        ПривязкаКоды ДОЛЖНЫ быть взяты из QuantityComparatorhttp://hl7.org/fhir/ValueSet/quantity-comparator|5.0.0
        (required to http://hl7.org/fhir/ValueSet/quantity-comparator|5.0.0)

        How the Quantity should be understood and represented.

        Типcode
        Модификаторtrue потому что This is labeled as "Is Modifier" because the comparator modifies the interpretation of the value significantly. If there is no comparator, then there is no modification of the value
        Примитивное значениеЭтот примитивный элемент может присутствовать или отсутствовать, или быть замененным расширением
        Summarytrue
        Требования

        Need a framework for handling measures where the value is <5ug/L or >400mg/L due to the limitations of measuring methodology.

        Значение при отсутствииIf there is no comparator, then there is no modification of the value
        Инвариантыele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
        ele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
        365. Observation.component:elastographyStiffness.value[x].unit
        Определение

        A human-readable form of the unit.

        КороткийUnit representation
        Контроль10..1
        Типstring
        Модификаторfalse
        Примитивное значениеЭтот примитивный элемент может присутствовать или отсутствовать, или быть замененным расширением
        Summarytrue
        Требования

        There are many representations for units of measure and in many contexts, particular representations are fixed and required. I.e. mcg for micrograms.

        Инвариантыele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
        ele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
        367. Observation.component:elastographyStiffness.value[x].system
        Определение

        The identification of the system that provides the coded form of the unit.

        КороткийSystem that defines coded unit form
        Контроль10..1
        На этот элемент влияют следующие инварианты: qty-3
        Типuri
        Модификаторfalse
        Примитивное значениеЭтот примитивный элемент может присутствовать или отсутствовать, или быть замененным расширением
        Summarytrue
        Требования

        Need to know the system that defines the coded form of the unit.

        Инвариантыele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
        ele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
        369. Observation.component:elastographyStiffness.value[x].code
        Определение

        A computer processable form of the unit in some unit representation system.

        КороткийCoded form of the unit
        Комментарии

        The preferred system is UCUM, but SNOMED CT can also be used (for customary units) or ISO 4217 for currency. The context of use may additionally require a code from a particular system.

        Контроль10..1
        На этот элемент влияют следующие инварианты: qty-3
        Типcode
        Модификаторfalse
        Примитивное значениеЭтот примитивный элемент может присутствовать или отсутствовать, или быть замененным расширением
        Summarytrue
        Требования

        Need a computable form of the unit that is fixed across all forms. UCUM provides this for quantities, but SNOMED CT provides many units of interest.

        Инвариантыele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
        ele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
        371. Observation.component:axillaryMaximumNodeSize
        Название разрезаaxillaryMaximumNodeSize
        Определение

        Some observations have multiple component observations. These component observations are expressed as separate code value pairs that share the same attributes. Examples include systolic and diastolic component observations for blood pressure measurement and multiple component observations for genetics observations.

        КороткийMaximum axillary lymph node sizeComponent results
        Комментарии

        For a discussion on the ways Observations can be assembled in groups together see Notes below.

        Контроль0..1*
        На этот элемент влияют следующие инварианты: obs-7
        ТипBackboneElement
        Модификаторfalse
        Требуется поддержкаtrue
        Summarytrue
        Требования

        Component observations share the same attributes in the Observation resource as the primary observation and are always treated a part of a single observation (they are not separable). However, the reference range for the primary observation value is not inherited by the component values and is required when appropriate for each component observation.

        Инвариантыele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
        ele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
        373. Observation.component:axillaryMaximumNodeSize.modifierExtension
        Определение

        May be used to represent additional information that is not part of the basic definition of the element and that modifies the understanding of the element in which it is contained and/or the understanding of the containing element's descendants. Usually modifier elements provide negation or qualification. To make the use of extensions safe and managable, there is a strict set of governance applied to the definition and use of extensions. Though any implementer can define an extension, there is a set of requirements that SHALL be met as part of the definition of the extension. Applications processing a resource are required to check for modifier extensions.

        Modifier extensions SHALL NOT change the meaning of any elements on Resource or DomainResource (including cannot change the meaning of modifierExtension itself).

        КороткийExtensions that cannot be ignored even if unrecognized
        Комментарии

        There can be no stigma associated with the use of extensions by any application, project, or standard - regardless of the institution or jurisdiction that uses or defines the extensions. The use of extensions is what allows the FHIR specification to retain a core level of simplicity for everyone.

        Контроль0..*
        ТипExtension
        Модификаторtrue потому что Modifier extensions are expected to modify the meaning or interpretation of the element that contains them
        Summarytrue
        Требования

        Modifier extensions allow for extensions that cannot be safely ignored to be clearly distinguished from the vast majority of extensions which can be safely ignored. This promotes interoperability by eliminating the need for implementers to prohibit the presence of extensions. For further information, see the definition of modifier extensions.

        Альтернативные именаextensions, user content, modifiers
        Инвариантыele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
        ext-1: Must have either extensions or value[x], not both (extension.exists() != value.exists())
        ele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
        ext-1: Must have either extensions or value[x], not both (extension.exists() != value.exists())
        375. Observation.component:axillaryMaximumNodeSize.code
        Определение

        Describes what was observed. Sometimes this is called the observation "code".

        КороткийType of component observation (code / type)
        Комментарии

        All code-value and component.code-component.value pairs need to be taken into account to correctly understand the meaning of the observation.

        Контроль1..1
        На этот элемент влияют следующие инварианты: obs-7
        ПривязкаКоды СЛЕДУЕТ взять из Например, коды см. ObservationCodesVS (0.12.0)http://hl7.org/fhir/ValueSet/observation-codes|5.0.0
        (preferred to https://terminology.dhp.uz/fhir/core/ValueSet/observation-codes-vs|0.12.0)
        ТипCodeableConcept
        Модификаторfalse
        Требуется поддержкаtrue
        Summarytrue
        Требования

        Knowing what kind of observation is being made is essential to understanding the observation.

        Значение шаблона{
          "coding" : [{
            "system" : "https://terminology.dhp.uz/fhir/integrations/CodeSystem/screening-ultrasound-parameter-cs",
            "code" : "scrn-0052-00038"
          }]
        }
        Инвариантыele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
        ele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
        377. Observation.component:axillaryMaximumNodeSize.value[x]
        Определение

        The information determined as a result of making the observation, if the information has a simple value.

        КороткийActual component result
        Комментарии

        Used when observation has a set of component observations:

        • An observation may have both a value (e.g. an Apgar score) and component observations (the observations from which the Apgar score was derived).
        • If a value is present, the datatype for this element should be determined by the code.
        • CodeableConcept with just a text would be used instead of a string if the field was usually coded, or if the type associated with the code defines a coded value.
        • Attachment is used if the observation result value is a binary file such as an image. If the observation result value is derived from the binary file (for example 'X' detected and here is the the proof in this image), the binary file may be directly represented using DocumentReference and referenced by derivedFrom.
        • If a value is present, the datatype for this element should be determined by the code.
        • CodeableConcept with just a text would be used instead of a string if the field was usually coded, or if the type associated with the code defines a coded value.
        • Attachment is used if the observation result value is a binary file such as an image. If the observation result value is derived from the binary file (for example 'X' detected and here is the the proof in this image), the binary file may be directly represented using DocumentReference and referenced by derivedFrom.
        • The usage of valueReference is restricted to the MolecularSequence resource when used as a definitional resource, not as a patient-specific finding. .
        • For additional guidance, see the Notes section below.
        Контроль10..1
        ТипQuantity, dateTime, string, Reference(MolecularSequence), Period, Attachment, integer, Range, boolean, SampledData, Ratio, time, CodeableConcept
        [x] ЗаметкаСмотретьВыбор типов данныхдля дополнительной информации о том, как использовать [x]
        Модификаторfalse
        Требуется поддержкаtrue
        Summarytrue
        Требования

        An observation exists to have a value, though it might not if it is in error, or if it represents a group of observations.

        Значение шаблона{
          "unit" : "mm",
          "system" : "http://unitsofmeasure.org",
          "code" : "mm"
        }
        Инвариантыele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
        ele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
        379. Observation.component:axillaryMaximumNodeSize.value[x].value
        Определение

        The value of the measured amount. The value includes an implicit precision in the presentation of the value.

        КороткийNumerical value (with implicit precision)
        Комментарии

        The implicit precision in the value should always be honored. Monetary values have their own rules for handling precision (refer to standard accounting text books).

        Контроль10..1
        Типdecimal
        Модификаторfalse
        Примитивное значениеЭтот примитивный элемент может присутствовать или отсутствовать, или быть замененным расширением
        Summarytrue
        Требования

        Precision is handled implicitly in almost all cases of measurement.

        Мин. значение0
        Инвариантыele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
        ele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
        381. Observation.component:axillaryMaximumNodeSize.value[x].comparator
        Определение

        How the value should be understood and represented - whether the actual value is greater or less than the stated value due to measurement issues; e.g. if the comparator is "<" , then the real value is < stated value.

        Короткий< | <= | >= | > | ad - how to understand the value
        Контроль0..1
        ПривязкаКоды ДОЛЖНЫ быть взяты из QuantityComparatorhttp://hl7.org/fhir/ValueSet/quantity-comparator|5.0.0
        (required to http://hl7.org/fhir/ValueSet/quantity-comparator|5.0.0)

        How the Quantity should be understood and represented.

        Типcode
        Модификаторtrue потому что This is labeled as "Is Modifier" because the comparator modifies the interpretation of the value significantly. If there is no comparator, then there is no modification of the value
        Примитивное значениеЭтот примитивный элемент может присутствовать или отсутствовать, или быть замененным расширением
        Summarytrue
        Требования

        Need a framework for handling measures where the value is <5ug/L or >400mg/L due to the limitations of measuring methodology.

        Значение при отсутствииIf there is no comparator, then there is no modification of the value
        Инвариантыele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
        ele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
        383. Observation.component:axillaryMaximumNodeSize.value[x].unit
        Определение

        A human-readable form of the unit.

        КороткийUnit representation
        Контроль10..1
        Типstring
        Модификаторfalse
        Примитивное значениеЭтот примитивный элемент может присутствовать или отсутствовать, или быть замененным расширением
        Summarytrue
        Требования

        There are many representations for units of measure and in many contexts, particular representations are fixed and required. I.e. mcg for micrograms.

        Инвариантыele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
        ele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
        385. Observation.component:axillaryMaximumNodeSize.value[x].system
        Определение

        The identification of the system that provides the coded form of the unit.

        КороткийSystem that defines coded unit form
        Контроль10..1
        На этот элемент влияют следующие инварианты: qty-3
        Типuri
        Модификаторfalse
        Примитивное значениеЭтот примитивный элемент может присутствовать или отсутствовать, или быть замененным расширением
        Summarytrue
        Требования

        Need to know the system that defines the coded form of the unit.

        Инвариантыele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
        ele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
        387. Observation.component:axillaryMaximumNodeSize.value[x].code
        Определение

        A computer processable form of the unit in some unit representation system.

        КороткийCoded form of the unit
        Комментарии

        The preferred system is UCUM, but SNOMED CT can also be used (for customary units) or ISO 4217 for currency. The context of use may additionally require a code from a particular system.

        Контроль10..1
        На этот элемент влияют следующие инварианты: qty-3
        Типcode
        Модификаторfalse
        Примитивное значениеЭтот примитивный элемент может присутствовать или отсутствовать, или быть замененным расширением
        Summarytrue
        Требования

        Need a computable form of the unit that is fixed across all forms. UCUM provides this for quantities, but SNOMED CT provides many units of interest.

        Инвариантыele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
        ele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
        389. Observation.component:axillaryCorticalThickness
        Название разрезаaxillaryCorticalThickness
        Определение

        Some observations have multiple component observations. These component observations are expressed as separate code value pairs that share the same attributes. Examples include systolic and diastolic component observations for blood pressure measurement and multiple component observations for genetics observations.

        КороткийAxillary lymph node cortical thicknessComponent results
        Комментарии

        For a discussion on the ways Observations can be assembled in groups together see Notes below.

        Контроль0..1*
        На этот элемент влияют следующие инварианты: obs-7
        ТипBackboneElement
        Модификаторfalse
        Требуется поддержкаtrue
        Summarytrue
        Требования

        Component observations share the same attributes in the Observation resource as the primary observation and are always treated a part of a single observation (they are not separable). However, the reference range for the primary observation value is not inherited by the component values and is required when appropriate for each component observation.

        Инвариантыele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
        ele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
        391. Observation.component:axillaryCorticalThickness.modifierExtension
        Определение

        May be used to represent additional information that is not part of the basic definition of the element and that modifies the understanding of the element in which it is contained and/or the understanding of the containing element's descendants. Usually modifier elements provide negation or qualification. To make the use of extensions safe and managable, there is a strict set of governance applied to the definition and use of extensions. Though any implementer can define an extension, there is a set of requirements that SHALL be met as part of the definition of the extension. Applications processing a resource are required to check for modifier extensions.

        Modifier extensions SHALL NOT change the meaning of any elements on Resource or DomainResource (including cannot change the meaning of modifierExtension itself).

        КороткийExtensions that cannot be ignored even if unrecognized
        Комментарии

        There can be no stigma associated with the use of extensions by any application, project, or standard - regardless of the institution or jurisdiction that uses or defines the extensions. The use of extensions is what allows the FHIR specification to retain a core level of simplicity for everyone.

        Контроль0..*
        ТипExtension
        Модификаторtrue потому что Modifier extensions are expected to modify the meaning or interpretation of the element that contains them
        Summarytrue
        Требования

        Modifier extensions allow for extensions that cannot be safely ignored to be clearly distinguished from the vast majority of extensions which can be safely ignored. This promotes interoperability by eliminating the need for implementers to prohibit the presence of extensions. For further information, see the definition of modifier extensions.

        Альтернативные именаextensions, user content, modifiers
        Инвариантыele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
        ext-1: Must have either extensions or value[x], not both (extension.exists() != value.exists())
        ele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
        ext-1: Must have either extensions or value[x], not both (extension.exists() != value.exists())
        393. Observation.component:axillaryCorticalThickness.code
        Определение

        Describes what was observed. Sometimes this is called the observation "code".

        КороткийType of component observation (code / type)
        Комментарии

        All code-value and component.code-component.value pairs need to be taken into account to correctly understand the meaning of the observation.

        Контроль1..1
        На этот элемент влияют следующие инварианты: obs-7
        ПривязкаКоды СЛЕДУЕТ взять из Например, коды см. ObservationCodesVS (0.12.0)http://hl7.org/fhir/ValueSet/observation-codes|5.0.0
        (preferred to https://terminology.dhp.uz/fhir/core/ValueSet/observation-codes-vs|0.12.0)
        ТипCodeableConcept
        Модификаторfalse
        Требуется поддержкаtrue
        Summarytrue
        Требования

        Knowing what kind of observation is being made is essential to understanding the observation.

        Значение шаблона{
          "coding" : [{
            "system" : "https://terminology.dhp.uz/fhir/integrations/CodeSystem/screening-ultrasound-parameter-cs",
            "code" : "scrn-0052-00039"
          }]
        }
        Инвариантыele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
        ele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
        395. Observation.component:axillaryCorticalThickness.value[x]
        Определение

        The information determined as a result of making the observation, if the information has a simple value.

        КороткийActual component result
        Комментарии

        Used when observation has a set of component observations:

        • An observation may have both a value (e.g. an Apgar score) and component observations (the observations from which the Apgar score was derived).
        • If a value is present, the datatype for this element should be determined by the code.
        • CodeableConcept with just a text would be used instead of a string if the field was usually coded, or if the type associated with the code defines a coded value.
        • Attachment is used if the observation result value is a binary file such as an image. If the observation result value is derived from the binary file (for example 'X' detected and here is the the proof in this image), the binary file may be directly represented using DocumentReference and referenced by derivedFrom.
        • If a value is present, the datatype for this element should be determined by the code.
        • CodeableConcept with just a text would be used instead of a string if the field was usually coded, or if the type associated with the code defines a coded value.
        • Attachment is used if the observation result value is a binary file such as an image. If the observation result value is derived from the binary file (for example 'X' detected and here is the the proof in this image), the binary file may be directly represented using DocumentReference and referenced by derivedFrom.
        • The usage of valueReference is restricted to the MolecularSequence resource when used as a definitional resource, not as a patient-specific finding. .
        • For additional guidance, see the Notes section below.
        Контроль10..1
        ТипQuantity, dateTime, string, Reference(MolecularSequence), Period, Attachment, integer, Range, boolean, SampledData, Ratio, time, CodeableConcept
        [x] ЗаметкаСмотретьВыбор типов данныхдля дополнительной информации о том, как использовать [x]
        Модификаторfalse
        Требуется поддержкаtrue
        Summarytrue
        Требования

        An observation exists to have a value, though it might not if it is in error, or if it represents a group of observations.

        Значение шаблона{
          "unit" : "mm",
          "system" : "http://unitsofmeasure.org",
          "code" : "mm"
        }
        Инвариантыele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
        ele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
        397. Observation.component:axillaryCorticalThickness.value[x].value
        Определение

        The value of the measured amount. The value includes an implicit precision in the presentation of the value.

        КороткийNumerical value (with implicit precision)
        Комментарии

        The implicit precision in the value should always be honored. Monetary values have their own rules for handling precision (refer to standard accounting text books).

        Контроль10..1
        Типdecimal
        Модификаторfalse
        Примитивное значениеЭтот примитивный элемент может присутствовать или отсутствовать, или быть замененным расширением
        Summarytrue
        Требования

        Precision is handled implicitly in almost all cases of measurement.

        Мин. значение0
        Инвариантыele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
        ele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
        399. Observation.component:axillaryCorticalThickness.value[x].comparator
        Определение

        How the value should be understood and represented - whether the actual value is greater or less than the stated value due to measurement issues; e.g. if the comparator is "<" , then the real value is < stated value.

        Короткий< | <= | >= | > | ad - how to understand the value
        Контроль0..1
        ПривязкаКоды ДОЛЖНЫ быть взяты из QuantityComparatorhttp://hl7.org/fhir/ValueSet/quantity-comparator|5.0.0
        (required to http://hl7.org/fhir/ValueSet/quantity-comparator|5.0.0)

        How the Quantity should be understood and represented.

        Типcode
        Модификаторtrue потому что This is labeled as "Is Modifier" because the comparator modifies the interpretation of the value significantly. If there is no comparator, then there is no modification of the value
        Примитивное значениеЭтот примитивный элемент может присутствовать или отсутствовать, или быть замененным расширением
        Summarytrue
        Требования

        Need a framework for handling measures where the value is <5ug/L or >400mg/L due to the limitations of measuring methodology.

        Значение при отсутствииIf there is no comparator, then there is no modification of the value
        Инвариантыele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
        ele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
        401. Observation.component:axillaryCorticalThickness.value[x].unit
        Определение

        A human-readable form of the unit.

        КороткийUnit representation
        Контроль10..1
        Типstring
        Модификаторfalse
        Примитивное значениеЭтот примитивный элемент может присутствовать или отсутствовать, или быть замененным расширением
        Summarytrue
        Требования

        There are many representations for units of measure and in many contexts, particular representations are fixed and required. I.e. mcg for micrograms.

        Инвариантыele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
        ele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
        403. Observation.component:axillaryCorticalThickness.value[x].system
        Определение

        The identification of the system that provides the coded form of the unit.

        КороткийSystem that defines coded unit form
        Контроль10..1
        На этот элемент влияют следующие инварианты: qty-3
        Типuri
        Модификаторfalse
        Примитивное значениеЭтот примитивный элемент может присутствовать или отсутствовать, или быть замененным расширением
        Summarytrue
        Требования

        Need to know the system that defines the coded form of the unit.

        Инвариантыele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
        ele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
        405. Observation.component:axillaryCorticalThickness.value[x].code
        Определение

        A computer processable form of the unit in some unit representation system.

        КороткийCoded form of the unit
        Комментарии

        The preferred system is UCUM, but SNOMED CT can also be used (for customary units) or ISO 4217 for currency. The context of use may additionally require a code from a particular system.

        Контроль10..1
        На этот элемент влияют следующие инварианты: qty-3
        Типcode
        Модификаторfalse
        Примитивное значениеЭтот примитивный элемент может присутствовать или отсутствовать, или быть замененным расширением
        Summarytrue
        Требования

        Need a computable form of the unit that is fixed across all forms. UCUM provides this for quantities, but SNOMED CT provides many units of interest.

        Инвариантыele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
        ele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
        407. Observation.component:regionalNodeNote
        Название разрезаregionalNodeNote
        Определение

        Some observations have multiple component observations. These component observations are expressed as separate code value pairs that share the same attributes. Examples include systolic and diastolic component observations for blood pressure measurement and multiple component observations for genetics observations.

        КороткийComment about other regional lymph nodesComponent results
        Комментарии

        For a discussion on the ways Observations can be assembled in groups together see Notes below.

        Контроль0..1*
        На этот элемент влияют следующие инварианты: obs-7
        ТипBackboneElement
        Модификаторfalse
        Требуется поддержкаtrue
        Summarytrue
        Требования

        Component observations share the same attributes in the Observation resource as the primary observation and are always treated a part of a single observation (they are not separable). However, the reference range for the primary observation value is not inherited by the component values and is required when appropriate for each component observation.

        Инвариантыele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
        ele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
        409. Observation.component:regionalNodeNote.modifierExtension
        Определение

        May be used to represent additional information that is not part of the basic definition of the element and that modifies the understanding of the element in which it is contained and/or the understanding of the containing element's descendants. Usually modifier elements provide negation or qualification. To make the use of extensions safe and managable, there is a strict set of governance applied to the definition and use of extensions. Though any implementer can define an extension, there is a set of requirements that SHALL be met as part of the definition of the extension. Applications processing a resource are required to check for modifier extensions.

        Modifier extensions SHALL NOT change the meaning of any elements on Resource or DomainResource (including cannot change the meaning of modifierExtension itself).

        КороткийExtensions that cannot be ignored even if unrecognized
        Комментарии

        There can be no stigma associated with the use of extensions by any application, project, or standard - regardless of the institution or jurisdiction that uses or defines the extensions. The use of extensions is what allows the FHIR specification to retain a core level of simplicity for everyone.

        Контроль0..*
        ТипExtension
        Модификаторtrue потому что Modifier extensions are expected to modify the meaning or interpretation of the element that contains them
        Summarytrue
        Требования

        Modifier extensions allow for extensions that cannot be safely ignored to be clearly distinguished from the vast majority of extensions which can be safely ignored. This promotes interoperability by eliminating the need for implementers to prohibit the presence of extensions. For further information, see the definition of modifier extensions.

        Альтернативные именаextensions, user content, modifiers
        Инвариантыele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
        ext-1: Must have either extensions or value[x], not both (extension.exists() != value.exists())
        ele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
        ext-1: Must have either extensions or value[x], not both (extension.exists() != value.exists())
        411. Observation.component:regionalNodeNote.code
        Определение

        Describes what was observed. Sometimes this is called the observation "code".

        КороткийType of component observation (code / type)
        Комментарии

        All code-value and component.code-component.value pairs need to be taken into account to correctly understand the meaning of the observation.

        Контроль1..1
        На этот элемент влияют следующие инварианты: obs-7
        ПривязкаКоды СЛЕДУЕТ взять из Например, коды см. ObservationCodesVS (0.12.0)http://hl7.org/fhir/ValueSet/observation-codes|5.0.0
        (preferred to https://terminology.dhp.uz/fhir/core/ValueSet/observation-codes-vs|0.12.0)
        ТипCodeableConcept
        Модификаторfalse
        Требуется поддержкаtrue
        Summarytrue
        Требования

        Knowing what kind of observation is being made is essential to understanding the observation.

        Значение шаблона{
          "coding" : [{
            "system" : "https://terminology.dhp.uz/fhir/integrations/CodeSystem/screening-ultrasound-parameter-cs",
            "code" : "scrn-0052-00040"
          }]
        }
        Инвариантыele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
        ele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
        413. Observation.component:regionalNodeNote.value[x]
        Определение

        The information determined as a result of making the observation, if the information has a simple value.

        КороткийActual component result
        Комментарии

        Used when observation has a set of component observations:

        • An observation may have both a value (e.g. an Apgar score) and component observations (the observations from which the Apgar score was derived).
        • If a value is present, the datatype for this element should be determined by the code.
        • CodeableConcept with just a text would be used instead of a string if the field was usually coded, or if the type associated with the code defines a coded value.
        • Attachment is used if the observation result value is a binary file such as an image. If the observation result value is derived from the binary file (for example 'X' detected and here is the the proof in this image), the binary file may be directly represented using DocumentReference and referenced by derivedFrom.
        • If a value is present, the datatype for this element should be determined by the code.
        • CodeableConcept with just a text would be used instead of a string if the field was usually coded, or if the type associated with the code defines a coded value.
        • Attachment is used if the observation result value is a binary file such as an image. If the observation result value is derived from the binary file (for example 'X' detected and here is the the proof in this image), the binary file may be directly represented using DocumentReference and referenced by derivedFrom.
        • The usage of valueReference is restricted to the MolecularSequence resource when used as a definitional resource, not as a patient-specific finding. .
        • For additional guidance, see the Notes section below.
        Контроль10..1
        Типstring, dateTime, Reference(MolecularSequence), Quantity, Period, Attachment, integer, Range, boolean, SampledData, Ratio, time, CodeableConcept
        [x] ЗаметкаСмотретьВыбор типов данныхдля дополнительной информации о том, как использовать [x]
        Модификаторfalse
        Примитивное значениеЭтот примитивный элемент может присутствовать или отсутствовать, или быть замененным расширением
        Требуется поддержкаtrue
        Summarytrue
        Требования

        An observation exists to have a value, though it might not if it is in error, or if it represents a group of observations.

        Инвариантыele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
        ele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
        415. Observation.component:additionalChanges
        Название разрезаadditionalChanges
        Определение

        Some observations have multiple component observations. These component observations are expressed as separate code value pairs that share the same attributes. Examples include systolic and diastolic component observations for blood pressure measurement and multiple component observations for genetics observations.

        КороткийAdditional ultrasound changesComponent results
        Комментарии

        For a discussion on the ways Observations can be assembled in groups together see Notes below.

        Контроль0..1*
        На этот элемент влияют следующие инварианты: obs-7
        ТипBackboneElement
        Модификаторfalse
        Требуется поддержкаtrue
        Summarytrue
        Требования

        Component observations share the same attributes in the Observation resource as the primary observation and are always treated a part of a single observation (they are not separable). However, the reference range for the primary observation value is not inherited by the component values and is required when appropriate for each component observation.

        Инвариантыele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
        ele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
        417. Observation.component:additionalChanges.modifierExtension
        Определение

        May be used to represent additional information that is not part of the basic definition of the element and that modifies the understanding of the element in which it is contained and/or the understanding of the containing element's descendants. Usually modifier elements provide negation or qualification. To make the use of extensions safe and managable, there is a strict set of governance applied to the definition and use of extensions. Though any implementer can define an extension, there is a set of requirements that SHALL be met as part of the definition of the extension. Applications processing a resource are required to check for modifier extensions.

        Modifier extensions SHALL NOT change the meaning of any elements on Resource or DomainResource (including cannot change the meaning of modifierExtension itself).

        КороткийExtensions that cannot be ignored even if unrecognized
        Комментарии

        There can be no stigma associated with the use of extensions by any application, project, or standard - regardless of the institution or jurisdiction that uses or defines the extensions. The use of extensions is what allows the FHIR specification to retain a core level of simplicity for everyone.

        Контроль0..*
        ТипExtension
        Модификаторtrue потому что Modifier extensions are expected to modify the meaning or interpretation of the element that contains them
        Summarytrue
        Требования

        Modifier extensions allow for extensions that cannot be safely ignored to be clearly distinguished from the vast majority of extensions which can be safely ignored. This promotes interoperability by eliminating the need for implementers to prohibit the presence of extensions. For further information, see the definition of modifier extensions.

        Альтернативные именаextensions, user content, modifiers
        Инвариантыele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
        ext-1: Must have either extensions or value[x], not both (extension.exists() != value.exists())
        ele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
        ext-1: Must have either extensions or value[x], not both (extension.exists() != value.exists())
        419. Observation.component:additionalChanges.code
        Определение

        Describes what was observed. Sometimes this is called the observation "code".

        КороткийType of component observation (code / type)
        Комментарии

        All code-value and component.code-component.value pairs need to be taken into account to correctly understand the meaning of the observation.

        Контроль1..1
        На этот элемент влияют следующие инварианты: obs-7
        ПривязкаКоды СЛЕДУЕТ взять из Например, коды см. ObservationCodesVS (0.12.0)http://hl7.org/fhir/ValueSet/observation-codes|5.0.0
        (preferred to https://terminology.dhp.uz/fhir/core/ValueSet/observation-codes-vs|0.12.0)
        ТипCodeableConcept
        Модификаторfalse
        Требуется поддержкаtrue
        Summarytrue
        Требования

        Knowing what kind of observation is being made is essential to understanding the observation.

        Значение шаблона{
          "coding" : [{
            "system" : "https://terminology.dhp.uz/fhir/integrations/CodeSystem/screening-ultrasound-parameter-cs",
            "code" : "scrn-0052-00019"
          }]
        }
        Инвариантыele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
        ele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
        421. Observation.component:additionalChanges.value[x]
        Определение

        The information determined as a result of making the observation, if the information has a simple value.

        КороткийActual component result
        Комментарии

        Used when observation has a set of component observations:

        • An observation may have both a value (e.g. an Apgar score) and component observations (the observations from which the Apgar score was derived).
        • If a value is present, the datatype for this element should be determined by the code.
        • CodeableConcept with just a text would be used instead of a string if the field was usually coded, or if the type associated with the code defines a coded value.
        • Attachment is used if the observation result value is a binary file such as an image. If the observation result value is derived from the binary file (for example 'X' detected and here is the the proof in this image), the binary file may be directly represented using DocumentReference and referenced by derivedFrom.
        • If a value is present, the datatype for this element should be determined by the code.
        • CodeableConcept with just a text would be used instead of a string if the field was usually coded, or if the type associated with the code defines a coded value.
        • Attachment is used if the observation result value is a binary file such as an image. If the observation result value is derived from the binary file (for example 'X' detected and here is the the proof in this image), the binary file may be directly represented using DocumentReference and referenced by derivedFrom.
        • The usage of valueReference is restricted to the MolecularSequence resource when used as a definitional resource, not as a patient-specific finding. .
        • For additional guidance, see the Notes section below.
        Контроль10..1
        Типstring, dateTime, Reference(MolecularSequence), Quantity, Period, Attachment, integer, Range, boolean, SampledData, Ratio, time, CodeableConcept
        [x] ЗаметкаСмотретьВыбор типов данныхдля дополнительной информации о том, как использовать [x]
        Модификаторfalse
        Примитивное значениеЭтот примитивный элемент может присутствовать или отсутствовать, или быть замененным расширением
        Требуется поддержкаtrue
        Summarytrue
        Требования

        An observation exists to have a value, though it might not if it is in error, or if it represents a group of observations.

        Инвариантыele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
        ele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
        423. Observation.component:focalLesionPresent
        Название разрезаfocalLesionPresent
        Определение

        Some observations have multiple component observations. These component observations are expressed as separate code value pairs that share the same attributes. Examples include systolic and diastolic component observations for blood pressure measurement and multiple component observations for genetics observations.

        КороткийFocal breast lesion presentComponent results
        Комментарии

        For a discussion on the ways Observations can be assembled in groups together see Notes below.

        Контроль0..1*
        На этот элемент влияют следующие инварианты: obs-7
        ТипBackboneElement
        Модификаторfalse
        Требуется поддержкаtrue
        Summarytrue
        Требования

        Component observations share the same attributes in the Observation resource as the primary observation and are always treated a part of a single observation (they are not separable). However, the reference range for the primary observation value is not inherited by the component values and is required when appropriate for each component observation.

        Инвариантыele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
        ele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
        425. Observation.component:focalLesionPresent.modifierExtension
        Определение

        May be used to represent additional information that is not part of the basic definition of the element and that modifies the understanding of the element in which it is contained and/or the understanding of the containing element's descendants. Usually modifier elements provide negation or qualification. To make the use of extensions safe and managable, there is a strict set of governance applied to the definition and use of extensions. Though any implementer can define an extension, there is a set of requirements that SHALL be met as part of the definition of the extension. Applications processing a resource are required to check for modifier extensions.

        Modifier extensions SHALL NOT change the meaning of any elements on Resource or DomainResource (including cannot change the meaning of modifierExtension itself).

        КороткийExtensions that cannot be ignored even if unrecognized
        Комментарии

        There can be no stigma associated with the use of extensions by any application, project, or standard - regardless of the institution or jurisdiction that uses or defines the extensions. The use of extensions is what allows the FHIR specification to retain a core level of simplicity for everyone.

        Контроль0..*
        ТипExtension
        Модификаторtrue потому что Modifier extensions are expected to modify the meaning or interpretation of the element that contains them
        Summarytrue
        Требования

        Modifier extensions allow for extensions that cannot be safely ignored to be clearly distinguished from the vast majority of extensions which can be safely ignored. This promotes interoperability by eliminating the need for implementers to prohibit the presence of extensions. For further information, see the definition of modifier extensions.

        Альтернативные именаextensions, user content, modifiers
        Инвариантыele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
        ext-1: Must have either extensions or value[x], not both (extension.exists() != value.exists())
        ele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
        ext-1: Must have either extensions or value[x], not both (extension.exists() != value.exists())
        427. Observation.component:focalLesionPresent.code
        Определение

        Describes what was observed. Sometimes this is called the observation "code".

        КороткийType of component observation (code / type)
        Комментарии

        All code-value and component.code-component.value pairs need to be taken into account to correctly understand the meaning of the observation.

        Контроль1..1
        На этот элемент влияют следующие инварианты: obs-7
        ПривязкаКоды СЛЕДУЕТ взять из Например, коды см. ObservationCodesVS (0.12.0)http://hl7.org/fhir/ValueSet/observation-codes|5.0.0
        (preferred to https://terminology.dhp.uz/fhir/core/ValueSet/observation-codes-vs|0.12.0)
        ТипCodeableConcept
        Модификаторfalse
        Требуется поддержкаtrue
        Summarytrue
        Требования

        Knowing what kind of observation is being made is essential to understanding the observation.

        Значение шаблона{
          "coding" : [{
            "system" : "https://terminology.dhp.uz/fhir/integrations/CodeSystem/screening-ultrasound-parameter-cs",
            "code" : "scrn-0052-00021"
          }]
        }
        Инвариантыele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
        ele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
        429. Observation.component:focalLesionPresent.value[x]
        Определение

        The information determined as a result of making the observation, if the information has a simple value.

        КороткийActual component result
        Комментарии

        Used when observation has a set of component observations:

        • An observation may have both a value (e.g. an Apgar score) and component observations (the observations from which the Apgar score was derived).
        • If a value is present, the datatype for this element should be determined by the code.
        • CodeableConcept with just a text would be used instead of a string if the field was usually coded, or if the type associated with the code defines a coded value.
        • Attachment is used if the observation result value is a binary file such as an image. If the observation result value is derived from the binary file (for example 'X' detected and here is the the proof in this image), the binary file may be directly represented using DocumentReference and referenced by derivedFrom.
        • If a value is present, the datatype for this element should be determined by the code.
        • CodeableConcept with just a text would be used instead of a string if the field was usually coded, or if the type associated with the code defines a coded value.
        • Attachment is used if the observation result value is a binary file such as an image. If the observation result value is derived from the binary file (for example 'X' detected and here is the the proof in this image), the binary file may be directly represented using DocumentReference and referenced by derivedFrom.
        • The usage of valueReference is restricted to the MolecularSequence resource when used as a definitional resource, not as a patient-specific finding. .
        • For additional guidance, see the Notes section below.
        Контроль10..1
        Типboolean, dateTime, string, Reference(MolecularSequence), Quantity, Period, Attachment, integer, Range, SampledData, Ratio, time, CodeableConcept
        [x] ЗаметкаСмотретьВыбор типов данныхдля дополнительной информации о том, как использовать [x]
        Модификаторfalse
        Примитивное значениеЭтот примитивный элемент может присутствовать или отсутствовать, или быть замененным расширением
        Требуется поддержкаtrue
        Summarytrue
        Требования

        An observation exists to have a value, though it might not if it is in error, or if it represents a group of observations.

        Инвариантыele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
        ele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
        431. Observation.component:clockFacePosition
        Название разрезаclockFacePosition
        Определение

        Some observations have multiple component observations. These component observations are expressed as separate code value pairs that share the same attributes. Examples include systolic and diastolic component observations for blood pressure measurement and multiple component observations for genetics observations.

        КороткийLesion clock-face position, 1 to 12Component results
        Комментарии

        For a discussion on the ways Observations can be assembled in groups together see Notes below.

        Контроль0..1*
        На этот элемент влияют следующие инварианты: obs-7
        ТипBackboneElement
        Модификаторfalse
        Требуется поддержкаtrue
        Summarytrue
        Требования

        Component observations share the same attributes in the Observation resource as the primary observation and are always treated a part of a single observation (they are not separable). However, the reference range for the primary observation value is not inherited by the component values and is required when appropriate for each component observation.

        Инвариантыele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
        ele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
        433. Observation.component:clockFacePosition.modifierExtension
        Определение

        May be used to represent additional information that is not part of the basic definition of the element and that modifies the understanding of the element in which it is contained and/or the understanding of the containing element's descendants. Usually modifier elements provide negation or qualification. To make the use of extensions safe and managable, there is a strict set of governance applied to the definition and use of extensions. Though any implementer can define an extension, there is a set of requirements that SHALL be met as part of the definition of the extension. Applications processing a resource are required to check for modifier extensions.

        Modifier extensions SHALL NOT change the meaning of any elements on Resource or DomainResource (including cannot change the meaning of modifierExtension itself).

        КороткийExtensions that cannot be ignored even if unrecognized
        Комментарии

        There can be no stigma associated with the use of extensions by any application, project, or standard - regardless of the institution or jurisdiction that uses or defines the extensions. The use of extensions is what allows the FHIR specification to retain a core level of simplicity for everyone.

        Контроль0..*
        ТипExtension
        Модификаторtrue потому что Modifier extensions are expected to modify the meaning or interpretation of the element that contains them
        Summarytrue
        Требования

        Modifier extensions allow for extensions that cannot be safely ignored to be clearly distinguished from the vast majority of extensions which can be safely ignored. This promotes interoperability by eliminating the need for implementers to prohibit the presence of extensions. For further information, see the definition of modifier extensions.

        Альтернативные именаextensions, user content, modifiers
        Инвариантыele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
        ext-1: Must have either extensions or value[x], not both (extension.exists() != value.exists())
        ele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
        ext-1: Must have either extensions or value[x], not both (extension.exists() != value.exists())
        435. Observation.component:clockFacePosition.code
        Определение

        Describes what was observed. Sometimes this is called the observation "code".

        КороткийType of component observation (code / type)
        Комментарии

        All code-value and component.code-component.value pairs need to be taken into account to correctly understand the meaning of the observation.

        Контроль1..1
        На этот элемент влияют следующие инварианты: obs-7
        ПривязкаКоды СЛЕДУЕТ взять из Например, коды см. ObservationCodesVS (0.12.0)http://hl7.org/fhir/ValueSet/observation-codes|5.0.0
        (preferred to https://terminology.dhp.uz/fhir/core/ValueSet/observation-codes-vs|0.12.0)
        ТипCodeableConcept
        Модификаторfalse
        Требуется поддержкаtrue
        Summarytrue
        Требования

        Knowing what kind of observation is being made is essential to understanding the observation.

        Значение шаблона{
          "coding" : [{
            "system" : "https://terminology.dhp.uz/fhir/integrations/CodeSystem/screening-ultrasound-parameter-cs",
            "code" : "scrn-0052-00022"
          }]
        }
        Инвариантыele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
        ele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
        437. Observation.component:clockFacePosition.value[x]
        Определение

        The information determined as a result of making the observation, if the information has a simple value.

        КороткийActual component result
        Комментарии

        Used when observation has a set of component observations:

        • An observation may have both a value (e.g. an Apgar score) and component observations (the observations from which the Apgar score was derived).
        • If a value is present, the datatype for this element should be determined by the code.
        • CodeableConcept with just a text would be used instead of a string if the field was usually coded, or if the type associated with the code defines a coded value.
        • Attachment is used if the observation result value is a binary file such as an image. If the observation result value is derived from the binary file (for example 'X' detected and here is the the proof in this image), the binary file may be directly represented using DocumentReference and referenced by derivedFrom.
        • If a value is present, the datatype for this element should be determined by the code.
        • CodeableConcept with just a text would be used instead of a string if the field was usually coded, or if the type associated with the code defines a coded value.
        • Attachment is used if the observation result value is a binary file such as an image. If the observation result value is derived from the binary file (for example 'X' detected and here is the the proof in this image), the binary file may be directly represented using DocumentReference and referenced by derivedFrom.
        • The usage of valueReference is restricted to the MolecularSequence resource when used as a definitional resource, not as a patient-specific finding. .
        • For additional guidance, see the Notes section below.
        Контроль10..1
        Типinteger, dateTime, string, Reference(MolecularSequence), Quantity, Period, Attachment, Range, boolean, SampledData, Ratio, time, CodeableConcept
        [x] ЗаметкаСмотретьВыбор типов данныхдля дополнительной информации о том, как использовать [x]
        Модификаторfalse
        Примитивное значениеЭтот примитивный элемент может присутствовать или отсутствовать, или быть замененным расширением
        Требуется поддержкаtrue
        Summarytrue
        Требования

        An observation exists to have a value, though it might not if it is in error, or if it represents a group of observations.

        Мин. значение1
        Максимальное значение12
        Инвариантыele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
        ele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
        439. Observation.component:distanceFromNipple
        Название разрезаdistanceFromNipple
        Определение

        Some observations have multiple component observations. These component observations are expressed as separate code value pairs that share the same attributes. Examples include systolic and diastolic component observations for blood pressure measurement and multiple component observations for genetics observations.

        КороткийDistance from nippleComponent results
        Комментарии

        For a discussion on the ways Observations can be assembled in groups together see Notes below.

        Контроль0..1*
        На этот элемент влияют следующие инварианты: obs-7
        ТипBackboneElement
        Модификаторfalse
        Требуется поддержкаtrue
        Summarytrue
        Требования

        Component observations share the same attributes in the Observation resource as the primary observation and are always treated a part of a single observation (they are not separable). However, the reference range for the primary observation value is not inherited by the component values and is required when appropriate for each component observation.

        Инвариантыele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
        ele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
        441. Observation.component:distanceFromNipple.modifierExtension
        Определение

        May be used to represent additional information that is not part of the basic definition of the element and that modifies the understanding of the element in which it is contained and/or the understanding of the containing element's descendants. Usually modifier elements provide negation or qualification. To make the use of extensions safe and managable, there is a strict set of governance applied to the definition and use of extensions. Though any implementer can define an extension, there is a set of requirements that SHALL be met as part of the definition of the extension. Applications processing a resource are required to check for modifier extensions.

        Modifier extensions SHALL NOT change the meaning of any elements on Resource or DomainResource (including cannot change the meaning of modifierExtension itself).

        КороткийExtensions that cannot be ignored even if unrecognized
        Комментарии

        There can be no stigma associated with the use of extensions by any application, project, or standard - regardless of the institution or jurisdiction that uses or defines the extensions. The use of extensions is what allows the FHIR specification to retain a core level of simplicity for everyone.

        Контроль0..*
        ТипExtension
        Модификаторtrue потому что Modifier extensions are expected to modify the meaning or interpretation of the element that contains them
        Summarytrue
        Требования

        Modifier extensions allow for extensions that cannot be safely ignored to be clearly distinguished from the vast majority of extensions which can be safely ignored. This promotes interoperability by eliminating the need for implementers to prohibit the presence of extensions. For further information, see the definition of modifier extensions.

        Альтернативные именаextensions, user content, modifiers
        Инвариантыele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
        ext-1: Must have either extensions or value[x], not both (extension.exists() != value.exists())
        ele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
        ext-1: Must have either extensions or value[x], not both (extension.exists() != value.exists())
        443. Observation.component:distanceFromNipple.code
        Определение

        Describes what was observed. Sometimes this is called the observation "code".

        КороткийType of component observation (code / type)
        Комментарии

        All code-value and component.code-component.value pairs need to be taken into account to correctly understand the meaning of the observation.

        Контроль1..1
        На этот элемент влияют следующие инварианты: obs-7
        ПривязкаКоды СЛЕДУЕТ взять из Например, коды см. ObservationCodesVS (0.12.0)http://hl7.org/fhir/ValueSet/observation-codes|5.0.0
        (preferred to https://terminology.dhp.uz/fhir/core/ValueSet/observation-codes-vs|0.12.0)
        ТипCodeableConcept
        Модификаторfalse
        Требуется поддержкаtrue
        Summarytrue
        Требования

        Knowing what kind of observation is being made is essential to understanding the observation.

        Значение шаблона{
          "coding" : [{
            "system" : "https://terminology.dhp.uz/fhir/integrations/CodeSystem/screening-ultrasound-parameter-cs",
            "code" : "scrn-0052-00023"
          }]
        }
        Инвариантыele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
        ele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
        445. Observation.component:distanceFromNipple.value[x]
        Определение

        The information determined as a result of making the observation, if the information has a simple value.

        КороткийActual component result
        Комментарии

        Used when observation has a set of component observations:

        • An observation may have both a value (e.g. an Apgar score) and component observations (the observations from which the Apgar score was derived).
        • If a value is present, the datatype for this element should be determined by the code.
        • CodeableConcept with just a text would be used instead of a string if the field was usually coded, or if the type associated with the code defines a coded value.
        • Attachment is used if the observation result value is a binary file such as an image. If the observation result value is derived from the binary file (for example 'X' detected and here is the the proof in this image), the binary file may be directly represented using DocumentReference and referenced by derivedFrom.
        • If a value is present, the datatype for this element should be determined by the code.
        • CodeableConcept with just a text would be used instead of a string if the field was usually coded, or if the type associated with the code defines a coded value.
        • Attachment is used if the observation result value is a binary file such as an image. If the observation result value is derived from the binary file (for example 'X' detected and here is the the proof in this image), the binary file may be directly represented using DocumentReference and referenced by derivedFrom.
        • The usage of valueReference is restricted to the MolecularSequence resource when used as a definitional resource, not as a patient-specific finding. .
        • For additional guidance, see the Notes section below.
        Контроль10..1
        ТипQuantity, dateTime, string, Reference(MolecularSequence), Period, Attachment, integer, Range, boolean, SampledData, Ratio, time, CodeableConcept
        [x] ЗаметкаСмотретьВыбор типов данныхдля дополнительной информации о том, как использовать [x]
        Модификаторfalse
        Требуется поддержкаtrue
        Summarytrue
        Требования

        An observation exists to have a value, though it might not if it is in error, or if it represents a group of observations.

        Значение шаблона{
          "unit" : "mm",
          "system" : "http://unitsofmeasure.org",
          "code" : "mm"
        }
        Инвариантыele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
        ele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
        447. Observation.component:distanceFromNipple.value[x].value
        Определение

        The value of the measured amount. The value includes an implicit precision in the presentation of the value.

        КороткийNumerical value (with implicit precision)
        Комментарии

        The implicit precision in the value should always be honored. Monetary values have their own rules for handling precision (refer to standard accounting text books).

        Контроль10..1
        Типdecimal
        Модификаторfalse
        Примитивное значениеЭтот примитивный элемент может присутствовать или отсутствовать, или быть замененным расширением
        Summarytrue
        Требования

        Precision is handled implicitly in almost all cases of measurement.

        Мин. значение0
        Инвариантыele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
        ele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
        449. Observation.component:distanceFromNipple.value[x].comparator
        Определение

        How the value should be understood and represented - whether the actual value is greater or less than the stated value due to measurement issues; e.g. if the comparator is "<" , then the real value is < stated value.

        Короткий< | <= | >= | > | ad - how to understand the value
        Контроль0..1
        ПривязкаКоды ДОЛЖНЫ быть взяты из QuantityComparatorhttp://hl7.org/fhir/ValueSet/quantity-comparator|5.0.0
        (required to http://hl7.org/fhir/ValueSet/quantity-comparator|5.0.0)

        How the Quantity should be understood and represented.

        Типcode
        Модификаторtrue потому что This is labeled as "Is Modifier" because the comparator modifies the interpretation of the value significantly. If there is no comparator, then there is no modification of the value
        Примитивное значениеЭтот примитивный элемент может присутствовать или отсутствовать, или быть замененным расширением
        Summarytrue
        Требования

        Need a framework for handling measures where the value is <5ug/L or >400mg/L due to the limitations of measuring methodology.

        Значение при отсутствииIf there is no comparator, then there is no modification of the value
        Инвариантыele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
        ele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
        451. Observation.component:distanceFromNipple.value[x].unit
        Определение

        A human-readable form of the unit.

        КороткийUnit representation
        Контроль10..1
        Типstring
        Модификаторfalse
        Примитивное значениеЭтот примитивный элемент может присутствовать или отсутствовать, или быть замененным расширением
        Summarytrue
        Требования

        There are many representations for units of measure and in many contexts, particular representations are fixed and required. I.e. mcg for micrograms.

        Инвариантыele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
        ele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
        453. Observation.component:distanceFromNipple.value[x].system
        Определение

        The identification of the system that provides the coded form of the unit.

        КороткийSystem that defines coded unit form
        Контроль10..1
        На этот элемент влияют следующие инварианты: qty-3
        Типuri
        Модификаторfalse
        Примитивное значениеЭтот примитивный элемент может присутствовать или отсутствовать, или быть замененным расширением
        Summarytrue
        Требования

        Need to know the system that defines the coded form of the unit.

        Инвариантыele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
        ele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
        455. Observation.component:distanceFromNipple.value[x].code
        Определение

        A computer processable form of the unit in some unit representation system.

        КороткийCoded form of the unit
        Комментарии

        The preferred system is UCUM, but SNOMED CT can also be used (for customary units) or ISO 4217 for currency. The context of use may additionally require a code from a particular system.

        Контроль10..1
        На этот элемент влияют следующие инварианты: qty-3
        Типcode
        Модификаторfalse
        Примитивное значениеЭтот примитивный элемент может присутствовать или отсутствовать, или быть замененным расширением
        Summarytrue
        Требования

        Need a computable form of the unit that is fixed across all forms. UCUM provides this for quantities, but SNOMED CT provides many units of interest.

        Инвариантыele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
        ele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
        457. Observation.component:lesionLength
        Название разрезаlesionLength
        Определение

        Some observations have multiple component observations. These component observations are expressed as separate code value pairs that share the same attributes. Examples include systolic and diastolic component observations for blood pressure measurement and multiple component observations for genetics observations.

        КороткийLesion lengthComponent results
        Комментарии

        For a discussion on the ways Observations can be assembled in groups together see Notes below.

        Контроль0..1*
        На этот элемент влияют следующие инварианты: obs-7
        ТипBackboneElement
        Модификаторfalse
        Требуется поддержкаtrue
        Summarytrue
        Требования

        Component observations share the same attributes in the Observation resource as the primary observation and are always treated a part of a single observation (they are not separable). However, the reference range for the primary observation value is not inherited by the component values and is required when appropriate for each component observation.

        Инвариантыele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
        ele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
        459. Observation.component:lesionLength.modifierExtension
        Определение

        May be used to represent additional information that is not part of the basic definition of the element and that modifies the understanding of the element in which it is contained and/or the understanding of the containing element's descendants. Usually modifier elements provide negation or qualification. To make the use of extensions safe and managable, there is a strict set of governance applied to the definition and use of extensions. Though any implementer can define an extension, there is a set of requirements that SHALL be met as part of the definition of the extension. Applications processing a resource are required to check for modifier extensions.

        Modifier extensions SHALL NOT change the meaning of any elements on Resource or DomainResource (including cannot change the meaning of modifierExtension itself).

        КороткийExtensions that cannot be ignored even if unrecognized
        Комментарии

        There can be no stigma associated with the use of extensions by any application, project, or standard - regardless of the institution or jurisdiction that uses or defines the extensions. The use of extensions is what allows the FHIR specification to retain a core level of simplicity for everyone.

        Контроль0..*
        ТипExtension
        Модификаторtrue потому что Modifier extensions are expected to modify the meaning or interpretation of the element that contains them
        Summarytrue
        Требования

        Modifier extensions allow for extensions that cannot be safely ignored to be clearly distinguished from the vast majority of extensions which can be safely ignored. This promotes interoperability by eliminating the need for implementers to prohibit the presence of extensions. For further information, see the definition of modifier extensions.

        Альтернативные именаextensions, user content, modifiers
        Инвариантыele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
        ext-1: Must have either extensions or value[x], not both (extension.exists() != value.exists())
        ele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
        ext-1: Must have either extensions or value[x], not both (extension.exists() != value.exists())
        461. Observation.component:lesionLength.code
        Определение

        Describes what was observed. Sometimes this is called the observation "code".

        КороткийType of component observation (code / type)
        Комментарии

        All code-value and component.code-component.value pairs need to be taken into account to correctly understand the meaning of the observation.

        Контроль1..1
        На этот элемент влияют следующие инварианты: obs-7
        ПривязкаКоды СЛЕДУЕТ взять из Например, коды см. ObservationCodesVS (0.12.0)http://hl7.org/fhir/ValueSet/observation-codes|5.0.0
        (preferred to https://terminology.dhp.uz/fhir/core/ValueSet/observation-codes-vs|0.12.0)
        ТипCodeableConcept
        Модификаторfalse
        Требуется поддержкаtrue
        Summarytrue
        Требования

        Knowing what kind of observation is being made is essential to understanding the observation.

        Значение шаблона{
          "coding" : [{
            "system" : "https://terminology.dhp.uz/fhir/integrations/CodeSystem/screening-ultrasound-parameter-cs",
            "code" : "scrn-0052-00024"
          }]
        }
        Инвариантыele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
        ele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
        463. Observation.component:lesionLength.value[x]
        Определение

        The information determined as a result of making the observation, if the information has a simple value.

        КороткийActual component result
        Комментарии

        Used when observation has a set of component observations:

        • An observation may have both a value (e.g. an Apgar score) and component observations (the observations from which the Apgar score was derived).
        • If a value is present, the datatype for this element should be determined by the code.
        • CodeableConcept with just a text would be used instead of a string if the field was usually coded, or if the type associated with the code defines a coded value.
        • Attachment is used if the observation result value is a binary file such as an image. If the observation result value is derived from the binary file (for example 'X' detected and here is the the proof in this image), the binary file may be directly represented using DocumentReference and referenced by derivedFrom.
        • If a value is present, the datatype for this element should be determined by the code.
        • CodeableConcept with just a text would be used instead of a string if the field was usually coded, or if the type associated with the code defines a coded value.
        • Attachment is used if the observation result value is a binary file such as an image. If the observation result value is derived from the binary file (for example 'X' detected and here is the the proof in this image), the binary file may be directly represented using DocumentReference and referenced by derivedFrom.
        • The usage of valueReference is restricted to the MolecularSequence resource when used as a definitional resource, not as a patient-specific finding. .
        • For additional guidance, see the Notes section below.
        Контроль10..1
        ТипQuantity, dateTime, string, Reference(MolecularSequence), Period, Attachment, integer, Range, boolean, SampledData, Ratio, time, CodeableConcept
        [x] ЗаметкаСмотретьВыбор типов данныхдля дополнительной информации о том, как использовать [x]
        Модификаторfalse
        Требуется поддержкаtrue
        Summarytrue
        Требования

        An observation exists to have a value, though it might not if it is in error, or if it represents a group of observations.

        Значение шаблона{
          "unit" : "mm",
          "system" : "http://unitsofmeasure.org",
          "code" : "mm"
        }
        Инвариантыele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
        ele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
        465. Observation.component:lesionLength.value[x].value
        Определение

        The value of the measured amount. The value includes an implicit precision in the presentation of the value.

        КороткийNumerical value (with implicit precision)
        Комментарии

        The implicit precision in the value should always be honored. Monetary values have their own rules for handling precision (refer to standard accounting text books).

        Контроль10..1
        Типdecimal
        Модификаторfalse
        Примитивное значениеЭтот примитивный элемент может присутствовать или отсутствовать, или быть замененным расширением
        Summarytrue
        Требования

        Precision is handled implicitly in almost all cases of measurement.

        Мин. значение0
        Инвариантыele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
        ele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
        467. Observation.component:lesionLength.value[x].comparator
        Определение

        How the value should be understood and represented - whether the actual value is greater or less than the stated value due to measurement issues; e.g. if the comparator is "<" , then the real value is < stated value.

        Короткий< | <= | >= | > | ad - how to understand the value
        Контроль0..1
        ПривязкаКоды ДОЛЖНЫ быть взяты из QuantityComparatorhttp://hl7.org/fhir/ValueSet/quantity-comparator|5.0.0
        (required to http://hl7.org/fhir/ValueSet/quantity-comparator|5.0.0)

        How the Quantity should be understood and represented.

        Типcode
        Модификаторtrue потому что This is labeled as "Is Modifier" because the comparator modifies the interpretation of the value significantly. If there is no comparator, then there is no modification of the value
        Примитивное значениеЭтот примитивный элемент может присутствовать или отсутствовать, или быть замененным расширением
        Summarytrue
        Требования

        Need a framework for handling measures where the value is <5ug/L or >400mg/L due to the limitations of measuring methodology.

        Значение при отсутствииIf there is no comparator, then there is no modification of the value
        Инвариантыele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
        ele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
        469. Observation.component:lesionLength.value[x].unit
        Определение

        A human-readable form of the unit.

        КороткийUnit representation
        Контроль10..1
        Типstring
        Модификаторfalse
        Примитивное значениеЭтот примитивный элемент может присутствовать или отсутствовать, или быть замененным расширением
        Summarytrue
        Требования

        There are many representations for units of measure and in many contexts, particular representations are fixed and required. I.e. mcg for micrograms.

        Инвариантыele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
        ele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
        471. Observation.component:lesionLength.value[x].system
        Определение

        The identification of the system that provides the coded form of the unit.

        КороткийSystem that defines coded unit form
        Контроль10..1
        На этот элемент влияют следующие инварианты: qty-3
        Типuri
        Модификаторfalse
        Примитивное значениеЭтот примитивный элемент может присутствовать или отсутствовать, или быть замененным расширением
        Summarytrue
        Требования

        Need to know the system that defines the coded form of the unit.

        Инвариантыele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
        ele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
        473. Observation.component:lesionLength.value[x].code
        Определение

        A computer processable form of the unit in some unit representation system.

        КороткийCoded form of the unit
        Комментарии

        The preferred system is UCUM, but SNOMED CT can also be used (for customary units) or ISO 4217 for currency. The context of use may additionally require a code from a particular system.

        Контроль10..1
        На этот элемент влияют следующие инварианты: qty-3
        Типcode
        Модификаторfalse
        Примитивное значениеЭтот примитивный элемент может присутствовать или отсутствовать, или быть замененным расширением
        Summarytrue
        Требования

        Need a computable form of the unit that is fixed across all forms. UCUM provides this for quantities, but SNOMED CT provides many units of interest.

        Инвариантыele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
        ele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
        475. Observation.component:lesionWidth
        Название разрезаlesionWidth
        Определение

        Some observations have multiple component observations. These component observations are expressed as separate code value pairs that share the same attributes. Examples include systolic and diastolic component observations for blood pressure measurement and multiple component observations for genetics observations.

        КороткийLesion widthComponent results
        Комментарии

        For a discussion on the ways Observations can be assembled in groups together see Notes below.

        Контроль0..1*
        На этот элемент влияют следующие инварианты: obs-7
        ТипBackboneElement
        Модификаторfalse
        Требуется поддержкаtrue
        Summarytrue
        Требования

        Component observations share the same attributes in the Observation resource as the primary observation and are always treated a part of a single observation (they are not separable). However, the reference range for the primary observation value is not inherited by the component values and is required when appropriate for each component observation.

        Инвариантыele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
        ele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
        477. Observation.component:lesionWidth.modifierExtension
        Определение

        May be used to represent additional information that is not part of the basic definition of the element and that modifies the understanding of the element in which it is contained and/or the understanding of the containing element's descendants. Usually modifier elements provide negation or qualification. To make the use of extensions safe and managable, there is a strict set of governance applied to the definition and use of extensions. Though any implementer can define an extension, there is a set of requirements that SHALL be met as part of the definition of the extension. Applications processing a resource are required to check for modifier extensions.

        Modifier extensions SHALL NOT change the meaning of any elements on Resource or DomainResource (including cannot change the meaning of modifierExtension itself).

        КороткийExtensions that cannot be ignored even if unrecognized
        Комментарии

        There can be no stigma associated with the use of extensions by any application, project, or standard - regardless of the institution or jurisdiction that uses or defines the extensions. The use of extensions is what allows the FHIR specification to retain a core level of simplicity for everyone.

        Контроль0..*
        ТипExtension
        Модификаторtrue потому что Modifier extensions are expected to modify the meaning or interpretation of the element that contains them
        Summarytrue
        Требования

        Modifier extensions allow for extensions that cannot be safely ignored to be clearly distinguished from the vast majority of extensions which can be safely ignored. This promotes interoperability by eliminating the need for implementers to prohibit the presence of extensions. For further information, see the definition of modifier extensions.

        Альтернативные именаextensions, user content, modifiers
        Инвариантыele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
        ext-1: Must have either extensions or value[x], not both (extension.exists() != value.exists())
        ele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
        ext-1: Must have either extensions or value[x], not both (extension.exists() != value.exists())
        479. Observation.component:lesionWidth.code
        Определение

        Describes what was observed. Sometimes this is called the observation "code".

        КороткийType of component observation (code / type)
        Комментарии

        All code-value and component.code-component.value pairs need to be taken into account to correctly understand the meaning of the observation.

        Контроль1..1
        На этот элемент влияют следующие инварианты: obs-7
        ПривязкаКоды СЛЕДУЕТ взять из Например, коды см. ObservationCodesVS (0.12.0)http://hl7.org/fhir/ValueSet/observation-codes|5.0.0
        (preferred to https://terminology.dhp.uz/fhir/core/ValueSet/observation-codes-vs|0.12.0)
        ТипCodeableConcept
        Модификаторfalse
        Требуется поддержкаtrue
        Summarytrue
        Требования

        Knowing what kind of observation is being made is essential to understanding the observation.

        Значение шаблона{
          "coding" : [{
            "system" : "https://terminology.dhp.uz/fhir/integrations/CodeSystem/screening-ultrasound-parameter-cs",
            "code" : "scrn-0052-00025"
          }]
        }
        Инвариантыele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
        ele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
        481. Observation.component:lesionWidth.value[x]
        Определение

        The information determined as a result of making the observation, if the information has a simple value.

        КороткийActual component result
        Комментарии

        Used when observation has a set of component observations:

        • An observation may have both a value (e.g. an Apgar score) and component observations (the observations from which the Apgar score was derived).
        • If a value is present, the datatype for this element should be determined by the code.
        • CodeableConcept with just a text would be used instead of a string if the field was usually coded, or if the type associated with the code defines a coded value.
        • Attachment is used if the observation result value is a binary file such as an image. If the observation result value is derived from the binary file (for example 'X' detected and here is the the proof in this image), the binary file may be directly represented using DocumentReference and referenced by derivedFrom.
        • If a value is present, the datatype for this element should be determined by the code.
        • CodeableConcept with just a text would be used instead of a string if the field was usually coded, or if the type associated with the code defines a coded value.
        • Attachment is used if the observation result value is a binary file such as an image. If the observation result value is derived from the binary file (for example 'X' detected and here is the the proof in this image), the binary file may be directly represented using DocumentReference and referenced by derivedFrom.
        • The usage of valueReference is restricted to the MolecularSequence resource when used as a definitional resource, not as a patient-specific finding. .
        • For additional guidance, see the Notes section below.
        Контроль10..1
        ТипQuantity, dateTime, string, Reference(MolecularSequence), Period, Attachment, integer, Range, boolean, SampledData, Ratio, time, CodeableConcept
        [x] ЗаметкаСмотретьВыбор типов данныхдля дополнительной информации о том, как использовать [x]
        Модификаторfalse
        Требуется поддержкаtrue
        Summarytrue
        Требования

        An observation exists to have a value, though it might not if it is in error, or if it represents a group of observations.

        Значение шаблона{
          "unit" : "mm",
          "system" : "http://unitsofmeasure.org",
          "code" : "mm"
        }
        Инвариантыele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
        ele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
        483. Observation.component:lesionWidth.value[x].value
        Определение

        The value of the measured amount. The value includes an implicit precision in the presentation of the value.

        КороткийNumerical value (with implicit precision)
        Комментарии

        The implicit precision in the value should always be honored. Monetary values have their own rules for handling precision (refer to standard accounting text books).

        Контроль10..1
        Типdecimal
        Модификаторfalse
        Примитивное значениеЭтот примитивный элемент может присутствовать или отсутствовать, или быть замененным расширением
        Summarytrue
        Требования

        Precision is handled implicitly in almost all cases of measurement.

        Мин. значение0
        Инвариантыele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
        ele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
        485. Observation.component:lesionWidth.value[x].comparator
        Определение

        How the value should be understood and represented - whether the actual value is greater or less than the stated value due to measurement issues; e.g. if the comparator is "<" , then the real value is < stated value.

        Короткий< | <= | >= | > | ad - how to understand the value
        Контроль0..1
        ПривязкаКоды ДОЛЖНЫ быть взяты из QuantityComparatorhttp://hl7.org/fhir/ValueSet/quantity-comparator|5.0.0
        (required to http://hl7.org/fhir/ValueSet/quantity-comparator|5.0.0)

        How the Quantity should be understood and represented.

        Типcode
        Модификаторtrue потому что This is labeled as "Is Modifier" because the comparator modifies the interpretation of the value significantly. If there is no comparator, then there is no modification of the value
        Примитивное значениеЭтот примитивный элемент может присутствовать или отсутствовать, или быть замененным расширением
        Summarytrue
        Требования

        Need a framework for handling measures where the value is <5ug/L or >400mg/L due to the limitations of measuring methodology.

        Значение при отсутствииIf there is no comparator, then there is no modification of the value
        Инвариантыele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
        ele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
        487. Observation.component:lesionWidth.value[x].unit
        Определение

        A human-readable form of the unit.

        КороткийUnit representation
        Контроль10..1
        Типstring
        Модификаторfalse
        Примитивное значениеЭтот примитивный элемент может присутствовать или отсутствовать, или быть замененным расширением
        Summarytrue
        Требования

        There are many representations for units of measure and in many contexts, particular representations are fixed and required. I.e. mcg for micrograms.

        Инвариантыele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
        ele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
        489. Observation.component:lesionWidth.value[x].system
        Определение

        The identification of the system that provides the coded form of the unit.

        КороткийSystem that defines coded unit form
        Контроль10..1
        На этот элемент влияют следующие инварианты: qty-3
        Типuri
        Модификаторfalse
        Примитивное значениеЭтот примитивный элемент может присутствовать или отсутствовать, или быть замененным расширением
        Summarytrue
        Требования

        Need to know the system that defines the coded form of the unit.

        Инвариантыele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
        ele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
        491. Observation.component:lesionWidth.value[x].code
        Определение

        A computer processable form of the unit in some unit representation system.

        КороткийCoded form of the unit
        Комментарии

        The preferred system is UCUM, but SNOMED CT can also be used (for customary units) or ISO 4217 for currency. The context of use may additionally require a code from a particular system.

        Контроль10..1
        На этот элемент влияют следующие инварианты: qty-3
        Типcode
        Модификаторfalse
        Примитивное значениеЭтот примитивный элемент может присутствовать или отсутствовать, или быть замененным расширением
        Summarytrue
        Требования

        Need a computable form of the unit that is fixed across all forms. UCUM provides this for quantities, but SNOMED CT provides many units of interest.

        Инвариантыele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
        ele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
        493. Observation.component:lesionThickness
        Название разрезаlesionThickness
        Определение

        Some observations have multiple component observations. These component observations are expressed as separate code value pairs that share the same attributes. Examples include systolic and diastolic component observations for blood pressure measurement and multiple component observations for genetics observations.

        КороткийLesion thicknessComponent results
        Комментарии

        For a discussion on the ways Observations can be assembled in groups together see Notes below.

        Контроль0..1*
        На этот элемент влияют следующие инварианты: obs-7
        ТипBackboneElement
        Модификаторfalse
        Требуется поддержкаtrue
        Summarytrue
        Требования

        Component observations share the same attributes in the Observation resource as the primary observation and are always treated a part of a single observation (they are not separable). However, the reference range for the primary observation value is not inherited by the component values and is required when appropriate for each component observation.

        Инвариантыele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
        ele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
        495. Observation.component:lesionThickness.modifierExtension
        Определение

        May be used to represent additional information that is not part of the basic definition of the element and that modifies the understanding of the element in which it is contained and/or the understanding of the containing element's descendants. Usually modifier elements provide negation or qualification. To make the use of extensions safe and managable, there is a strict set of governance applied to the definition and use of extensions. Though any implementer can define an extension, there is a set of requirements that SHALL be met as part of the definition of the extension. Applications processing a resource are required to check for modifier extensions.

        Modifier extensions SHALL NOT change the meaning of any elements on Resource or DomainResource (including cannot change the meaning of modifierExtension itself).

        КороткийExtensions that cannot be ignored even if unrecognized
        Комментарии

        There can be no stigma associated with the use of extensions by any application, project, or standard - regardless of the institution or jurisdiction that uses or defines the extensions. The use of extensions is what allows the FHIR specification to retain a core level of simplicity for everyone.

        Контроль0..*
        ТипExtension
        Модификаторtrue потому что Modifier extensions are expected to modify the meaning or interpretation of the element that contains them
        Summarytrue
        Требования

        Modifier extensions allow for extensions that cannot be safely ignored to be clearly distinguished from the vast majority of extensions which can be safely ignored. This promotes interoperability by eliminating the need for implementers to prohibit the presence of extensions. For further information, see the definition of modifier extensions.

        Альтернативные именаextensions, user content, modifiers
        Инвариантыele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
        ext-1: Must have either extensions or value[x], not both (extension.exists() != value.exists())
        ele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
        ext-1: Must have either extensions or value[x], not both (extension.exists() != value.exists())
        497. Observation.component:lesionThickness.code
        Определение

        Describes what was observed. Sometimes this is called the observation "code".

        КороткийType of component observation (code / type)
        Комментарии

        All code-value and component.code-component.value pairs need to be taken into account to correctly understand the meaning of the observation.

        Контроль1..1
        На этот элемент влияют следующие инварианты: obs-7
        ПривязкаКоды СЛЕДУЕТ взять из Например, коды см. ObservationCodesVS (0.12.0)http://hl7.org/fhir/ValueSet/observation-codes|5.0.0
        (preferred to https://terminology.dhp.uz/fhir/core/ValueSet/observation-codes-vs|0.12.0)
        ТипCodeableConcept
        Модификаторfalse
        Требуется поддержкаtrue
        Summarytrue
        Требования

        Knowing what kind of observation is being made is essential to understanding the observation.

        Значение шаблона{
          "coding" : [{
            "system" : "https://terminology.dhp.uz/fhir/integrations/CodeSystem/screening-ultrasound-parameter-cs",
            "code" : "scrn-0052-00026"
          }]
        }
        Инвариантыele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
        ele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
        499. Observation.component:lesionThickness.value[x]
        Определение

        The information determined as a result of making the observation, if the information has a simple value.

        КороткийActual component result
        Комментарии

        Used when observation has a set of component observations:

        • An observation may have both a value (e.g. an Apgar score) and component observations (the observations from which the Apgar score was derived).
        • If a value is present, the datatype for this element should be determined by the code.
        • CodeableConcept with just a text would be used instead of a string if the field was usually coded, or if the type associated with the code defines a coded value.
        • Attachment is used if the observation result value is a binary file such as an image. If the observation result value is derived from the binary file (for example 'X' detected and here is the the proof in this image), the binary file may be directly represented using DocumentReference and referenced by derivedFrom.
        • If a value is present, the datatype for this element should be determined by the code.
        • CodeableConcept with just a text would be used instead of a string if the field was usually coded, or if the type associated with the code defines a coded value.
        • Attachment is used if the observation result value is a binary file such as an image. If the observation result value is derived from the binary file (for example 'X' detected and here is the the proof in this image), the binary file may be directly represented using DocumentReference and referenced by derivedFrom.
        • The usage of valueReference is restricted to the MolecularSequence resource when used as a definitional resource, not as a patient-specific finding. .
        • For additional guidance, see the Notes section below.
        Контроль10..1
        ТипQuantity, dateTime, string, Reference(MolecularSequence), Period, Attachment, integer, Range, boolean, SampledData, Ratio, time, CodeableConcept
        [x] ЗаметкаСмотретьВыбор типов данныхдля дополнительной информации о том, как использовать [x]
        Модификаторfalse
        Требуется поддержкаtrue
        Summarytrue
        Требования

        An observation exists to have a value, though it might not if it is in error, or if it represents a group of observations.

        Значение шаблона{
          "unit" : "mm",
          "system" : "http://unitsofmeasure.org",
          "code" : "mm"
        }
        Инвариантыele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
        ele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
        501. Observation.component:lesionThickness.value[x].value
        Определение

        The value of the measured amount. The value includes an implicit precision in the presentation of the value.

        КороткийNumerical value (with implicit precision)
        Комментарии

        The implicit precision in the value should always be honored. Monetary values have their own rules for handling precision (refer to standard accounting text books).

        Контроль10..1
        Типdecimal
        Модификаторfalse
        Примитивное значениеЭтот примитивный элемент может присутствовать или отсутствовать, или быть замененным расширением
        Summarytrue
        Требования

        Precision is handled implicitly in almost all cases of measurement.

        Мин. значение0
        Инвариантыele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
        ele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
        503. Observation.component:lesionThickness.value[x].comparator
        Определение

        How the value should be understood and represented - whether the actual value is greater or less than the stated value due to measurement issues; e.g. if the comparator is "<" , then the real value is < stated value.

        Короткий< | <= | >= | > | ad - how to understand the value
        Контроль0..1
        ПривязкаКоды ДОЛЖНЫ быть взяты из QuantityComparatorhttp://hl7.org/fhir/ValueSet/quantity-comparator|5.0.0
        (required to http://hl7.org/fhir/ValueSet/quantity-comparator|5.0.0)

        How the Quantity should be understood and represented.

        Типcode
        Модификаторtrue потому что This is labeled as "Is Modifier" because the comparator modifies the interpretation of the value significantly. If there is no comparator, then there is no modification of the value
        Примитивное значениеЭтот примитивный элемент может присутствовать или отсутствовать, или быть замененным расширением
        Summarytrue
        Требования

        Need a framework for handling measures where the value is <5ug/L or >400mg/L due to the limitations of measuring methodology.

        Значение при отсутствииIf there is no comparator, then there is no modification of the value
        Инвариантыele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
        ele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
        505. Observation.component:lesionThickness.value[x].unit
        Определение

        A human-readable form of the unit.

        КороткийUnit representation
        Контроль10..1
        Типstring
        Модификаторfalse
        Примитивное значениеЭтот примитивный элемент может присутствовать или отсутствовать, или быть замененным расширением
        Summarytrue
        Требования

        There are many representations for units of measure and in many contexts, particular representations are fixed and required. I.e. mcg for micrograms.

        Инвариантыele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
        ele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
        507. Observation.component:lesionThickness.value[x].system
        Определение

        The identification of the system that provides the coded form of the unit.

        КороткийSystem that defines coded unit form
        Контроль10..1
        На этот элемент влияют следующие инварианты: qty-3
        Типuri
        Модификаторfalse
        Примитивное значениеЭтот примитивный элемент может присутствовать или отсутствовать, или быть замененным расширением
        Summarytrue
        Требования

        Need to know the system that defines the coded form of the unit.

        Инвариантыele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
        ele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
        509. Observation.component:lesionThickness.value[x].code
        Определение

        A computer processable form of the unit in some unit representation system.

        КороткийCoded form of the unit
        Комментарии

        The preferred system is UCUM, but SNOMED CT can also be used (for customary units) or ISO 4217 for currency. The context of use may additionally require a code from a particular system.

        Контроль10..1
        На этот элемент влияют следующие инварианты: qty-3
        Типcode
        Модификаторfalse
        Примитивное значениеЭтот примитивный элемент может присутствовать или отсутствовать, или быть замененным расширением
        Summarytrue
        Требования

        Need a computable form of the unit that is fixed across all forms. UCUM provides this for quantities, but SNOMED CT provides many units of interest.

        Инвариантыele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
        ele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
        511. Observation.component:internalStructureHomogeneous
        Название разрезаinternalStructureHomogeneous
        Определение

        Some observations have multiple component observations. These component observations are expressed as separate code value pairs that share the same attributes. Examples include systolic and diastolic component observations for blood pressure measurement and multiple component observations for genetics observations.

        КороткийComponent results
        Комментарии

        For a discussion on the ways Observations can be assembled in groups together see Notes below.

        Контроль0..1*
        На этот элемент влияют следующие инварианты: obs-7
        ТипBackboneElement
        Модификаторfalse
        Требуется поддержкаtrue
        Summarytrue
        Требования

        Component observations share the same attributes in the Observation resource as the primary observation and are always treated a part of a single observation (they are not separable). However, the reference range for the primary observation value is not inherited by the component values and is required when appropriate for each component observation.

        Инвариантыele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
        ele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
        513. Observation.component:internalStructureHomogeneous.modifierExtension
        Определение

        May be used to represent additional information that is not part of the basic definition of the element and that modifies the understanding of the element in which it is contained and/or the understanding of the containing element's descendants. Usually modifier elements provide negation or qualification. To make the use of extensions safe and managable, there is a strict set of governance applied to the definition and use of extensions. Though any implementer can define an extension, there is a set of requirements that SHALL be met as part of the definition of the extension. Applications processing a resource are required to check for modifier extensions.

        Modifier extensions SHALL NOT change the meaning of any elements on Resource or DomainResource (including cannot change the meaning of modifierExtension itself).

        КороткийExtensions that cannot be ignored even if unrecognized
        Комментарии

        There can be no stigma associated with the use of extensions by any application, project, or standard - regardless of the institution or jurisdiction that uses or defines the extensions. The use of extensions is what allows the FHIR specification to retain a core level of simplicity for everyone.

        Контроль0..*
        ТипExtension
        Модификаторtrue потому что Modifier extensions are expected to modify the meaning or interpretation of the element that contains them
        Summarytrue
        Требования

        Modifier extensions allow for extensions that cannot be safely ignored to be clearly distinguished from the vast majority of extensions which can be safely ignored. This promotes interoperability by eliminating the need for implementers to prohibit the presence of extensions. For further information, see the definition of modifier extensions.

        Альтернативные именаextensions, user content, modifiers
        Инвариантыele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
        ext-1: Must have either extensions or value[x], not both (extension.exists() != value.exists())
        ele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
        ext-1: Must have either extensions or value[x], not both (extension.exists() != value.exists())
        515. Observation.component:internalStructureHomogeneous.code
        Определение

        Describes what was observed. Sometimes this is called the observation "code".

        КороткийType of component observation (code / type)
        Комментарии

        All code-value and component.code-component.value pairs need to be taken into account to correctly understand the meaning of the observation.

        Контроль1..1
        На этот элемент влияют следующие инварианты: obs-7
        ПривязкаКоды СЛЕДУЕТ взять из Например, коды см. ObservationCodesVS (0.12.0)http://hl7.org/fhir/ValueSet/observation-codes|5.0.0
        (preferred to https://terminology.dhp.uz/fhir/core/ValueSet/observation-codes-vs|0.12.0)
        ТипCodeableConcept
        Модификаторfalse
        Требуется поддержкаtrue
        Summarytrue
        Требования

        Knowing what kind of observation is being made is essential to understanding the observation.

        Значение шаблона{
          "coding" : [{
            "system" : "https://terminology.dhp.uz/fhir/integrations/CodeSystem/screening-ultrasound-parameter-cs",
            "code" : "scrn-0052-00031"
          }]
        }
        Инвариантыele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
        ele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
        517. Observation.component:internalStructureHomogeneous.value[x]
        Определение

        The information determined as a result of making the observation, if the information has a simple value.

        КороткийActual component result
        Комментарии

        Used when observation has a set of component observations:

        • An observation may have both a value (e.g. an Apgar score) and component observations (the observations from which the Apgar score was derived).
        • If a value is present, the datatype for this element should be determined by the code.
        • CodeableConcept with just a text would be used instead of a string if the field was usually coded, or if the type associated with the code defines a coded value.
        • Attachment is used if the observation result value is a binary file such as an image. If the observation result value is derived from the binary file (for example 'X' detected and here is the the proof in this image), the binary file may be directly represented using DocumentReference and referenced by derivedFrom.
        • If a value is present, the datatype for this element should be determined by the code.
        • CodeableConcept with just a text would be used instead of a string if the field was usually coded, or if the type associated with the code defines a coded value.
        • Attachment is used if the observation result value is a binary file such as an image. If the observation result value is derived from the binary file (for example 'X' detected and here is the the proof in this image), the binary file may be directly represented using DocumentReference and referenced by derivedFrom.
        • The usage of valueReference is restricted to the MolecularSequence resource when used as a definitional resource, not as a patient-specific finding. .
        • For additional guidance, see the Notes section below.
        Контроль10..1
        Типboolean, dateTime, string, Reference(MolecularSequence), Quantity, Period, Attachment, integer, Range, SampledData, Ratio, time, CodeableConcept
        [x] ЗаметкаСмотретьВыбор типов данныхдля дополнительной информации о том, как использовать [x]
        Модификаторfalse
        Примитивное значениеЭтот примитивный элемент может присутствовать или отсутствовать, или быть замененным расширением
        Требуется поддержкаtrue
        Summarytrue
        Требования

        An observation exists to have a value, though it might not if it is in error, or if it represents a group of observations.

        Инвариантыele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
        ele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
        519. Observation.component:internalStructureHeterogeneous
        Название разрезаinternalStructureHeterogeneous
        Определение

        Some observations have multiple component observations. These component observations are expressed as separate code value pairs that share the same attributes. Examples include systolic and diastolic component observations for blood pressure measurement and multiple component observations for genetics observations.

        КороткийComponent results
        Комментарии

        For a discussion on the ways Observations can be assembled in groups together see Notes below.

        Контроль0..1*
        На этот элемент влияют следующие инварианты: obs-7
        ТипBackboneElement
        Модификаторfalse
        Требуется поддержкаtrue
        Summarytrue
        Требования

        Component observations share the same attributes in the Observation resource as the primary observation and are always treated a part of a single observation (they are not separable). However, the reference range for the primary observation value is not inherited by the component values and is required when appropriate for each component observation.

        Инвариантыele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
        ele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
        521. Observation.component:internalStructureHeterogeneous.modifierExtension
        Определение

        May be used to represent additional information that is not part of the basic definition of the element and that modifies the understanding of the element in which it is contained and/or the understanding of the containing element's descendants. Usually modifier elements provide negation or qualification. To make the use of extensions safe and managable, there is a strict set of governance applied to the definition and use of extensions. Though any implementer can define an extension, there is a set of requirements that SHALL be met as part of the definition of the extension. Applications processing a resource are required to check for modifier extensions.

        Modifier extensions SHALL NOT change the meaning of any elements on Resource or DomainResource (including cannot change the meaning of modifierExtension itself).

        КороткийExtensions that cannot be ignored even if unrecognized
        Комментарии

        There can be no stigma associated with the use of extensions by any application, project, or standard - regardless of the institution or jurisdiction that uses or defines the extensions. The use of extensions is what allows the FHIR specification to retain a core level of simplicity for everyone.

        Контроль0..*
        ТипExtension
        Модификаторtrue потому что Modifier extensions are expected to modify the meaning or interpretation of the element that contains them
        Summarytrue
        Требования

        Modifier extensions allow for extensions that cannot be safely ignored to be clearly distinguished from the vast majority of extensions which can be safely ignored. This promotes interoperability by eliminating the need for implementers to prohibit the presence of extensions. For further information, see the definition of modifier extensions.

        Альтернативные именаextensions, user content, modifiers
        Инвариантыele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
        ext-1: Must have either extensions or value[x], not both (extension.exists() != value.exists())
        ele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
        ext-1: Must have either extensions or value[x], not both (extension.exists() != value.exists())
        523. Observation.component:internalStructureHeterogeneous.code
        Определение

        Describes what was observed. Sometimes this is called the observation "code".

        КороткийType of component observation (code / type)
        Комментарии

        All code-value and component.code-component.value pairs need to be taken into account to correctly understand the meaning of the observation.

        Контроль1..1
        На этот элемент влияют следующие инварианты: obs-7
        ПривязкаКоды СЛЕДУЕТ взять из Например, коды см. ObservationCodesVS (0.12.0)http://hl7.org/fhir/ValueSet/observation-codes|5.0.0
        (preferred to https://terminology.dhp.uz/fhir/core/ValueSet/observation-codes-vs|0.12.0)
        ТипCodeableConcept
        Модификаторfalse
        Требуется поддержкаtrue
        Summarytrue
        Требования

        Knowing what kind of observation is being made is essential to understanding the observation.

        Значение шаблона{
          "coding" : [{
            "system" : "https://terminology.dhp.uz/fhir/integrations/CodeSystem/screening-ultrasound-parameter-cs",
            "code" : "scrn-0052-00032"
          }]
        }
        Инвариантыele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
        ele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
        525. Observation.component:internalStructureHeterogeneous.value[x]
        Определение

        The information determined as a result of making the observation, if the information has a simple value.

        КороткийActual component result
        Комментарии

        Used when observation has a set of component observations:

        • An observation may have both a value (e.g. an Apgar score) and component observations (the observations from which the Apgar score was derived).
        • If a value is present, the datatype for this element should be determined by the code.
        • CodeableConcept with just a text would be used instead of a string if the field was usually coded, or if the type associated with the code defines a coded value.
        • Attachment is used if the observation result value is a binary file such as an image. If the observation result value is derived from the binary file (for example 'X' detected and here is the the proof in this image), the binary file may be directly represented using DocumentReference and referenced by derivedFrom.
        • If a value is present, the datatype for this element should be determined by the code.
        • CodeableConcept with just a text would be used instead of a string if the field was usually coded, or if the type associated with the code defines a coded value.
        • Attachment is used if the observation result value is a binary file such as an image. If the observation result value is derived from the binary file (for example 'X' detected and here is the the proof in this image), the binary file may be directly represented using DocumentReference and referenced by derivedFrom.
        • The usage of valueReference is restricted to the MolecularSequence resource when used as a definitional resource, not as a patient-specific finding. .
        • For additional guidance, see the Notes section below.
        Контроль10..1
        Типboolean, dateTime, string, Reference(MolecularSequence), Quantity, Period, Attachment, integer, Range, SampledData, Ratio, time, CodeableConcept
        [x] ЗаметкаСмотретьВыбор типов данныхдля дополнительной информации о том, как использовать [x]
        Модификаторfalse
        Примитивное значениеЭтот примитивный элемент может присутствовать или отсутствовать, или быть замененным расширением
        Требуется поддержкаtrue
        Summarytrue
        Требования

        An observation exists to have a value, though it might not if it is in error, or if it represents a group of observations.

        Инвариантыele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
        ele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
        527. Observation.component:internalStructureCysticInclusions
        Название разрезаinternalStructureCysticInclusions
        Определение

        Some observations have multiple component observations. These component observations are expressed as separate code value pairs that share the same attributes. Examples include systolic and diastolic component observations for blood pressure measurement and multiple component observations for genetics observations.

        КороткийComponent results
        Комментарии

        For a discussion on the ways Observations can be assembled in groups together see Notes below.

        Контроль0..1*
        На этот элемент влияют следующие инварианты: obs-7
        ТипBackboneElement
        Модификаторfalse
        Требуется поддержкаtrue
        Summarytrue
        Требования

        Component observations share the same attributes in the Observation resource as the primary observation and are always treated a part of a single observation (they are not separable). However, the reference range for the primary observation value is not inherited by the component values and is required when appropriate for each component observation.

        Инвариантыele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
        ele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
        529. Observation.component:internalStructureCysticInclusions.modifierExtension
        Определение

        May be used to represent additional information that is not part of the basic definition of the element and that modifies the understanding of the element in which it is contained and/or the understanding of the containing element's descendants. Usually modifier elements provide negation or qualification. To make the use of extensions safe and managable, there is a strict set of governance applied to the definition and use of extensions. Though any implementer can define an extension, there is a set of requirements that SHALL be met as part of the definition of the extension. Applications processing a resource are required to check for modifier extensions.

        Modifier extensions SHALL NOT change the meaning of any elements on Resource or DomainResource (including cannot change the meaning of modifierExtension itself).

        КороткийExtensions that cannot be ignored even if unrecognized
        Комментарии

        There can be no stigma associated with the use of extensions by any application, project, or standard - regardless of the institution or jurisdiction that uses or defines the extensions. The use of extensions is what allows the FHIR specification to retain a core level of simplicity for everyone.

        Контроль0..*
        ТипExtension
        Модификаторtrue потому что Modifier extensions are expected to modify the meaning or interpretation of the element that contains them
        Summarytrue
        Требования

        Modifier extensions allow for extensions that cannot be safely ignored to be clearly distinguished from the vast majority of extensions which can be safely ignored. This promotes interoperability by eliminating the need for implementers to prohibit the presence of extensions. For further information, see the definition of modifier extensions.

        Альтернативные именаextensions, user content, modifiers
        Инвариантыele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
        ext-1: Must have either extensions or value[x], not both (extension.exists() != value.exists())
        ele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
        ext-1: Must have either extensions or value[x], not both (extension.exists() != value.exists())
        531. Observation.component:internalStructureCysticInclusions.code
        Определение

        Describes what was observed. Sometimes this is called the observation "code".

        КороткийType of component observation (code / type)
        Комментарии

        All code-value and component.code-component.value pairs need to be taken into account to correctly understand the meaning of the observation.

        Контроль1..1
        На этот элемент влияют следующие инварианты: obs-7
        ПривязкаКоды СЛЕДУЕТ взять из Например, коды см. ObservationCodesVS (0.12.0)http://hl7.org/fhir/ValueSet/observation-codes|5.0.0
        (preferred to https://terminology.dhp.uz/fhir/core/ValueSet/observation-codes-vs|0.12.0)
        ТипCodeableConcept
        Модификаторfalse
        Требуется поддержкаtrue
        Summarytrue
        Требования

        Knowing what kind of observation is being made is essential to understanding the observation.

        Значение шаблона{
          "coding" : [{
            "system" : "https://terminology.dhp.uz/fhir/integrations/CodeSystem/screening-ultrasound-parameter-cs",
            "code" : "scrn-0052-00033"
          }]
        }
        Инвариантыele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
        ele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
        533. Observation.component:internalStructureCysticInclusions.value[x]
        Определение

        The information determined as a result of making the observation, if the information has a simple value.

        КороткийActual component result
        Комментарии

        Used when observation has a set of component observations:

        • An observation may have both a value (e.g. an Apgar score) and component observations (the observations from which the Apgar score was derived).
        • If a value is present, the datatype for this element should be determined by the code.
        • CodeableConcept with just a text would be used instead of a string if the field was usually coded, or if the type associated with the code defines a coded value.
        • Attachment is used if the observation result value is a binary file such as an image. If the observation result value is derived from the binary file (for example 'X' detected and here is the the proof in this image), the binary file may be directly represented using DocumentReference and referenced by derivedFrom.
        • If a value is present, the datatype for this element should be determined by the code.
        • CodeableConcept with just a text would be used instead of a string if the field was usually coded, or if the type associated with the code defines a coded value.
        • Attachment is used if the observation result value is a binary file such as an image. If the observation result value is derived from the binary file (for example 'X' detected and here is the the proof in this image), the binary file may be directly represented using DocumentReference and referenced by derivedFrom.
        • The usage of valueReference is restricted to the MolecularSequence resource when used as a definitional resource, not as a patient-specific finding. .
        • For additional guidance, see the Notes section below.
        Контроль10..1
        Типboolean, dateTime, string, Reference(MolecularSequence), Quantity, Period, Attachment, integer, Range, SampledData, Ratio, time, CodeableConcept
        [x] ЗаметкаСмотретьВыбор типов данныхдля дополнительной информации о том, как использовать [x]
        Модификаторfalse
        Примитивное значениеЭтот примитивный элемент может присутствовать или отсутствовать, или быть замененным расширением
        Требуется поддержкаtrue
        Summarytrue
        Требования

        An observation exists to have a value, though it might not if it is in error, or if it represents a group of observations.

        Инвариантыele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
        ele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
        535. Observation.component:internalStructureMicrocalcifications
        Название разрезаinternalStructureMicrocalcifications
        Определение

        Some observations have multiple component observations. These component observations are expressed as separate code value pairs that share the same attributes. Examples include systolic and diastolic component observations for blood pressure measurement and multiple component observations for genetics observations.

        КороткийComponent results
        Комментарии

        For a discussion on the ways Observations can be assembled in groups together see Notes below.

        Контроль0..1*
        На этот элемент влияют следующие инварианты: obs-7
        ТипBackboneElement
        Модификаторfalse
        Требуется поддержкаtrue
        Summarytrue
        Требования

        Component observations share the same attributes in the Observation resource as the primary observation and are always treated a part of a single observation (they are not separable). However, the reference range for the primary observation value is not inherited by the component values and is required when appropriate for each component observation.

        Инвариантыele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
        ele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
        537. Observation.component:internalStructureMicrocalcifications.modifierExtension
        Определение

        May be used to represent additional information that is not part of the basic definition of the element and that modifies the understanding of the element in which it is contained and/or the understanding of the containing element's descendants. Usually modifier elements provide negation or qualification. To make the use of extensions safe and managable, there is a strict set of governance applied to the definition and use of extensions. Though any implementer can define an extension, there is a set of requirements that SHALL be met as part of the definition of the extension. Applications processing a resource are required to check for modifier extensions.

        Modifier extensions SHALL NOT change the meaning of any elements on Resource or DomainResource (including cannot change the meaning of modifierExtension itself).

        КороткийExtensions that cannot be ignored even if unrecognized
        Комментарии

        There can be no stigma associated with the use of extensions by any application, project, or standard - regardless of the institution or jurisdiction that uses or defines the extensions. The use of extensions is what allows the FHIR specification to retain a core level of simplicity for everyone.

        Контроль0..*
        ТипExtension
        Модификаторtrue потому что Modifier extensions are expected to modify the meaning or interpretation of the element that contains them
        Summarytrue
        Требования

        Modifier extensions allow for extensions that cannot be safely ignored to be clearly distinguished from the vast majority of extensions which can be safely ignored. This promotes interoperability by eliminating the need for implementers to prohibit the presence of extensions. For further information, see the definition of modifier extensions.

        Альтернативные именаextensions, user content, modifiers
        Инвариантыele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
        ext-1: Must have either extensions or value[x], not both (extension.exists() != value.exists())
        ele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
        ext-1: Must have either extensions or value[x], not both (extension.exists() != value.exists())
        539. Observation.component:internalStructureMicrocalcifications.code
        Определение

        Describes what was observed. Sometimes this is called the observation "code".

        КороткийType of component observation (code / type)
        Комментарии

        All code-value and component.code-component.value pairs need to be taken into account to correctly understand the meaning of the observation.

        Контроль1..1
        На этот элемент влияют следующие инварианты: obs-7
        ПривязкаКоды СЛЕДУЕТ взять из Например, коды см. ObservationCodesVS (0.12.0)http://hl7.org/fhir/ValueSet/observation-codes|5.0.0
        (preferred to https://terminology.dhp.uz/fhir/core/ValueSet/observation-codes-vs|0.12.0)
        ТипCodeableConcept
        Модификаторfalse
        Требуется поддержкаtrue
        Summarytrue
        Требования

        Knowing what kind of observation is being made is essential to understanding the observation.

        Значение шаблона{
          "coding" : [{
            "system" : "https://terminology.dhp.uz/fhir/integrations/CodeSystem/screening-ultrasound-parameter-cs",
            "code" : "scrn-0052-00034"
          }]
        }
        Инвариантыele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
        ele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
        541. Observation.component:internalStructureMicrocalcifications.value[x]
        Определение

        The information determined as a result of making the observation, if the information has a simple value.

        КороткийActual component result
        Комментарии

        Used when observation has a set of component observations:

        • An observation may have both a value (e.g. an Apgar score) and component observations (the observations from which the Apgar score was derived).
        • If a value is present, the datatype for this element should be determined by the code.
        • CodeableConcept with just a text would be used instead of a string if the field was usually coded, or if the type associated with the code defines a coded value.
        • Attachment is used if the observation result value is a binary file such as an image. If the observation result value is derived from the binary file (for example 'X' detected and here is the the proof in this image), the binary file may be directly represented using DocumentReference and referenced by derivedFrom.
        • If a value is present, the datatype for this element should be determined by the code.
        • CodeableConcept with just a text would be used instead of a string if the field was usually coded, or if the type associated with the code defines a coded value.
        • Attachment is used if the observation result value is a binary file such as an image. If the observation result value is derived from the binary file (for example 'X' detected and here is the the proof in this image), the binary file may be directly represented using DocumentReference and referenced by derivedFrom.
        • The usage of valueReference is restricted to the MolecularSequence resource when used as a definitional resource, not as a patient-specific finding. .
        • For additional guidance, see the Notes section below.
        Контроль10..1
        Типboolean, dateTime, string, Reference(MolecularSequence), Quantity, Period, Attachment, integer, Range, SampledData, Ratio, time, CodeableConcept
        [x] ЗаметкаСмотретьВыбор типов данныхдля дополнительной информации о том, как использовать [x]
        Модификаторfalse
        Примитивное значениеЭтот примитивный элемент может присутствовать или отсутствовать, или быть замененным расширением
        Требуется поддержкаtrue
        Summarytrue
        Требования

        An observation exists to have a value, though it might not if it is in error, or if it represents a group of observations.

        Инвариантыele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
        ele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
        543. Observation.component:internalStructureMacrocalcifications
        Название разрезаinternalStructureMacrocalcifications
        Определение

        Some observations have multiple component observations. These component observations are expressed as separate code value pairs that share the same attributes. Examples include systolic and diastolic component observations for blood pressure measurement and multiple component observations for genetics observations.

        КороткийComponent results
        Комментарии

        For a discussion on the ways Observations can be assembled in groups together see Notes below.

        Контроль0..1*
        На этот элемент влияют следующие инварианты: obs-7
        ТипBackboneElement
        Модификаторfalse
        Требуется поддержкаtrue
        Summarytrue
        Требования

        Component observations share the same attributes in the Observation resource as the primary observation and are always treated a part of a single observation (they are not separable). However, the reference range for the primary observation value is not inherited by the component values and is required when appropriate for each component observation.

        Инвариантыele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
        ele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
        545. Observation.component:internalStructureMacrocalcifications.modifierExtension
        Определение

        May be used to represent additional information that is not part of the basic definition of the element and that modifies the understanding of the element in which it is contained and/or the understanding of the containing element's descendants. Usually modifier elements provide negation or qualification. To make the use of extensions safe and managable, there is a strict set of governance applied to the definition and use of extensions. Though any implementer can define an extension, there is a set of requirements that SHALL be met as part of the definition of the extension. Applications processing a resource are required to check for modifier extensions.

        Modifier extensions SHALL NOT change the meaning of any elements on Resource or DomainResource (including cannot change the meaning of modifierExtension itself).

        КороткийExtensions that cannot be ignored even if unrecognized
        Комментарии

        There can be no stigma associated with the use of extensions by any application, project, or standard - regardless of the institution or jurisdiction that uses or defines the extensions. The use of extensions is what allows the FHIR specification to retain a core level of simplicity for everyone.

        Контроль0..*
        ТипExtension
        Модификаторtrue потому что Modifier extensions are expected to modify the meaning or interpretation of the element that contains them
        Summarytrue
        Требования

        Modifier extensions allow for extensions that cannot be safely ignored to be clearly distinguished from the vast majority of extensions which can be safely ignored. This promotes interoperability by eliminating the need for implementers to prohibit the presence of extensions. For further information, see the definition of modifier extensions.

        Альтернативные именаextensions, user content, modifiers
        Инвариантыele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
        ext-1: Must have either extensions or value[x], not both (extension.exists() != value.exists())
        ele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
        ext-1: Must have either extensions or value[x], not both (extension.exists() != value.exists())
        547. Observation.component:internalStructureMacrocalcifications.code
        Определение

        Describes what was observed. Sometimes this is called the observation "code".

        КороткийType of component observation (code / type)
        Комментарии

        All code-value and component.code-component.value pairs need to be taken into account to correctly understand the meaning of the observation.

        Контроль1..1
        На этот элемент влияют следующие инварианты: obs-7
        ПривязкаКоды СЛЕДУЕТ взять из Например, коды см. ObservationCodesVS (0.12.0)http://hl7.org/fhir/ValueSet/observation-codes|5.0.0
        (preferred to https://terminology.dhp.uz/fhir/core/ValueSet/observation-codes-vs|0.12.0)
        ТипCodeableConcept
        Модификаторfalse
        Требуется поддержкаtrue
        Summarytrue
        Требования

        Knowing what kind of observation is being made is essential to understanding the observation.

        Значение шаблона{
          "coding" : [{
            "system" : "https://terminology.dhp.uz/fhir/integrations/CodeSystem/screening-ultrasound-parameter-cs",
            "code" : "scrn-0052-00035"
          }]
        }
        Инвариантыele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
        ele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
        549. Observation.component:internalStructureMacrocalcifications.value[x]
        Определение

        The information determined as a result of making the observation, if the information has a simple value.

        КороткийActual component result
        Комментарии

        Used when observation has a set of component observations:

        • An observation may have both a value (e.g. an Apgar score) and component observations (the observations from which the Apgar score was derived).
        • If a value is present, the datatype for this element should be determined by the code.
        • CodeableConcept with just a text would be used instead of a string if the field was usually coded, or if the type associated with the code defines a coded value.
        • Attachment is used if the observation result value is a binary file such as an image. If the observation result value is derived from the binary file (for example 'X' detected and here is the the proof in this image), the binary file may be directly represented using DocumentReference and referenced by derivedFrom.
        • If a value is present, the datatype for this element should be determined by the code.
        • CodeableConcept with just a text would be used instead of a string if the field was usually coded, or if the type associated with the code defines a coded value.
        • Attachment is used if the observation result value is a binary file such as an image. If the observation result value is derived from the binary file (for example 'X' detected and here is the the proof in this image), the binary file may be directly represented using DocumentReference and referenced by derivedFrom.
        • The usage of valueReference is restricted to the MolecularSequence resource when used as a definitional resource, not as a patient-specific finding. .
        • For additional guidance, see the Notes section below.
        Контроль10..1
        Типboolean, dateTime, string, Reference(MolecularSequence), Quantity, Period, Attachment, integer, Range, SampledData, Ratio, time, CodeableConcept
        [x] ЗаметкаСмотретьВыбор типов данныхдля дополнительной информации о том, как использовать [x]
        Модификаторfalse
        Примитивное значениеЭтот примитивный элемент может присутствовать или отсутствовать, или быть замененным расширением
        Требуется поддержкаtrue
        Summarytrue
        Требования

        An observation exists to have a value, though it might not if it is in error, or if it represents a group of observations.

        Инвариантыele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
        ele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))

        Рекомендации по толкованию содержимого этой таблицы можно найтиздесь-- no content: do not translate #97 --

        0. Observation
        2. Observation.code
        Значение шаблона{
          "coding" : [{
            "system" : "http://snomed.info/sct",
            "code" : "47079000",
            "display" : "Ultrasonography of breast"
          }]
        }
        4. Observation.value[x]
        ТипCodeableConcept, dateTime, string, Reference(MolecularSequence), Quantity, Period, Attachment, integer, Range, boolean, SampledData, Ratio, time
        [x] ЗаметкаСмотретьВыбор типов данныхдля дополнительной информации о том, как использовать [x]
        6. Observation.bodySite
        КороткийExamined breast side
        Контроль1..?
        ПривязкаКоды ДОЛЖНЫ быть взяты из ScreeningUltrasoundBreastSideVS (0.12.1)
        (required to https://terminology.dhp.uz/fhir/integrations/ValueSet/screening-ultrasound-breast-side-vs|0.12.1)
        8. Observation.component:transformationZone
        Название разрезаtransformationZone
        Контроль0..0
        10. Observation.component:breastDensity
        Название разрезаbreastDensity
        Контроль0..0
        12. Observation.component:imageQuality
        Название разрезаimageQuality
        Контроль0..0
        14. Observation.component:breastFinding
        Название разрезаbreastFinding
        КороткийBreast ultrasound finding
        Контроль0..*
        Требуется поддержкаtrue
        16. Observation.component:breastFinding.code
        Значение шаблона{
          "coding" : [{
            "system" : "https://terminology.dhp.uz/fhir/integrations/CodeSystem/screening-specialized-observation-parameter-cs",
            "code" : "scrn-0073-00004"
          }]
        }
        18. Observation.component:breastFinding.value[x]
        ПривязкаКоды ДОЛЖНЫ быть взяты из ScreeningBreastFindingVS (0.12.1)
        (required to https://terminology.dhp.uz/fhir/integrations/ValueSet/screening-breast-finding-vs|0.12.1)
        ТипCodeableConcept
        [x] ЗаметкаСмотретьВыбор типов данныхдля дополнительной информации о том, как использовать [x]
        20. Observation.component:breastSymmetry
        Название разрезаbreastSymmetry
        КороткийBreast symmetry
        Контроль0..1
        Требуется поддержкаtrue
        22. Observation.component:breastSymmetry.code
        Значение шаблона{
          "coding" : [{
            "system" : "https://terminology.dhp.uz/fhir/integrations/CodeSystem/screening-ultrasound-parameter-cs",
            "code" : "scrn-0052-00004"
          }]
        }
        24. Observation.component:breastSymmetry.value[x]
        ПривязкаКоды ДОЛЖНЫ быть взяты из ScreeningUltrasoundBreastSymmetryVS (0.12.1)
        (required to https://terminology.dhp.uz/fhir/integrations/ValueSet/screening-ultrasound-breast-symmetry-vs|0.12.1)
        ТипCodeableConcept
        [x] ЗаметкаСмотретьВыбор типов данныхдля дополнительной информации о том, как использовать [x]
        26. Observation.component:acrComposition
        Название разрезаacrComposition
        КороткийACR breast composition
        Контроль0..1
        Требуется поддержкаtrue
        28. Observation.component:acrComposition.code
        Значение шаблона{
          "coding" : [{
            "system" : "https://terminology.dhp.uz/fhir/integrations/CodeSystem/screening-ultrasound-parameter-cs",
            "code" : "scrn-0052-00005"
          }]
        }
        30. Observation.component:acrComposition.value[x]
        ПривязкаКоды ДОЛЖНЫ быть взяты из ScreeningUltrasoundAcrCompositionVS (0.12.1)
        (required to https://terminology.dhp.uz/fhir/integrations/ValueSet/screening-ultrasound-acr-composition-vs|0.12.1)
        ТипCodeableConcept
        [x] ЗаметкаСмотретьВыбор типов данныхдля дополнительной информации о том, как использовать [x]
        32. Observation.component:skinNippleStatus
        Название разрезаskinNippleStatus
        КороткийSkin and nipple status
        Контроль0..1
        Требуется поддержкаtrue
        34. Observation.component:skinNippleStatus.code
        Значение шаблона{
          "coding" : [{
            "system" : "https://terminology.dhp.uz/fhir/integrations/CodeSystem/screening-ultrasound-parameter-cs",
            "code" : "scrn-0052-00006"
          }]
        }
        36. Observation.component:skinNippleStatus.value[x]
        ПривязкаКоды ДОЛЖНЫ быть взяты из ScreeningUltrasoundSkinNippleStatusVS (0.12.1)
        (required to https://terminology.dhp.uz/fhir/integrations/ValueSet/screening-ultrasound-skin-nipple-status-vs|0.12.1)
        ТипCodeableConcept
        [x] ЗаметкаСмотретьВыбор типов данныхдля дополнительной информации о том, как использовать [x]
        38. Observation.component:tissueDifferentiation
        Название разрезаtissueDifferentiation
        КороткийTissue differentiation
        Контроль0..1
        Требуется поддержкаtrue
        40. Observation.component:tissueDifferentiation.code
        Значение шаблона{
          "coding" : [{
            "system" : "https://terminology.dhp.uz/fhir/integrations/CodeSystem/screening-ultrasound-parameter-cs",
            "code" : "scrn-0052-00007"
          }]
        }
        42. Observation.component:tissueDifferentiation.value[x]
        ПривязкаКоды ДОЛЖНЫ быть взяты из ScreeningUltrasoundTissueDifferentiationVS (0.12.1)
        (required to https://terminology.dhp.uz/fhir/integrations/ValueSet/screening-ultrasound-tissue-differentiation-vs|0.12.1)
        ТипCodeableConcept
        [x] ЗаметкаСмотретьВыбор типов данныхдля дополнительной информации о том, как использовать [x]
        44. Observation.component:subcutaneousFat
        Название разрезаsubcutaneousFat
        КороткийSubcutaneous fat
        Контроль0..1
        Требуется поддержкаtrue
        46. Observation.component:subcutaneousFat.code
        Значение шаблона{
          "coding" : [{
            "system" : "https://terminology.dhp.uz/fhir/integrations/CodeSystem/screening-ultrasound-parameter-cs",
            "code" : "scrn-0052-00008"
          }]
        }
        48. Observation.component:subcutaneousFat.value[x]
        ПривязкаКоды ДОЛЖНЫ быть взяты из ScreeningUltrasoundSubcutaneousFatVS (0.12.1)
        (required to https://terminology.dhp.uz/fhir/integrations/ValueSet/screening-ultrasound-subcutaneous-fat-vs|0.12.1)
        ТипCodeableConcept
        [x] ЗаметкаСмотретьВыбор типов данныхдля дополнительной информации о том, как использовать [x]
        50. Observation.component:fibroglandularEchogenicity
        Название разрезаfibroglandularEchogenicity
        КороткийFibroglandular echogenicity
        Контроль0..1
        Требуется поддержкаtrue
        52. Observation.component:fibroglandularEchogenicity.code
        Значение шаблона{
          "coding" : [{
            "system" : "https://terminology.dhp.uz/fhir/integrations/CodeSystem/screening-ultrasound-parameter-cs",
            "code" : "scrn-0052-00010"
          }]
        }
        54. Observation.component:fibroglandularEchogenicity.value[x]
        ПривязкаКоды ДОЛЖНЫ быть взяты из ScreeningUltrasoundFibroglandularEchogenicityVS (0.12.1)
        (required to https://terminology.dhp.uz/fhir/integrations/ValueSet/screening-ultrasound-fibroglandular-echogenicity-vs|0.12.1)
        ТипCodeableConcept
        [x] ЗаметкаСмотретьВыбор типов данныхдля дополнительной информации о том, как использовать [x]
        56. Observation.component:ductStatus
        Название разрезаductStatus
        КороткийDuct status
        Контроль0..1
        Требуется поддержкаtrue
        58. Observation.component:ductStatus.code
        Значение шаблона{
          "coding" : [{
            "system" : "https://terminology.dhp.uz/fhir/integrations/CodeSystem/screening-ultrasound-parameter-cs",
            "code" : "scrn-0052-00012"
          }]
        }
        60. Observation.component:ductStatus.value[x]
        ПривязкаКоды ДОЛЖНЫ быть взяты из ScreeningUltrasoundDuctStatusVS (0.12.1)
        (required to https://terminology.dhp.uz/fhir/integrations/ValueSet/screening-ultrasound-duct-status-vs|0.12.1)
        ТипCodeableConcept
        [x] ЗаметкаСмотретьВыбор типов данныхдля дополнительной информации о том, как использовать [x]
        62. Observation.component:retromammarySpace
        Название разрезаretromammarySpace
        КороткийRetromammary space
        Контроль0..1
        Требуется поддержкаtrue
        64. Observation.component:retromammarySpace.code
        Значение шаблона{
          "coding" : [{
            "system" : "https://terminology.dhp.uz/fhir/integrations/CodeSystem/screening-ultrasound-parameter-cs",
            "code" : "scrn-0052-00013"
          }]
        }
        66. Observation.component:retromammarySpace.value[x]
        ПривязкаКоды ДОЛЖНЫ быть взяты из ScreeningUltrasoundRetromammarySpaceVS (0.12.1)
        (required to https://terminology.dhp.uz/fhir/integrations/ValueSet/screening-ultrasound-retromammary-space-vs|0.12.1)
        ТипCodeableConcept
        [x] ЗаметкаСмотретьВыбор типов данныхдля дополнительной информации о том, как использовать [x]
        68. Observation.component:elastographyColorType
        Название разрезаelastographyColorType
        КороткийElastography color type
        Контроль0..1
        Требуется поддержкаtrue
        70. Observation.component:elastographyColorType.code
        Значение шаблона{
          "coding" : [{
            "system" : "https://terminology.dhp.uz/fhir/integrations/CodeSystem/screening-ultrasound-parameter-cs",
            "code" : "scrn-0052-00015"
          }]
        }
        72. Observation.component:elastographyColorType.value[x]
        ПривязкаКоды ДОЛЖНЫ быть взяты из ScreeningUltrasoundElastographyColorTypeVS (0.12.1)
        (required to https://terminology.dhp.uz/fhir/integrations/ValueSet/screening-ultrasound-elastography-color-type-vs|0.12.1)
        ТипCodeableConcept
        [x] ЗаметкаСмотретьВыбор типов данныхдля дополнительной информации о том, как использовать [x]
        74. Observation.component:intramammaryNodeStatus
        Название разрезаintramammaryNodeStatus
        КороткийIntramammary lymph node status
        Контроль0..1
        Требуется поддержкаtrue
        76. Observation.component:intramammaryNodeStatus.code
        Значение шаблона{
          "coding" : [{
            "system" : "https://terminology.dhp.uz/fhir/integrations/CodeSystem/screening-ultrasound-parameter-cs",
            "code" : "scrn-0052-00016"
          }]
        }
        78. Observation.component:intramammaryNodeStatus.value[x]
        ПривязкаКоды ДОЛЖНЫ быть взяты из ScreeningUltrasoundIntramammaryNodeStatusVS (0.12.1)
        (required to https://terminology.dhp.uz/fhir/integrations/ValueSet/screening-ultrasound-intramammary-node-status-vs|0.12.1)
        ТипCodeableConcept
        [x] ЗаметкаСмотретьВыбор типов данныхдля дополнительной информации о том, как использовать [x]
        80. Observation.component:axillaryNodeStatus
        Название разрезаaxillaryNodeStatus
        КороткийAxillary lymph node status
        Контроль0..1
        Требуется поддержкаtrue
        82. Observation.component:axillaryNodeStatus.code
        Значение шаблона{
          "coding" : [{
            "system" : "https://terminology.dhp.uz/fhir/integrations/CodeSystem/screening-ultrasound-parameter-cs",
            "code" : "scrn-0052-00017"
          }]
        }
        84. Observation.component:axillaryNodeStatus.value[x]
        ПривязкаКоды ДОЛЖНЫ быть взяты из ScreeningUltrasoundAxillaryNodeStatusVS (0.12.1)
        (required to https://terminology.dhp.uz/fhir/integrations/ValueSet/screening-ultrasound-axillary-node-status-vs|0.12.1)
        ТипCodeableConcept
        [x] ЗаметкаСмотретьВыбор типов данныхдля дополнительной информации о том, как использовать [x]
        86. Observation.component:axillaryNodeDifferentiation
        Название разрезаaxillaryNodeDifferentiation
        КороткийAxillary lymph node differentiation
        Контроль0..1
        Требуется поддержкаtrue
        88. Observation.component:axillaryNodeDifferentiation.code
        Значение шаблона{
          "coding" : [{
            "system" : "https://terminology.dhp.uz/fhir/integrations/CodeSystem/screening-specialized-observation-parameter-cs",
            "code" : "scrn-0073-00016"
          }]
        }
        90. Observation.component:axillaryNodeDifferentiation.value[x]
        ПривязкаКоды ДОЛЖНЫ быть взяты из ScreeningUltrasoundAxillaryNodeDifferentiationVS (0.12.1)
        (required to https://terminology.dhp.uz/fhir/integrations/ValueSet/screening-ultrasound-axillary-node-differentiation-vs|0.12.1)
        ТипCodeableConcept
        [x] ЗаметкаСмотретьВыбор типов данныхдля дополнительной информации о том, как использовать [x]
        92. Observation.component:regionalNodeStatus
        Название разрезаregionalNodeStatus
        КороткийRegional lymph node status
        Контроль0..1
        Требуется поддержкаtrue
        94. Observation.component:regionalNodeStatus.code
        Значение шаблона{
          "coding" : [{
            "system" : "https://terminology.dhp.uz/fhir/integrations/CodeSystem/screening-ultrasound-parameter-cs",
            "code" : "scrn-0052-00018"
          }]
        }
        96. Observation.component:regionalNodeStatus.value[x]
        ПривязкаКоды ДОЛЖНЫ быть взяты из ScreeningUltrasoundRegionalNodeStatusVS (0.12.1)
        (required to https://terminology.dhp.uz/fhir/integrations/ValueSet/screening-ultrasound-regional-node-status-vs|0.12.1)
        ТипCodeableConcept
        [x] ЗаметкаСмотретьВыбор типов данныхдля дополнительной информации о том, как использовать [x]
        98. Observation.component:dynamics
        Название разрезаdynamics
        КороткийComparison with previous study
        Контроль0..1
        Требуется поддержкаtrue
        100. Observation.component:dynamics.code
        Значение шаблона{
          "coding" : [{
            "system" : "https://terminology.dhp.uz/fhir/integrations/CodeSystem/screening-ultrasound-parameter-cs",
            "code" : "scrn-0052-00020"
          }]
        }
        102. Observation.component:dynamics.value[x]
        ПривязкаКоды ДОЛЖНЫ быть взяты из ScreeningUltrasoundDynamicsVS (0.12.1)
        (required to https://terminology.dhp.uz/fhir/integrations/ValueSet/screening-ultrasound-dynamics-vs|0.12.1)
        ТипCodeableConcept
        [x] ЗаметкаСмотретьВыбор типов данныхдля дополнительной информации о том, как использовать [x]
        104. Observation.component:breastQuadrant
        Название разрезаbreastQuadrant
        КороткийBreast quadrant
        Контроль0..1
        Требуется поддержкаtrue
        106. Observation.component:breastQuadrant.code
        Значение шаблона{
          "coding" : [{
            "system" : "https://terminology.dhp.uz/fhir/integrations/CodeSystem/screening-specialized-observation-parameter-cs",
            "code" : "scrn-0073-00015"
          }]
        }
        108. Observation.component:breastQuadrant.value[x]
        ПривязкаКоды ДОЛЖНЫ быть взяты из ScreeningUltrasoundBreastQuadrantVS (0.12.1)
        (required to https://terminology.dhp.uz/fhir/integrations/ValueSet/screening-ultrasound-breast-quadrant-vs|0.12.1)
        ТипCodeableConcept
        [x] ЗаметкаСмотретьВыбор типов данныхдля дополнительной информации о том, как использовать [x]
        110. Observation.component:lesionShape
        Название разрезаlesionShape
        КороткийLesion shape
        Контроль0..1
        Требуется поддержкаtrue
        112. Observation.component:lesionShape.code
        Значение шаблона{
          "coding" : [{
            "system" : "https://terminology.dhp.uz/fhir/integrations/CodeSystem/screening-ultrasound-parameter-cs",
            "code" : "scrn-0052-00027"
          }]
        }
        114. Observation.component:lesionShape.value[x]
        ПривязкаКоды ДОЛЖНЫ быть взяты из ScreeningUltrasoundLesionShapeVS (0.12.1)
        (required to https://terminology.dhp.uz/fhir/integrations/ValueSet/screening-ultrasound-lesion-shape-vs|0.12.1)
        ТипCodeableConcept
        [x] ЗаметкаСмотретьВыбор типов данныхдля дополнительной информации о том, как использовать [x]
        116. Observation.component:lesionOrientation
        Название разрезаlesionOrientation
        КороткийLesion orientation
        Контроль0..1
        Требуется поддержкаtrue
        118. Observation.component:lesionOrientation.code
        Значение шаблона{
          "coding" : [{
            "system" : "https://terminology.dhp.uz/fhir/integrations/CodeSystem/screening-ultrasound-parameter-cs",
            "code" : "scrn-0052-00028"
          }]
        }
        120. Observation.component:lesionOrientation.value[x]
        ПривязкаКоды ДОЛЖНЫ быть взяты из ScreeningUltrasoundLesionOrientationVS (0.12.1)
        (required to https://terminology.dhp.uz/fhir/integrations/ValueSet/screening-ultrasound-lesion-orientation-vs|0.12.1)
        ТипCodeableConcept
        [x] ЗаметкаСмотретьВыбор типов данныхдля дополнительной информации о том, как использовать [x]
        122. Observation.component:lesionContour
        Название разрезаlesionContour
        КороткийLesion contour
        Контроль0..1
        Требуется поддержкаtrue
        124. Observation.component:lesionContour.code
        Значение шаблона{
          "coding" : [{
            "system" : "https://terminology.dhp.uz/fhir/integrations/CodeSystem/screening-ultrasound-parameter-cs",
            "code" : "scrn-0052-00029"
          }]
        }
        126. Observation.component:lesionContour.value[x]
        ПривязкаКоды ДОЛЖНЫ быть взяты из ScreeningUltrasoundLesionContourVS (0.12.1)
        (required to https://terminology.dhp.uz/fhir/integrations/ValueSet/screening-ultrasound-lesion-contour-vs|0.12.1)
        ТипCodeableConcept
        [x] ЗаметкаСмотретьВыбор типов данныхдля дополнительной информации о том, как использовать [x]
        128. Observation.component:lesionEchogenicity
        Название разрезаlesionEchogenicity
        КороткийLesion echogenicity
        Контроль0..1
        Требуется поддержкаtrue
        130. Observation.component:lesionEchogenicity.code
        Значение шаблона{
          "coding" : [{
            "system" : "https://terminology.dhp.uz/fhir/integrations/CodeSystem/screening-ultrasound-parameter-cs",
            "code" : "scrn-0052-00030"
          }]
        }
        132. Observation.component:lesionEchogenicity.value[x]
        ПривязкаКоды ДОЛЖНЫ быть взяты из ScreeningUltrasoundLesionEchogenicityVS (0.12.1)
        (required to https://terminology.dhp.uz/fhir/integrations/ValueSet/screening-ultrasound-lesion-echogenicity-vs|0.12.1)
        ТипCodeableConcept
        [x] ЗаметкаСмотретьВыбор типов данныхдля дополнительной информации о том, как использовать [x]
        134. Observation.component:lesionAcousticEffect
        Название разрезаlesionAcousticEffect
        КороткийLesion acoustic effect
        Контроль0..1
        Требуется поддержкаtrue
        136. Observation.component:lesionAcousticEffect.code
        Значение шаблона{
          "coding" : [{
            "system" : "https://terminology.dhp.uz/fhir/integrations/CodeSystem/screening-ultrasound-parameter-cs",
            "code" : "scrn-0052-00036"
          }]
        }
        138. Observation.component:lesionAcousticEffect.value[x]
        ПривязкаКоды ДОЛЖНЫ быть взяты из ScreeningUltrasoundLesionAcousticEffectVS (0.12.1)
        (required to https://terminology.dhp.uz/fhir/integrations/ValueSet/screening-ultrasound-lesion-acoustic-effect-vs|0.12.1)
        ТипCodeableConcept
        [x] ЗаметкаСмотретьВыбор типов данныхдля дополнительной информации о том, как использовать [x]
        140. Observation.component:lesionVascularization
        Название разрезаlesionVascularization
        КороткийLesion vascularization
        Контроль0..1
        Требуется поддержкаtrue
        142. Observation.component:lesionVascularization.code
        Значение шаблона{
          "coding" : [{
            "system" : "https://terminology.dhp.uz/fhir/integrations/CodeSystem/screening-ultrasound-parameter-cs",
            "code" : "scrn-0052-00037"
          }]
        }
        144. Observation.component:lesionVascularization.value[x]
        ПривязкаКоды ДОЛЖНЫ быть взяты из ScreeningUltrasoundLesionVascularizationVS (0.12.1)
        (required to https://terminology.dhp.uz/fhir/integrations/ValueSet/screening-ultrasound-lesion-vascularization-vs|0.12.1)
        ТипCodeableConcept
        [x] ЗаметкаСмотретьВыбор типов данныхдля дополнительной информации о том, как использовать [x]
        146. Observation.component:menstrualCycleDuration
        Название разрезаmenstrualCycleDuration
        КороткийMenstrual cycle duration
        Контроль0..1
        Требуется поддержкаtrue
        148. Observation.component:menstrualCycleDuration.code
        Значение шаблона{
          "coding" : [{
            "system" : "https://terminology.dhp.uz/fhir/integrations/CodeSystem/screening-ultrasound-parameter-cs",
            "code" : "scrn-0052-00001"
          }]
        }
        150. Observation.component:menstrualCycleDuration.value[x]
        Контроль1..?
        ТипQuantity
        [x] ЗаметкаСмотретьВыбор типов данныхдля дополнительной информации о том, как использовать [x]
        Значение шаблона{
          "unit" : "d",
          "system" : "http://unitsofmeasure.org",
          "code" : "d"
        }
        152. Observation.component:menstrualCycleDuration.value[x].value
        Контроль1..?
        Мин. значение0
        154. Observation.component:menstrualCycleDuration.value[x].unit
        Контроль1..?
        156. Observation.component:menstrualCycleDuration.value[x].system
        Контроль1..?
        158. Observation.component:menstrualCycleDuration.value[x].code
        Контроль1..?
        160. Observation.component:anamnesis
        Название разрезаanamnesis
        КороткийUltrasound anamnesis
        Контроль0..1
        Требуется поддержкаtrue
        162. Observation.component:anamnesis.code
        Значение шаблона{
          "coding" : [{
            "system" : "https://terminology.dhp.uz/fhir/integrations/CodeSystem/screening-ultrasound-parameter-cs",
            "code" : "scrn-0052-00003"
          }]
        }
        164. Observation.component:anamnesis.value[x]
        Контроль1..?
        Типstring
        [x] ЗаметкаСмотретьВыбор типов данныхдля дополнительной информации о том, как использовать [x]
        Примитивное значениеЭтот примитивный элемент может присутствовать или отсутствовать, или быть замененным расширением
        166. Observation.component:fibroglandularThickness
        Название разрезаfibroglandularThickness
        КороткийFibroglandular complex thickness
        Контроль0..1
        Требуется поддержкаtrue
        168. Observation.component:fibroglandularThickness.code
        Значение шаблона{
          "coding" : [{
            "system" : "https://terminology.dhp.uz/fhir/integrations/CodeSystem/screening-ultrasound-parameter-cs",
            "code" : "scrn-0052-00009"
          }]
        }
        170. Observation.component:fibroglandularThickness.value[x]
        Контроль1..?
        ТипQuantity
        [x] ЗаметкаСмотретьВыбор типов данныхдля дополнительной информации о том, как использовать [x]
        Значение шаблона{
          "unit" : "mm",
          "system" : "http://unitsofmeasure.org",
          "code" : "mm"
        }
        172. Observation.component:fibroglandularThickness.value[x].value
        Контроль1..?
        Мин. значение0
        174. Observation.component:fibroglandularThickness.value[x].unit
        Контроль1..?
        176. Observation.component:fibroglandularThickness.value[x].system
        Контроль1..?
        178. Observation.component:fibroglandularThickness.value[x].code
        Контроль1..?
        180. Observation.component:maximumDuctDiameter
        Название разрезаmaximumDuctDiameter
        КороткийMaximum duct diameter
        Контроль0..1
        Требуется поддержкаtrue
        182. Observation.component:maximumDuctDiameter.code
        Значение шаблона{
          "coding" : [{
            "system" : "https://terminology.dhp.uz/fhir/integrations/CodeSystem/screening-ultrasound-parameter-cs",
            "code" : "scrn-0052-00011"
          }]
        }
        184. Observation.component:maximumDuctDiameter.value[x]
        Контроль1..?
        ТипQuantity
        [x] ЗаметкаСмотретьВыбор типов данныхдля дополнительной информации о том, как использовать [x]
        Значение шаблона{
          "unit" : "mm",
          "system" : "http://unitsofmeasure.org",
          "code" : "mm"
        }
        186. Observation.component:maximumDuctDiameter.value[x].value
        Контроль1..?
        Мин. значение0
        188. Observation.component:maximumDuctDiameter.value[x].unit
        Контроль1..?
        190. Observation.component:maximumDuctDiameter.value[x].system
        Контроль1..?
        192. Observation.component:maximumDuctDiameter.value[x].code
        Контроль1..?
        194. Observation.component:elastographyStiffness
        Название разрезаelastographyStiffness
        КороткийElastography stiffness; unit is supplied by Screening
        Контроль0..1
        Требуется поддержкаtrue
        196. Observation.component:elastographyStiffness.code
        Значение шаблона{
          "coding" : [{
            "system" : "https://terminology.dhp.uz/fhir/integrations/CodeSystem/screening-ultrasound-parameter-cs",
            "code" : "scrn-0052-00014"
          }]
        }
        198. Observation.component:elastographyStiffness.value[x]
        Контроль1..?
        ТипQuantity
        [x] ЗаметкаСмотретьВыбор типов данныхдля дополнительной информации о том, как использовать [x]
        Значение шаблона{
          "system" : "http://unitsofmeasure.org"
        }
        200. Observation.component:elastographyStiffness.value[x].value
        Контроль1..?
        Мин. значение0
        202. Observation.component:elastographyStiffness.value[x].unit
        Контроль1..?
        204. Observation.component:elastographyStiffness.value[x].system
        Контроль1..?
        206. Observation.component:elastographyStiffness.value[x].code
        Контроль1..?
        208. Observation.component:axillaryMaximumNodeSize
        Название разрезаaxillaryMaximumNodeSize
        КороткийMaximum axillary lymph node size
        Контроль0..1
        Требуется поддержкаtrue
        210. Observation.component:axillaryMaximumNodeSize.code
        Значение шаблона{
          "coding" : [{
            "system" : "https://terminology.dhp.uz/fhir/integrations/CodeSystem/screening-ultrasound-parameter-cs",
            "code" : "scrn-0052-00038"
          }]
        }
        212. Observation.component:axillaryMaximumNodeSize.value[x]
        Контроль1..?
        ТипQuantity
        [x] ЗаметкаСмотретьВыбор типов данныхдля дополнительной информации о том, как использовать [x]
        Значение шаблона{
          "unit" : "mm",
          "system" : "http://unitsofmeasure.org",
          "code" : "mm"
        }
        214. Observation.component:axillaryMaximumNodeSize.value[x].value
        Контроль1..?
        Мин. значение0
        216. Observation.component:axillaryMaximumNodeSize.value[x].unit
        Контроль1..?
        218. Observation.component:axillaryMaximumNodeSize.value[x].system
        Контроль1..?
        220. Observation.component:axillaryMaximumNodeSize.value[x].code
        Контроль1..?
        222. Observation.component:axillaryCorticalThickness
        Название разрезаaxillaryCorticalThickness
        КороткийAxillary lymph node cortical thickness
        Контроль0..1
        Требуется поддержкаtrue
        224. Observation.component:axillaryCorticalThickness.code
        Значение шаблона{
          "coding" : [{
            "system" : "https://terminology.dhp.uz/fhir/integrations/CodeSystem/screening-ultrasound-parameter-cs",
            "code" : "scrn-0052-00039"
          }]
        }
        226. Observation.component:axillaryCorticalThickness.value[x]
        Контроль1..?
        ТипQuantity
        [x] ЗаметкаСмотретьВыбор типов данныхдля дополнительной информации о том, как использовать [x]
        Значение шаблона{
          "unit" : "mm",
          "system" : "http://unitsofmeasure.org",
          "code" : "mm"
        }
        228. Observation.component:axillaryCorticalThickness.value[x].value
        Контроль1..?
        Мин. значение0
        230. Observation.component:axillaryCorticalThickness.value[x].unit
        Контроль1..?
        232. Observation.component:axillaryCorticalThickness.value[x].system
        Контроль1..?
        234. Observation.component:axillaryCorticalThickness.value[x].code
        Контроль1..?
        236. Observation.component:regionalNodeNote
        Название разрезаregionalNodeNote
        КороткийComment about other regional lymph nodes
        Контроль0..1
        Требуется поддержкаtrue
        238. Observation.component:regionalNodeNote.code
        Значение шаблона{
          "coding" : [{
            "system" : "https://terminology.dhp.uz/fhir/integrations/CodeSystem/screening-ultrasound-parameter-cs",
            "code" : "scrn-0052-00040"
          }]
        }
        240. Observation.component:regionalNodeNote.value[x]
        Контроль1..?
        Типstring
        [x] ЗаметкаСмотретьВыбор типов данныхдля дополнительной информации о том, как использовать [x]
        Примитивное значениеЭтот примитивный элемент может присутствовать или отсутствовать, или быть замененным расширением
        242. Observation.component:additionalChanges
        Название разрезаadditionalChanges
        КороткийAdditional ultrasound changes
        Контроль0..1
        Требуется поддержкаtrue
        244. Observation.component:additionalChanges.code
        Значение шаблона{
          "coding" : [{
            "system" : "https://terminology.dhp.uz/fhir/integrations/CodeSystem/screening-ultrasound-parameter-cs",
            "code" : "scrn-0052-00019"
          }]
        }
        246. Observation.component:additionalChanges.value[x]
        Контроль1..?
        Типstring
        [x] ЗаметкаСмотретьВыбор типов данныхдля дополнительной информации о том, как использовать [x]
        Примитивное значениеЭтот примитивный элемент может присутствовать или отсутствовать, или быть замененным расширением
        248. Observation.component:focalLesionPresent
        Название разрезаfocalLesionPresent
        КороткийFocal breast lesion present
        Контроль0..1
        Требуется поддержкаtrue
        250. Observation.component:focalLesionPresent.code
        Значение шаблона{
          "coding" : [{
            "system" : "https://terminology.dhp.uz/fhir/integrations/CodeSystem/screening-ultrasound-parameter-cs",
            "code" : "scrn-0052-00021"
          }]
        }
        252. Observation.component:focalLesionPresent.value[x]
        Контроль1..?
        Типboolean
        [x] ЗаметкаСмотретьВыбор типов данныхдля дополнительной информации о том, как использовать [x]
        Примитивное значениеЭтот примитивный элемент может присутствовать или отсутствовать, или быть замененным расширением
        254. Observation.component:clockFacePosition
        Название разрезаclockFacePosition
        КороткийLesion clock-face position, 1 to 12
        Контроль0..1
        Требуется поддержкаtrue
        256. Observation.component:clockFacePosition.code
        Значение шаблона{
          "coding" : [{
            "system" : "https://terminology.dhp.uz/fhir/integrations/CodeSystem/screening-ultrasound-parameter-cs",
            "code" : "scrn-0052-00022"
          }]
        }
        258. Observation.component:clockFacePosition.value[x]
        Контроль1..?
        Типinteger
        [x] ЗаметкаСмотретьВыбор типов данныхдля дополнительной информации о том, как использовать [x]
        Примитивное значениеЭтот примитивный элемент может присутствовать или отсутствовать, или быть замененным расширением
        Мин. значение1
        Максимальное значение12
        260. Observation.component:distanceFromNipple
        Название разрезаdistanceFromNipple
        КороткийDistance from nipple
        Контроль0..1
        Требуется поддержкаtrue
        262. Observation.component:distanceFromNipple.code
        Значение шаблона{
          "coding" : [{
            "system" : "https://terminology.dhp.uz/fhir/integrations/CodeSystem/screening-ultrasound-parameter-cs",
            "code" : "scrn-0052-00023"
          }]
        }
        264. Observation.component:distanceFromNipple.value[x]
        Контроль1..?
        ТипQuantity
        [x] ЗаметкаСмотретьВыбор типов данныхдля дополнительной информации о том, как использовать [x]
        Значение шаблона{
          "unit" : "mm",
          "system" : "http://unitsofmeasure.org",
          "code" : "mm"
        }
        266. Observation.component:distanceFromNipple.value[x].value
        Контроль1..?
        Мин. значение0
        268. Observation.component:distanceFromNipple.value[x].unit
        Контроль1..?
        270. Observation.component:distanceFromNipple.value[x].system
        Контроль1..?
        272. Observation.component:distanceFromNipple.value[x].code
        Контроль1..?
        274. Observation.component:lesionLength
        Название разрезаlesionLength
        КороткийLesion length
        Контроль0..1
        Требуется поддержкаtrue
        276. Observation.component:lesionLength.code
        Значение шаблона{
          "coding" : [{
            "system" : "https://terminology.dhp.uz/fhir/integrations/CodeSystem/screening-ultrasound-parameter-cs",
            "code" : "scrn-0052-00024"
          }]
        }
        278. Observation.component:lesionLength.value[x]
        Контроль1..?
        ТипQuantity
        [x] ЗаметкаСмотретьВыбор типов данныхдля дополнительной информации о том, как использовать [x]
        Значение шаблона{
          "unit" : "mm",
          "system" : "http://unitsofmeasure.org",
          "code" : "mm"
        }
        280. Observation.component:lesionLength.value[x].value
        Контроль1..?
        Мин. значение0
        282. Observation.component:lesionLength.value[x].unit
        Контроль1..?
        284. Observation.component:lesionLength.value[x].system
        Контроль1..?
        286. Observation.component:lesionLength.value[x].code
        Контроль1..?
        288. Observation.component:lesionWidth
        Название разрезаlesionWidth
        КороткийLesion width
        Контроль0..1
        Требуется поддержкаtrue
        290. Observation.component:lesionWidth.code
        Значение шаблона{
          "coding" : [{
            "system" : "https://terminology.dhp.uz/fhir/integrations/CodeSystem/screening-ultrasound-parameter-cs",
            "code" : "scrn-0052-00025"
          }]
        }
        292. Observation.component:lesionWidth.value[x]
        Контроль1..?
        ТипQuantity
        [x] ЗаметкаСмотретьВыбор типов данныхдля дополнительной информации о том, как использовать [x]
        Значение шаблона{
          "unit" : "mm",
          "system" : "http://unitsofmeasure.org",
          "code" : "mm"
        }
        294. Observation.component:lesionWidth.value[x].value
        Контроль1..?
        Мин. значение0
        296. Observation.component:lesionWidth.value[x].unit
        Контроль1..?
        298. Observation.component:lesionWidth.value[x].system
        Контроль1..?
        300. Observation.component:lesionWidth.value[x].code
        Контроль1..?
        302. Observation.component:lesionThickness
        Название разрезаlesionThickness
        КороткийLesion thickness
        Контроль0..1
        Требуется поддержкаtrue
        304. Observation.component:lesionThickness.code
        Значение шаблона{
          "coding" : [{
            "system" : "https://terminology.dhp.uz/fhir/integrations/CodeSystem/screening-ultrasound-parameter-cs",
            "code" : "scrn-0052-00026"
          }]
        }
        306. Observation.component:lesionThickness.value[x]
        Контроль1..?
        ТипQuantity
        [x] ЗаметкаСмотретьВыбор типов данныхдля дополнительной информации о том, как использовать [x]
        Значение шаблона{
          "unit" : "mm",
          "system" : "http://unitsofmeasure.org",
          "code" : "mm"
        }
        308. Observation.component:lesionThickness.value[x].value
        Контроль1..?
        Мин. значение0
        310. Observation.component:lesionThickness.value[x].unit
        Контроль1..?
        312. Observation.component:lesionThickness.value[x].system
        Контроль1..?
        314. Observation.component:lesionThickness.value[x].code
        Контроль1..?
        316. Observation.component:internalStructureHomogeneous
        Название разрезаinternalStructureHomogeneous
        Контроль0..1
        Требуется поддержкаtrue
        318. Observation.component:internalStructureHomogeneous.code
        Значение шаблона{
          "coding" : [{
            "system" : "https://terminology.dhp.uz/fhir/integrations/CodeSystem/screening-ultrasound-parameter-cs",
            "code" : "scrn-0052-00031"
          }]
        }
        320. Observation.component:internalStructureHomogeneous.value[x]
        Контроль1..?
        Типboolean
        [x] ЗаметкаСмотретьВыбор типов данныхдля дополнительной информации о том, как использовать [x]
        Примитивное значениеЭтот примитивный элемент может присутствовать или отсутствовать, или быть замененным расширением
        322. Observation.component:internalStructureHeterogeneous
        Название разрезаinternalStructureHeterogeneous
        Контроль0..1
        Требуется поддержкаtrue
        324. Observation.component:internalStructureHeterogeneous.code
        Значение шаблона{
          "coding" : [{
            "system" : "https://terminology.dhp.uz/fhir/integrations/CodeSystem/screening-ultrasound-parameter-cs",
            "code" : "scrn-0052-00032"
          }]
        }
        326. Observation.component:internalStructureHeterogeneous.value[x]
        Контроль1..?
        Типboolean
        [x] ЗаметкаСмотретьВыбор типов данныхдля дополнительной информации о том, как использовать [x]
        Примитивное значениеЭтот примитивный элемент может присутствовать или отсутствовать, или быть замененным расширением
        328. Observation.component:internalStructureCysticInclusions
        Название разрезаinternalStructureCysticInclusions
        Контроль0..1
        Требуется поддержкаtrue
        330. Observation.component:internalStructureCysticInclusions.code
        Значение шаблона{
          "coding" : [{
            "system" : "https://terminology.dhp.uz/fhir/integrations/CodeSystem/screening-ultrasound-parameter-cs",
            "code" : "scrn-0052-00033"
          }]
        }
        332. Observation.component:internalStructureCysticInclusions.value[x]
        Контроль1..?
        Типboolean
        [x] ЗаметкаСмотретьВыбор типов данныхдля дополнительной информации о том, как использовать [x]
        Примитивное значениеЭтот примитивный элемент может присутствовать или отсутствовать, или быть замененным расширением
        334. Observation.component:internalStructureMicrocalcifications
        Название разрезаinternalStructureMicrocalcifications
        Контроль0..1
        Требуется поддержкаtrue
        336. Observation.component:internalStructureMicrocalcifications.code
        Значение шаблона{
          "coding" : [{
            "system" : "https://terminology.dhp.uz/fhir/integrations/CodeSystem/screening-ultrasound-parameter-cs",
            "code" : "scrn-0052-00034"
          }]
        }
        338. Observation.component:internalStructureMicrocalcifications.value[x]
        Контроль1..?
        Типboolean
        [x] ЗаметкаСмотретьВыбор типов данныхдля дополнительной информации о том, как использовать [x]
        Примитивное значениеЭтот примитивный элемент может присутствовать или отсутствовать, или быть замененным расширением
        340. Observation.component:internalStructureMacrocalcifications
        Название разрезаinternalStructureMacrocalcifications
        Контроль0..1
        Требуется поддержкаtrue
        342. Observation.component:internalStructureMacrocalcifications.code
        Значение шаблона{
          "coding" : [{
            "system" : "https://terminology.dhp.uz/fhir/integrations/CodeSystem/screening-ultrasound-parameter-cs",
            "code" : "scrn-0052-00035"
          }]
        }
        344. Observation.component:internalStructureMacrocalcifications.value[x]
        Контроль1..?
        Типboolean
        [x] ЗаметкаСмотретьВыбор типов данныхдля дополнительной информации о том, как использовать [x]
        Примитивное значениеЭтот примитивный элемент может присутствовать или отсутствовать, или быть замененным расширением

        Рекомендации по толкованию содержимого этой таблицы можно найтиздесь-- no content: do not translate #97 --

        0. Observation
        Определение

        Measurements and simple assertions made about a patient, device or other subject.

        КороткийMeasurements and simple assertions
        Комментарии

        Used for simple observations such as device measurements, laboratory atomic results, vital signs, height, weight, smoking status, comments, etc. Other resources are used to provide context for observations such as laboratory reports, etc.

        Контроль0..*
        Модификаторfalse
        Требуется поддержкаfalse
        Summaryfalse
        Альтернативные именаVital Signs, Measurement, Results, Tests
        Инвариантыdom-2: If the resource is contained in another resource, it SHALL NOT contain nested Resources (contained.contained.empty())
        dom-3: If the resource is contained in another resource, it SHALL be referred to from elsewhere in the resource or SHALL refer to the containing resource (contained.where((('#'+id in (%resource.descendants().reference | %resource.descendants().ofType(canonical) | %resource.descendants().ofType(uri) | %resource.descendants().ofType(url))) or descendants().where(reference = '#').exists() or descendants().where(ofType(canonical) = '#').exists() or descendants().where(ofType(canonical) = '#').exists()).not()).trace('unmatched', id).empty())
        dom-4: If a resource is contained in another resource, it SHALL NOT have a meta.versionId or a meta.lastUpdated (contained.meta.versionId.empty() and contained.meta.lastUpdated.empty())
        dom-5: If a resource is contained in another resource, it SHALL NOT have a security label (contained.meta.security.empty())
        dom-6: A resource should have narrative for robust management (text.`div`.exists())
        obs-6: dataAbsentReason SHALL only be present if Observation.value[x] is not present (dataAbsentReason.empty() or value.empty())
        obs-7: If Observation.component.code is the same as Observation.code, then Observation.value SHALL NOT be present (the Observation.component.value[x] holds the value). (value.empty() or component.code.where(coding.intersect(%resource.code.coding).exists()).empty())
        obs-8: bodyStructure SHALL only be present if Observation.bodySite is not present (bodySite.exists() implies bodyStructure.empty())
        smeta-1: meta.source identifies the DMED or HPV screening system (meta.source.replaceMatches('#.*$', '') in ('https://dhp.uz/fhir/source/screening' | 'https://dhp.uz/fhir/source/dmed'))
        2. Observation.id
        Определение

        The logical id of the resource, as used in the URL for the resource. Once assigned, this value never changes.

        КороткийLogical id of this artifact
        Комментарии

        Within the context of the FHIR RESTful interactions, the resource has an id except for cases like the create and conditional update. Otherwise, the use of the resouce id depends on the given use case.

        Контроль0..1
        Типid
        Модификаторfalse
        Требуется поддержкаfalse
        Summarytrue
        4. Observation.meta
        Определение

        The metadata about the resource. This is content that is maintained by the infrastructure. Changes to the content might not always be associated with version changes to the resource.

        КороткийMetadata about the resource
        Контроль1..1
        ТипMeta
        Модификаторfalse
        Требуется поддержкаtrue
        Summarytrue
        Инвариантыele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
        6. Observation.meta.id
        Определение

        Unique id for the element within a resource (for internal references). This may be any string value that does not contain spaces.

        КороткийUnique id for inter-element referencing
        Контроль0..1
        На этот элемент влияют следующие инварианты: ele-1
        Типid
        Модификаторfalse
        Формат XMLВ формате XML это свойство представлено в качестве атрибута.
        Summaryfalse
        8. Observation.meta.extension
        Определение

        May be used to represent additional information that is not part of the basic definition of the element. To make the use of extensions safe and managable, there is a strict set of governance applied to the definition and use of extensions. Though any implementer can define an extension, there is a set of requirements that SHALL be met as part of the definition of the extension.

        КороткийAdditional content defined by implementations
        Комментарии

        There can be no stigma associated with the use of extensions by any application, project, or standard - regardless of the institution or jurisdiction that uses or defines the extensions. The use of extensions is what allows the FHIR specification to retain a core level of simplicity for everyone.

        Контроль0..*
        ТипExtension
        Модификаторfalse
        Summaryfalse
        Альтернативные именаextensions, user content
        Инвариантыele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
        ext-1: Must have either extensions or value[x], not both (extension.exists() != value.exists())
        SlicingЭтот элемент представляет набор разрезов на Observation.meta.extension. Разрезы бываютНе упорядочено и Open, и могут быть дифференцированы с помощью следующих дискриминаторов:
        • value @ url
        • 10. Observation.meta.versionId
          Определение

          The version specific identifier, as it appears in the version portion of the URL. This value changes when the resource is created, updated, or deleted.

          КороткийVersion specific identifier
          Комментарии

          The server assigns this value, and ignores what the client specifies, except in the case that the server is imposing version integrity on updates/deletes.

          Контроль0..1
          Типid
          Модификаторfalse
          Примитивное значениеЭтот примитивный элемент может присутствовать или отсутствовать, или быть замененным расширением
          Summarytrue
          Инвариантыele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
          12. Observation.meta.lastUpdated
          Определение

          When the resource last changed - e.g. when the version changed.

          КороткийWhen the resource version last changed
          Комментарии

          This element is generally omitted in instances submitted in a PUT or POST. Instead, it is populated in the response instance and when retrieving information using a GET. The server / resource manager sets this value; what a client provides is irrelevant. This is equivalent to the HTTP Last-Modified and SHOULD have the same value on a read interaction.

          Контроль0..1
          Типinstant
          Модификаторfalse
          Примитивное значениеЭтот примитивный элемент может присутствовать или отсутствовать, или быть замененным расширением
          Summarytrue
          Инвариантыele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
          14. Observation.meta.source
          Определение

          A uri that identifies the source system of the resource. This provides a minimal amount of Provenance information that can be used to track or differentiate the source of information in the resource. The source may identify another FHIR server, document, message, database, etc.

          Короткийhttps://dhp.uz/fhir/source/screening | https://dhp.uz/fhir/source/dmed
          Комментарии

          Identifies which system created this resource: the HPV (ВПЧ) screening system or DMED. Do not infer source system from the presence of an identifier from screening-identifier-system -- that system's usage does not indicate which system produced a resource; DMED currently not writing to it is an implementation detail, not a guarantee.

          Контроль1..1
          Типuri
          Модификаторfalse
          Примитивное значениеЭтот примитивный элемент может присутствовать или отсутствовать, или быть замененным расширением
          Требуется поддержкаtrue
          Summarytrue
          Инвариантыele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
          16. Observation.meta.profile
          Определение

          A list of profiles (references to StructureDefinition resources) that this resource claims to conform to. The URL is a reference to StructureDefinition.url.

          КороткийProfiles this resource claims to conform to
          Комментарии

          It is up to the server and/or other infrastructure of policy to determine whether/how these claims are verified and/or updated over time. The list of profile URLs is a set.

          Контроль0..*
          Типcanonical(StructureDefinition)
          Модификаторfalse
          Примитивное значениеЭтот примитивный элемент может присутствовать или отсутствовать, или быть замененным расширением
          Summarytrue
          Инвариантыele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
          18. Observation.meta.security
          Определение

          Security labels applied to this resource. These tags connect specific resources to the overall security policy and infrastructure.

          КороткийSecurity Labels applied to this resource
          Комментарии

          The security labels can be updated without changing the stated version of the resource. The list of security labels is a set. Uniqueness is based the system/code, and version and display are ignored.

          Контроль0..*
          ПривязкаЕсли они не подходят, эти коды ДОЛЖНЫ быть взяты из AllSecurityLabels
          (extensible to http://hl7.org/fhir/ValueSet/security-labels|5.0.0)

          Security Labels from the Healthcare Privacy and Security Classification System.

          ТипCoding
          Модификаторfalse
          Summarytrue
          Инвариантыele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
          20. Observation.meta.tag
          Определение

          Tags applied to this resource. Tags are intended to be used to identify and relate resources to process and workflow, and applications are not required to consider the tags when interpreting the meaning of a resource.

          КороткийTags applied to this resource
          Комментарии

          The tags can be updated without changing the stated version of the resource. The list of tags is a set. Uniqueness is based the system/code, and version and display are ignored.

          Контроль0..*
          ПривязкаНапример, коды см. CommonTags
          (example to http://hl7.org/fhir/ValueSet/common-tags|5.0.0)

          Codes that represent various types of tags, commonly workflow-related; e.g. "Needs review by Dr. Jones".

          ТипCoding
          Модификаторfalse
          Summarytrue
          Инвариантыele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
          22. Observation.implicitRules
          Определение

          A reference to a set of rules that were followed when the resource was constructed, and which must be understood when processing the content. Often, this is a reference to an implementation guide that defines the special rules along with other profiles etc.

          КороткийA set of rules under which this content was created
          Комментарии

          Asserting this rule set restricts the content to be only understood by a limited set of trading partners. This inherently limits the usefulness of the data in the long term. However, the existing health eco-system is highly fractured, and not yet ready to define, collect, and exchange data in a generally computable sense. Wherever possible, implementers and/or specification writers should avoid using this element. Often, when used, the URL is a reference to an implementation guide that defines these special rules as part of its narrative along with other profiles, value sets, etc.

          Контроль0..1
          Типuri
          Модификаторtrue потому что This element is labeled as a modifier because the implicit rules may provide additional knowledge about the resource that modifies its meaning or interpretation
          Примитивное значениеЭтот примитивный элемент может присутствовать или отсутствовать, или быть замененным расширением
          Требуется поддержкаfalse
          Summarytrue
          Инвариантыele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
          24. Observation.language
          Определение

          The base language in which the resource is written.

          КороткийLanguage of the resource content
          Комментарии

          Language is provided to support indexing and accessibility (typically, services such as text to speech use the language tag). The html language tag in the narrative applies to the narrative. The language tag on the resource may be used to specify the language of other presentations generated from the data in the resource. Not all the content has to be in the base language. The Resource.language should not be assumed to apply to the narrative automatically. If a language is specified, it should it also be specified on the div element in the html (see rules in HTML5 for information about the relationship between xml:lang and the html lang attribute).

          Контроль0..1
          ПривязкаКоды ДОЛЖНЫ быть взяты из AllLanguages
          (required to http://hl7.org/fhir/ValueSet/all-languages|5.0.0)

          IETF language tag for a human language

          Типcode
          Модификаторfalse
          Примитивное значениеЭтот примитивный элемент может присутствовать или отсутствовать, или быть замененным расширением
          Требуется поддержкаfalse
          Summaryfalse
          Инвариантыele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
          26. Observation.text
          Определение

          A human-readable narrative that contains a summary of the resource and can be used to represent the content of the resource to a human. The narrative need not encode all the structured data, but is required to contain sufficient detail to make it "clinically safe" for a human to just read the narrative. Resource definitions may define what content should be represented in the narrative to ensure clinical safety.

          КороткийText summary of the resource, for human interpretation
          Комментарии

          Contained resources do not have a narrative. Resources that are not contained SHOULD have a narrative. In some cases, a resource may only have text with little or no additional discrete data (as long as all minOccurs=1 elements are satisfied). This may be necessary for data from legacy systems where information is captured as a "text blob" or where text is additionally entered raw or narrated and encoded information is added later.

          Контроль0..1
          На этот элемент влияют следующие инварианты: dom-6
          ТипNarrative
          Модификаторfalse
          Требуется поддержкаfalse
          Summaryfalse
          Альтернативные именаnarrative, html, xhtml, display
          Инвариантыele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
          28. Observation.contained
          Определение

          These resources do not have an independent existence apart from the resource that contains them - they cannot be identified independently, nor can they have their own independent transaction scope. This is allowed to be a Parameters resource if and only if it is referenced by a resource that provides context/meaning.

          КороткийContained, inline Resources
          Комментарии

          This should never be done when the content can be identified properly, as once identification is lost, it is extremely difficult (and context dependent) to restore it again. Contained resources may have profiles and tags in their meta elements, but SHALL NOT have security labels.

          Контроль0..*
          На этот элемент влияют следующие инварианты: dom-2, dom-4, dom-3, dom-5
          ТипResource
          Модификаторfalse
          Требуется поддержкаfalse
          Summaryfalse
          Альтернативные именаinline resources, anonymous resources, contained resources
          30. Observation.extension
          Определение

          May be used to represent additional information that is not part of the basic definition of the resource. To make the use of extensions safe and managable, there is a strict set of governance applied to the definition and use of extensions. Though any implementer can define an extension, there is a set of requirements that SHALL be met as part of the definition of the extension.

          КороткийAdditional content defined by implementations
          Комментарии

          There can be no stigma associated with the use of extensions by any application, project, or standard - regardless of the institution or jurisdiction that uses or defines the extensions. The use of extensions is what allows the FHIR specification to retain a core level of simplicity for everyone.

          Контроль0..*
          ТипExtension
          Модификаторfalse
          Требуется поддержкаfalse
          Summaryfalse
          Альтернативные именаextensions, user content
          Инвариантыele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
          ext-1: Must have either extensions or value[x], not both (extension.exists() != value.exists())
          32. Observation.modifierExtension
          Определение

          May be used to represent additional information that is not part of the basic definition of the resource and that modifies the understanding of the element that contains it and/or the understanding of the containing element's descendants. Usually modifier elements provide negation or qualification. To make the use of extensions safe and managable, there is a strict set of governance applied to the definition and use of extensions. Though any implementer is allowed to define an extension, there is a set of requirements that SHALL be met as part of the definition of the extension. Applications processing a resource are required to check for modifier extensions.

          Modifier extensions SHALL NOT change the meaning of any elements on Resource or DomainResource (including cannot change the meaning of modifierExtension itself).

          КороткийExtensions that cannot be ignored
          Комментарии

          There can be no stigma associated with the use of extensions by any application, project, or standard - regardless of the institution or jurisdiction that uses or defines the extensions. The use of extensions is what allows the FHIR specification to retain a core level of simplicity for everyone.

          Контроль0..*
          ТипExtension
          Модификаторtrue потому что Modifier extensions are expected to modify the meaning or interpretation of the resource that contains them
          Требуется поддержкаfalse
          Summarytrue
          Требования

          Modifier extensions allow for extensions that cannot be safely ignored to be clearly distinguished from the vast majority of extensions which can be safely ignored. This promotes interoperability by eliminating the need for implementers to prohibit the presence of extensions. For further information, see the definition of modifier extensions.

          Альтернативные именаextensions, user content
          Инвариантыele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
          ext-1: Must have either extensions or value[x], not both (extension.exists() != value.exists())
          34. Observation.identifier
          Определение

          A unique identifier assigned to this observation.

          КороткийBusiness Identifier for observation
          ПримечаниеЭто бизнес-идентификатор, а не идентификатор ресурса (см. обсуждение)
          Контроль0..*
          ТипIdentifier
          Модификаторfalse
          Требуется поддержкаtrue
          Summarytrue
          Требования

          Allows observations to be distinguished and referenced.

          Инвариантыele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
          36. Observation.instantiates[x]
          Определение

          The reference to a FHIR ObservationDefinition resource that provides the definition that is adhered to in whole or in part by this Observation instance.

          КороткийInstantiates FHIR ObservationDefinition
          Комментарии

          ObservationDefinition can be referenced by its canonical url using instantiatesCanonical, or by a name or an identifier using the appropriate sub-elements of instantiatesReference.

          Контроль0..1
          ТипВыбор: canonical(ObservationDefinition), Reference(ObservationDefinition)
          [x] ЗаметкаСмотретьВыбор типов данныхдля дополнительной информации о том, как использовать [x]
          Модификаторfalse
          Примитивное значениеЭтот примитивный элемент может присутствовать или отсутствовать, или быть замененным расширением
          Требуется поддержкаtrue
          Необходимо поддерживать типыНет обязательных правил поддержки выбора типов/профилей
          Summarytrue
          Инвариантыele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
          38. Observation.basedOn
          Определение

          A plan, proposal or order that is fulfilled in whole or in part by this event. For example, a MedicationRequest may require a patient to have laboratory test performed before it is dispensed.

          КороткийFulfills plan, proposal or order
          Контроль0..*
          ТипReference(CarePlan, MedicationRequest, ServiceRequest, UZ Core ImmunizationRecommendation)
          Модификаторfalse
          Требуется поддержкаtrue
          Необходимо поддерживать типыНет обязательных правил поддержки выбора типов/профилей
          Summarytrue
          Требования

          Allows tracing of authorization for the event and tracking whether proposals/recommendations were acted upon.

          Альтернативные именаFulfills
          Инвариантыele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
          40. Observation.triggeredBy
          Определение

          Identifies the observation(s) that triggered the performance of this observation.

          КороткийTriggering observation(s)
          Контроль0..*
          ТипBackboneElement
          Модификаторfalse
          Требуется поддержкаtrue
          Summaryfalse
          Инвариантыele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
          42. Observation.triggeredBy.id
          Определение

          Unique id for the element within a resource (for internal references). This may be any string value that does not contain spaces.

          КороткийUnique id for inter-element referencing
          Контроль0..1
          На этот элемент влияют следующие инварианты: ele-1
          Типstring
          Модификаторfalse
          Формат XMLВ формате XML это свойство представлено в качестве атрибута.
          Summaryfalse
          44. Observation.triggeredBy.extension
          Определение

          May be used to represent additional information that is not part of the basic definition of the element. To make the use of extensions safe and managable, there is a strict set of governance applied to the definition and use of extensions. Though any implementer can define an extension, there is a set of requirements that SHALL be met as part of the definition of the extension.

          КороткийAdditional content defined by implementations
          Комментарии

          There can be no stigma associated with the use of extensions by any application, project, or standard - regardless of the institution or jurisdiction that uses or defines the extensions. The use of extensions is what allows the FHIR specification to retain a core level of simplicity for everyone.

          Контроль0..*
          ТипExtension
          Модификаторfalse
          Summaryfalse
          Альтернативные именаextensions, user content
          Инвариантыele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
          ext-1: Must have either extensions or value[x], not both (extension.exists() != value.exists())
          46. Observation.triggeredBy.modifierExtension
          Определение

          May be used to represent additional information that is not part of the basic definition of the element and that modifies the understanding of the element in which it is contained and/or the understanding of the containing element's descendants. Usually modifier elements provide negation or qualification. To make the use of extensions safe and managable, there is a strict set of governance applied to the definition and use of extensions. Though any implementer can define an extension, there is a set of requirements that SHALL be met as part of the definition of the extension. Applications processing a resource are required to check for modifier extensions.

          Modifier extensions SHALL NOT change the meaning of any elements on Resource or DomainResource (including cannot change the meaning of modifierExtension itself).

          КороткийExtensions that cannot be ignored even if unrecognized
          Комментарии

          There can be no stigma associated with the use of extensions by any application, project, or standard - regardless of the institution or jurisdiction that uses or defines the extensions. The use of extensions is what allows the FHIR specification to retain a core level of simplicity for everyone.

          Контроль0..*
          ТипExtension
          Модификаторtrue потому что Modifier extensions are expected to modify the meaning or interpretation of the element that contains them
          Summarytrue
          Требования

          Modifier extensions allow for extensions that cannot be safely ignored to be clearly distinguished from the vast majority of extensions which can be safely ignored. This promotes interoperability by eliminating the need for implementers to prohibit the presence of extensions. For further information, see the definition of modifier extensions.

          Альтернативные именаextensions, user content, modifiers
          Инвариантыele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
          ext-1: Must have either extensions or value[x], not both (extension.exists() != value.exists())
          48. Observation.triggeredBy.observation
          Определение

          Reference to the triggering observation.

          КороткийTriggering observation
          Контроль1..1
          ТипReference(UZ Core Observation)
          Модификаторfalse
          Требуется поддержкаfalse
          Summarytrue
          Инвариантыele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
          50. Observation.triggeredBy.type
          Определение

          The type of trigger. Reflex | Repeat | Re-run.

          Короткийreflex | repeat | re-run
          Контроль1..1
          ПривязкаКоды ДОЛЖНЫ быть взяты из TriggeredByTypeVS (0.12.0)
          (required to https://terminology.dhp.uz/fhir/core/ValueSet/triggered-bytype-vs|0.12.0)
          Типcode
          Модификаторfalse
          Примитивное значениеЭтот примитивный элемент может присутствовать или отсутствовать, или быть замененным расширением
          Требуется поддержкаfalse
          Summarytrue
          Инвариантыele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
          52. Observation.triggeredBy.reason
          Определение

          Provides the reason why this observation was performed as a result of the observation(s) referenced.

          КороткийReason that the observation was triggered
          Контроль0..1
          Типstring
          Модификаторfalse
          Примитивное значениеЭтот примитивный элемент может присутствовать или отсутствовать, или быть замененным расширением
          Требуется поддержкаtrue
          Summaryfalse
          Инвариантыele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
          54. Observation.partOf
          Определение

          A larger event of which this particular Observation is a component or step. For example, an observation as part of a procedure.

          КороткийPart of referenced event
          Комментарии

          To link an Observation to an Encounter use encounter. See the Notes below for guidance on referencing another Observation.

          Контроль0..*
          ТипReference(MedicationAdministration, MedicationDispense, UZ Core Procedure, UZ Core Immunization, ImagingStudy)
          Модификаторfalse
          Требуется поддержкаtrue
          Необходимо поддерживать типыНет обязательных правил поддержки выбора типов/профилей
          Summarytrue
          Альтернативные именаContainer
          Инвариантыele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
          56. Observation.status
          Определение

          The status of the result value.

          Короткийregistered | preliminary | final | amended +
          Комментарии

          This element is labeled as a modifier because the status contains codes that mark the resource as not currently valid.

          Контроль1..1
          ПривязкаКоды ДОЛЖНЫ быть взяты из ObservationStatusVS (0.12.0)
          (required to https://terminology.dhp.uz/fhir/core/ValueSet/observation-status-vs|0.12.0)
          Типcode
          Модификаторtrue потому что This element is labeled as a modifier because it is a status element that contains status entered-in-error which means that the resource should not be treated as valid
          Примитивное значениеЭтот примитивный элемент может присутствовать или отсутствовать, или быть замененным расширением
          Требуется поддержкаtrue
          Summarytrue
          Требования

          Need to track the status of individual results. Some results are finalized before the whole report is finalized.

          Инвариантыele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
          58. Observation.category
          Определение

          A code that classifies the general type of observation being made.

          КороткийClassification of type of observation
          Комментарии

          In addition to the required category valueset, this element allows various categorization schemes based on the owner’s definition of the category and effectively multiple categories can be used at once. The level of granularity is defined by the category concepts in the value set.

          Контроль0..*
          ПривязкаКоды СЛЕДУЕТ взять из ObservationCategoryVS (0.12.0)
          (preferred to https://terminology.dhp.uz/fhir/core/ValueSet/observation-category-vs|0.12.0)
          ТипCodeableConcept
          Модификаторfalse
          Требуется поддержкаtrue
          Summaryfalse
          Требования

          Used for filtering what observations are retrieved and displayed.

          Инвариантыele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
          SlicingЭтот элемент представляет набор разрезов на Observation.category. Разрезы бываютНе упорядочено и Open, и могут быть дифференцированы с помощью следующих дискриминаторов:
          • value @ $this
          • 60. Observation.category:dhpCategory
            Название разрезаdhpCategory
            Определение

            A code that classifies the general type of observation being made.

            КороткийCategory from the national value set
            Комментарии

            In addition to the required category valueset, this element allows various categorization schemes based on the owner’s definition of the category and effectively multiple categories can be used at once. The level of granularity is defined by the category concepts in the value set.

            Контроль0..*
            ПривязкаКоды ДОЛЖНЫ быть взяты из ObservationCategoryVS (0.12.0)
            (required to https://terminology.dhp.uz/fhir/core/ValueSet/observation-category-vs|0.12.0)
            ТипCodeableConcept
            Модификаторfalse
            Требуется поддержкаtrue
            Summaryfalse
            Требования

            Used for filtering what observations are retrieved and displayed.

            Инвариантыele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
            62. Observation.code
            Определение

            Describes what was observed. Sometimes this is called the observation "name".

            КороткийType of observation (code / type)
            Комментарии

            All code-value and, if present, component.code-component.value pairs need to be taken into account to correctly understand the meaning of the observation.

            Контроль1..1
            На этот элемент влияют следующие инварианты: obs-7
            ПривязкаКоды СЛЕДУЕТ взять из ScreeningObservationCodesVS (0.12.1)
            (preferred to https://terminology.dhp.uz/fhir/integrations/ValueSet/screening-observation-codes-vs|0.12.1)
            ТипCodeableConcept
            Модификаторfalse
            Требуется поддержкаtrue
            Summarytrue
            Требования

            Knowing what kind of observation is being made is essential to understanding the observation.

            Альтернативные именаName
            Значение шаблона{
              "coding" : [{
                "system" : "http://snomed.info/sct",
                "code" : "47079000",
                "display" : "Ultrasonography of breast"
              }]
            }
            Инвариантыele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
            64. Observation.subject
            Определение

            The patient, or group of patients, location, device, organization, procedure or practitioner this observation is about and into whose or what record the observation is placed. If the actual focus of the observation is different from the subject (or a sample of, part, or region of the subject), the focus element or the code itself specifies the actual focus of the observation.

            КороткийWho and/or what the observation is about
            Комментарии

            One would expect this element to be a cardinality of 1..1. The only circumstance in which the subject can be missing is when the observation is made by a device that does not know the patient. In this case, the observation SHALL be matched to a patient through some context/channel matching technique, and at this point, the observation should be updated. The subject of an Observation may in some cases be a procedure. This supports the regulatory inspection use case where observations are captured during inspections of a procedure that is being performed (independent of any particular patient or whether patient related at all).

            Контроль0..1
            ТипReference(UZ Core Patient, UZ Core Location, UZ Core Organization, UZ Core Procedure, UZ Core Practitioner, UZ Core Medication)
            Модификаторfalse
            Требуется поддержкаtrue
            Необходимо поддерживать типыНет обязательных правил поддержки выбора типов/профилей
            Summarytrue
            Требования

            Observations have no value if you don't know who or what they're about.

            Инвариантыele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
            66. Observation.focus
            Определение

            The actual focus of an observation when it is not the patient of record representing something or someone associated with the patient such as a spouse, parent, fetus, or donor. For example, fetus observations in a mother's record. The focus of an observation could also be an existing condition, an intervention, the subject's diet, another observation of the subject, or a body structure such as tumor or implanted device. An example use case would be using the Observation resource to capture whether the mother is trained to change her child's tracheostomy tube. In this example, the child is the patient of record and the mother is the focus.

            КороткийWhat the observation is about, when it is not about the subject of record
            Комментарии

            Typically, an observation is made about the subject - a patient, or group of patients, location, or device - and the distinction between the subject and what is directly measured for an observation is specified in the observation code itself ( e.g., "Blood Glucose") and does not need to be represented separately using this element. Use specimen if a reference to a specimen is required. If a code is required instead of a resource use either bodysite for bodysites or the standard extension http://hl7.org/fhir/StructureDefinition/observation-focusCode.

            Контроль0..*
            ТипReference(Resource)
            Модификаторfalse
            Требуется поддержкаtrue
            Summarytrue
            Инвариантыele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
            68. Observation.encounter
            Определение

            The healthcare event (e.g. a patient and healthcare provider interaction) during which this observation is made.

            КороткийHealthcare event during which this observation is made
            Комментарии

            This will typically be the encounter the event occurred within, but some events may be initiated prior to or after the official completion of an encounter but still be tied to the context of the encounter (e.g. pre-admission laboratory tests).

            Контроль0..1
            ТипReference(UZ Core Encounter)
            Модификаторfalse
            Требуется поддержкаtrue
            Summarytrue
            Требования

            For some observations it may be important to know the link between an observation and a particular encounter.

            Альтернативные именаContext
            Инвариантыele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
            70. Observation.effective[x]
            Определение

            The time or time-period the observed value is asserted as being true. For biological subjects - e.g. human patients - this is usually called the "physiologically relevant time". This is usually either the time of the procedure or of specimen collection, but very often the source of the date/time is not known, only the date/time itself.

            КороткийClinically relevant time/time-period for observation
            Комментарии

            At least a date should be present unless this observation is a historical report. For recording imprecise or "fuzzy" times (For example, a blood glucose measurement taken "after breakfast") use the Timing datatype which allow the measurement to be tied to regular life events.

            Контроль0..1
            ТипВыбор: dateTime, Period, Timing, instant
            [x] ЗаметкаСмотретьВыбор типов данныхдля дополнительной информации о том, как использовать [x]
            Модификаторfalse
            Примитивное значениеЭтот примитивный элемент может присутствовать или отсутствовать, или быть замененным расширением
            Требуется поддержкаtrue
            Необходимо поддерживать типыНет обязательных правил поддержки выбора типов/профилей
            Summarytrue
            Требования

            Knowing when an observation was deemed true is important to its relevance as well as determining trends.

            Альтернативные именаOccurrence
            Инвариантыele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
            72. Observation.issued
            Определение

            The date and time this version of the observation was made available to providers, typically after the results have been reviewed and verified.

            КороткийDate/Time this version was made available
            Комментарии

            For Observations that don't require review and verification, it may be the same as the lastUpdated time of the resource itself. For Observations that do require review and verification for certain updates, it might not be the same as the lastUpdated time of the resource itself due to a non-clinically significant update that doesn't require the new version to be reviewed and verified again.

            Контроль0..1
            Типinstant
            Модификаторfalse
            Примитивное значениеЭтот примитивный элемент может присутствовать или отсутствовать, или быть замененным расширением
            Требуется поддержкаtrue
            Summarytrue
            Инвариантыele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
            74. Observation.performer
            Определение

            Who was responsible for asserting the observed value as "true".

            КороткийWho is responsible for the observation
            Контроль0..*
            ТипReference(UZ Core Practitioner, UZ Core PractitionerRole, UZ Core Organization)
            Модификаторfalse
            Требуется поддержкаtrue
            Необходимо поддерживать типыНет обязательных правил поддержки выбора типов/профилей
            Summarytrue
            Требования

            May give a degree of confidence in the observation and also indicates where follow-up questions should be directed.

            Инвариантыele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
            76. Observation.value[x]
            Определение

            The information determined as a result of making the observation, if the information has a simple value.

            КороткийActual result
            Комментарии
            • An observation may have:
              1. a single value here
              2. both a value and a set of related or component values
              3. only a set of related or component values.
            • If a value is present, the datatype for this element should be determined by the code.
            • CodeableConcept with just a text would be used instead of a string if the field was usually coded, or if the type associated with the code defines a coded value.
            • Attachment is used if the observation result value is a binary file such as an image. If the observation result value is derived from the binary file (for example 'X' detected and here is the the proof in this image), the binary file may be directly represented using DocumentReference and referenced by derivedFrom.
            • The usage of valueReference is restricted to the MolecularSequence resource when used as a definitional resource, not as a patient-specific finding. .
            • For additional guidance, see the Notes section below.
            Контроль0..1
            На этот элемент влияют следующие инварианты: obs-7, obs-6
            ТипCodeableConcept
            [x] ЗаметкаСмотретьВыбор типов данныхдля дополнительной информации о том, как использовать [x]
            Модификаторfalse
            Требуется поддержкаtrue
            Summarytrue
            Требования

            An observation exists to have a value, though it might not if it is in error, or if it represents a group of observations.

            Инвариантыele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
            SlicingЭтот элемент представляет набор разрезов на Observation.value[x]. Разрезы бываютНе упорядочено и Closed, и могут быть дифференцированы с помощью следующих дискриминаторов:
            • type @ $this
            • 78. Observation.value[x]:valueCodeableConcept
              Название разрезаvalueCodeableConcept
              Определение

              The information determined as a result of making the observation, if the information has a simple value.

              КороткийActual result
              Комментарии
              • An observation may have:
                1. a single value here
                2. both a value and a set of related or component values
                3. only a set of related or component values.
              • If a value is present, the datatype for this element should be determined by the code.
              • CodeableConcept with just a text would be used instead of a string if the field was usually coded, or if the type associated with the code defines a coded value.
              • Attachment is used if the observation result value is a binary file such as an image. If the observation result value is derived from the binary file (for example 'X' detected and here is the the proof in this image), the binary file may be directly represented using DocumentReference and referenced by derivedFrom.
              • The usage of valueReference is restricted to the MolecularSequence resource when used as a definitional resource, not as a patient-specific finding. .
              • For additional guidance, see the Notes section below.
              Контроль0..1
              На этот элемент влияют следующие инварианты: obs-7, obs-6
              ПривязкаКоды СЛЕДУЕТ взять из ScreeningObservationValuesVS (0.12.1)
              (preferred to https://terminology.dhp.uz/fhir/integrations/ValueSet/screening-observation-values-vs|0.12.1)
              ТипCodeableConcept
              [x] ЗаметкаСмотретьВыбор типов данныхдля дополнительной информации о том, как использовать [x]
              Модификаторfalse
              Требуется поддержкаtrue
              Summarytrue
              Требования

              An observation exists to have a value, though it might not if it is in error, or if it represents a group of observations.

              Инвариантыele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
              80. Observation.dataAbsentReason
              Определение

              Provides a reason why the expected value in the element Observation.value[x] is missing.

              КороткийWhy the result is missing
              Комментарии

              Null or exceptional values can be represented two ways in FHIR Observations. One way is to simply include them in the value set and represent the exceptions in the value. For example, measurement values for a serology test could be "detected", "not detected", "inconclusive", or "specimen unsatisfactory".

              The alternate way is to use the value element for actual observations and use the explicit dataAbsentReason element to record exceptional values. For example, the dataAbsentReason code "error" could be used when the measurement was not completed. Note that an observation may only be reported if there are values to report. For example differential cell counts values may be reported only when > 0. Because of these options, use-case agreements are required to interpret general observations for null or exceptional values.

              Контроль0..1
              На этот элемент влияют следующие инварианты: obs-6
              ПривязкаЕсли они не подходят, эти коды ДОЛЖНЫ быть взяты из DataAbsentReasonVS (0.12.0)
              (extensible to https://terminology.dhp.uz/fhir/core/ValueSet/data-absent-reason-vs|0.12.0)
              ТипCodeableConcept
              Модификаторfalse
              Требуется поддержкаtrue
              Summaryfalse
              Требования

              For many results it is necessary to handle exceptional values in measurements.

              Инвариантыele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
              82. Observation.interpretation
              Определение

              A categorical assessment of an observation value. For example, high, low, normal.

              КороткийHigh, low, normal, etc
              Комментарии

              Historically used for laboratory results (known as 'abnormal flag' ), its use extends to other use cases where coded interpretations are relevant. Often reported as one or more simple compact codes this element is often placed adjacent to the result value in reports and flow sheets to signal the meaning/normalcy status of the result.

              Контроль0..*
              ПривязкаЕсли они не подходят, эти коды ДОЛЖНЫ быть взяты из ObservationInterpretationVS (0.12.0)
              (extensible to https://terminology.dhp.uz/fhir/core/ValueSet/observation-interpretation-vs|0.12.0)
              ТипCodeableConcept
              Модификаторfalse
              Требуется поддержкаfalse
              Summaryfalse
              Требования

              For some results, particularly numeric results, an interpretation is necessary to fully understand the significance of a result.

              Альтернативные именаAbnormal Flag
              Инвариантыele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
              84. Observation.note
              Определение

              Comments about the observation or the results.

              КороткийComments about the observation
              Комментарии

              May include general statements about the observation, or statements about significant, unexpected or unreliable results values, or information about its source when relevant to its interpretation.

              Контроль0..*
              ТипAnnotation
              Модификаторfalse
              Требуется поддержкаtrue
              Summaryfalse
              Требования

              Need to be able to provide free text additional information.

              Инвариантыele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
              86. Observation.bodySite
              Определение

              Indicates the site on the subject's body where the observation was made (i.e. the target site).

              КороткийExamined breast side
              Комментарии

              Only used if not implicit in code found in Observation.code. In many systems, this may be represented as a related observation instead of an inline component.

              Контроль1..1
              На этот элемент влияют следующие инварианты: obs-8
              ПривязкаКоды ДОЛЖНЫ быть взяты из ScreeningUltrasoundBreastSideVS (0.12.1)
              (required to https://terminology.dhp.uz/fhir/integrations/ValueSet/screening-ultrasound-breast-side-vs|0.12.1)
              ТипCodeableConcept
              Модификаторfalse
              Требуется поддержкаtrue
              Summaryfalse
              Инвариантыele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
              88. Observation.bodySite.id
              Определение

              Unique id for the element within a resource (for internal references). This may be any string value that does not contain spaces.

              КороткийUnique id for inter-element referencing
              Контроль0..1
              На этот элемент влияют следующие инварианты: ele-1
              Типid
              Модификаторfalse
              Формат XMLВ формате XML это свойство представлено в качестве атрибута.
              Summaryfalse
              90. Observation.bodySite.extension
              Определение

              May be used to represent additional information that is not part of the basic definition of the element. To make the use of extensions safe and managable, there is a strict set of governance applied to the definition and use of extensions. Though any implementer can define an extension, there is a set of requirements that SHALL be met as part of the definition of the extension.

              КороткийAdditional content defined by implementations
              Комментарии

              There can be no stigma associated with the use of extensions by any application, project, or standard - regardless of the institution or jurisdiction that uses or defines the extensions. The use of extensions is what allows the FHIR specification to retain a core level of simplicity for everyone.

              Контроль0..*
              ТипExtension
              Модификаторfalse
              Summaryfalse
              Альтернативные именаextensions, user content
              Инвариантыele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
              ext-1: Must have either extensions or value[x], not both (extension.exists() != value.exists())
              SlicingЭтот элемент представляет набор разрезов на Observation.bodySite.extension. Разрезы бываютНе упорядочено и Open, и могут быть дифференцированы с помощью следующих дискриминаторов:
              • value @ url
              • 92. Observation.bodySite.extension:quadrant
                Название разрезаquadrant
                Определение

                Breast quadrant used to localize findings.

                КороткийBreast Quadrant Extension
                Контроль0..*
                ТипExtension(Breast Quadrant Extension) (Тип расширения: CodeableConcept)
                Модификаторfalse
                Требуется поддержкаtrue
                Summaryfalse
                Инвариантыele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
                ext-1: Must have either extensions or value[x], not both (extension.exists() != value.exists())
                94. Observation.bodySite.coding
                Определение

                A reference to a code defined by a terminology system.

                КороткийCode defined by a terminology system
                Комментарии

                Codes may be defined very casually in enumerations, or code lists, up to very formal definitions such as SNOMED CT - see the HL7 v3 Core Principles for more information. Ordering of codings is undefined and SHALL NOT be used to infer meaning. Generally, at most only one of the coding values will be labeled as UserSelected = true.

                Контроль0..*
                ТипCoding
                Модификаторfalse
                Summarytrue
                Требования

                Allows for alternative encodings within a code system, and translations to other code systems.

                Инвариантыele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
                96. Observation.bodySite.text
                Определение

                A human language representation of the concept as seen/selected/uttered by the user who entered the data and/or which represents the intended meaning of the user.

                КороткийPlain text representation of the concept
                Комментарии

                Very often the text is the same as a displayName of one of the codings.

                Контроль0..1
                Типstring
                Модификаторfalse
                Примитивное значениеЭтот примитивный элемент может присутствовать или отсутствовать, или быть замененным расширением
                Summarytrue
                Требования

                The codes from the terminologies do not always capture the correct meaning with all the nuances of the human using them, or sometimes there is no appropriate code at all. In these cases, the text is used to capture the full meaning of the source.

                Инвариантыele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
                98. Observation.bodyStructure
                Определение

                Indicates the body structure on the subject's body where the observation was made (i.e. the target site).

                КороткийObserved body structure
                Комментарии

                Only used if not implicit in code found in Observation.code or bodySite is used. In many systems, this may be represented as a related observation instead of an inline component.

                Контроль0..1
                На этот элемент влияют следующие инварианты: obs-8
                ТипReference(BodyStructure)
                Модификаторfalse
                Требуется поддержкаfalse
                Summaryfalse
                Инвариантыele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
                100. Observation.method
                Определение

                Indicates the mechanism used to perform the observation.

                КороткийHow it was done
                Комментарии

                Only used if not implicit in code for Observation.code.

                Контроль0..1
                ПривязкаЕсли они не подходят, эти коды ДОЛЖНЫ быть взяты из LabMethodsVS (0.12.0)
                (extensible to https://terminology.dhp.uz/fhir/core/ValueSet/lab-method-vs|0.12.0)
                ТипCodeableConcept
                Модификаторfalse
                Требуется поддержкаfalse
                Summaryfalse
                Требования

                In some cases, method can impact results and is thus used for determining whether results can be compared or determining significance of results.

                Инвариантыele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
                102. Observation.specimen
                Определение

                The specimen that was used when this observation was made.

                КороткийSpecimen used for this observation
                Комментарии

                Should only be used if not implicit in code found in Observation.code. Observations are not made on specimens themselves; they are made on a subject, but in many cases by the means of a specimen. Note that although specimens are often involved, they are not always tracked and reported explicitly. Also note that observation resources may be used in contexts that track the specimen explicitly (e.g. Diagnostic Report).

                Контроль0..1
                ТипReference(UZ Core Specimen)
                Модификаторfalse
                Требуется поддержкаtrue
                Summaryfalse
                Инвариантыele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
                obs-9: If Observation.specimen is a reference to Group, the group can only have specimens ((reference.resolve().exists() and reference.resolve() is Group) implies reference.resolve().member.entity.resolve().all($this is Specimen))
                104. Observation.device
                Определение

                A reference to the device that generates the measurements or the device settings for the device.

                КороткийA reference to the device that generates the measurements or the device settings for the device
                Комментарии

                Note that this is not meant to represent a device involved in the transmission of the result, e.g., a gateway. Such devices may be documented using the Provenance resource where relevant.

                Контроль0..1
                ТипReference(Device, DeviceMetric)
                Модификаторfalse
                Требуется поддержкаtrue
                Необходимо поддерживать типыНет обязательных правил поддержки выбора типов/профилей
                Summaryfalse
                Инвариантыele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
                106. Observation.referenceRange
                Определение

                Guidance on how to interpret the value by comparison to a normal or recommended range. Multiple reference ranges are interpreted as an "OR". In other words, to represent two distinct target populations, two referenceRange elements would be used.

                КороткийProvides guide for interpretation
                Комментарии

                Most observations only have one generic reference range. Systems MAY choose to restrict to only supplying the relevant reference range based on knowledge about the patient (e.g., specific to the patient's age, gender, weight and other factors), but this might not be possible or appropriate. Whenever more than one reference range is supplied, the differences between them SHOULD be provided in the reference range and/or age properties.

                Контроль0..*
                ТипBackboneElement
                Модификаторfalse
                Требуется поддержкаtrue
                Summaryfalse
                Требования

                Knowing what values are considered "normal" can help evaluate the significance of a particular result. Need to be able to provide multiple reference ranges for different contexts.

                Инвариантыele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
                obs-3: Must have at least a low or a high or text (low.exists() or high.exists() or text.exists())
                108. Observation.referenceRange.id
                Определение

                Unique id for the element within a resource (for internal references). This may be any string value that does not contain spaces.

                КороткийUnique id for inter-element referencing
                Контроль0..1
                На этот элемент влияют следующие инварианты: ele-1
                Типstring
                Модификаторfalse
                Формат XMLВ формате XML это свойство представлено в качестве атрибута.
                Summaryfalse
                110. Observation.referenceRange.extension
                Определение

                May be used to represent additional information that is not part of the basic definition of the element. To make the use of extensions safe and managable, there is a strict set of governance applied to the definition and use of extensions. Though any implementer can define an extension, there is a set of requirements that SHALL be met as part of the definition of the extension.

                КороткийAdditional content defined by implementations
                Комментарии

                There can be no stigma associated with the use of extensions by any application, project, or standard - regardless of the institution or jurisdiction that uses or defines the extensions. The use of extensions is what allows the FHIR specification to retain a core level of simplicity for everyone.

                Контроль0..*
                ТипExtension
                Модификаторfalse
                Summaryfalse
                Альтернативные именаextensions, user content
                Инвариантыele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
                ext-1: Must have either extensions or value[x], not both (extension.exists() != value.exists())
                112. Observation.referenceRange.modifierExtension
                Определение

                May be used to represent additional information that is not part of the basic definition of the element and that modifies the understanding of the element in which it is contained and/or the understanding of the containing element's descendants. Usually modifier elements provide negation or qualification. To make the use of extensions safe and managable, there is a strict set of governance applied to the definition and use of extensions. Though any implementer can define an extension, there is a set of requirements that SHALL be met as part of the definition of the extension. Applications processing a resource are required to check for modifier extensions.

                Modifier extensions SHALL NOT change the meaning of any elements on Resource or DomainResource (including cannot change the meaning of modifierExtension itself).

                КороткийExtensions that cannot be ignored even if unrecognized
                Комментарии

                There can be no stigma associated with the use of extensions by any application, project, or standard - regardless of the institution or jurisdiction that uses or defines the extensions. The use of extensions is what allows the FHIR specification to retain a core level of simplicity for everyone.

                Контроль0..*
                ТипExtension
                Модификаторtrue потому что Modifier extensions are expected to modify the meaning or interpretation of the element that contains them
                Summarytrue
                Требования

                Modifier extensions allow for extensions that cannot be safely ignored to be clearly distinguished from the vast majority of extensions which can be safely ignored. This promotes interoperability by eliminating the need for implementers to prohibit the presence of extensions. For further information, see the definition of modifier extensions.

                Альтернативные именаextensions, user content, modifiers
                Инвариантыele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
                ext-1: Must have either extensions or value[x], not both (extension.exists() != value.exists())
                114. Observation.referenceRange.low
                Определение

                The value of the low bound of the reference range. The low bound of the reference range endpoint is inclusive of the value (e.g. reference range is >=5 - <=9). If the low bound is omitted, it is assumed to be meaningless (e.g. reference range is <=2.3).

                КороткийLow Range, if relevant
                Контроль0..1
                На этот элемент влияют следующие инварианты: obs-3
                ТипQuantity(SimpleQuantity)
                Модификаторfalse
                Требуется поддержкаtrue
                Summaryfalse
                Инвариантыele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
                116. Observation.referenceRange.high
                Определение

                The value of the high bound of the reference range. The high bound of the reference range endpoint is inclusive of the value (e.g. reference range is >=5 - <=9). If the high bound is omitted, it is assumed to be meaningless (e.g. reference range is >= 2.3).

                КороткийHigh Range, if relevant
                Контроль0..1
                На этот элемент влияют следующие инварианты: obs-3
                ТипQuantity(SimpleQuantity)
                Модификаторfalse
                Требуется поддержкаtrue
                Summaryfalse
                Инвариантыele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
                118. Observation.referenceRange.normalValue
                Определение

                The value of the normal value of the reference range.

                КороткийNormal value, if relevant
                Контроль0..1
                ПривязкаЕсли они не подходят, эти коды ДОЛЖНЫ быть взяты из ObservationNormalValueVS (0.12.0)
                (extensible to https://terminology.dhp.uz/fhir/core/ValueSet/observation-normal-value-vs|0.12.0)
                ТипCodeableConcept
                Модификаторfalse
                Требуется поддержкаtrue
                Summaryfalse
                Инвариантыele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
                120. Observation.referenceRange.type
                Определение

                Codes to indicate the what part of the targeted reference population it applies to. For example, the normal or therapeutic range.

                КороткийReference range qualifier
                Комментарии

                This SHOULD be populated if there is more than one range. If this element is not present then the normal range is assumed.

                Контроль0..1
                ПривязкаКоды СЛЕДУЕТ взять из ReferenceRangeMeaningVS (0.12.0)
                (preferred to https://terminology.dhp.uz/fhir/core/ValueSet/reference-range-meaning-vs|0.12.0)
                ТипCodeableConcept
                Модификаторfalse
                Требуется поддержкаfalse
                Summaryfalse
                Требования

                Need to be able to say what kind of reference range this is - normal, recommended, therapeutic, etc., - for proper interpretation.

                Инвариантыele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
                122. Observation.referenceRange.appliesTo
                Определение

                Codes to indicate the target population this reference range applies to. For example, a reference range may be based on the normal population or a particular sex or race. Multiple appliesTo are interpreted as an "AND" of the target populations. For example, to represent a target population of African American females, both a code of female and a code for African American would be used.

                КороткийReference range population
                Комментарии

                This SHOULD be populated if there is more than one range. If this element is not present then the normal population is assumed.

                Контроль0..*
                ПривязкаНапример, коды см. ObservationReferenceRangeAppliesToCodes
                (example to http://hl7.org/fhir/ValueSet/referencerange-appliesto|5.0.0)

                Codes identifying the population the reference range applies to.

                ТипCodeableConcept
                Модификаторfalse
                Требуется поддержкаfalse
                Summaryfalse
                Требования

                Need to be able to identify the target population for proper interpretation.

                Инвариантыele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
                124. Observation.referenceRange.age
                Определение

                The age at which this reference range is applicable. This is a neonatal age (e.g. number of weeks at term) if the meaning says so.

                КороткийApplicable age range, if relevant
                Контроль0..1
                ТипRange
                Модификаторfalse
                Требуется поддержкаtrue
                Summaryfalse
                Требования

                Some analytes vary greatly over age.

                Инвариантыele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
                126. Observation.referenceRange.text
                Определение

                Text based reference range in an observation which may be used when a quantitative range is not appropriate for an observation. An example would be a reference value of "Negative" or a list or table of "normals".

                КороткийText based reference range in an observation
                Контроль0..1
                На этот элемент влияют следующие инварианты: obs-3
                Типmarkdown
                Модификаторfalse
                Примитивное значениеЭтот примитивный элемент может присутствовать или отсутствовать, или быть замененным расширением
                Требуется поддержкаtrue
                Summaryfalse
                Инвариантыele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
                128. Observation.hasMember
                Определение

                This observation is a group observation (e.g. a battery, a panel of tests, a set of vital sign measurements) that includes the target as a member of the group.

                КороткийRelated resource that belongs to the Observation group
                Комментарии

                When using this element, an observation will typically have either a value or a set of related resources, although both may be present in some cases. For a discussion on the ways Observations can assembled in groups together, see Notes below. Note that a system may calculate results from QuestionnaireResponse into a final score and represent the score as an Observation.

                Контроль0..*
                ТипReference(UZ Core Observation, UZ Core QuestionnaireResponse)
                Модификаторfalse
                Требуется поддержкаtrue
                Необходимо поддерживать типыНет обязательных правил поддержки выбора типов/профилей
                Summarytrue
                Инвариантыele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
                130. Observation.derivedFrom
                Определение

                The target resource that represents a measurement from which this observation value is derived. For example, a calculated anion gap or a fetal measurement based on an ultrasound image.

                КороткийRelated resource from which the observation is made
                Комментарии

                All the reference choices that are listed in this element can represent clinical observations and other measurements that may be the source for a derived value. The most common reference will be another Observation. For a discussion on the ways Observations can assembled in groups together, see Notes below.

                Контроль0..*
                ТипReference(DocumentReference, ImagingStudy, UZ Core QuestionnaireResponse, UZ Core Observation)
                Модификаторfalse
                Требуется поддержкаtrue
                Необходимо поддерживать типыНет обязательных правил поддержки выбора типов/профилей
                Summarytrue
                Инвариантыele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
                132. Observation.component
                Определение

                Some observations have multiple component observations. These component observations are expressed as separate code value pairs that share the same attributes. Examples include systolic and diastolic component observations for blood pressure measurement and multiple component observations for genetics observations.

                КороткийComponent results
                Комментарии

                For a discussion on the ways Observations can be assembled in groups together see Notes below.

                Контроль0..*
                На этот элемент влияют следующие инварианты: obs-7
                ТипBackboneElement
                Модификаторfalse
                Требуется поддержкаtrue
                Summarytrue
                Требования

                Component observations share the same attributes in the Observation resource as the primary observation and are always treated a part of a single observation (they are not separable). However, the reference range for the primary observation value is not inherited by the component values and is required when appropriate for each component observation.

                Инвариантыele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
                SlicingЭтот элемент представляет набор разрезов на Observation.component. Разрезы бываютНе упорядочено и Open, и могут быть дифференцированы с помощью следующих дискриминаторов:
                • value @ code
                • 134. Observation.component.id
                  Определение

                  Unique id for the element within a resource (for internal references). This may be any string value that does not contain spaces.

                  КороткийUnique id for inter-element referencing
                  Контроль0..1
                  На этот элемент влияют следующие инварианты: ele-1
                  Типstring
                  Модификаторfalse
                  Формат XMLВ формате XML это свойство представлено в качестве атрибута.
                  Summaryfalse
                  136. Observation.component.extension
                  Определение

                  May be used to represent additional information that is not part of the basic definition of the element. To make the use of extensions safe and managable, there is a strict set of governance applied to the definition and use of extensions. Though any implementer can define an extension, there is a set of requirements that SHALL be met as part of the definition of the extension.

                  КороткийAdditional content defined by implementations
                  Комментарии

                  There can be no stigma associated with the use of extensions by any application, project, or standard - regardless of the institution or jurisdiction that uses or defines the extensions. The use of extensions is what allows the FHIR specification to retain a core level of simplicity for everyone.

                  Контроль0..*
                  ТипExtension
                  Модификаторfalse
                  Summaryfalse
                  Альтернативные именаextensions, user content
                  Инвариантыele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
                  ext-1: Must have either extensions or value[x], not both (extension.exists() != value.exists())
                  138. Observation.component.modifierExtension
                  Определение

                  May be used to represent additional information that is not part of the basic definition of the element and that modifies the understanding of the element in which it is contained and/or the understanding of the containing element's descendants. Usually modifier elements provide negation or qualification. To make the use of extensions safe and managable, there is a strict set of governance applied to the definition and use of extensions. Though any implementer can define an extension, there is a set of requirements that SHALL be met as part of the definition of the extension. Applications processing a resource are required to check for modifier extensions.

                  Modifier extensions SHALL NOT change the meaning of any elements on Resource or DomainResource (including cannot change the meaning of modifierExtension itself).

                  КороткийExtensions that cannot be ignored even if unrecognized
                  Комментарии

                  There can be no stigma associated with the use of extensions by any application, project, or standard - regardless of the institution or jurisdiction that uses or defines the extensions. The use of extensions is what allows the FHIR specification to retain a core level of simplicity for everyone.

                  Контроль0..*
                  ТипExtension
                  Модификаторtrue потому что Modifier extensions are expected to modify the meaning or interpretation of the element that contains them
                  Summarytrue
                  Требования

                  Modifier extensions allow for extensions that cannot be safely ignored to be clearly distinguished from the vast majority of extensions which can be safely ignored. This promotes interoperability by eliminating the need for implementers to prohibit the presence of extensions. For further information, see the definition of modifier extensions.

                  Альтернативные именаextensions, user content, modifiers
                  Инвариантыele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
                  ext-1: Must have either extensions or value[x], not both (extension.exists() != value.exists())
                  140. Observation.component.code
                  Определение

                  Describes what was observed. Sometimes this is called the observation "code".

                  КороткийType of component observation (code / type)
                  Комментарии

                  All code-value and component.code-component.value pairs need to be taken into account to correctly understand the meaning of the observation.

                  Контроль1..1
                  На этот элемент влияют следующие инварианты: obs-7
                  ПривязкаКоды СЛЕДУЕТ взять из ObservationCodesVS (0.12.0)
                  (preferred to https://terminology.dhp.uz/fhir/core/ValueSet/observation-codes-vs|0.12.0)
                  ТипCodeableConcept
                  Модификаторfalse
                  Требуется поддержкаtrue
                  Summarytrue
                  Требования

                  Knowing what kind of observation is being made is essential to understanding the observation.

                  Инвариантыele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
                  142. Observation.component.value[x]
                  Определение

                  The information determined as a result of making the observation, if the information has a simple value.

                  КороткийActual component result
                  Комментарии

                  Used when observation has a set of component observations:

                  • An observation may have both a value (e.g. an Apgar score) and component observations (the observations from which the Apgar score was derived).
                  • If a value is present, the datatype for this element should be determined by the code.
                  • CodeableConcept with just a text would be used instead of a string if the field was usually coded, or if the type associated with the code defines a coded value.
                  • Attachment is used if the observation result value is a binary file such as an image. If the observation result value is derived from the binary file (for example 'X' detected and here is the the proof in this image), the binary file may be directly represented using DocumentReference and referenced by derivedFrom.
                  • If a value is present, the datatype for this element should be determined by the code.
                  • CodeableConcept with just a text would be used instead of a string if the field was usually coded, or if the type associated with the code defines a coded value.
                  • Attachment is used if the observation result value is a binary file such as an image. If the observation result value is derived from the binary file (for example 'X' detected and here is the the proof in this image), the binary file may be directly represented using DocumentReference and referenced by derivedFrom.
                  • The usage of valueReference is restricted to the MolecularSequence resource when used as a definitional resource, not as a patient-specific finding. .
                  • For additional guidance, see the Notes section below.
                  Контроль0..1
                  ТипВыбор: Quantity, CodeableConcept, string, boolean, integer, Range, Ratio, SampledData, time, dateTime, Period, Attachment, Reference(MolecularSequence)
                  [x] ЗаметкаСмотретьВыбор типов данныхдля дополнительной информации о том, как использовать [x]
                  Модификаторfalse
                  Примитивное значениеЭтот примитивный элемент может присутствовать или отсутствовать, или быть замененным расширением
                  Требуется поддержкаtrue
                  Необходимо поддерживать типыНет обязательных правил поддержки выбора типов/профилей
                  Summarytrue
                  Требования

                  An observation exists to have a value, though it might not if it is in error, or if it represents a group of observations.

                  Инвариантыele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
                  144. Observation.component.dataAbsentReason
                  Определение

                  Provides a reason why the expected value in the element Observation.component.value[x] is missing.

                  КороткийWhy the component result is missing
                  Комментарии

                  "Null" or exceptional values can be represented two ways in FHIR Observations. One way is to simply include them in the value set and represent the exceptions in the value. For example, measurement values for a serology test could be "detected", "not detected", "inconclusive", or "test not done".

                  The alternate way is to use the value element for actual observations and use the explicit dataAbsentReason element to record exceptional values. For example, the dataAbsentReason code "error" could be used when the measurement was not completed. Because of these options, use-case agreements are required to interpret general observations for exceptional values.

                  Контроль0..1
                  ПривязкаЕсли они не подходят, эти коды ДОЛЖНЫ быть взяты из DataAbsentReasonVS (0.12.0)
                  (extensible to https://terminology.dhp.uz/fhir/core/ValueSet/data-absent-reason-vs|0.12.0)
                  ТипCodeableConcept
                  Модификаторfalse
                  Требуется поддержкаfalse
                  Summaryfalse
                  Требования

                  For many results it is necessary to handle exceptional values in measurements.

                  Инвариантыele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
                  146. Observation.component.interpretation
                  Определение

                  A categorical assessment of an observation value. For example, high, low, normal.

                  КороткийHigh, low, normal, etc
                  Комментарии

                  Historically used for laboratory results (known as 'abnormal flag' ), its use extends to other use cases where coded interpretations are relevant. Often reported as one or more simple compact codes this element is often placed adjacent to the result value in reports and flow sheets to signal the meaning/normalcy status of the result.

                  Контроль0..*
                  ПривязкаЕсли они не подходят, эти коды ДОЛЖНЫ быть взяты из ObservationInterpretationVS (0.12.0)
                  (extensible to https://terminology.dhp.uz/fhir/core/ValueSet/observation-interpretation-vs|0.12.0)
                  ТипCodeableConcept
                  Модификаторfalse
                  Требуется поддержкаfalse
                  Summaryfalse
                  Требования

                  For some results, particularly numeric results, an interpretation is necessary to fully understand the significance of a result.

                  Альтернативные именаAbnormal Flag
                  Инвариантыele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
                  148. Observation.component.referenceRange
                  Определение

                  Guidance on how to interpret the value by comparison to a normal or recommended range.

                  КороткийProvides guide for interpretation of component result
                  Комментарии

                  Most observations only have one generic reference range. Systems MAY choose to restrict to only supplying the relevant reference range based on knowledge about the patient (e.g., specific to the patient's age, gender, weight and other factors), but this might not be possible or appropriate. Whenever more than one reference range is supplied, the differences between them SHOULD be provided in the reference range and/or age properties.

                  Контроль0..*
                  ТипСмотретьttp://hl7.org/fhir/StructureDefinition/Observation#Observation.referenceRange
                  Модификаторfalse
                  Требуется поддержкаfalse
                  Summaryfalse
                  Требования

                  Knowing what values are considered "normal" can help evaluate the significance of a particular result. Need to be able to provide multiple reference ranges for different contexts.

                  Инвариантыele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
                  150. Observation.component:transformationZone
                  Название разрезаtransformationZone
                  Определение

                  Some observations have multiple component observations. These component observations are expressed as separate code value pairs that share the same attributes. Examples include systolic and diastolic component observations for blood pressure measurement and multiple component observations for genetics observations.

                  КороткийCervical transformation zone type (colposcopy)
                  Комментарии

                  For a discussion on the ways Observations can be assembled in groups together see Notes below.

                  Контроль0..0
                  На этот элемент влияют следующие инварианты: obs-7
                  ТипBackboneElement
                  Модификаторfalse
                  Требуется поддержкаtrue
                  Summarytrue
                  Требования

                  Component observations share the same attributes in the Observation resource as the primary observation and are always treated a part of a single observation (they are not separable). However, the reference range for the primary observation value is not inherited by the component values and is required when appropriate for each component observation.

                  Инвариантыele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
                  160. Observation.component:birads
                  Название разрезаbirads
                  Определение

                  Some observations have multiple component observations. These component observations are expressed as separate code value pairs that share the same attributes. Examples include systolic and diastolic component observations for blood pressure measurement and multiple component observations for genetics observations.

                  КороткийBI-RADS assessment category (mammography)
                  Комментарии

                  For a discussion on the ways Observations can be assembled in groups together see Notes below.

                  Контроль0..1
                  На этот элемент влияют следующие инварианты: obs-7
                  ТипBackboneElement
                  Модификаторfalse
                  Требуется поддержкаtrue
                  Summarytrue
                  Требования

                  Component observations share the same attributes in the Observation resource as the primary observation and are always treated a part of a single observation (they are not separable). However, the reference range for the primary observation value is not inherited by the component values and is required when appropriate for each component observation.

                  Инвариантыele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
                  162. Observation.component:birads.id
                  Определение

                  Unique id for the element within a resource (for internal references). This may be any string value that does not contain spaces.

                  КороткийUnique id for inter-element referencing
                  Контроль0..1
                  На этот элемент влияют следующие инварианты: ele-1
                  Типstring
                  Модификаторfalse
                  Формат XMLВ формате XML это свойство представлено в качестве атрибута.
                  Summaryfalse
                  164. Observation.component:birads.extension
                  Определение

                  May be used to represent additional information that is not part of the basic definition of the element. To make the use of extensions safe and managable, there is a strict set of governance applied to the definition and use of extensions. Though any implementer can define an extension, there is a set of requirements that SHALL be met as part of the definition of the extension.

                  КороткийAdditional content defined by implementations
                  Комментарии

                  There can be no stigma associated with the use of extensions by any application, project, or standard - regardless of the institution or jurisdiction that uses or defines the extensions. The use of extensions is what allows the FHIR specification to retain a core level of simplicity for everyone.

                  Контроль0..*
                  ТипExtension
                  Модификаторfalse
                  Summaryfalse
                  Альтернативные именаextensions, user content
                  Инвариантыele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
                  ext-1: Must have either extensions or value[x], not both (extension.exists() != value.exists())
                  166. Observation.component:birads.modifierExtension
                  Определение

                  May be used to represent additional information that is not part of the basic definition of the element and that modifies the understanding of the element in which it is contained and/or the understanding of the containing element's descendants. Usually modifier elements provide negation or qualification. To make the use of extensions safe and managable, there is a strict set of governance applied to the definition and use of extensions. Though any implementer can define an extension, there is a set of requirements that SHALL be met as part of the definition of the extension. Applications processing a resource are required to check for modifier extensions.

                  Modifier extensions SHALL NOT change the meaning of any elements on Resource or DomainResource (including cannot change the meaning of modifierExtension itself).

                  КороткийExtensions that cannot be ignored even if unrecognized
                  Комментарии

                  There can be no stigma associated with the use of extensions by any application, project, or standard - regardless of the institution or jurisdiction that uses or defines the extensions. The use of extensions is what allows the FHIR specification to retain a core level of simplicity for everyone.

                  Контроль0..*
                  ТипExtension
                  Модификаторtrue потому что Modifier extensions are expected to modify the meaning or interpretation of the element that contains them
                  Summarytrue
                  Требования

                  Modifier extensions allow for extensions that cannot be safely ignored to be clearly distinguished from the vast majority of extensions which can be safely ignored. This promotes interoperability by eliminating the need for implementers to prohibit the presence of extensions. For further information, see the definition of modifier extensions.

                  Альтернативные именаextensions, user content, modifiers
                  Инвариантыele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
                  ext-1: Must have either extensions or value[x], not both (extension.exists() != value.exists())
                  168. Observation.component:birads.code
                  Определение

                  Describes what was observed. Sometimes this is called the observation "code".

                  КороткийType of component observation (code / type)
                  Комментарии

                  All code-value and component.code-component.value pairs need to be taken into account to correctly understand the meaning of the observation.

                  Контроль1..1
                  На этот элемент влияют следующие инварианты: obs-7
                  ПривязкаКоды СЛЕДУЕТ взять из ObservationCodesVS (0.12.0)
                  (preferred to https://terminology.dhp.uz/fhir/core/ValueSet/observation-codes-vs|0.12.0)
                  ТипCodeableConcept
                  Модификаторfalse
                  Требуется поддержкаtrue
                  Summarytrue
                  Требования

                  Knowing what kind of observation is being made is essential to understanding the observation.

                  Значение шаблона{
                    "coding" : [{
                      "system" : "http://snomed.info/sct",
                      "code" : "1348266008"
                    }]
                  }
                  Инвариантыele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
                  170. Observation.component:birads.value[x]
                  Определение

                  The information determined as a result of making the observation, if the information has a simple value.

                  КороткийActual component result
                  Комментарии

                  Used when observation has a set of component observations:

                  • An observation may have both a value (e.g. an Apgar score) and component observations (the observations from which the Apgar score was derived).
                  • If a value is present, the datatype for this element should be determined by the code.
                  • CodeableConcept with just a text would be used instead of a string if the field was usually coded, or if the type associated with the code defines a coded value.
                  • Attachment is used if the observation result value is a binary file such as an image. If the observation result value is derived from the binary file (for example 'X' detected and here is the the proof in this image), the binary file may be directly represented using DocumentReference and referenced by derivedFrom.
                  • If a value is present, the datatype for this element should be determined by the code.
                  • CodeableConcept with just a text would be used instead of a string if the field was usually coded, or if the type associated with the code defines a coded value.
                  • Attachment is used if the observation result value is a binary file such as an image. If the observation result value is derived from the binary file (for example 'X' detected and here is the the proof in this image), the binary file may be directly represented using DocumentReference and referenced by derivedFrom.
                  • The usage of valueReference is restricted to the MolecularSequence resource when used as a definitional resource, not as a patient-specific finding. .
                  • For additional guidance, see the Notes section below.
                  Контроль0..1
                  ПривязкаКоды ДОЛЖНЫ быть взяты из ScreeningBiradsVS (0.12.1)
                  (required to https://terminology.dhp.uz/fhir/integrations/ValueSet/screening-birads-vs|0.12.1)
                  ТипCodeableConcept
                  [x] ЗаметкаСмотретьВыбор типов данныхдля дополнительной информации о том, как использовать [x]
                  Модификаторfalse
                  Требуется поддержкаtrue
                  Summarytrue
                  Требования

                  An observation exists to have a value, though it might not if it is in error, or if it represents a group of observations.

                  Инвариантыele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
                  172. Observation.component:birads.dataAbsentReason
                  Определение

                  Provides a reason why the expected value in the element Observation.component.value[x] is missing.

                  КороткийWhy the component result is missing
                  Комментарии

                  "Null" or exceptional values can be represented two ways in FHIR Observations. One way is to simply include them in the value set and represent the exceptions in the value. For example, measurement values for a serology test could be "detected", "not detected", "inconclusive", or "test not done".

                  The alternate way is to use the value element for actual observations and use the explicit dataAbsentReason element to record exceptional values. For example, the dataAbsentReason code "error" could be used when the measurement was not completed. Because of these options, use-case agreements are required to interpret general observations for exceptional values.

                  Контроль0..1
                  ПривязкаЕсли они не подходят, эти коды ДОЛЖНЫ быть взяты из DataAbsentReasonVS (0.12.0)
                  (extensible to https://terminology.dhp.uz/fhir/core/ValueSet/data-absent-reason-vs|0.12.0)
                  ТипCodeableConcept
                  Модификаторfalse
                  Требуется поддержкаfalse
                  Summaryfalse
                  Требования

                  For many results it is necessary to handle exceptional values in measurements.

                  Инвариантыele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
                  174. Observation.component:birads.interpretation
                  Определение

                  A categorical assessment of an observation value. For example, high, low, normal.

                  КороткийHigh, low, normal, etc
                  Комментарии

                  Historically used for laboratory results (known as 'abnormal flag' ), its use extends to other use cases where coded interpretations are relevant. Often reported as one or more simple compact codes this element is often placed adjacent to the result value in reports and flow sheets to signal the meaning/normalcy status of the result.

                  Контроль0..*
                  ПривязкаЕсли они не подходят, эти коды ДОЛЖНЫ быть взяты из ObservationInterpretationVS (0.12.0)
                  (extensible to https://terminology.dhp.uz/fhir/core/ValueSet/observation-interpretation-vs|0.12.0)
                  ТипCodeableConcept
                  Модификаторfalse
                  Требуется поддержкаfalse
                  Summaryfalse
                  Требования

                  For some results, particularly numeric results, an interpretation is necessary to fully understand the significance of a result.

                  Альтернативные именаAbnormal Flag
                  Инвариантыele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
                  176. Observation.component:birads.referenceRange
                  Определение

                  Guidance on how to interpret the value by comparison to a normal or recommended range.

                  КороткийProvides guide for interpretation of component result
                  Комментарии

                  Most observations only have one generic reference range. Systems MAY choose to restrict to only supplying the relevant reference range based on knowledge about the patient (e.g., specific to the patient's age, gender, weight and other factors), but this might not be possible or appropriate. Whenever more than one reference range is supplied, the differences between them SHOULD be provided in the reference range and/or age properties.

                  Контроль0..*
                  ТипСмотретьttp://hl7.org/fhir/StructureDefinition/Observation#Observation.referenceRange
                  Модификаторfalse
                  Требуется поддержкаfalse
                  Summaryfalse
                  Требования

                  Knowing what values are considered "normal" can help evaluate the significance of a particular result. Need to be able to provide multiple reference ranges for different contexts.

                  Инвариантыele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
                  178. Observation.component:breastDensity
                  Название разрезаbreastDensity
                  Определение

                  Some observations have multiple component observations. These component observations are expressed as separate code value pairs that share the same attributes. Examples include systolic and diastolic component observations for blood pressure measurement and multiple component observations for genetics observations.

                  КороткийMammographic breast density (mammography)
                  Комментарии

                  For a discussion on the ways Observations can be assembled in groups together see Notes below.

                  Контроль0..0
                  На этот элемент влияют следующие инварианты: obs-7
                  ТипBackboneElement
                  Модификаторfalse
                  Требуется поддержкаtrue
                  Summarytrue
                  Требования

                  Component observations share the same attributes in the Observation resource as the primary observation and are always treated a part of a single observation (they are not separable). However, the reference range for the primary observation value is not inherited by the component values and is required when appropriate for each component observation.

                  Инвариантыele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
                  188. Observation.component:imageQuality
                  Название разрезаimageQuality
                  Определение

                  Some observations have multiple component observations. These component observations are expressed as separate code value pairs that share the same attributes. Examples include systolic and diastolic component observations for blood pressure measurement and multiple component observations for genetics observations.

                  КороткийImage quality (mammography)
                  Комментарии

                  For a discussion on the ways Observations can be assembled in groups together see Notes below.

                  Контроль0..0
                  На этот элемент влияют следующие инварианты: obs-7
                  ТипBackboneElement
                  Модификаторfalse
                  Требуется поддержкаtrue
                  Summarytrue
                  Требования

                  Component observations share the same attributes in the Observation resource as the primary observation and are always treated a part of a single observation (they are not separable). However, the reference range for the primary observation value is not inherited by the component values and is required when appropriate for each component observation.

                  Инвариантыele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
                  198. Observation.component:breastFinding
                  Название разрезаbreastFinding
                  Определение

                  Some observations have multiple component observations. These component observations are expressed as separate code value pairs that share the same attributes. Examples include systolic and diastolic component observations for blood pressure measurement and multiple component observations for genetics observations.

                  КороткийBreast ultrasound finding
                  Комментарии

                  For a discussion on the ways Observations can be assembled in groups together see Notes below.

                  Контроль0..*
                  На этот элемент влияют следующие инварианты: obs-7
                  ТипBackboneElement
                  Модификаторfalse
                  Требуется поддержкаtrue
                  Summarytrue
                  Требования

                  Component observations share the same attributes in the Observation resource as the primary observation and are always treated a part of a single observation (they are not separable). However, the reference range for the primary observation value is not inherited by the component values and is required when appropriate for each component observation.

                  Инвариантыele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
                  200. Observation.component:breastFinding.id
                  Определение

                  Unique id for the element within a resource (for internal references). This may be any string value that does not contain spaces.

                  КороткийUnique id for inter-element referencing
                  Контроль0..1
                  На этот элемент влияют следующие инварианты: ele-1
                  Типstring
                  Модификаторfalse
                  Формат XMLВ формате XML это свойство представлено в качестве атрибута.
                  Summaryfalse
                  202. Observation.component:breastFinding.extension
                  Определение

                  May be used to represent additional information that is not part of the basic definition of the element. To make the use of extensions safe and managable, there is a strict set of governance applied to the definition and use of extensions. Though any implementer can define an extension, there is a set of requirements that SHALL be met as part of the definition of the extension.

                  КороткийAdditional content defined by implementations
                  Комментарии

                  There can be no stigma associated with the use of extensions by any application, project, or standard - regardless of the institution or jurisdiction that uses or defines the extensions. The use of extensions is what allows the FHIR specification to retain a core level of simplicity for everyone.

                  Контроль0..*
                  ТипExtension
                  Модификаторfalse
                  Summaryfalse
                  Альтернативные именаextensions, user content
                  Инвариантыele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
                  ext-1: Must have either extensions or value[x], not both (extension.exists() != value.exists())
                  204. Observation.component:breastFinding.modifierExtension
                  Определение

                  May be used to represent additional information that is not part of the basic definition of the element and that modifies the understanding of the element in which it is contained and/or the understanding of the containing element's descendants. Usually modifier elements provide negation or qualification. To make the use of extensions safe and managable, there is a strict set of governance applied to the definition and use of extensions. Though any implementer can define an extension, there is a set of requirements that SHALL be met as part of the definition of the extension. Applications processing a resource are required to check for modifier extensions.

                  Modifier extensions SHALL NOT change the meaning of any elements on Resource or DomainResource (including cannot change the meaning of modifierExtension itself).

                  КороткийExtensions that cannot be ignored even if unrecognized
                  Комментарии

                  There can be no stigma associated with the use of extensions by any application, project, or standard - regardless of the institution or jurisdiction that uses or defines the extensions. The use of extensions is what allows the FHIR specification to retain a core level of simplicity for everyone.

                  Контроль0..*
                  ТипExtension
                  Модификаторtrue потому что Modifier extensions are expected to modify the meaning or interpretation of the element that contains them
                  Summarytrue
                  Требования

                  Modifier extensions allow for extensions that cannot be safely ignored to be clearly distinguished from the vast majority of extensions which can be safely ignored. This promotes interoperability by eliminating the need for implementers to prohibit the presence of extensions. For further information, see the definition of modifier extensions.

                  Альтернативные именаextensions, user content, modifiers
                  Инвариантыele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
                  ext-1: Must have either extensions or value[x], not both (extension.exists() != value.exists())
                  206. Observation.component:breastFinding.code
                  Определение

                  Describes what was observed. Sometimes this is called the observation "code".

                  КороткийType of component observation (code / type)
                  Комментарии

                  All code-value and component.code-component.value pairs need to be taken into account to correctly understand the meaning of the observation.

                  Контроль1..1
                  На этот элемент влияют следующие инварианты: obs-7
                  ПривязкаКоды СЛЕДУЕТ взять из ObservationCodesVS (0.12.0)
                  (preferred to https://terminology.dhp.uz/fhir/core/ValueSet/observation-codes-vs|0.12.0)
                  ТипCodeableConcept
                  Модификаторfalse
                  Требуется поддержкаtrue
                  Summarytrue
                  Требования

                  Knowing what kind of observation is being made is essential to understanding the observation.

                  Значение шаблона{
                    "coding" : [{
                      "system" : "https://terminology.dhp.uz/fhir/integrations/CodeSystem/screening-specialized-observation-parameter-cs",
                      "code" : "scrn-0073-00004"
                    }]
                  }
                  Инвариантыele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
                  208. Observation.component:breastFinding.value[x]
                  Определение

                  The information determined as a result of making the observation, if the information has a simple value.

                  КороткийActual component result
                  Комментарии

                  Used when observation has a set of component observations:

                  • An observation may have both a value (e.g. an Apgar score) and component observations (the observations from which the Apgar score was derived).
                  • If a value is present, the datatype for this element should be determined by the code.
                  • CodeableConcept with just a text would be used instead of a string if the field was usually coded, or if the type associated with the code defines a coded value.
                  • Attachment is used if the observation result value is a binary file such as an image. If the observation result value is derived from the binary file (for example 'X' detected and here is the the proof in this image), the binary file may be directly represented using DocumentReference and referenced by derivedFrom.
                  • If a value is present, the datatype for this element should be determined by the code.
                  • CodeableConcept with just a text would be used instead of a string if the field was usually coded, or if the type associated with the code defines a coded value.
                  • Attachment is used if the observation result value is a binary file such as an image. If the observation result value is derived from the binary file (for example 'X' detected and here is the the proof in this image), the binary file may be directly represented using DocumentReference and referenced by derivedFrom.
                  • The usage of valueReference is restricted to the MolecularSequence resource when used as a definitional resource, not as a patient-specific finding. .
                  • For additional guidance, see the Notes section below.
                  Контроль0..1
                  ПривязкаКоды ДОЛЖНЫ быть взяты из ScreeningBreastFindingVS (0.12.1)
                  (required to https://terminology.dhp.uz/fhir/integrations/ValueSet/screening-breast-finding-vs|0.12.1)
                  ТипCodeableConcept
                  [x] ЗаметкаСмотретьВыбор типов данныхдля дополнительной информации о том, как использовать [x]
                  Модификаторfalse
                  Требуется поддержкаtrue
                  Summarytrue
                  Требования

                  An observation exists to have a value, though it might not if it is in error, or if it represents a group of observations.

                  Инвариантыele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
                  210. Observation.component:breastFinding.dataAbsentReason
                  Определение

                  Provides a reason why the expected value in the element Observation.component.value[x] is missing.

                  КороткийWhy the component result is missing
                  Комментарии

                  "Null" or exceptional values can be represented two ways in FHIR Observations. One way is to simply include them in the value set and represent the exceptions in the value. For example, measurement values for a serology test could be "detected", "not detected", "inconclusive", or "test not done".

                  The alternate way is to use the value element for actual observations and use the explicit dataAbsentReason element to record exceptional values. For example, the dataAbsentReason code "error" could be used when the measurement was not completed. Because of these options, use-case agreements are required to interpret general observations for exceptional values.

                  Контроль0..1
                  ПривязкаЕсли они не подходят, эти коды ДОЛЖНЫ быть взяты из DataAbsentReasonVS (0.12.0)
                  (extensible to https://terminology.dhp.uz/fhir/core/ValueSet/data-absent-reason-vs|0.12.0)
                  ТипCodeableConcept
                  Модификаторfalse
                  Требуется поддержкаfalse
                  Summaryfalse
                  Требования

                  For many results it is necessary to handle exceptional values in measurements.

                  Инвариантыele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
                  212. Observation.component:breastFinding.interpretation
                  Определение

                  A categorical assessment of an observation value. For example, high, low, normal.

                  КороткийHigh, low, normal, etc
                  Комментарии

                  Historically used for laboratory results (known as 'abnormal flag' ), its use extends to other use cases where coded interpretations are relevant. Often reported as one or more simple compact codes this element is often placed adjacent to the result value in reports and flow sheets to signal the meaning/normalcy status of the result.

                  Контроль0..*
                  ПривязкаЕсли они не подходят, эти коды ДОЛЖНЫ быть взяты из ObservationInterpretationVS (0.12.0)
                  (extensible to https://terminology.dhp.uz/fhir/core/ValueSet/observation-interpretation-vs|0.12.0)
                  ТипCodeableConcept
                  Модификаторfalse
                  Требуется поддержкаfalse
                  Summaryfalse
                  Требования

                  For some results, particularly numeric results, an interpretation is necessary to fully understand the significance of a result.

                  Альтернативные именаAbnormal Flag
                  Инвариантыele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
                  214. Observation.component:breastFinding.referenceRange
                  Определение

                  Guidance on how to interpret the value by comparison to a normal or recommended range.

                  КороткийProvides guide for interpretation of component result
                  Комментарии

                  Most observations only have one generic reference range. Systems MAY choose to restrict to only supplying the relevant reference range based on knowledge about the patient (e.g., specific to the patient's age, gender, weight and other factors), but this might not be possible or appropriate. Whenever more than one reference range is supplied, the differences between them SHOULD be provided in the reference range and/or age properties.

                  Контроль0..*
                  ТипСмотретьttp://hl7.org/fhir/StructureDefinition/Observation#Observation.referenceRange
                  Модификаторfalse
                  Требуется поддержкаfalse
                  Summaryfalse
                  Требования

                  Knowing what values are considered "normal" can help evaluate the significance of a particular result. Need to be able to provide multiple reference ranges for different contexts.

                  Инвариантыele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
                  216. Observation.component:breastSymmetry
                  Название разрезаbreastSymmetry
                  Определение

                  Some observations have multiple component observations. These component observations are expressed as separate code value pairs that share the same attributes. Examples include systolic and diastolic component observations for blood pressure measurement and multiple component observations for genetics observations.

                  КороткийBreast symmetry
                  Комментарии

                  For a discussion on the ways Observations can be assembled in groups together see Notes below.

                  Контроль0..1
                  На этот элемент влияют следующие инварианты: obs-7
                  ТипBackboneElement
                  Модификаторfalse
                  Требуется поддержкаtrue
                  Summarytrue
                  Требования

                  Component observations share the same attributes in the Observation resource as the primary observation and are always treated a part of a single observation (they are not separable). However, the reference range for the primary observation value is not inherited by the component values and is required when appropriate for each component observation.

                  Инвариантыele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
                  218. Observation.component:breastSymmetry.id
                  Определение

                  Unique id for the element within a resource (for internal references). This may be any string value that does not contain spaces.

                  КороткийUnique id for inter-element referencing
                  Контроль0..1
                  На этот элемент влияют следующие инварианты: ele-1
                  Типstring
                  Модификаторfalse
                  Формат XMLВ формате XML это свойство представлено в качестве атрибута.
                  Summaryfalse
                  220. Observation.component:breastSymmetry.extension
                  Определение

                  May be used to represent additional information that is not part of the basic definition of the element. To make the use of extensions safe and managable, there is a strict set of governance applied to the definition and use of extensions. Though any implementer can define an extension, there is a set of requirements that SHALL be met as part of the definition of the extension.

                  КороткийAdditional content defined by implementations
                  Комментарии

                  There can be no stigma associated with the use of extensions by any application, project, or standard - regardless of the institution or jurisdiction that uses or defines the extensions. The use of extensions is what allows the FHIR specification to retain a core level of simplicity for everyone.

                  Контроль0..*
                  ТипExtension
                  Модификаторfalse
                  Summaryfalse
                  Альтернативные именаextensions, user content
                  Инвариантыele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
                  ext-1: Must have either extensions or value[x], not both (extension.exists() != value.exists())
                  222. Observation.component:breastSymmetry.modifierExtension
                  Определение

                  May be used to represent additional information that is not part of the basic definition of the element and that modifies the understanding of the element in which it is contained and/or the understanding of the containing element's descendants. Usually modifier elements provide negation or qualification. To make the use of extensions safe and managable, there is a strict set of governance applied to the definition and use of extensions. Though any implementer can define an extension, there is a set of requirements that SHALL be met as part of the definition of the extension. Applications processing a resource are required to check for modifier extensions.

                  Modifier extensions SHALL NOT change the meaning of any elements on Resource or DomainResource (including cannot change the meaning of modifierExtension itself).

                  КороткийExtensions that cannot be ignored even if unrecognized
                  Комментарии

                  There can be no stigma associated with the use of extensions by any application, project, or standard - regardless of the institution or jurisdiction that uses or defines the extensions. The use of extensions is what allows the FHIR specification to retain a core level of simplicity for everyone.

                  Контроль0..*
                  ТипExtension
                  Модификаторtrue потому что Modifier extensions are expected to modify the meaning or interpretation of the element that contains them
                  Summarytrue
                  Требования

                  Modifier extensions allow for extensions that cannot be safely ignored to be clearly distinguished from the vast majority of extensions which can be safely ignored. This promotes interoperability by eliminating the need for implementers to prohibit the presence of extensions. For further information, see the definition of modifier extensions.

                  Альтернативные именаextensions, user content, modifiers
                  Инвариантыele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
                  ext-1: Must have either extensions or value[x], not both (extension.exists() != value.exists())
                  224. Observation.component:breastSymmetry.code
                  Определение

                  Describes what was observed. Sometimes this is called the observation "code".

                  КороткийType of component observation (code / type)
                  Комментарии

                  All code-value and component.code-component.value pairs need to be taken into account to correctly understand the meaning of the observation.

                  Контроль1..1
                  На этот элемент влияют следующие инварианты: obs-7
                  ПривязкаКоды СЛЕДУЕТ взять из ObservationCodesVS (0.12.0)
                  (preferred to https://terminology.dhp.uz/fhir/core/ValueSet/observation-codes-vs|0.12.0)
                  ТипCodeableConcept
                  Модификаторfalse
                  Требуется поддержкаtrue
                  Summarytrue
                  Требования

                  Knowing what kind of observation is being made is essential to understanding the observation.

                  Значение шаблона{
                    "coding" : [{
                      "system" : "https://terminology.dhp.uz/fhir/integrations/CodeSystem/screening-ultrasound-parameter-cs",
                      "code" : "scrn-0052-00004"
                    }]
                  }
                  Инвариантыele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
                  226. Observation.component:breastSymmetry.value[x]
                  Определение

                  The information determined as a result of making the observation, if the information has a simple value.

                  КороткийActual component result
                  Комментарии

                  Used when observation has a set of component observations:

                  • An observation may have both a value (e.g. an Apgar score) and component observations (the observations from which the Apgar score was derived).
                  • If a value is present, the datatype for this element should be determined by the code.
                  • CodeableConcept with just a text would be used instead of a string if the field was usually coded, or if the type associated with the code defines a coded value.
                  • Attachment is used if the observation result value is a binary file such as an image. If the observation result value is derived from the binary file (for example 'X' detected and here is the the proof in this image), the binary file may be directly represented using DocumentReference and referenced by derivedFrom.
                  • If a value is present, the datatype for this element should be determined by the code.
                  • CodeableConcept with just a text would be used instead of a string if the field was usually coded, or if the type associated with the code defines a coded value.
                  • Attachment is used if the observation result value is a binary file such as an image. If the observation result value is derived from the binary file (for example 'X' detected and here is the the proof in this image), the binary file may be directly represented using DocumentReference and referenced by derivedFrom.
                  • The usage of valueReference is restricted to the MolecularSequence resource when used as a definitional resource, not as a patient-specific finding. .
                  • For additional guidance, see the Notes section below.
                  Контроль0..1
                  ПривязкаКоды ДОЛЖНЫ быть взяты из ScreeningUltrasoundBreastSymmetryVS (0.12.1)
                  (required to https://terminology.dhp.uz/fhir/integrations/ValueSet/screening-ultrasound-breast-symmetry-vs|0.12.1)
                  ТипCodeableConcept
                  [x] ЗаметкаСмотретьВыбор типов данныхдля дополнительной информации о том, как использовать [x]
                  Модификаторfalse
                  Требуется поддержкаtrue
                  Summarytrue
                  Требования

                  An observation exists to have a value, though it might not if it is in error, or if it represents a group of observations.

                  Инвариантыele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
                  228. Observation.component:breastSymmetry.dataAbsentReason
                  Определение

                  Provides a reason why the expected value in the element Observation.component.value[x] is missing.

                  КороткийWhy the component result is missing
                  Комментарии

                  "Null" or exceptional values can be represented two ways in FHIR Observations. One way is to simply include them in the value set and represent the exceptions in the value. For example, measurement values for a serology test could be "detected", "not detected", "inconclusive", or "test not done".

                  The alternate way is to use the value element for actual observations and use the explicit dataAbsentReason element to record exceptional values. For example, the dataAbsentReason code "error" could be used when the measurement was not completed. Because of these options, use-case agreements are required to interpret general observations for exceptional values.

                  Контроль0..1
                  ПривязкаЕсли они не подходят, эти коды ДОЛЖНЫ быть взяты из DataAbsentReasonVS (0.12.0)
                  (extensible to https://terminology.dhp.uz/fhir/core/ValueSet/data-absent-reason-vs|0.12.0)
                  ТипCodeableConcept
                  Модификаторfalse
                  Требуется поддержкаfalse
                  Summaryfalse
                  Требования

                  For many results it is necessary to handle exceptional values in measurements.

                  Инвариантыele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
                  230. Observation.component:breastSymmetry.interpretation
                  Определение

                  A categorical assessment of an observation value. For example, high, low, normal.

                  КороткийHigh, low, normal, etc
                  Комментарии

                  Historically used for laboratory results (known as 'abnormal flag' ), its use extends to other use cases where coded interpretations are relevant. Often reported as one or more simple compact codes this element is often placed adjacent to the result value in reports and flow sheets to signal the meaning/normalcy status of the result.

                  Контроль0..*
                  ПривязкаЕсли они не подходят, эти коды ДОЛЖНЫ быть взяты из ObservationInterpretationVS (0.12.0)
                  (extensible to https://terminology.dhp.uz/fhir/core/ValueSet/observation-interpretation-vs|0.12.0)
                  ТипCodeableConcept
                  Модификаторfalse
                  Требуется поддержкаfalse
                  Summaryfalse
                  Требования

                  For some results, particularly numeric results, an interpretation is necessary to fully understand the significance of a result.

                  Альтернативные именаAbnormal Flag
                  Инвариантыele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
                  232. Observation.component:breastSymmetry.referenceRange
                  Определение

                  Guidance on how to interpret the value by comparison to a normal or recommended range.

                  КороткийProvides guide for interpretation of component result
                  Комментарии

                  Most observations only have one generic reference range. Systems MAY choose to restrict to only supplying the relevant reference range based on knowledge about the patient (e.g., specific to the patient's age, gender, weight and other factors), but this might not be possible or appropriate. Whenever more than one reference range is supplied, the differences between them SHOULD be provided in the reference range and/or age properties.

                  Контроль0..*
                  ТипСмотретьttp://hl7.org/fhir/StructureDefinition/Observation#Observation.referenceRange
                  Модификаторfalse
                  Требуется поддержкаfalse
                  Summaryfalse
                  Требования

                  Knowing what values are considered "normal" can help evaluate the significance of a particular result. Need to be able to provide multiple reference ranges for different contexts.

                  Инвариантыele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
                  234. Observation.component:acrComposition
                  Название разрезаacrComposition
                  Определение

                  Some observations have multiple component observations. These component observations are expressed as separate code value pairs that share the same attributes. Examples include systolic and diastolic component observations for blood pressure measurement and multiple component observations for genetics observations.

                  КороткийACR breast composition
                  Комментарии

                  For a discussion on the ways Observations can be assembled in groups together see Notes below.

                  Контроль0..1
                  На этот элемент влияют следующие инварианты: obs-7
                  ТипBackboneElement
                  Модификаторfalse
                  Требуется поддержкаtrue
                  Summarytrue
                  Требования

                  Component observations share the same attributes in the Observation resource as the primary observation and are always treated a part of a single observation (they are not separable). However, the reference range for the primary observation value is not inherited by the component values and is required when appropriate for each component observation.

                  Инвариантыele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
                  236. Observation.component:acrComposition.id
                  Определение

                  Unique id for the element within a resource (for internal references). This may be any string value that does not contain spaces.

                  КороткийUnique id for inter-element referencing
                  Контроль0..1
                  На этот элемент влияют следующие инварианты: ele-1
                  Типstring
                  Модификаторfalse
                  Формат XMLВ формате XML это свойство представлено в качестве атрибута.
                  Summaryfalse
                  238. Observation.component:acrComposition.extension
                  Определение

                  May be used to represent additional information that is not part of the basic definition of the element. To make the use of extensions safe and managable, there is a strict set of governance applied to the definition and use of extensions. Though any implementer can define an extension, there is a set of requirements that SHALL be met as part of the definition of the extension.

                  КороткийAdditional content defined by implementations
                  Комментарии

                  There can be no stigma associated with the use of extensions by any application, project, or standard - regardless of the institution or jurisdiction that uses or defines the extensions. The use of extensions is what allows the FHIR specification to retain a core level of simplicity for everyone.

                  Контроль0..*
                  ТипExtension
                  Модификаторfalse
                  Summaryfalse
                  Альтернативные именаextensions, user content
                  Инвариантыele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
                  ext-1: Must have either extensions or value[x], not both (extension.exists() != value.exists())
                  240. Observation.component:acrComposition.modifierExtension
                  Определение

                  May be used to represent additional information that is not part of the basic definition of the element and that modifies the understanding of the element in which it is contained and/or the understanding of the containing element's descendants. Usually modifier elements provide negation or qualification. To make the use of extensions safe and managable, there is a strict set of governance applied to the definition and use of extensions. Though any implementer can define an extension, there is a set of requirements that SHALL be met as part of the definition of the extension. Applications processing a resource are required to check for modifier extensions.

                  Modifier extensions SHALL NOT change the meaning of any elements on Resource or DomainResource (including cannot change the meaning of modifierExtension itself).

                  КороткийExtensions that cannot be ignored even if unrecognized
                  Комментарии

                  There can be no stigma associated with the use of extensions by any application, project, or standard - regardless of the institution or jurisdiction that uses or defines the extensions. The use of extensions is what allows the FHIR specification to retain a core level of simplicity for everyone.

                  Контроль0..*
                  ТипExtension
                  Модификаторtrue потому что Modifier extensions are expected to modify the meaning or interpretation of the element that contains them
                  Summarytrue
                  Требования

                  Modifier extensions allow for extensions that cannot be safely ignored to be clearly distinguished from the vast majority of extensions which can be safely ignored. This promotes interoperability by eliminating the need for implementers to prohibit the presence of extensions. For further information, see the definition of modifier extensions.

                  Альтернативные именаextensions, user content, modifiers
                  Инвариантыele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
                  ext-1: Must have either extensions or value[x], not both (extension.exists() != value.exists())
                  242. Observation.component:acrComposition.code
                  Определение

                  Describes what was observed. Sometimes this is called the observation "code".

                  КороткийType of component observation (code / type)
                  Комментарии

                  All code-value and component.code-component.value pairs need to be taken into account to correctly understand the meaning of the observation.

                  Контроль1..1
                  На этот элемент влияют следующие инварианты: obs-7
                  ПривязкаКоды СЛЕДУЕТ взять из ObservationCodesVS (0.12.0)
                  (preferred to https://terminology.dhp.uz/fhir/core/ValueSet/observation-codes-vs|0.12.0)
                  ТипCodeableConcept
                  Модификаторfalse
                  Требуется поддержкаtrue
                  Summarytrue
                  Требования

                  Knowing what kind of observation is being made is essential to understanding the observation.

                  Значение шаблона{
                    "coding" : [{
                      "system" : "https://terminology.dhp.uz/fhir/integrations/CodeSystem/screening-ultrasound-parameter-cs",
                      "code" : "scrn-0052-00005"
                    }]
                  }
                  Инвариантыele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
                  244. Observation.component:acrComposition.value[x]
                  Определение

                  The information determined as a result of making the observation, if the information has a simple value.

                  КороткийActual component result
                  Комментарии

                  Used when observation has a set of component observations:

                  • An observation may have both a value (e.g. an Apgar score) and component observations (the observations from which the Apgar score was derived).
                  • If a value is present, the datatype for this element should be determined by the code.
                  • CodeableConcept with just a text would be used instead of a string if the field was usually coded, or if the type associated with the code defines a coded value.
                  • Attachment is used if the observation result value is a binary file such as an image. If the observation result value is derived from the binary file (for example 'X' detected and here is the the proof in this image), the binary file may be directly represented using DocumentReference and referenced by derivedFrom.
                  • If a value is present, the datatype for this element should be determined by the code.
                  • CodeableConcept with just a text would be used instead of a string if the field was usually coded, or if the type associated with the code defines a coded value.
                  • Attachment is used if the observation result value is a binary file such as an image. If the observation result value is derived from the binary file (for example 'X' detected and here is the the proof in this image), the binary file may be directly represented using DocumentReference and referenced by derivedFrom.
                  • The usage of valueReference is restricted to the MolecularSequence resource when used as a definitional resource, not as a patient-specific finding. .
                  • For additional guidance, see the Notes section below.
                  Контроль0..1
                  ПривязкаКоды ДОЛЖНЫ быть взяты из ScreeningUltrasoundAcrCompositionVS (0.12.1)
                  (required to https://terminology.dhp.uz/fhir/integrations/ValueSet/screening-ultrasound-acr-composition-vs|0.12.1)
                  ТипCodeableConcept
                  [x] ЗаметкаСмотретьВыбор типов данныхдля дополнительной информации о том, как использовать [x]
                  Модификаторfalse
                  Требуется поддержкаtrue
                  Summarytrue
                  Требования

                  An observation exists to have a value, though it might not if it is in error, or if it represents a group of observations.

                  Инвариантыele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
                  246. Observation.component:acrComposition.dataAbsentReason
                  Определение

                  Provides a reason why the expected value in the element Observation.component.value[x] is missing.

                  КороткийWhy the component result is missing
                  Комментарии

                  "Null" or exceptional values can be represented two ways in FHIR Observations. One way is to simply include them in the value set and represent the exceptions in the value. For example, measurement values for a serology test could be "detected", "not detected", "inconclusive", or "test not done".

                  The alternate way is to use the value element for actual observations and use the explicit dataAbsentReason element to record exceptional values. For example, the dataAbsentReason code "error" could be used when the measurement was not completed. Because of these options, use-case agreements are required to interpret general observations for exceptional values.

                  Контроль0..1
                  ПривязкаЕсли они не подходят, эти коды ДОЛЖНЫ быть взяты из DataAbsentReasonVS (0.12.0)
                  (extensible to https://terminology.dhp.uz/fhir/core/ValueSet/data-absent-reason-vs|0.12.0)
                  ТипCodeableConcept
                  Модификаторfalse
                  Требуется поддержкаfalse
                  Summaryfalse
                  Требования

                  For many results it is necessary to handle exceptional values in measurements.

                  Инвариантыele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
                  248. Observation.component:acrComposition.interpretation
                  Определение

                  A categorical assessment of an observation value. For example, high, low, normal.

                  КороткийHigh, low, normal, etc
                  Комментарии

                  Historically used for laboratory results (known as 'abnormal flag' ), its use extends to other use cases where coded interpretations are relevant. Often reported as one or more simple compact codes this element is often placed adjacent to the result value in reports and flow sheets to signal the meaning/normalcy status of the result.

                  Контроль0..*
                  ПривязкаЕсли они не подходят, эти коды ДОЛЖНЫ быть взяты из ObservationInterpretationVS (0.12.0)
                  (extensible to https://terminology.dhp.uz/fhir/core/ValueSet/observation-interpretation-vs|0.12.0)
                  ТипCodeableConcept
                  Модификаторfalse
                  Требуется поддержкаfalse
                  Summaryfalse
                  Требования

                  For some results, particularly numeric results, an interpretation is necessary to fully understand the significance of a result.

                  Альтернативные именаAbnormal Flag
                  Инвариантыele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
                  250. Observation.component:acrComposition.referenceRange
                  Определение

                  Guidance on how to interpret the value by comparison to a normal or recommended range.

                  КороткийProvides guide for interpretation of component result
                  Комментарии

                  Most observations only have one generic reference range. Systems MAY choose to restrict to only supplying the relevant reference range based on knowledge about the patient (e.g., specific to the patient's age, gender, weight and other factors), but this might not be possible or appropriate. Whenever more than one reference range is supplied, the differences between them SHOULD be provided in the reference range and/or age properties.

                  Контроль0..*
                  ТипСмотретьttp://hl7.org/fhir/StructureDefinition/Observation#Observation.referenceRange
                  Модификаторfalse
                  Требуется поддержкаfalse
                  Summaryfalse
                  Требования

                  Knowing what values are considered "normal" can help evaluate the significance of a particular result. Need to be able to provide multiple reference ranges for different contexts.

                  Инвариантыele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
                  252. Observation.component:skinNippleStatus
                  Название разрезаskinNippleStatus
                  Определение

                  Some observations have multiple component observations. These component observations are expressed as separate code value pairs that share the same attributes. Examples include systolic and diastolic component observations for blood pressure measurement and multiple component observations for genetics observations.

                  КороткийSkin and nipple status
                  Комментарии

                  For a discussion on the ways Observations can be assembled in groups together see Notes below.

                  Контроль0..1
                  На этот элемент влияют следующие инварианты: obs-7
                  ТипBackboneElement
                  Модификаторfalse
                  Требуется поддержкаtrue
                  Summarytrue
                  Требования

                  Component observations share the same attributes in the Observation resource as the primary observation and are always treated a part of a single observation (they are not separable). However, the reference range for the primary observation value is not inherited by the component values and is required when appropriate for each component observation.

                  Инвариантыele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
                  254. Observation.component:skinNippleStatus.id
                  Определение

                  Unique id for the element within a resource (for internal references). This may be any string value that does not contain spaces.

                  КороткийUnique id for inter-element referencing
                  Контроль0..1
                  На этот элемент влияют следующие инварианты: ele-1
                  Типstring
                  Модификаторfalse
                  Формат XMLВ формате XML это свойство представлено в качестве атрибута.
                  Summaryfalse
                  256. Observation.component:skinNippleStatus.extension
                  Определение

                  May be used to represent additional information that is not part of the basic definition of the element. To make the use of extensions safe and managable, there is a strict set of governance applied to the definition and use of extensions. Though any implementer can define an extension, there is a set of requirements that SHALL be met as part of the definition of the extension.

                  КороткийAdditional content defined by implementations
                  Комментарии

                  There can be no stigma associated with the use of extensions by any application, project, or standard - regardless of the institution or jurisdiction that uses or defines the extensions. The use of extensions is what allows the FHIR specification to retain a core level of simplicity for everyone.

                  Контроль0..*
                  ТипExtension
                  Модификаторfalse
                  Summaryfalse
                  Альтернативные именаextensions, user content
                  Инвариантыele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
                  ext-1: Must have either extensions or value[x], not both (extension.exists() != value.exists())
                  258. Observation.component:skinNippleStatus.modifierExtension
                  Определение

                  May be used to represent additional information that is not part of the basic definition of the element and that modifies the understanding of the element in which it is contained and/or the understanding of the containing element's descendants. Usually modifier elements provide negation or qualification. To make the use of extensions safe and managable, there is a strict set of governance applied to the definition and use of extensions. Though any implementer can define an extension, there is a set of requirements that SHALL be met as part of the definition of the extension. Applications processing a resource are required to check for modifier extensions.

                  Modifier extensions SHALL NOT change the meaning of any elements on Resource or DomainResource (including cannot change the meaning of modifierExtension itself).

                  КороткийExtensions that cannot be ignored even if unrecognized
                  Комментарии

                  There can be no stigma associated with the use of extensions by any application, project, or standard - regardless of the institution or jurisdiction that uses or defines the extensions. The use of extensions is what allows the FHIR specification to retain a core level of simplicity for everyone.

                  Контроль0..*
                  ТипExtension
                  Модификаторtrue потому что Modifier extensions are expected to modify the meaning or interpretation of the element that contains them
                  Summarytrue
                  Требования

                  Modifier extensions allow for extensions that cannot be safely ignored to be clearly distinguished from the vast majority of extensions which can be safely ignored. This promotes interoperability by eliminating the need for implementers to prohibit the presence of extensions. For further information, see the definition of modifier extensions.

                  Альтернативные именаextensions, user content, modifiers
                  Инвариантыele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
                  ext-1: Must have either extensions or value[x], not both (extension.exists() != value.exists())
                  260. Observation.component:skinNippleStatus.code
                  Определение

                  Describes what was observed. Sometimes this is called the observation "code".

                  КороткийType of component observation (code / type)
                  Комментарии

                  All code-value and component.code-component.value pairs need to be taken into account to correctly understand the meaning of the observation.

                  Контроль1..1
                  На этот элемент влияют следующие инварианты: obs-7
                  ПривязкаКоды СЛЕДУЕТ взять из ObservationCodesVS (0.12.0)
                  (preferred to https://terminology.dhp.uz/fhir/core/ValueSet/observation-codes-vs|0.12.0)
                  ТипCodeableConcept
                  Модификаторfalse
                  Требуется поддержкаtrue
                  Summarytrue
                  Требования

                  Knowing what kind of observation is being made is essential to understanding the observation.

                  Значение шаблона{
                    "coding" : [{
                      "system" : "https://terminology.dhp.uz/fhir/integrations/CodeSystem/screening-ultrasound-parameter-cs",
                      "code" : "scrn-0052-00006"
                    }]
                  }
                  Инвариантыele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
                  262. Observation.component:skinNippleStatus.value[x]
                  Определение

                  The information determined as a result of making the observation, if the information has a simple value.

                  КороткийActual component result
                  Комментарии

                  Used when observation has a set of component observations:

                  • An observation may have both a value (e.g. an Apgar score) and component observations (the observations from which the Apgar score was derived).
                  • If a value is present, the datatype for this element should be determined by the code.
                  • CodeableConcept with just a text would be used instead of a string if the field was usually coded, or if the type associated with the code defines a coded value.
                  • Attachment is used if the observation result value is a binary file such as an image. If the observation result value is derived from the binary file (for example 'X' detected and here is the the proof in this image), the binary file may be directly represented using DocumentReference and referenced by derivedFrom.
                  • If a value is present, the datatype for this element should be determined by the code.
                  • CodeableConcept with just a text would be used instead of a string if the field was usually coded, or if the type associated with the code defines a coded value.
                  • Attachment is used if the observation result value is a binary file such as an image. If the observation result value is derived from the binary file (for example 'X' detected and here is the the proof in this image), the binary file may be directly represented using DocumentReference and referenced by derivedFrom.
                  • The usage of valueReference is restricted to the MolecularSequence resource when used as a definitional resource, not as a patient-specific finding. .
                  • For additional guidance, see the Notes section below.
                  Контроль0..1
                  ПривязкаКоды ДОЛЖНЫ быть взяты из ScreeningUltrasoundSkinNippleStatusVS (0.12.1)
                  (required to https://terminology.dhp.uz/fhir/integrations/ValueSet/screening-ultrasound-skin-nipple-status-vs|0.12.1)
                  ТипCodeableConcept
                  [x] ЗаметкаСмотретьВыбор типов данныхдля дополнительной информации о том, как использовать [x]
                  Модификаторfalse
                  Требуется поддержкаtrue
                  Summarytrue
                  Требования

                  An observation exists to have a value, though it might not if it is in error, or if it represents a group of observations.

                  Инвариантыele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
                  264. Observation.component:skinNippleStatus.dataAbsentReason
                  Определение

                  Provides a reason why the expected value in the element Observation.component.value[x] is missing.

                  КороткийWhy the component result is missing
                  Комментарии

                  "Null" or exceptional values can be represented two ways in FHIR Observations. One way is to simply include them in the value set and represent the exceptions in the value. For example, measurement values for a serology test could be "detected", "not detected", "inconclusive", or "test not done".

                  The alternate way is to use the value element for actual observations and use the explicit dataAbsentReason element to record exceptional values. For example, the dataAbsentReason code "error" could be used when the measurement was not completed. Because of these options, use-case agreements are required to interpret general observations for exceptional values.

                  Контроль0..1
                  ПривязкаЕсли они не подходят, эти коды ДОЛЖНЫ быть взяты из DataAbsentReasonVS (0.12.0)
                  (extensible to https://terminology.dhp.uz/fhir/core/ValueSet/data-absent-reason-vs|0.12.0)
                  ТипCodeableConcept
                  Модификаторfalse
                  Требуется поддержкаfalse
                  Summaryfalse
                  Требования

                  For many results it is necessary to handle exceptional values in measurements.

                  Инвариантыele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
                  266. Observation.component:skinNippleStatus.interpretation
                  Определение

                  A categorical assessment of an observation value. For example, high, low, normal.

                  КороткийHigh, low, normal, etc
                  Комментарии

                  Historically used for laboratory results (known as 'abnormal flag' ), its use extends to other use cases where coded interpretations are relevant. Often reported as one or more simple compact codes this element is often placed adjacent to the result value in reports and flow sheets to signal the meaning/normalcy status of the result.

                  Контроль0..*
                  ПривязкаЕсли они не подходят, эти коды ДОЛЖНЫ быть взяты из ObservationInterpretationVS (0.12.0)
                  (extensible to https://terminology.dhp.uz/fhir/core/ValueSet/observation-interpretation-vs|0.12.0)
                  ТипCodeableConcept
                  Модификаторfalse
                  Требуется поддержкаfalse
                  Summaryfalse
                  Требования

                  For some results, particularly numeric results, an interpretation is necessary to fully understand the significance of a result.

                  Альтернативные именаAbnormal Flag
                  Инвариантыele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
                  268. Observation.component:skinNippleStatus.referenceRange
                  Определение

                  Guidance on how to interpret the value by comparison to a normal or recommended range.

                  КороткийProvides guide for interpretation of component result
                  Комментарии

                  Most observations only have one generic reference range. Systems MAY choose to restrict to only supplying the relevant reference range based on knowledge about the patient (e.g., specific to the patient's age, gender, weight and other factors), but this might not be possible or appropriate. Whenever more than one reference range is supplied, the differences between them SHOULD be provided in the reference range and/or age properties.

                  Контроль0..*
                  ТипСмотретьttp://hl7.org/fhir/StructureDefinition/Observation#Observation.referenceRange
                  Модификаторfalse
                  Требуется поддержкаfalse
                  Summaryfalse
                  Требования

                  Knowing what values are considered "normal" can help evaluate the significance of a particular result. Need to be able to provide multiple reference ranges for different contexts.

                  Инвариантыele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
                  270. Observation.component:tissueDifferentiation
                  Название разрезаtissueDifferentiation
                  Определение

                  Some observations have multiple component observations. These component observations are expressed as separate code value pairs that share the same attributes. Examples include systolic and diastolic component observations for blood pressure measurement and multiple component observations for genetics observations.

                  КороткийTissue differentiation
                  Комментарии

                  For a discussion on the ways Observations can be assembled in groups together see Notes below.

                  Контроль0..1
                  На этот элемент влияют следующие инварианты: obs-7
                  ТипBackboneElement
                  Модификаторfalse
                  Требуется поддержкаtrue
                  Summarytrue
                  Требования

                  Component observations share the same attributes in the Observation resource as the primary observation and are always treated a part of a single observation (they are not separable). However, the reference range for the primary observation value is not inherited by the component values and is required when appropriate for each component observation.

                  Инвариантыele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
                  272. Observation.component:tissueDifferentiation.id
                  Определение

                  Unique id for the element within a resource (for internal references). This may be any string value that does not contain spaces.

                  КороткийUnique id for inter-element referencing
                  Контроль0..1
                  На этот элемент влияют следующие инварианты: ele-1
                  Типstring
                  Модификаторfalse
                  Формат XMLВ формате XML это свойство представлено в качестве атрибута.
                  Summaryfalse
                  274. Observation.component:tissueDifferentiation.extension
                  Определение

                  May be used to represent additional information that is not part of the basic definition of the element. To make the use of extensions safe and managable, there is a strict set of governance applied to the definition and use of extensions. Though any implementer can define an extension, there is a set of requirements that SHALL be met as part of the definition of the extension.

                  КороткийAdditional content defined by implementations
                  Комментарии

                  There can be no stigma associated with the use of extensions by any application, project, or standard - regardless of the institution or jurisdiction that uses or defines the extensions. The use of extensions is what allows the FHIR specification to retain a core level of simplicity for everyone.

                  Контроль0..*
                  ТипExtension
                  Модификаторfalse
                  Summaryfalse
                  Альтернативные именаextensions, user content
                  Инвариантыele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
                  ext-1: Must have either extensions or value[x], not both (extension.exists() != value.exists())
                  276. Observation.component:tissueDifferentiation.modifierExtension
                  Определение

                  May be used to represent additional information that is not part of the basic definition of the element and that modifies the understanding of the element in which it is contained and/or the understanding of the containing element's descendants. Usually modifier elements provide negation or qualification. To make the use of extensions safe and managable, there is a strict set of governance applied to the definition and use of extensions. Though any implementer can define an extension, there is a set of requirements that SHALL be met as part of the definition of the extension. Applications processing a resource are required to check for modifier extensions.

                  Modifier extensions SHALL NOT change the meaning of any elements on Resource or DomainResource (including cannot change the meaning of modifierExtension itself).

                  КороткийExtensions that cannot be ignored even if unrecognized
                  Комментарии

                  There can be no stigma associated with the use of extensions by any application, project, or standard - regardless of the institution or jurisdiction that uses or defines the extensions. The use of extensions is what allows the FHIR specification to retain a core level of simplicity for everyone.

                  Контроль0..*
                  ТипExtension
                  Модификаторtrue потому что Modifier extensions are expected to modify the meaning or interpretation of the element that contains them
                  Summarytrue
                  Требования

                  Modifier extensions allow for extensions that cannot be safely ignored to be clearly distinguished from the vast majority of extensions which can be safely ignored. This promotes interoperability by eliminating the need for implementers to prohibit the presence of extensions. For further information, see the definition of modifier extensions.

                  Альтернативные именаextensions, user content, modifiers
                  Инвариантыele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
                  ext-1: Must have either extensions or value[x], not both (extension.exists() != value.exists())
                  278. Observation.component:tissueDifferentiation.code
                  Определение

                  Describes what was observed. Sometimes this is called the observation "code".

                  КороткийType of component observation (code / type)
                  Комментарии

                  All code-value and component.code-component.value pairs need to be taken into account to correctly understand the meaning of the observation.

                  Контроль1..1
                  На этот элемент влияют следующие инварианты: obs-7
                  ПривязкаКоды СЛЕДУЕТ взять из ObservationCodesVS (0.12.0)
                  (preferred to https://terminology.dhp.uz/fhir/core/ValueSet/observation-codes-vs|0.12.0)
                  ТипCodeableConcept
                  Модификаторfalse
                  Требуется поддержкаtrue
                  Summarytrue
                  Требования

                  Knowing what kind of observation is being made is essential to understanding the observation.

                  Значение шаблона{
                    "coding" : [{
                      "system" : "https://terminology.dhp.uz/fhir/integrations/CodeSystem/screening-ultrasound-parameter-cs",
                      "code" : "scrn-0052-00007"
                    }]
                  }
                  Инвариантыele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
                  280. Observation.component:tissueDifferentiation.value[x]
                  Определение

                  The information determined as a result of making the observation, if the information has a simple value.

                  КороткийActual component result
                  Комментарии

                  Used when observation has a set of component observations:

                  • An observation may have both a value (e.g. an Apgar score) and component observations (the observations from which the Apgar score was derived).
                  • If a value is present, the datatype for this element should be determined by the code.
                  • CodeableConcept with just a text would be used instead of a string if the field was usually coded, or if the type associated with the code defines a coded value.
                  • Attachment is used if the observation result value is a binary file such as an image. If the observation result value is derived from the binary file (for example 'X' detected and here is the the proof in this image), the binary file may be directly represented using DocumentReference and referenced by derivedFrom.
                  • If a value is present, the datatype for this element should be determined by the code.
                  • CodeableConcept with just a text would be used instead of a string if the field was usually coded, or if the type associated with the code defines a coded value.
                  • Attachment is used if the observation result value is a binary file such as an image. If the observation result value is derived from the binary file (for example 'X' detected and here is the the proof in this image), the binary file may be directly represented using DocumentReference and referenced by derivedFrom.
                  • The usage of valueReference is restricted to the MolecularSequence resource when used as a definitional resource, not as a patient-specific finding. .
                  • For additional guidance, see the Notes section below.
                  Контроль0..1
                  ПривязкаКоды ДОЛЖНЫ быть взяты из ScreeningUltrasoundTissueDifferentiationVS (0.12.1)
                  (required to https://terminology.dhp.uz/fhir/integrations/ValueSet/screening-ultrasound-tissue-differentiation-vs|0.12.1)
                  ТипCodeableConcept
                  [x] ЗаметкаСмотретьВыбор типов данныхдля дополнительной информации о том, как использовать [x]
                  Модификаторfalse
                  Требуется поддержкаtrue
                  Summarytrue
                  Требования

                  An observation exists to have a value, though it might not if it is in error, or if it represents a group of observations.

                  Инвариантыele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
                  282. Observation.component:tissueDifferentiation.dataAbsentReason
                  Определение

                  Provides a reason why the expected value in the element Observation.component.value[x] is missing.

                  КороткийWhy the component result is missing
                  Комментарии

                  "Null" or exceptional values can be represented two ways in FHIR Observations. One way is to simply include them in the value set and represent the exceptions in the value. For example, measurement values for a serology test could be "detected", "not detected", "inconclusive", or "test not done".

                  The alternate way is to use the value element for actual observations and use the explicit dataAbsentReason element to record exceptional values. For example, the dataAbsentReason code "error" could be used when the measurement was not completed. Because of these options, use-case agreements are required to interpret general observations for exceptional values.

                  Контроль0..1
                  ПривязкаЕсли они не подходят, эти коды ДОЛЖНЫ быть взяты из DataAbsentReasonVS (0.12.0)
                  (extensible to https://terminology.dhp.uz/fhir/core/ValueSet/data-absent-reason-vs|0.12.0)
                  ТипCodeableConcept
                  Модификаторfalse
                  Требуется поддержкаfalse
                  Summaryfalse
                  Требования

                  For many results it is necessary to handle exceptional values in measurements.

                  Инвариантыele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
                  284. Observation.component:tissueDifferentiation.interpretation
                  Определение

                  A categorical assessment of an observation value. For example, high, low, normal.

                  КороткийHigh, low, normal, etc
                  Комментарии

                  Historically used for laboratory results (known as 'abnormal flag' ), its use extends to other use cases where coded interpretations are relevant. Often reported as one or more simple compact codes this element is often placed adjacent to the result value in reports and flow sheets to signal the meaning/normalcy status of the result.

                  Контроль0..*
                  ПривязкаЕсли они не подходят, эти коды ДОЛЖНЫ быть взяты из ObservationInterpretationVS (0.12.0)
                  (extensible to https://terminology.dhp.uz/fhir/core/ValueSet/observation-interpretation-vs|0.12.0)
                  ТипCodeableConcept
                  Модификаторfalse
                  Требуется поддержкаfalse
                  Summaryfalse
                  Требования

                  For some results, particularly numeric results, an interpretation is necessary to fully understand the significance of a result.

                  Альтернативные именаAbnormal Flag
                  Инвариантыele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
                  286. Observation.component:tissueDifferentiation.referenceRange
                  Определение

                  Guidance on how to interpret the value by comparison to a normal or recommended range.

                  КороткийProvides guide for interpretation of component result
                  Комментарии

                  Most observations only have one generic reference range. Systems MAY choose to restrict to only supplying the relevant reference range based on knowledge about the patient (e.g., specific to the patient's age, gender, weight and other factors), but this might not be possible or appropriate. Whenever more than one reference range is supplied, the differences between them SHOULD be provided in the reference range and/or age properties.

                  Контроль0..*
                  ТипСмотретьttp://hl7.org/fhir/StructureDefinition/Observation#Observation.referenceRange
                  Модификаторfalse
                  Требуется поддержкаfalse
                  Summaryfalse
                  Требования

                  Knowing what values are considered "normal" can help evaluate the significance of a particular result. Need to be able to provide multiple reference ranges for different contexts.

                  Инвариантыele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
                  288. Observation.component:subcutaneousFat
                  Название разрезаsubcutaneousFat
                  Определение

                  Some observations have multiple component observations. These component observations are expressed as separate code value pairs that share the same attributes. Examples include systolic and diastolic component observations for blood pressure measurement and multiple component observations for genetics observations.

                  КороткийSubcutaneous fat
                  Комментарии

                  For a discussion on the ways Observations can be assembled in groups together see Notes below.

                  Контроль0..1
                  На этот элемент влияют следующие инварианты: obs-7
                  ТипBackboneElement
                  Модификаторfalse
                  Требуется поддержкаtrue
                  Summarytrue
                  Требования

                  Component observations share the same attributes in the Observation resource as the primary observation and are always treated a part of a single observation (they are not separable). However, the reference range for the primary observation value is not inherited by the component values and is required when appropriate for each component observation.

                  Инвариантыele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
                  290. Observation.component:subcutaneousFat.id
                  Определение

                  Unique id for the element within a resource (for internal references). This may be any string value that does not contain spaces.

                  КороткийUnique id for inter-element referencing
                  Контроль0..1
                  На этот элемент влияют следующие инварианты: ele-1
                  Типstring
                  Модификаторfalse
                  Формат XMLВ формате XML это свойство представлено в качестве атрибута.
                  Summaryfalse
                  292. Observation.component:subcutaneousFat.extension
                  Определение

                  May be used to represent additional information that is not part of the basic definition of the element. To make the use of extensions safe and managable, there is a strict set of governance applied to the definition and use of extensions. Though any implementer can define an extension, there is a set of requirements that SHALL be met as part of the definition of the extension.

                  КороткийAdditional content defined by implementations
                  Комментарии

                  There can be no stigma associated with the use of extensions by any application, project, or standard - regardless of the institution or jurisdiction that uses or defines the extensions. The use of extensions is what allows the FHIR specification to retain a core level of simplicity for everyone.

                  Контроль0..*
                  ТипExtension
                  Модификаторfalse
                  Summaryfalse
                  Альтернативные именаextensions, user content
                  Инвариантыele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
                  ext-1: Must have either extensions or value[x], not both (extension.exists() != value.exists())
                  294. Observation.component:subcutaneousFat.modifierExtension
                  Определение

                  May be used to represent additional information that is not part of the basic definition of the element and that modifies the understanding of the element in which it is contained and/or the understanding of the containing element's descendants. Usually modifier elements provide negation or qualification. To make the use of extensions safe and managable, there is a strict set of governance applied to the definition and use of extensions. Though any implementer can define an extension, there is a set of requirements that SHALL be met as part of the definition of the extension. Applications processing a resource are required to check for modifier extensions.

                  Modifier extensions SHALL NOT change the meaning of any elements on Resource or DomainResource (including cannot change the meaning of modifierExtension itself).

                  КороткийExtensions that cannot be ignored even if unrecognized
                  Комментарии

                  There can be no stigma associated with the use of extensions by any application, project, or standard - regardless of the institution or jurisdiction that uses or defines the extensions. The use of extensions is what allows the FHIR specification to retain a core level of simplicity for everyone.

                  Контроль0..*
                  ТипExtension
                  Модификаторtrue потому что Modifier extensions are expected to modify the meaning or interpretation of the element that contains them
                  Summarytrue
                  Требования

                  Modifier extensions allow for extensions that cannot be safely ignored to be clearly distinguished from the vast majority of extensions which can be safely ignored. This promotes interoperability by eliminating the need for implementers to prohibit the presence of extensions. For further information, see the definition of modifier extensions.

                  Альтернативные именаextensions, user content, modifiers
                  Инвариантыele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
                  ext-1: Must have either extensions or value[x], not both (extension.exists() != value.exists())
                  296. Observation.component:subcutaneousFat.code
                  Определение

                  Describes what was observed. Sometimes this is called the observation "code".

                  КороткийType of component observation (code / type)
                  Комментарии

                  All code-value and component.code-component.value pairs need to be taken into account to correctly understand the meaning of the observation.

                  Контроль1..1
                  На этот элемент влияют следующие инварианты: obs-7
                  ПривязкаКоды СЛЕДУЕТ взять из ObservationCodesVS (0.12.0)
                  (preferred to https://terminology.dhp.uz/fhir/core/ValueSet/observation-codes-vs|0.12.0)
                  ТипCodeableConcept
                  Модификаторfalse
                  Требуется поддержкаtrue
                  Summarytrue
                  Требования

                  Knowing what kind of observation is being made is essential to understanding the observation.

                  Значение шаблона{
                    "coding" : [{
                      "system" : "https://terminology.dhp.uz/fhir/integrations/CodeSystem/screening-ultrasound-parameter-cs",
                      "code" : "scrn-0052-00008"
                    }]
                  }
                  Инвариантыele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
                  298. Observation.component:subcutaneousFat.value[x]
                  Определение

                  The information determined as a result of making the observation, if the information has a simple value.

                  КороткийActual component result
                  Комментарии

                  Used when observation has a set of component observations:

                  • An observation may have both a value (e.g. an Apgar score) and component observations (the observations from which the Apgar score was derived).
                  • If a value is present, the datatype for this element should be determined by the code.
                  • CodeableConcept with just a text would be used instead of a string if the field was usually coded, or if the type associated with the code defines a coded value.
                  • Attachment is used if the observation result value is a binary file such as an image. If the observation result value is derived from the binary file (for example 'X' detected and here is the the proof in this image), the binary file may be directly represented using DocumentReference and referenced by derivedFrom.
                  • If a value is present, the datatype for this element should be determined by the code.
                  • CodeableConcept with just a text would be used instead of a string if the field was usually coded, or if the type associated with the code defines a coded value.
                  • Attachment is used if the observation result value is a binary file such as an image. If the observation result value is derived from the binary file (for example 'X' detected and here is the the proof in this image), the binary file may be directly represented using DocumentReference and referenced by derivedFrom.
                  • The usage of valueReference is restricted to the MolecularSequence resource when used as a definitional resource, not as a patient-specific finding. .
                  • For additional guidance, see the Notes section below.
                  Контроль0..1
                  ПривязкаКоды ДОЛЖНЫ быть взяты из ScreeningUltrasoundSubcutaneousFatVS (0.12.1)
                  (required to https://terminology.dhp.uz/fhir/integrations/ValueSet/screening-ultrasound-subcutaneous-fat-vs|0.12.1)
                  ТипCodeableConcept
                  [x] ЗаметкаСмотретьВыбор типов данныхдля дополнительной информации о том, как использовать [x]
                  Модификаторfalse
                  Требуется поддержкаtrue
                  Summarytrue
                  Требования

                  An observation exists to have a value, though it might not if it is in error, or if it represents a group of observations.

                  Инвариантыele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
                  300. Observation.component:subcutaneousFat.dataAbsentReason
                  Определение

                  Provides a reason why the expected value in the element Observation.component.value[x] is missing.

                  КороткийWhy the component result is missing
                  Комментарии

                  "Null" or exceptional values can be represented two ways in FHIR Observations. One way is to simply include them in the value set and represent the exceptions in the value. For example, measurement values for a serology test could be "detected", "not detected", "inconclusive", or "test not done".

                  The alternate way is to use the value element for actual observations and use the explicit dataAbsentReason element to record exceptional values. For example, the dataAbsentReason code "error" could be used when the measurement was not completed. Because of these options, use-case agreements are required to interpret general observations for exceptional values.

                  Контроль0..1
                  ПривязкаЕсли они не подходят, эти коды ДОЛЖНЫ быть взяты из DataAbsentReasonVS (0.12.0)
                  (extensible to https://terminology.dhp.uz/fhir/core/ValueSet/data-absent-reason-vs|0.12.0)
                  ТипCodeableConcept
                  Модификаторfalse
                  Требуется поддержкаfalse
                  Summaryfalse
                  Требования

                  For many results it is necessary to handle exceptional values in measurements.

                  Инвариантыele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
                  302. Observation.component:subcutaneousFat.interpretation
                  Определение

                  A categorical assessment of an observation value. For example, high, low, normal.

                  КороткийHigh, low, normal, etc
                  Комментарии

                  Historically used for laboratory results (known as 'abnormal flag' ), its use extends to other use cases where coded interpretations are relevant. Often reported as one or more simple compact codes this element is often placed adjacent to the result value in reports and flow sheets to signal the meaning/normalcy status of the result.

                  Контроль0..*
                  ПривязкаЕсли они не подходят, эти коды ДОЛЖНЫ быть взяты из ObservationInterpretationVS (0.12.0)
                  (extensible to https://terminology.dhp.uz/fhir/core/ValueSet/observation-interpretation-vs|0.12.0)
                  ТипCodeableConcept
                  Модификаторfalse
                  Требуется поддержкаfalse
                  Summaryfalse
                  Требования

                  For some results, particularly numeric results, an interpretation is necessary to fully understand the significance of a result.

                  Альтернативные именаAbnormal Flag
                  Инвариантыele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
                  304. Observation.component:subcutaneousFat.referenceRange
                  Определение

                  Guidance on how to interpret the value by comparison to a normal or recommended range.

                  КороткийProvides guide for interpretation of component result
                  Комментарии

                  Most observations only have one generic reference range. Systems MAY choose to restrict to only supplying the relevant reference range based on knowledge about the patient (e.g., specific to the patient's age, gender, weight and other factors), but this might not be possible or appropriate. Whenever more than one reference range is supplied, the differences between them SHOULD be provided in the reference range and/or age properties.

                  Контроль0..*
                  ТипСмотретьttp://hl7.org/fhir/StructureDefinition/Observation#Observation.referenceRange
                  Модификаторfalse
                  Требуется поддержкаfalse
                  Summaryfalse
                  Требования

                  Knowing what values are considered "normal" can help evaluate the significance of a particular result. Need to be able to provide multiple reference ranges for different contexts.

                  Инвариантыele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
                  306. Observation.component:fibroglandularEchogenicity
                  Название разрезаfibroglandularEchogenicity
                  Определение

                  Some observations have multiple component observations. These component observations are expressed as separate code value pairs that share the same attributes. Examples include systolic and diastolic component observations for blood pressure measurement and multiple component observations for genetics observations.

                  КороткийFibroglandular echogenicity
                  Комментарии

                  For a discussion on the ways Observations can be assembled in groups together see Notes below.

                  Контроль0..1
                  На этот элемент влияют следующие инварианты: obs-7
                  ТипBackboneElement
                  Модификаторfalse
                  Требуется поддержкаtrue
                  Summarytrue
                  Требования

                  Component observations share the same attributes in the Observation resource as the primary observation and are always treated a part of a single observation (they are not separable). However, the reference range for the primary observation value is not inherited by the component values and is required when appropriate for each component observation.

                  Инвариантыele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
                  308. Observation.component:fibroglandularEchogenicity.id
                  Определение

                  Unique id for the element within a resource (for internal references). This may be any string value that does not contain spaces.

                  КороткийUnique id for inter-element referencing
                  Контроль0..1
                  На этот элемент влияют следующие инварианты: ele-1
                  Типstring
                  Модификаторfalse
                  Формат XMLВ формате XML это свойство представлено в качестве атрибута.
                  Summaryfalse
                  310. Observation.component:fibroglandularEchogenicity.extension
                  Определение

                  May be used to represent additional information that is not part of the basic definition of the element. To make the use of extensions safe and managable, there is a strict set of governance applied to the definition and use of extensions. Though any implementer can define an extension, there is a set of requirements that SHALL be met as part of the definition of the extension.

                  КороткийAdditional content defined by implementations
                  Комментарии

                  There can be no stigma associated with the use of extensions by any application, project, or standard - regardless of the institution or jurisdiction that uses or defines the extensions. The use of extensions is what allows the FHIR specification to retain a core level of simplicity for everyone.

                  Контроль0..*
                  ТипExtension
                  Модификаторfalse
                  Summaryfalse
                  Альтернативные именаextensions, user content
                  Инвариантыele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
                  ext-1: Must have either extensions or value[x], not both (extension.exists() != value.exists())
                  312. Observation.component:fibroglandularEchogenicity.modifierExtension
                  Определение

                  May be used to represent additional information that is not part of the basic definition of the element and that modifies the understanding of the element in which it is contained and/or the understanding of the containing element's descendants. Usually modifier elements provide negation or qualification. To make the use of extensions safe and managable, there is a strict set of governance applied to the definition and use of extensions. Though any implementer can define an extension, there is a set of requirements that SHALL be met as part of the definition of the extension. Applications processing a resource are required to check for modifier extensions.

                  Modifier extensions SHALL NOT change the meaning of any elements on Resource or DomainResource (including cannot change the meaning of modifierExtension itself).

                  КороткийExtensions that cannot be ignored even if unrecognized
                  Комментарии

                  There can be no stigma associated with the use of extensions by any application, project, or standard - regardless of the institution or jurisdiction that uses or defines the extensions. The use of extensions is what allows the FHIR specification to retain a core level of simplicity for everyone.

                  Контроль0..*
                  ТипExtension
                  Модификаторtrue потому что Modifier extensions are expected to modify the meaning or interpretation of the element that contains them
                  Summarytrue
                  Требования

                  Modifier extensions allow for extensions that cannot be safely ignored to be clearly distinguished from the vast majority of extensions which can be safely ignored. This promotes interoperability by eliminating the need for implementers to prohibit the presence of extensions. For further information, see the definition of modifier extensions.

                  Альтернативные именаextensions, user content, modifiers
                  Инвариантыele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
                  ext-1: Must have either extensions or value[x], not both (extension.exists() != value.exists())
                  314. Observation.component:fibroglandularEchogenicity.code
                  Определение

                  Describes what was observed. Sometimes this is called the observation "code".

                  КороткийType of component observation (code / type)
                  Комментарии

                  All code-value and component.code-component.value pairs need to be taken into account to correctly understand the meaning of the observation.

                  Контроль1..1
                  На этот элемент влияют следующие инварианты: obs-7
                  ПривязкаКоды СЛЕДУЕТ взять из ObservationCodesVS (0.12.0)
                  (preferred to https://terminology.dhp.uz/fhir/core/ValueSet/observation-codes-vs|0.12.0)
                  ТипCodeableConcept
                  Модификаторfalse
                  Требуется поддержкаtrue
                  Summarytrue
                  Требования

                  Knowing what kind of observation is being made is essential to understanding the observation.

                  Значение шаблона{
                    "coding" : [{
                      "system" : "https://terminology.dhp.uz/fhir/integrations/CodeSystem/screening-ultrasound-parameter-cs",
                      "code" : "scrn-0052-00010"
                    }]
                  }
                  Инвариантыele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
                  316. Observation.component:fibroglandularEchogenicity.value[x]
                  Определение

                  The information determined as a result of making the observation, if the information has a simple value.

                  КороткийActual component result
                  Комментарии

                  Used when observation has a set of component observations:

                  • An observation may have both a value (e.g. an Apgar score) and component observations (the observations from which the Apgar score was derived).
                  • If a value is present, the datatype for this element should be determined by the code.
                  • CodeableConcept with just a text would be used instead of a string if the field was usually coded, or if the type associated with the code defines a coded value.
                  • Attachment is used if the observation result value is a binary file such as an image. If the observation result value is derived from the binary file (for example 'X' detected and here is the the proof in this image), the binary file may be directly represented using DocumentReference and referenced by derivedFrom.
                  • If a value is present, the datatype for this element should be determined by the code.
                  • CodeableConcept with just a text would be used instead of a string if the field was usually coded, or if the type associated with the code defines a coded value.
                  • Attachment is used if the observation result value is a binary file such as an image. If the observation result value is derived from the binary file (for example 'X' detected and here is the the proof in this image), the binary file may be directly represented using DocumentReference and referenced by derivedFrom.
                  • The usage of valueReference is restricted to the MolecularSequence resource when used as a definitional resource, not as a patient-specific finding. .
                  • For additional guidance, see the Notes section below.
                  Контроль0..1
                  ПривязкаКоды ДОЛЖНЫ быть взяты из ScreeningUltrasoundFibroglandularEchogenicityVS (0.12.1)
                  (required to https://terminology.dhp.uz/fhir/integrations/ValueSet/screening-ultrasound-fibroglandular-echogenicity-vs|0.12.1)
                  ТипCodeableConcept
                  [x] ЗаметкаСмотретьВыбор типов данныхдля дополнительной информации о том, как использовать [x]
                  Модификаторfalse
                  Требуется поддержкаtrue
                  Summarytrue
                  Требования

                  An observation exists to have a value, though it might not if it is in error, or if it represents a group of observations.

                  Инвариантыele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
                  318. Observation.component:fibroglandularEchogenicity.dataAbsentReason
                  Определение

                  Provides a reason why the expected value in the element Observation.component.value[x] is missing.

                  КороткийWhy the component result is missing
                  Комментарии

                  "Null" or exceptional values can be represented two ways in FHIR Observations. One way is to simply include them in the value set and represent the exceptions in the value. For example, measurement values for a serology test could be "detected", "not detected", "inconclusive", or "test not done".

                  The alternate way is to use the value element for actual observations and use the explicit dataAbsentReason element to record exceptional values. For example, the dataAbsentReason code "error" could be used when the measurement was not completed. Because of these options, use-case agreements are required to interpret general observations for exceptional values.

                  Контроль0..1
                  ПривязкаЕсли они не подходят, эти коды ДОЛЖНЫ быть взяты из DataAbsentReasonVS (0.12.0)
                  (extensible to https://terminology.dhp.uz/fhir/core/ValueSet/data-absent-reason-vs|0.12.0)
                  ТипCodeableConcept
                  Модификаторfalse
                  Требуется поддержкаfalse
                  Summaryfalse
                  Требования

                  For many results it is necessary to handle exceptional values in measurements.

                  Инвариантыele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
                  320. Observation.component:fibroglandularEchogenicity.interpretation
                  Определение

                  A categorical assessment of an observation value. For example, high, low, normal.

                  КороткийHigh, low, normal, etc
                  Комментарии

                  Historically used for laboratory results (known as 'abnormal flag' ), its use extends to other use cases where coded interpretations are relevant. Often reported as one or more simple compact codes this element is often placed adjacent to the result value in reports and flow sheets to signal the meaning/normalcy status of the result.

                  Контроль0..*
                  ПривязкаЕсли они не подходят, эти коды ДОЛЖНЫ быть взяты из ObservationInterpretationVS (0.12.0)
                  (extensible to https://terminology.dhp.uz/fhir/core/ValueSet/observation-interpretation-vs|0.12.0)
                  ТипCodeableConcept
                  Модификаторfalse
                  Требуется поддержкаfalse
                  Summaryfalse
                  Требования

                  For some results, particularly numeric results, an interpretation is necessary to fully understand the significance of a result.

                  Альтернативные именаAbnormal Flag
                  Инвариантыele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
                  322. Observation.component:fibroglandularEchogenicity.referenceRange
                  Определение

                  Guidance on how to interpret the value by comparison to a normal or recommended range.

                  КороткийProvides guide for interpretation of component result
                  Комментарии

                  Most observations only have one generic reference range. Systems MAY choose to restrict to only supplying the relevant reference range based on knowledge about the patient (e.g., specific to the patient's age, gender, weight and other factors), but this might not be possible or appropriate. Whenever more than one reference range is supplied, the differences between them SHOULD be provided in the reference range and/or age properties.

                  Контроль0..*
                  ТипСмотретьttp://hl7.org/fhir/StructureDefinition/Observation#Observation.referenceRange
                  Модификаторfalse
                  Требуется поддержкаfalse
                  Summaryfalse
                  Требования

                  Knowing what values are considered "normal" can help evaluate the significance of a particular result. Need to be able to provide multiple reference ranges for different contexts.

                  Инвариантыele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
                  324. Observation.component:ductStatus
                  Название разрезаductStatus
                  Определение

                  Some observations have multiple component observations. These component observations are expressed as separate code value pairs that share the same attributes. Examples include systolic and diastolic component observations for blood pressure measurement and multiple component observations for genetics observations.

                  КороткийDuct status
                  Комментарии

                  For a discussion on the ways Observations can be assembled in groups together see Notes below.

                  Контроль0..1
                  На этот элемент влияют следующие инварианты: obs-7
                  ТипBackboneElement
                  Модификаторfalse
                  Требуется поддержкаtrue
                  Summarytrue
                  Требования

                  Component observations share the same attributes in the Observation resource as the primary observation and are always treated a part of a single observation (they are not separable). However, the reference range for the primary observation value is not inherited by the component values and is required when appropriate for each component observation.

                  Инвариантыele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
                  326. Observation.component:ductStatus.id
                  Определение

                  Unique id for the element within a resource (for internal references). This may be any string value that does not contain spaces.

                  КороткийUnique id for inter-element referencing
                  Контроль0..1
                  На этот элемент влияют следующие инварианты: ele-1
                  Типstring
                  Модификаторfalse
                  Формат XMLВ формате XML это свойство представлено в качестве атрибута.
                  Summaryfalse
                  328. Observation.component:ductStatus.extension
                  Определение

                  May be used to represent additional information that is not part of the basic definition of the element. To make the use of extensions safe and managable, there is a strict set of governance applied to the definition and use of extensions. Though any implementer can define an extension, there is a set of requirements that SHALL be met as part of the definition of the extension.

                  КороткийAdditional content defined by implementations
                  Комментарии

                  There can be no stigma associated with the use of extensions by any application, project, or standard - regardless of the institution or jurisdiction that uses or defines the extensions. The use of extensions is what allows the FHIR specification to retain a core level of simplicity for everyone.

                  Контроль0..*
                  ТипExtension
                  Модификаторfalse
                  Summaryfalse
                  Альтернативные именаextensions, user content
                  Инвариантыele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
                  ext-1: Must have either extensions or value[x], not both (extension.exists() != value.exists())
                  330. Observation.component:ductStatus.modifierExtension
                  Определение

                  May be used to represent additional information that is not part of the basic definition of the element and that modifies the understanding of the element in which it is contained and/or the understanding of the containing element's descendants. Usually modifier elements provide negation or qualification. To make the use of extensions safe and managable, there is a strict set of governance applied to the definition and use of extensions. Though any implementer can define an extension, there is a set of requirements that SHALL be met as part of the definition of the extension. Applications processing a resource are required to check for modifier extensions.

                  Modifier extensions SHALL NOT change the meaning of any elements on Resource or DomainResource (including cannot change the meaning of modifierExtension itself).

                  КороткийExtensions that cannot be ignored even if unrecognized
                  Комментарии

                  There can be no stigma associated with the use of extensions by any application, project, or standard - regardless of the institution or jurisdiction that uses or defines the extensions. The use of extensions is what allows the FHIR specification to retain a core level of simplicity for everyone.

                  Контроль0..*
                  ТипExtension
                  Модификаторtrue потому что Modifier extensions are expected to modify the meaning or interpretation of the element that contains them
                  Summarytrue
                  Требования

                  Modifier extensions allow for extensions that cannot be safely ignored to be clearly distinguished from the vast majority of extensions which can be safely ignored. This promotes interoperability by eliminating the need for implementers to prohibit the presence of extensions. For further information, see the definition of modifier extensions.

                  Альтернативные именаextensions, user content, modifiers
                  Инвариантыele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
                  ext-1: Must have either extensions or value[x], not both (extension.exists() != value.exists())
                  332. Observation.component:ductStatus.code
                  Определение

                  Describes what was observed. Sometimes this is called the observation "code".

                  КороткийType of component observation (code / type)
                  Комментарии

                  All code-value and component.code-component.value pairs need to be taken into account to correctly understand the meaning of the observation.

                  Контроль1..1
                  На этот элемент влияют следующие инварианты: obs-7
                  ПривязкаКоды СЛЕДУЕТ взять из ObservationCodesVS (0.12.0)
                  (preferred to https://terminology.dhp.uz/fhir/core/ValueSet/observation-codes-vs|0.12.0)
                  ТипCodeableConcept
                  Модификаторfalse
                  Требуется поддержкаtrue
                  Summarytrue
                  Требования

                  Knowing what kind of observation is being made is essential to understanding the observation.

                  Значение шаблона{
                    "coding" : [{
                      "system" : "https://terminology.dhp.uz/fhir/integrations/CodeSystem/screening-ultrasound-parameter-cs",
                      "code" : "scrn-0052-00012"
                    }]
                  }
                  Инвариантыele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
                  334. Observation.component:ductStatus.value[x]
                  Определение

                  The information determined as a result of making the observation, if the information has a simple value.

                  КороткийActual component result
                  Комментарии

                  Used when observation has a set of component observations:

                  • An observation may have both a value (e.g. an Apgar score) and component observations (the observations from which the Apgar score was derived).
                  • If a value is present, the datatype for this element should be determined by the code.
                  • CodeableConcept with just a text would be used instead of a string if the field was usually coded, or if the type associated with the code defines a coded value.
                  • Attachment is used if the observation result value is a binary file such as an image. If the observation result value is derived from the binary file (for example 'X' detected and here is the the proof in this image), the binary file may be directly represented using DocumentReference and referenced by derivedFrom.
                  • If a value is present, the datatype for this element should be determined by the code.
                  • CodeableConcept with just a text would be used instead of a string if the field was usually coded, or if the type associated with the code defines a coded value.
                  • Attachment is used if the observation result value is a binary file such as an image. If the observation result value is derived from the binary file (for example 'X' detected and here is the the proof in this image), the binary file may be directly represented using DocumentReference and referenced by derivedFrom.
                  • The usage of valueReference is restricted to the MolecularSequence resource when used as a definitional resource, not as a patient-specific finding. .
                  • For additional guidance, see the Notes section below.
                  Контроль0..1
                  ПривязкаКоды ДОЛЖНЫ быть взяты из ScreeningUltrasoundDuctStatusVS (0.12.1)
                  (required to https://terminology.dhp.uz/fhir/integrations/ValueSet/screening-ultrasound-duct-status-vs|0.12.1)
                  ТипCodeableConcept
                  [x] ЗаметкаСмотретьВыбор типов данныхдля дополнительной информации о том, как использовать [x]
                  Модификаторfalse
                  Требуется поддержкаtrue
                  Summarytrue
                  Требования

                  An observation exists to have a value, though it might not if it is in error, or if it represents a group of observations.

                  Инвариантыele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
                  336. Observation.component:ductStatus.dataAbsentReason
                  Определение

                  Provides a reason why the expected value in the element Observation.component.value[x] is missing.

                  КороткийWhy the component result is missing
                  Комментарии

                  "Null" or exceptional values can be represented two ways in FHIR Observations. One way is to simply include them in the value set and represent the exceptions in the value. For example, measurement values for a serology test could be "detected", "not detected", "inconclusive", or "test not done".

                  The alternate way is to use the value element for actual observations and use the explicit dataAbsentReason element to record exceptional values. For example, the dataAbsentReason code "error" could be used when the measurement was not completed. Because of these options, use-case agreements are required to interpret general observations for exceptional values.

                  Контроль0..1
                  ПривязкаЕсли они не подходят, эти коды ДОЛЖНЫ быть взяты из DataAbsentReasonVS (0.12.0)
                  (extensible to https://terminology.dhp.uz/fhir/core/ValueSet/data-absent-reason-vs|0.12.0)
                  ТипCodeableConcept
                  Модификаторfalse
                  Требуется поддержкаfalse
                  Summaryfalse
                  Требования

                  For many results it is necessary to handle exceptional values in measurements.

                  Инвариантыele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
                  338. Observation.component:ductStatus.interpretation
                  Определение

                  A categorical assessment of an observation value. For example, high, low, normal.

                  КороткийHigh, low, normal, etc
                  Комментарии

                  Historically used for laboratory results (known as 'abnormal flag' ), its use extends to other use cases where coded interpretations are relevant. Often reported as one or more simple compact codes this element is often placed adjacent to the result value in reports and flow sheets to signal the meaning/normalcy status of the result.

                  Контроль0..*
                  ПривязкаЕсли они не подходят, эти коды ДОЛЖНЫ быть взяты из ObservationInterpretationVS (0.12.0)
                  (extensible to https://terminology.dhp.uz/fhir/core/ValueSet/observation-interpretation-vs|0.12.0)
                  ТипCodeableConcept
                  Модификаторfalse
                  Требуется поддержкаfalse
                  Summaryfalse
                  Требования

                  For some results, particularly numeric results, an interpretation is necessary to fully understand the significance of a result.

                  Альтернативные именаAbnormal Flag
                  Инвариантыele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
                  340. Observation.component:ductStatus.referenceRange
                  Определение

                  Guidance on how to interpret the value by comparison to a normal or recommended range.

                  КороткийProvides guide for interpretation of component result
                  Комментарии

                  Most observations only have one generic reference range. Systems MAY choose to restrict to only supplying the relevant reference range based on knowledge about the patient (e.g., specific to the patient's age, gender, weight and other factors), but this might not be possible or appropriate. Whenever more than one reference range is supplied, the differences between them SHOULD be provided in the reference range and/or age properties.

                  Контроль0..*
                  ТипСмотретьttp://hl7.org/fhir/StructureDefinition/Observation#Observation.referenceRange
                  Модификаторfalse
                  Требуется поддержкаfalse
                  Summaryfalse
                  Требования

                  Knowing what values are considered "normal" can help evaluate the significance of a particular result. Need to be able to provide multiple reference ranges for different contexts.

                  Инвариантыele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
                  342. Observation.component:retromammarySpace
                  Название разрезаretromammarySpace
                  Определение

                  Some observations have multiple component observations. These component observations are expressed as separate code value pairs that share the same attributes. Examples include systolic and diastolic component observations for blood pressure measurement and multiple component observations for genetics observations.

                  КороткийRetromammary space
                  Комментарии

                  For a discussion on the ways Observations can be assembled in groups together see Notes below.

                  Контроль0..1
                  На этот элемент влияют следующие инварианты: obs-7
                  ТипBackboneElement
                  Модификаторfalse
                  Требуется поддержкаtrue
                  Summarytrue
                  Требования

                  Component observations share the same attributes in the Observation resource as the primary observation and are always treated a part of a single observation (they are not separable). However, the reference range for the primary observation value is not inherited by the component values and is required when appropriate for each component observation.

                  Инвариантыele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
                  344. Observation.component:retromammarySpace.id
                  Определение

                  Unique id for the element within a resource (for internal references). This may be any string value that does not contain spaces.

                  КороткийUnique id for inter-element referencing
                  Контроль0..1
                  На этот элемент влияют следующие инварианты: ele-1
                  Типstring
                  Модификаторfalse
                  Формат XMLВ формате XML это свойство представлено в качестве атрибута.
                  Summaryfalse
                  346. Observation.component:retromammarySpace.extension
                  Определение

                  May be used to represent additional information that is not part of the basic definition of the element. To make the use of extensions safe and managable, there is a strict set of governance applied to the definition and use of extensions. Though any implementer can define an extension, there is a set of requirements that SHALL be met as part of the definition of the extension.

                  КороткийAdditional content defined by implementations
                  Комментарии

                  There can be no stigma associated with the use of extensions by any application, project, or standard - regardless of the institution or jurisdiction that uses or defines the extensions. The use of extensions is what allows the FHIR specification to retain a core level of simplicity for everyone.

                  Контроль0..*
                  ТипExtension
                  Модификаторfalse
                  Summaryfalse
                  Альтернативные именаextensions, user content
                  Инвариантыele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
                  ext-1: Must have either extensions or value[x], not both (extension.exists() != value.exists())
                  348. Observation.component:retromammarySpace.modifierExtension
                  Определение

                  May be used to represent additional information that is not part of the basic definition of the element and that modifies the understanding of the element in which it is contained and/or the understanding of the containing element's descendants. Usually modifier elements provide negation or qualification. To make the use of extensions safe and managable, there is a strict set of governance applied to the definition and use of extensions. Though any implementer can define an extension, there is a set of requirements that SHALL be met as part of the definition of the extension. Applications processing a resource are required to check for modifier extensions.

                  Modifier extensions SHALL NOT change the meaning of any elements on Resource or DomainResource (including cannot change the meaning of modifierExtension itself).

                  КороткийExtensions that cannot be ignored even if unrecognized
                  Комментарии

                  There can be no stigma associated with the use of extensions by any application, project, or standard - regardless of the institution or jurisdiction that uses or defines the extensions. The use of extensions is what allows the FHIR specification to retain a core level of simplicity for everyone.

                  Контроль0..*
                  ТипExtension
                  Модификаторtrue потому что Modifier extensions are expected to modify the meaning or interpretation of the element that contains them
                  Summarytrue
                  Требования

                  Modifier extensions allow for extensions that cannot be safely ignored to be clearly distinguished from the vast majority of extensions which can be safely ignored. This promotes interoperability by eliminating the need for implementers to prohibit the presence of extensions. For further information, see the definition of modifier extensions.

                  Альтернативные именаextensions, user content, modifiers
                  Инвариантыele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
                  ext-1: Must have either extensions or value[x], not both (extension.exists() != value.exists())
                  350. Observation.component:retromammarySpace.code
                  Определение

                  Describes what was observed. Sometimes this is called the observation "code".

                  КороткийType of component observation (code / type)
                  Комментарии

                  All code-value and component.code-component.value pairs need to be taken into account to correctly understand the meaning of the observation.

                  Контроль1..1
                  На этот элемент влияют следующие инварианты: obs-7
                  ПривязкаКоды СЛЕДУЕТ взять из ObservationCodesVS (0.12.0)
                  (preferred to https://terminology.dhp.uz/fhir/core/ValueSet/observation-codes-vs|0.12.0)
                  ТипCodeableConcept
                  Модификаторfalse
                  Требуется поддержкаtrue
                  Summarytrue
                  Требования

                  Knowing what kind of observation is being made is essential to understanding the observation.

                  Значение шаблона{
                    "coding" : [{
                      "system" : "https://terminology.dhp.uz/fhir/integrations/CodeSystem/screening-ultrasound-parameter-cs",
                      "code" : "scrn-0052-00013"
                    }]
                  }
                  Инвариантыele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
                  352. Observation.component:retromammarySpace.value[x]
                  Определение

                  The information determined as a result of making the observation, if the information has a simple value.

                  КороткийActual component result
                  Комментарии

                  Used when observation has a set of component observations:

                  • An observation may have both a value (e.g. an Apgar score) and component observations (the observations from which the Apgar score was derived).
                  • If a value is present, the datatype for this element should be determined by the code.
                  • CodeableConcept with just a text would be used instead of a string if the field was usually coded, or if the type associated with the code defines a coded value.
                  • Attachment is used if the observation result value is a binary file such as an image. If the observation result value is derived from the binary file (for example 'X' detected and here is the the proof in this image), the binary file may be directly represented using DocumentReference and referenced by derivedFrom.
                  • If a value is present, the datatype for this element should be determined by the code.
                  • CodeableConcept with just a text would be used instead of a string if the field was usually coded, or if the type associated with the code defines a coded value.
                  • Attachment is used if the observation result value is a binary file such as an image. If the observation result value is derived from the binary file (for example 'X' detected and here is the the proof in this image), the binary file may be directly represented using DocumentReference and referenced by derivedFrom.
                  • The usage of valueReference is restricted to the MolecularSequence resource when used as a definitional resource, not as a patient-specific finding. .
                  • For additional guidance, see the Notes section below.
                  Контроль0..1
                  ПривязкаКоды ДОЛЖНЫ быть взяты из ScreeningUltrasoundRetromammarySpaceVS (0.12.1)
                  (required to https://terminology.dhp.uz/fhir/integrations/ValueSet/screening-ultrasound-retromammary-space-vs|0.12.1)
                  ТипCodeableConcept
                  [x] ЗаметкаСмотретьВыбор типов данныхдля дополнительной информации о том, как использовать [x]
                  Модификаторfalse
                  Требуется поддержкаtrue
                  Summarytrue
                  Требования

                  An observation exists to have a value, though it might not if it is in error, or if it represents a group of observations.

                  Инвариантыele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
                  354. Observation.component:retromammarySpace.dataAbsentReason
                  Определение

                  Provides a reason why the expected value in the element Observation.component.value[x] is missing.

                  КороткийWhy the component result is missing
                  Комментарии

                  "Null" or exceptional values can be represented two ways in FHIR Observations. One way is to simply include them in the value set and represent the exceptions in the value. For example, measurement values for a serology test could be "detected", "not detected", "inconclusive", or "test not done".

                  The alternate way is to use the value element for actual observations and use the explicit dataAbsentReason element to record exceptional values. For example, the dataAbsentReason code "error" could be used when the measurement was not completed. Because of these options, use-case agreements are required to interpret general observations for exceptional values.

                  Контроль0..1
                  ПривязкаЕсли они не подходят, эти коды ДОЛЖНЫ быть взяты из DataAbsentReasonVS (0.12.0)
                  (extensible to https://terminology.dhp.uz/fhir/core/ValueSet/data-absent-reason-vs|0.12.0)
                  ТипCodeableConcept
                  Модификаторfalse
                  Требуется поддержкаfalse
                  Summaryfalse
                  Требования

                  For many results it is necessary to handle exceptional values in measurements.

                  Инвариантыele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
                  356. Observation.component:retromammarySpace.interpretation
                  Определение

                  A categorical assessment of an observation value. For example, high, low, normal.

                  КороткийHigh, low, normal, etc
                  Комментарии

                  Historically used for laboratory results (known as 'abnormal flag' ), its use extends to other use cases where coded interpretations are relevant. Often reported as one or more simple compact codes this element is often placed adjacent to the result value in reports and flow sheets to signal the meaning/normalcy status of the result.

                  Контроль0..*
                  ПривязкаЕсли они не подходят, эти коды ДОЛЖНЫ быть взяты из ObservationInterpretationVS (0.12.0)
                  (extensible to https://terminology.dhp.uz/fhir/core/ValueSet/observation-interpretation-vs|0.12.0)
                  ТипCodeableConcept
                  Модификаторfalse
                  Требуется поддержкаfalse
                  Summaryfalse
                  Требования

                  For some results, particularly numeric results, an interpretation is necessary to fully understand the significance of a result.

                  Альтернативные именаAbnormal Flag
                  Инвариантыele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
                  358. Observation.component:retromammarySpace.referenceRange
                  Определение

                  Guidance on how to interpret the value by comparison to a normal or recommended range.

                  КороткийProvides guide for interpretation of component result
                  Комментарии

                  Most observations only have one generic reference range. Systems MAY choose to restrict to only supplying the relevant reference range based on knowledge about the patient (e.g., specific to the patient's age, gender, weight and other factors), but this might not be possible or appropriate. Whenever more than one reference range is supplied, the differences between them SHOULD be provided in the reference range and/or age properties.

                  Контроль0..*
                  ТипСмотретьttp://hl7.org/fhir/StructureDefinition/Observation#Observation.referenceRange
                  Модификаторfalse
                  Требуется поддержкаfalse
                  Summaryfalse
                  Требования

                  Knowing what values are considered "normal" can help evaluate the significance of a particular result. Need to be able to provide multiple reference ranges for different contexts.

                  Инвариантыele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
                  360. Observation.component:elastographyColorType
                  Название разрезаelastographyColorType
                  Определение

                  Some observations have multiple component observations. These component observations are expressed as separate code value pairs that share the same attributes. Examples include systolic and diastolic component observations for blood pressure measurement and multiple component observations for genetics observations.

                  КороткийElastography color type
                  Комментарии

                  For a discussion on the ways Observations can be assembled in groups together see Notes below.

                  Контроль0..1
                  На этот элемент влияют следующие инварианты: obs-7
                  ТипBackboneElement
                  Модификаторfalse
                  Требуется поддержкаtrue
                  Summarytrue
                  Требования

                  Component observations share the same attributes in the Observation resource as the primary observation and are always treated a part of a single observation (they are not separable). However, the reference range for the primary observation value is not inherited by the component values and is required when appropriate for each component observation.

                  Инвариантыele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
                  362. Observation.component:elastographyColorType.id
                  Определение

                  Unique id for the element within a resource (for internal references). This may be any string value that does not contain spaces.

                  КороткийUnique id for inter-element referencing
                  Контроль0..1
                  На этот элемент влияют следующие инварианты: ele-1
                  Типstring
                  Модификаторfalse
                  Формат XMLВ формате XML это свойство представлено в качестве атрибута.
                  Summaryfalse
                  364. Observation.component:elastographyColorType.extension
                  Определение

                  May be used to represent additional information that is not part of the basic definition of the element. To make the use of extensions safe and managable, there is a strict set of governance applied to the definition and use of extensions. Though any implementer can define an extension, there is a set of requirements that SHALL be met as part of the definition of the extension.

                  КороткийAdditional content defined by implementations
                  Комментарии

                  There can be no stigma associated with the use of extensions by any application, project, or standard - regardless of the institution or jurisdiction that uses or defines the extensions. The use of extensions is what allows the FHIR specification to retain a core level of simplicity for everyone.

                  Контроль0..*
                  ТипExtension
                  Модификаторfalse
                  Summaryfalse
                  Альтернативные именаextensions, user content
                  Инвариантыele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
                  ext-1: Must have either extensions or value[x], not both (extension.exists() != value.exists())
                  366. Observation.component:elastographyColorType.modifierExtension
                  Определение

                  May be used to represent additional information that is not part of the basic definition of the element and that modifies the understanding of the element in which it is contained and/or the understanding of the containing element's descendants. Usually modifier elements provide negation or qualification. To make the use of extensions safe and managable, there is a strict set of governance applied to the definition and use of extensions. Though any implementer can define an extension, there is a set of requirements that SHALL be met as part of the definition of the extension. Applications processing a resource are required to check for modifier extensions.

                  Modifier extensions SHALL NOT change the meaning of any elements on Resource or DomainResource (including cannot change the meaning of modifierExtension itself).

                  КороткийExtensions that cannot be ignored even if unrecognized
                  Комментарии

                  There can be no stigma associated with the use of extensions by any application, project, or standard - regardless of the institution or jurisdiction that uses or defines the extensions. The use of extensions is what allows the FHIR specification to retain a core level of simplicity for everyone.

                  Контроль0..*
                  ТипExtension
                  Модификаторtrue потому что Modifier extensions are expected to modify the meaning or interpretation of the element that contains them
                  Summarytrue
                  Требования

                  Modifier extensions allow for extensions that cannot be safely ignored to be clearly distinguished from the vast majority of extensions which can be safely ignored. This promotes interoperability by eliminating the need for implementers to prohibit the presence of extensions. For further information, see the definition of modifier extensions.

                  Альтернативные именаextensions, user content, modifiers
                  Инвариантыele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
                  ext-1: Must have either extensions or value[x], not both (extension.exists() != value.exists())
                  368. Observation.component:elastographyColorType.code
                  Определение

                  Describes what was observed. Sometimes this is called the observation "code".

                  КороткийType of component observation (code / type)
                  Комментарии

                  All code-value and component.code-component.value pairs need to be taken into account to correctly understand the meaning of the observation.

                  Контроль1..1
                  На этот элемент влияют следующие инварианты: obs-7
                  ПривязкаКоды СЛЕДУЕТ взять из ObservationCodesVS (0.12.0)
                  (preferred to https://terminology.dhp.uz/fhir/core/ValueSet/observation-codes-vs|0.12.0)
                  ТипCodeableConcept
                  Модификаторfalse
                  Требуется поддержкаtrue
                  Summarytrue
                  Требования

                  Knowing what kind of observation is being made is essential to understanding the observation.

                  Значение шаблона{
                    "coding" : [{
                      "system" : "https://terminology.dhp.uz/fhir/integrations/CodeSystem/screening-ultrasound-parameter-cs",
                      "code" : "scrn-0052-00015"
                    }]
                  }
                  Инвариантыele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
                  370. Observation.component:elastographyColorType.value[x]
                  Определение

                  The information determined as a result of making the observation, if the information has a simple value.

                  КороткийActual component result
                  Комментарии

                  Used when observation has a set of component observations:

                  • An observation may have both a value (e.g. an Apgar score) and component observations (the observations from which the Apgar score was derived).
                  • If a value is present, the datatype for this element should be determined by the code.
                  • CodeableConcept with just a text would be used instead of a string if the field was usually coded, or if the type associated with the code defines a coded value.
                  • Attachment is used if the observation result value is a binary file such as an image. If the observation result value is derived from the binary file (for example 'X' detected and here is the the proof in this image), the binary file may be directly represented using DocumentReference and referenced by derivedFrom.
                  • If a value is present, the datatype for this element should be determined by the code.
                  • CodeableConcept with just a text would be used instead of a string if the field was usually coded, or if the type associated with the code defines a coded value.
                  • Attachment is used if the observation result value is a binary file such as an image. If the observation result value is derived from the binary file (for example 'X' detected and here is the the proof in this image), the binary file may be directly represented using DocumentReference and referenced by derivedFrom.
                  • The usage of valueReference is restricted to the MolecularSequence resource when used as a definitional resource, not as a patient-specific finding. .
                  • For additional guidance, see the Notes section below.
                  Контроль0..1
                  ПривязкаКоды ДОЛЖНЫ быть взяты из ScreeningUltrasoundElastographyColorTypeVS (0.12.1)
                  (required to https://terminology.dhp.uz/fhir/integrations/ValueSet/screening-ultrasound-elastography-color-type-vs|0.12.1)
                  ТипCodeableConcept
                  [x] ЗаметкаСмотретьВыбор типов данныхдля дополнительной информации о том, как использовать [x]
                  Модификаторfalse
                  Требуется поддержкаtrue
                  Summarytrue
                  Требования

                  An observation exists to have a value, though it might not if it is in error, or if it represents a group of observations.

                  Инвариантыele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
                  372. Observation.component:elastographyColorType.dataAbsentReason
                  Определение

                  Provides a reason why the expected value in the element Observation.component.value[x] is missing.

                  КороткийWhy the component result is missing
                  Комментарии

                  "Null" or exceptional values can be represented two ways in FHIR Observations. One way is to simply include them in the value set and represent the exceptions in the value. For example, measurement values for a serology test could be "detected", "not detected", "inconclusive", or "test not done".

                  The alternate way is to use the value element for actual observations and use the explicit dataAbsentReason element to record exceptional values. For example, the dataAbsentReason code "error" could be used when the measurement was not completed. Because of these options, use-case agreements are required to interpret general observations for exceptional values.

                  Контроль0..1
                  ПривязкаЕсли они не подходят, эти коды ДОЛЖНЫ быть взяты из DataAbsentReasonVS (0.12.0)
                  (extensible to https://terminology.dhp.uz/fhir/core/ValueSet/data-absent-reason-vs|0.12.0)
                  ТипCodeableConcept
                  Модификаторfalse
                  Требуется поддержкаfalse
                  Summaryfalse
                  Требования

                  For many results it is necessary to handle exceptional values in measurements.

                  Инвариантыele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
                  374. Observation.component:elastographyColorType.interpretation
                  Определение

                  A categorical assessment of an observation value. For example, high, low, normal.

                  КороткийHigh, low, normal, etc
                  Комментарии

                  Historically used for laboratory results (known as 'abnormal flag' ), its use extends to other use cases where coded interpretations are relevant. Often reported as one or more simple compact codes this element is often placed adjacent to the result value in reports and flow sheets to signal the meaning/normalcy status of the result.

                  Контроль0..*
                  ПривязкаЕсли они не подходят, эти коды ДОЛЖНЫ быть взяты из ObservationInterpretationVS (0.12.0)
                  (extensible to https://terminology.dhp.uz/fhir/core/ValueSet/observation-interpretation-vs|0.12.0)
                  ТипCodeableConcept
                  Модификаторfalse
                  Требуется поддержкаfalse
                  Summaryfalse
                  Требования

                  For some results, particularly numeric results, an interpretation is necessary to fully understand the significance of a result.

                  Альтернативные именаAbnormal Flag
                  Инвариантыele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
                  376. Observation.component:elastographyColorType.referenceRange
                  Определение

                  Guidance on how to interpret the value by comparison to a normal or recommended range.

                  КороткийProvides guide for interpretation of component result
                  Комментарии

                  Most observations only have one generic reference range. Systems MAY choose to restrict to only supplying the relevant reference range based on knowledge about the patient (e.g., specific to the patient's age, gender, weight and other factors), but this might not be possible or appropriate. Whenever more than one reference range is supplied, the differences between them SHOULD be provided in the reference range and/or age properties.

                  Контроль0..*
                  ТипСмотретьttp://hl7.org/fhir/StructureDefinition/Observation#Observation.referenceRange
                  Модификаторfalse
                  Требуется поддержкаfalse
                  Summaryfalse
                  Требования

                  Knowing what values are considered "normal" can help evaluate the significance of a particular result. Need to be able to provide multiple reference ranges for different contexts.

                  Инвариантыele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
                  378. Observation.component:intramammaryNodeStatus
                  Название разрезаintramammaryNodeStatus
                  Определение

                  Some observations have multiple component observations. These component observations are expressed as separate code value pairs that share the same attributes. Examples include systolic and diastolic component observations for blood pressure measurement and multiple component observations for genetics observations.

                  КороткийIntramammary lymph node status
                  Комментарии

                  For a discussion on the ways Observations can be assembled in groups together see Notes below.

                  Контроль0..1
                  На этот элемент влияют следующие инварианты: obs-7
                  ТипBackboneElement
                  Модификаторfalse
                  Требуется поддержкаtrue
                  Summarytrue
                  Требования

                  Component observations share the same attributes in the Observation resource as the primary observation and are always treated a part of a single observation (they are not separable). However, the reference range for the primary observation value is not inherited by the component values and is required when appropriate for each component observation.

                  Инвариантыele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
                  380. Observation.component:intramammaryNodeStatus.id
                  Определение

                  Unique id for the element within a resource (for internal references). This may be any string value that does not contain spaces.

                  КороткийUnique id for inter-element referencing
                  Контроль0..1
                  На этот элемент влияют следующие инварианты: ele-1
                  Типstring
                  Модификаторfalse
                  Формат XMLВ формате XML это свойство представлено в качестве атрибута.
                  Summaryfalse
                  382. Observation.component:intramammaryNodeStatus.extension
                  Определение

                  May be used to represent additional information that is not part of the basic definition of the element. To make the use of extensions safe and managable, there is a strict set of governance applied to the definition and use of extensions. Though any implementer can define an extension, there is a set of requirements that SHALL be met as part of the definition of the extension.

                  КороткийAdditional content defined by implementations
                  Комментарии

                  There can be no stigma associated with the use of extensions by any application, project, or standard - regardless of the institution or jurisdiction that uses or defines the extensions. The use of extensions is what allows the FHIR specification to retain a core level of simplicity for everyone.

                  Контроль0..*
                  ТипExtension
                  Модификаторfalse
                  Summaryfalse
                  Альтернативные именаextensions, user content
                  Инвариантыele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
                  ext-1: Must have either extensions or value[x], not both (extension.exists() != value.exists())
                  384. Observation.component:intramammaryNodeStatus.modifierExtension
                  Определение

                  May be used to represent additional information that is not part of the basic definition of the element and that modifies the understanding of the element in which it is contained and/or the understanding of the containing element's descendants. Usually modifier elements provide negation or qualification. To make the use of extensions safe and managable, there is a strict set of governance applied to the definition and use of extensions. Though any implementer can define an extension, there is a set of requirements that SHALL be met as part of the definition of the extension. Applications processing a resource are required to check for modifier extensions.

                  Modifier extensions SHALL NOT change the meaning of any elements on Resource or DomainResource (including cannot change the meaning of modifierExtension itself).

                  КороткийExtensions that cannot be ignored even if unrecognized
                  Комментарии

                  There can be no stigma associated with the use of extensions by any application, project, or standard - regardless of the institution or jurisdiction that uses or defines the extensions. The use of extensions is what allows the FHIR specification to retain a core level of simplicity for everyone.

                  Контроль0..*
                  ТипExtension
                  Модификаторtrue потому что Modifier extensions are expected to modify the meaning or interpretation of the element that contains them
                  Summarytrue
                  Требования

                  Modifier extensions allow for extensions that cannot be safely ignored to be clearly distinguished from the vast majority of extensions which can be safely ignored. This promotes interoperability by eliminating the need for implementers to prohibit the presence of extensions. For further information, see the definition of modifier extensions.

                  Альтернативные именаextensions, user content, modifiers
                  Инвариантыele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
                  ext-1: Must have either extensions or value[x], not both (extension.exists() != value.exists())
                  386. Observation.component:intramammaryNodeStatus.code
                  Определение

                  Describes what was observed. Sometimes this is called the observation "code".

                  КороткийType of component observation (code / type)
                  Комментарии

                  All code-value and component.code-component.value pairs need to be taken into account to correctly understand the meaning of the observation.

                  Контроль1..1
                  На этот элемент влияют следующие инварианты: obs-7
                  ПривязкаКоды СЛЕДУЕТ взять из ObservationCodesVS (0.12.0)
                  (preferred to https://terminology.dhp.uz/fhir/core/ValueSet/observation-codes-vs|0.12.0)
                  ТипCodeableConcept
                  Модификаторfalse
                  Требуется поддержкаtrue
                  Summarytrue
                  Требования

                  Knowing what kind of observation is being made is essential to understanding the observation.

                  Значение шаблона{
                    "coding" : [{
                      "system" : "https://terminology.dhp.uz/fhir/integrations/CodeSystem/screening-ultrasound-parameter-cs",
                      "code" : "scrn-0052-00016"
                    }]
                  }
                  Инвариантыele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
                  388. Observation.component:intramammaryNodeStatus.value[x]
                  Определение

                  The information determined as a result of making the observation, if the information has a simple value.

                  КороткийActual component result
                  Комментарии

                  Used when observation has a set of component observations:

                  • An observation may have both a value (e.g. an Apgar score) and component observations (the observations from which the Apgar score was derived).
                  • If a value is present, the datatype for this element should be determined by the code.
                  • CodeableConcept with just a text would be used instead of a string if the field was usually coded, or if the type associated with the code defines a coded value.
                  • Attachment is used if the observation result value is a binary file such as an image. If the observation result value is derived from the binary file (for example 'X' detected and here is the the proof in this image), the binary file may be directly represented using DocumentReference and referenced by derivedFrom.
                  • If a value is present, the datatype for this element should be determined by the code.
                  • CodeableConcept with just a text would be used instead of a string if the field was usually coded, or if the type associated with the code defines a coded value.
                  • Attachment is used if the observation result value is a binary file such as an image. If the observation result value is derived from the binary file (for example 'X' detected and here is the the proof in this image), the binary file may be directly represented using DocumentReference and referenced by derivedFrom.
                  • The usage of valueReference is restricted to the MolecularSequence resource when used as a definitional resource, not as a patient-specific finding. .
                  • For additional guidance, see the Notes section below.
                  Контроль0..1
                  ПривязкаКоды ДОЛЖНЫ быть взяты из ScreeningUltrasoundIntramammaryNodeStatusVS (0.12.1)
                  (required to https://terminology.dhp.uz/fhir/integrations/ValueSet/screening-ultrasound-intramammary-node-status-vs|0.12.1)
                  ТипCodeableConcept
                  [x] ЗаметкаСмотретьВыбор типов данныхдля дополнительной информации о том, как использовать [x]
                  Модификаторfalse
                  Требуется поддержкаtrue
                  Summarytrue
                  Требования

                  An observation exists to have a value, though it might not if it is in error, or if it represents a group of observations.

                  Инвариантыele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
                  390. Observation.component:intramammaryNodeStatus.dataAbsentReason
                  Определение

                  Provides a reason why the expected value in the element Observation.component.value[x] is missing.

                  КороткийWhy the component result is missing
                  Комментарии

                  "Null" or exceptional values can be represented two ways in FHIR Observations. One way is to simply include them in the value set and represent the exceptions in the value. For example, measurement values for a serology test could be "detected", "not detected", "inconclusive", or "test not done".

                  The alternate way is to use the value element for actual observations and use the explicit dataAbsentReason element to record exceptional values. For example, the dataAbsentReason code "error" could be used when the measurement was not completed. Because of these options, use-case agreements are required to interpret general observations for exceptional values.

                  Контроль0..1
                  ПривязкаЕсли они не подходят, эти коды ДОЛЖНЫ быть взяты из DataAbsentReasonVS (0.12.0)
                  (extensible to https://terminology.dhp.uz/fhir/core/ValueSet/data-absent-reason-vs|0.12.0)
                  ТипCodeableConcept
                  Модификаторfalse
                  Требуется поддержкаfalse
                  Summaryfalse
                  Требования

                  For many results it is necessary to handle exceptional values in measurements.

                  Инвариантыele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
                  392. Observation.component:intramammaryNodeStatus.interpretation
                  Определение

                  A categorical assessment of an observation value. For example, high, low, normal.

                  КороткийHigh, low, normal, etc
                  Комментарии

                  Historically used for laboratory results (known as 'abnormal flag' ), its use extends to other use cases where coded interpretations are relevant. Often reported as one or more simple compact codes this element is often placed adjacent to the result value in reports and flow sheets to signal the meaning/normalcy status of the result.

                  Контроль0..*
                  ПривязкаЕсли они не подходят, эти коды ДОЛЖНЫ быть взяты из ObservationInterpretationVS (0.12.0)
                  (extensible to https://terminology.dhp.uz/fhir/core/ValueSet/observation-interpretation-vs|0.12.0)
                  ТипCodeableConcept
                  Модификаторfalse
                  Требуется поддержкаfalse
                  Summaryfalse
                  Требования

                  For some results, particularly numeric results, an interpretation is necessary to fully understand the significance of a result.

                  Альтернативные именаAbnormal Flag
                  Инвариантыele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
                  394. Observation.component:intramammaryNodeStatus.referenceRange
                  Определение

                  Guidance on how to interpret the value by comparison to a normal or recommended range.

                  КороткийProvides guide for interpretation of component result
                  Комментарии

                  Most observations only have one generic reference range. Systems MAY choose to restrict to only supplying the relevant reference range based on knowledge about the patient (e.g., specific to the patient's age, gender, weight and other factors), but this might not be possible or appropriate. Whenever more than one reference range is supplied, the differences between them SHOULD be provided in the reference range and/or age properties.

                  Контроль0..*
                  ТипСмотретьttp://hl7.org/fhir/StructureDefinition/Observation#Observation.referenceRange
                  Модификаторfalse
                  Требуется поддержкаfalse
                  Summaryfalse
                  Требования

                  Knowing what values are considered "normal" can help evaluate the significance of a particular result. Need to be able to provide multiple reference ranges for different contexts.

                  Инвариантыele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
                  396. Observation.component:axillaryNodeStatus
                  Название разрезаaxillaryNodeStatus
                  Определение

                  Some observations have multiple component observations. These component observations are expressed as separate code value pairs that share the same attributes. Examples include systolic and diastolic component observations for blood pressure measurement and multiple component observations for genetics observations.

                  КороткийAxillary lymph node status
                  Комментарии

                  For a discussion on the ways Observations can be assembled in groups together see Notes below.

                  Контроль0..1
                  На этот элемент влияют следующие инварианты: obs-7
                  ТипBackboneElement
                  Модификаторfalse
                  Требуется поддержкаtrue
                  Summarytrue
                  Требования

                  Component observations share the same attributes in the Observation resource as the primary observation and are always treated a part of a single observation (they are not separable). However, the reference range for the primary observation value is not inherited by the component values and is required when appropriate for each component observation.

                  Инвариантыele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
                  398. Observation.component:axillaryNodeStatus.id
                  Определение

                  Unique id for the element within a resource (for internal references). This may be any string value that does not contain spaces.

                  КороткийUnique id for inter-element referencing
                  Контроль0..1
                  На этот элемент влияют следующие инварианты: ele-1
                  Типstring
                  Модификаторfalse
                  Формат XMLВ формате XML это свойство представлено в качестве атрибута.
                  Summaryfalse
                  400. Observation.component:axillaryNodeStatus.extension
                  Определение

                  May be used to represent additional information that is not part of the basic definition of the element. To make the use of extensions safe and managable, there is a strict set of governance applied to the definition and use of extensions. Though any implementer can define an extension, there is a set of requirements that SHALL be met as part of the definition of the extension.

                  КороткийAdditional content defined by implementations
                  Комментарии

                  There can be no stigma associated with the use of extensions by any application, project, or standard - regardless of the institution or jurisdiction that uses or defines the extensions. The use of extensions is what allows the FHIR specification to retain a core level of simplicity for everyone.

                  Контроль0..*
                  ТипExtension
                  Модификаторfalse
                  Summaryfalse
                  Альтернативные именаextensions, user content
                  Инвариантыele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
                  ext-1: Must have either extensions or value[x], not both (extension.exists() != value.exists())
                  402. Observation.component:axillaryNodeStatus.modifierExtension
                  Определение

                  May be used to represent additional information that is not part of the basic definition of the element and that modifies the understanding of the element in which it is contained and/or the understanding of the containing element's descendants. Usually modifier elements provide negation or qualification. To make the use of extensions safe and managable, there is a strict set of governance applied to the definition and use of extensions. Though any implementer can define an extension, there is a set of requirements that SHALL be met as part of the definition of the extension. Applications processing a resource are required to check for modifier extensions.

                  Modifier extensions SHALL NOT change the meaning of any elements on Resource or DomainResource (including cannot change the meaning of modifierExtension itself).

                  КороткийExtensions that cannot be ignored even if unrecognized
                  Комментарии

                  There can be no stigma associated with the use of extensions by any application, project, or standard - regardless of the institution or jurisdiction that uses or defines the extensions. The use of extensions is what allows the FHIR specification to retain a core level of simplicity for everyone.

                  Контроль0..*
                  ТипExtension
                  Модификаторtrue потому что Modifier extensions are expected to modify the meaning or interpretation of the element that contains them
                  Summarytrue
                  Требования

                  Modifier extensions allow for extensions that cannot be safely ignored to be clearly distinguished from the vast majority of extensions which can be safely ignored. This promotes interoperability by eliminating the need for implementers to prohibit the presence of extensions. For further information, see the definition of modifier extensions.

                  Альтернативные именаextensions, user content, modifiers
                  Инвариантыele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
                  ext-1: Must have either extensions or value[x], not both (extension.exists() != value.exists())
                  404. Observation.component:axillaryNodeStatus.code
                  Определение

                  Describes what was observed. Sometimes this is called the observation "code".

                  КороткийType of component observation (code / type)
                  Комментарии

                  All code-value and component.code-component.value pairs need to be taken into account to correctly understand the meaning of the observation.

                  Контроль1..1
                  На этот элемент влияют следующие инварианты: obs-7
                  ПривязкаКоды СЛЕДУЕТ взять из ObservationCodesVS (0.12.0)
                  (preferred to https://terminology.dhp.uz/fhir/core/ValueSet/observation-codes-vs|0.12.0)
                  ТипCodeableConcept
                  Модификаторfalse
                  Требуется поддержкаtrue
                  Summarytrue
                  Требования

                  Knowing what kind of observation is being made is essential to understanding the observation.

                  Значение шаблона{
                    "coding" : [{
                      "system" : "https://terminology.dhp.uz/fhir/integrations/CodeSystem/screening-ultrasound-parameter-cs",
                      "code" : "scrn-0052-00017"
                    }]
                  }
                  Инвариантыele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
                  406. Observation.component:axillaryNodeStatus.value[x]
                  Определение

                  The information determined as a result of making the observation, if the information has a simple value.

                  КороткийActual component result
                  Комментарии

                  Used when observation has a set of component observations:

                  • An observation may have both a value (e.g. an Apgar score) and component observations (the observations from which the Apgar score was derived).
                  • If a value is present, the datatype for this element should be determined by the code.
                  • CodeableConcept with just a text would be used instead of a string if the field was usually coded, or if the type associated with the code defines a coded value.
                  • Attachment is used if the observation result value is a binary file such as an image. If the observation result value is derived from the binary file (for example 'X' detected and here is the the proof in this image), the binary file may be directly represented using DocumentReference and referenced by derivedFrom.
                  • If a value is present, the datatype for this element should be determined by the code.
                  • CodeableConcept with just a text would be used instead of a string if the field was usually coded, or if the type associated with the code defines a coded value.
                  • Attachment is used if the observation result value is a binary file such as an image. If the observation result value is derived from the binary file (for example 'X' detected and here is the the proof in this image), the binary file may be directly represented using DocumentReference and referenced by derivedFrom.
                  • The usage of valueReference is restricted to the MolecularSequence resource when used as a definitional resource, not as a patient-specific finding. .
                  • For additional guidance, see the Notes section below.
                  Контроль0..1
                  ПривязкаКоды ДОЛЖНЫ быть взяты из ScreeningUltrasoundAxillaryNodeStatusVS (0.12.1)
                  (required to https://terminology.dhp.uz/fhir/integrations/ValueSet/screening-ultrasound-axillary-node-status-vs|0.12.1)
                  ТипCodeableConcept
                  [x] ЗаметкаСмотретьВыбор типов данныхдля дополнительной информации о том, как использовать [x]
                  Модификаторfalse
                  Требуется поддержкаtrue
                  Summarytrue
                  Требования

                  An observation exists to have a value, though it might not if it is in error, or if it represents a group of observations.

                  Инвариантыele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
                  408. Observation.component:axillaryNodeStatus.dataAbsentReason
                  Определение

                  Provides a reason why the expected value in the element Observation.component.value[x] is missing.

                  КороткийWhy the component result is missing
                  Комментарии

                  "Null" or exceptional values can be represented two ways in FHIR Observations. One way is to simply include them in the value set and represent the exceptions in the value. For example, measurement values for a serology test could be "detected", "not detected", "inconclusive", or "test not done".

                  The alternate way is to use the value element for actual observations and use the explicit dataAbsentReason element to record exceptional values. For example, the dataAbsentReason code "error" could be used when the measurement was not completed. Because of these options, use-case agreements are required to interpret general observations for exceptional values.

                  Контроль0..1
                  ПривязкаЕсли они не подходят, эти коды ДОЛЖНЫ быть взяты из DataAbsentReasonVS (0.12.0)
                  (extensible to https://terminology.dhp.uz/fhir/core/ValueSet/data-absent-reason-vs|0.12.0)
                  ТипCodeableConcept
                  Модификаторfalse
                  Требуется поддержкаfalse
                  Summaryfalse
                  Требования

                  For many results it is necessary to handle exceptional values in measurements.

                  Инвариантыele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
                  410. Observation.component:axillaryNodeStatus.interpretation
                  Определение

                  A categorical assessment of an observation value. For example, high, low, normal.

                  КороткийHigh, low, normal, etc
                  Комментарии

                  Historically used for laboratory results (known as 'abnormal flag' ), its use extends to other use cases where coded interpretations are relevant. Often reported as one or more simple compact codes this element is often placed adjacent to the result value in reports and flow sheets to signal the meaning/normalcy status of the result.

                  Контроль0..*
                  ПривязкаЕсли они не подходят, эти коды ДОЛЖНЫ быть взяты из ObservationInterpretationVS (0.12.0)
                  (extensible to https://terminology.dhp.uz/fhir/core/ValueSet/observation-interpretation-vs|0.12.0)
                  ТипCodeableConcept
                  Модификаторfalse
                  Требуется поддержкаfalse
                  Summaryfalse
                  Требования

                  For some results, particularly numeric results, an interpretation is necessary to fully understand the significance of a result.

                  Альтернативные именаAbnormal Flag
                  Инвариантыele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
                  412. Observation.component:axillaryNodeStatus.referenceRange
                  Определение

                  Guidance on how to interpret the value by comparison to a normal or recommended range.

                  КороткийProvides guide for interpretation of component result
                  Комментарии

                  Most observations only have one generic reference range. Systems MAY choose to restrict to only supplying the relevant reference range based on knowledge about the patient (e.g., specific to the patient's age, gender, weight and other factors), but this might not be possible or appropriate. Whenever more than one reference range is supplied, the differences between them SHOULD be provided in the reference range and/or age properties.

                  Контроль0..*
                  ТипСмотретьttp://hl7.org/fhir/StructureDefinition/Observation#Observation.referenceRange
                  Модификаторfalse
                  Требуется поддержкаfalse
                  Summaryfalse
                  Требования

                  Knowing what values are considered "normal" can help evaluate the significance of a particular result. Need to be able to provide multiple reference ranges for different contexts.

                  Инвариантыele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
                  414. Observation.component:axillaryNodeDifferentiation
                  Название разрезаaxillaryNodeDifferentiation
                  Определение

                  Some observations have multiple component observations. These component observations are expressed as separate code value pairs that share the same attributes. Examples include systolic and diastolic component observations for blood pressure measurement and multiple component observations for genetics observations.

                  КороткийAxillary lymph node differentiation
                  Комментарии

                  For a discussion on the ways Observations can be assembled in groups together see Notes below.

                  Контроль0..1
                  На этот элемент влияют следующие инварианты: obs-7
                  ТипBackboneElement
                  Модификаторfalse
                  Требуется поддержкаtrue
                  Summarytrue
                  Требования

                  Component observations share the same attributes in the Observation resource as the primary observation and are always treated a part of a single observation (they are not separable). However, the reference range for the primary observation value is not inherited by the component values and is required when appropriate for each component observation.

                  Инвариантыele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
                  416. Observation.component:axillaryNodeDifferentiation.id
                  Определение

                  Unique id for the element within a resource (for internal references). This may be any string value that does not contain spaces.

                  КороткийUnique id for inter-element referencing
                  Контроль0..1
                  На этот элемент влияют следующие инварианты: ele-1
                  Типstring
                  Модификаторfalse
                  Формат XMLВ формате XML это свойство представлено в качестве атрибута.
                  Summaryfalse
                  418. Observation.component:axillaryNodeDifferentiation.extension
                  Определение

                  May be used to represent additional information that is not part of the basic definition of the element. To make the use of extensions safe and managable, there is a strict set of governance applied to the definition and use of extensions. Though any implementer can define an extension, there is a set of requirements that SHALL be met as part of the definition of the extension.

                  КороткийAdditional content defined by implementations
                  Комментарии

                  There can be no stigma associated with the use of extensions by any application, project, or standard - regardless of the institution or jurisdiction that uses or defines the extensions. The use of extensions is what allows the FHIR specification to retain a core level of simplicity for everyone.

                  Контроль0..*
                  ТипExtension
                  Модификаторfalse
                  Summaryfalse
                  Альтернативные именаextensions, user content
                  Инвариантыele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
                  ext-1: Must have either extensions or value[x], not both (extension.exists() != value.exists())
                  420. Observation.component:axillaryNodeDifferentiation.modifierExtension
                  Определение

                  May be used to represent additional information that is not part of the basic definition of the element and that modifies the understanding of the element in which it is contained and/or the understanding of the containing element's descendants. Usually modifier elements provide negation or qualification. To make the use of extensions safe and managable, there is a strict set of governance applied to the definition and use of extensions. Though any implementer can define an extension, there is a set of requirements that SHALL be met as part of the definition of the extension. Applications processing a resource are required to check for modifier extensions.

                  Modifier extensions SHALL NOT change the meaning of any elements on Resource or DomainResource (including cannot change the meaning of modifierExtension itself).

                  КороткийExtensions that cannot be ignored even if unrecognized
                  Комментарии

                  There can be no stigma associated with the use of extensions by any application, project, or standard - regardless of the institution or jurisdiction that uses or defines the extensions. The use of extensions is what allows the FHIR specification to retain a core level of simplicity for everyone.

                  Контроль0..*
                  ТипExtension
                  Модификаторtrue потому что Modifier extensions are expected to modify the meaning or interpretation of the element that contains them
                  Summarytrue
                  Требования

                  Modifier extensions allow for extensions that cannot be safely ignored to be clearly distinguished from the vast majority of extensions which can be safely ignored. This promotes interoperability by eliminating the need for implementers to prohibit the presence of extensions. For further information, see the definition of modifier extensions.

                  Альтернативные именаextensions, user content, modifiers
                  Инвариантыele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
                  ext-1: Must have either extensions or value[x], not both (extension.exists() != value.exists())
                  422. Observation.component:axillaryNodeDifferentiation.code
                  Определение

                  Describes what was observed. Sometimes this is called the observation "code".

                  КороткийType of component observation (code / type)
                  Комментарии

                  All code-value and component.code-component.value pairs need to be taken into account to correctly understand the meaning of the observation.

                  Контроль1..1
                  На этот элемент влияют следующие инварианты: obs-7
                  ПривязкаКоды СЛЕДУЕТ взять из ObservationCodesVS (0.12.0)
                  (preferred to https://terminology.dhp.uz/fhir/core/ValueSet/observation-codes-vs|0.12.0)
                  ТипCodeableConcept
                  Модификаторfalse
                  Требуется поддержкаtrue
                  Summarytrue
                  Требования

                  Knowing what kind of observation is being made is essential to understanding the observation.

                  Значение шаблона{
                    "coding" : [{
                      "system" : "https://terminology.dhp.uz/fhir/integrations/CodeSystem/screening-specialized-observation-parameter-cs",
                      "code" : "scrn-0073-00016"
                    }]
                  }
                  Инвариантыele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
                  424. Observation.component:axillaryNodeDifferentiation.value[x]
                  Определение

                  The information determined as a result of making the observation, if the information has a simple value.

                  КороткийActual component result
                  Комментарии

                  Used when observation has a set of component observations:

                  • An observation may have both a value (e.g. an Apgar score) and component observations (the observations from which the Apgar score was derived).
                  • If a value is present, the datatype for this element should be determined by the code.
                  • CodeableConcept with just a text would be used instead of a string if the field was usually coded, or if the type associated with the code defines a coded value.
                  • Attachment is used if the observation result value is a binary file such as an image. If the observation result value is derived from the binary file (for example 'X' detected and here is the the proof in this image), the binary file may be directly represented using DocumentReference and referenced by derivedFrom.
                  • If a value is present, the datatype for this element should be determined by the code.
                  • CodeableConcept with just a text would be used instead of a string if the field was usually coded, or if the type associated with the code defines a coded value.
                  • Attachment is used if the observation result value is a binary file such as an image. If the observation result value is derived from the binary file (for example 'X' detected and here is the the proof in this image), the binary file may be directly represented using DocumentReference and referenced by derivedFrom.
                  • The usage of valueReference is restricted to the MolecularSequence resource when used as a definitional resource, not as a patient-specific finding. .
                  • For additional guidance, see the Notes section below.
                  Контроль0..1
                  ПривязкаКоды ДОЛЖНЫ быть взяты из ScreeningUltrasoundAxillaryNodeDifferentiationVS (0.12.1)
                  (required to https://terminology.dhp.uz/fhir/integrations/ValueSet/screening-ultrasound-axillary-node-differentiation-vs|0.12.1)
                  ТипCodeableConcept
                  [x] ЗаметкаСмотретьВыбор типов данныхдля дополнительной информации о том, как использовать [x]
                  Модификаторfalse
                  Требуется поддержкаtrue
                  Summarytrue
                  Требования

                  An observation exists to have a value, though it might not if it is in error, or if it represents a group of observations.

                  Инвариантыele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
                  426. Observation.component:axillaryNodeDifferentiation.dataAbsentReason
                  Определение

                  Provides a reason why the expected value in the element Observation.component.value[x] is missing.

                  КороткийWhy the component result is missing
                  Комментарии

                  "Null" or exceptional values can be represented two ways in FHIR Observations. One way is to simply include them in the value set and represent the exceptions in the value. For example, measurement values for a serology test could be "detected", "not detected", "inconclusive", or "test not done".

                  The alternate way is to use the value element for actual observations and use the explicit dataAbsentReason element to record exceptional values. For example, the dataAbsentReason code "error" could be used when the measurement was not completed. Because of these options, use-case agreements are required to interpret general observations for exceptional values.

                  Контроль0..1
                  ПривязкаЕсли они не подходят, эти коды ДОЛЖНЫ быть взяты из DataAbsentReasonVS (0.12.0)
                  (extensible to https://terminology.dhp.uz/fhir/core/ValueSet/data-absent-reason-vs|0.12.0)
                  ТипCodeableConcept
                  Модификаторfalse
                  Требуется поддержкаfalse
                  Summaryfalse
                  Требования

                  For many results it is necessary to handle exceptional values in measurements.

                  Инвариантыele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
                  428. Observation.component:axillaryNodeDifferentiation.interpretation
                  Определение

                  A categorical assessment of an observation value. For example, high, low, normal.

                  КороткийHigh, low, normal, etc
                  Комментарии

                  Historically used for laboratory results (known as 'abnormal flag' ), its use extends to other use cases where coded interpretations are relevant. Often reported as one or more simple compact codes this element is often placed adjacent to the result value in reports and flow sheets to signal the meaning/normalcy status of the result.

                  Контроль0..*
                  ПривязкаЕсли они не подходят, эти коды ДОЛЖНЫ быть взяты из ObservationInterpretationVS (0.12.0)
                  (extensible to https://terminology.dhp.uz/fhir/core/ValueSet/observation-interpretation-vs|0.12.0)
                  ТипCodeableConcept
                  Модификаторfalse
                  Требуется поддержкаfalse
                  Summaryfalse
                  Требования

                  For some results, particularly numeric results, an interpretation is necessary to fully understand the significance of a result.

                  Альтернативные именаAbnormal Flag
                  Инвариантыele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
                  430. Observation.component:axillaryNodeDifferentiation.referenceRange
                  Определение

                  Guidance on how to interpret the value by comparison to a normal or recommended range.

                  КороткийProvides guide for interpretation of component result
                  Комментарии

                  Most observations only have one generic reference range. Systems MAY choose to restrict to only supplying the relevant reference range based on knowledge about the patient (e.g., specific to the patient's age, gender, weight and other factors), but this might not be possible or appropriate. Whenever more than one reference range is supplied, the differences between them SHOULD be provided in the reference range and/or age properties.

                  Контроль0..*
                  ТипСмотретьttp://hl7.org/fhir/StructureDefinition/Observation#Observation.referenceRange
                  Модификаторfalse
                  Требуется поддержкаfalse
                  Summaryfalse
                  Требования

                  Knowing what values are considered "normal" can help evaluate the significance of a particular result. Need to be able to provide multiple reference ranges for different contexts.

                  Инвариантыele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
                  432. Observation.component:regionalNodeStatus
                  Название разрезаregionalNodeStatus
                  Определение

                  Some observations have multiple component observations. These component observations are expressed as separate code value pairs that share the same attributes. Examples include systolic and diastolic component observations for blood pressure measurement and multiple component observations for genetics observations.

                  КороткийRegional lymph node status
                  Комментарии

                  For a discussion on the ways Observations can be assembled in groups together see Notes below.

                  Контроль0..1
                  На этот элемент влияют следующие инварианты: obs-7
                  ТипBackboneElement
                  Модификаторfalse
                  Требуется поддержкаtrue
                  Summarytrue
                  Требования

                  Component observations share the same attributes in the Observation resource as the primary observation and are always treated a part of a single observation (they are not separable). However, the reference range for the primary observation value is not inherited by the component values and is required when appropriate for each component observation.

                  Инвариантыele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
                  434. Observation.component:regionalNodeStatus.id
                  Определение

                  Unique id for the element within a resource (for internal references). This may be any string value that does not contain spaces.

                  КороткийUnique id for inter-element referencing
                  Контроль0..1
                  На этот элемент влияют следующие инварианты: ele-1
                  Типstring
                  Модификаторfalse
                  Формат XMLВ формате XML это свойство представлено в качестве атрибута.
                  Summaryfalse
                  436. Observation.component:regionalNodeStatus.extension
                  Определение

                  May be used to represent additional information that is not part of the basic definition of the element. To make the use of extensions safe and managable, there is a strict set of governance applied to the definition and use of extensions. Though any implementer can define an extension, there is a set of requirements that SHALL be met as part of the definition of the extension.

                  КороткийAdditional content defined by implementations
                  Комментарии

                  There can be no stigma associated with the use of extensions by any application, project, or standard - regardless of the institution or jurisdiction that uses or defines the extensions. The use of extensions is what allows the FHIR specification to retain a core level of simplicity for everyone.

                  Контроль0..*
                  ТипExtension
                  Модификаторfalse
                  Summaryfalse
                  Альтернативные именаextensions, user content
                  Инвариантыele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
                  ext-1: Must have either extensions or value[x], not both (extension.exists() != value.exists())
                  438. Observation.component:regionalNodeStatus.modifierExtension
                  Определение

                  May be used to represent additional information that is not part of the basic definition of the element and that modifies the understanding of the element in which it is contained and/or the understanding of the containing element's descendants. Usually modifier elements provide negation or qualification. To make the use of extensions safe and managable, there is a strict set of governance applied to the definition and use of extensions. Though any implementer can define an extension, there is a set of requirements that SHALL be met as part of the definition of the extension. Applications processing a resource are required to check for modifier extensions.

                  Modifier extensions SHALL NOT change the meaning of any elements on Resource or DomainResource (including cannot change the meaning of modifierExtension itself).

                  КороткийExtensions that cannot be ignored even if unrecognized
                  Комментарии

                  There can be no stigma associated with the use of extensions by any application, project, or standard - regardless of the institution or jurisdiction that uses or defines the extensions. The use of extensions is what allows the FHIR specification to retain a core level of simplicity for everyone.

                  Контроль0..*
                  ТипExtension
                  Модификаторtrue потому что Modifier extensions are expected to modify the meaning or interpretation of the element that contains them
                  Summarytrue
                  Требования

                  Modifier extensions allow for extensions that cannot be safely ignored to be clearly distinguished from the vast majority of extensions which can be safely ignored. This promotes interoperability by eliminating the need for implementers to prohibit the presence of extensions. For further information, see the definition of modifier extensions.

                  Альтернативные именаextensions, user content, modifiers
                  Инвариантыele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
                  ext-1: Must have either extensions or value[x], not both (extension.exists() != value.exists())
                  440. Observation.component:regionalNodeStatus.code
                  Определение

                  Describes what was observed. Sometimes this is called the observation "code".

                  КороткийType of component observation (code / type)
                  Комментарии

                  All code-value and component.code-component.value pairs need to be taken into account to correctly understand the meaning of the observation.

                  Контроль1..1
                  На этот элемент влияют следующие инварианты: obs-7
                  ПривязкаКоды СЛЕДУЕТ взять из ObservationCodesVS (0.12.0)
                  (preferred to https://terminology.dhp.uz/fhir/core/ValueSet/observation-codes-vs|0.12.0)
                  ТипCodeableConcept
                  Модификаторfalse
                  Требуется поддержкаtrue
                  Summarytrue
                  Требования

                  Knowing what kind of observation is being made is essential to understanding the observation.

                  Значение шаблона{
                    "coding" : [{
                      "system" : "https://terminology.dhp.uz/fhir/integrations/CodeSystem/screening-ultrasound-parameter-cs",
                      "code" : "scrn-0052-00018"
                    }]
                  }
                  Инвариантыele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
                  442. Observation.component:regionalNodeStatus.value[x]
                  Определение

                  The information determined as a result of making the observation, if the information has a simple value.

                  КороткийActual component result
                  Комментарии

                  Used when observation has a set of component observations:

                  • An observation may have both a value (e.g. an Apgar score) and component observations (the observations from which the Apgar score was derived).
                  • If a value is present, the datatype for this element should be determined by the code.
                  • CodeableConcept with just a text would be used instead of a string if the field was usually coded, or if the type associated with the code defines a coded value.
                  • Attachment is used if the observation result value is a binary file such as an image. If the observation result value is derived from the binary file (for example 'X' detected and here is the the proof in this image), the binary file may be directly represented using DocumentReference and referenced by derivedFrom.
                  • If a value is present, the datatype for this element should be determined by the code.
                  • CodeableConcept with just a text would be used instead of a string if the field was usually coded, or if the type associated with the code defines a coded value.
                  • Attachment is used if the observation result value is a binary file such as an image. If the observation result value is derived from the binary file (for example 'X' detected and here is the the proof in this image), the binary file may be directly represented using DocumentReference and referenced by derivedFrom.
                  • The usage of valueReference is restricted to the MolecularSequence resource when used as a definitional resource, not as a patient-specific finding. .
                  • For additional guidance, see the Notes section below.
                  Контроль0..1
                  ПривязкаКоды ДОЛЖНЫ быть взяты из ScreeningUltrasoundRegionalNodeStatusVS (0.12.1)
                  (required to https://terminology.dhp.uz/fhir/integrations/ValueSet/screening-ultrasound-regional-node-status-vs|0.12.1)
                  ТипCodeableConcept
                  [x] ЗаметкаСмотретьВыбор типов данныхдля дополнительной информации о том, как использовать [x]
                  Модификаторfalse
                  Требуется поддержкаtrue
                  Summarytrue
                  Требования

                  An observation exists to have a value, though it might not if it is in error, or if it represents a group of observations.

                  Инвариантыele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
                  444. Observation.component:regionalNodeStatus.dataAbsentReason
                  Определение

                  Provides a reason why the expected value in the element Observation.component.value[x] is missing.

                  КороткийWhy the component result is missing
                  Комментарии

                  "Null" or exceptional values can be represented two ways in FHIR Observations. One way is to simply include them in the value set and represent the exceptions in the value. For example, measurement values for a serology test could be "detected", "not detected", "inconclusive", or "test not done".

                  The alternate way is to use the value element for actual observations and use the explicit dataAbsentReason element to record exceptional values. For example, the dataAbsentReason code "error" could be used when the measurement was not completed. Because of these options, use-case agreements are required to interpret general observations for exceptional values.

                  Контроль0..1
                  ПривязкаЕсли они не подходят, эти коды ДОЛЖНЫ быть взяты из DataAbsentReasonVS (0.12.0)
                  (extensible to https://terminology.dhp.uz/fhir/core/ValueSet/data-absent-reason-vs|0.12.0)
                  ТипCodeableConcept
                  Модификаторfalse
                  Требуется поддержкаfalse
                  Summaryfalse
                  Требования

                  For many results it is necessary to handle exceptional values in measurements.

                  Инвариантыele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
                  446. Observation.component:regionalNodeStatus.interpretation
                  Определение

                  A categorical assessment of an observation value. For example, high, low, normal.

                  КороткийHigh, low, normal, etc
                  Комментарии

                  Historically used for laboratory results (known as 'abnormal flag' ), its use extends to other use cases where coded interpretations are relevant. Often reported as one or more simple compact codes this element is often placed adjacent to the result value in reports and flow sheets to signal the meaning/normalcy status of the result.

                  Контроль0..*
                  ПривязкаЕсли они не подходят, эти коды ДОЛЖНЫ быть взяты из ObservationInterpretationVS (0.12.0)
                  (extensible to https://terminology.dhp.uz/fhir/core/ValueSet/observation-interpretation-vs|0.12.0)
                  ТипCodeableConcept
                  Модификаторfalse
                  Требуется поддержкаfalse
                  Summaryfalse
                  Требования

                  For some results, particularly numeric results, an interpretation is necessary to fully understand the significance of a result.

                  Альтернативные именаAbnormal Flag
                  Инвариантыele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
                  448. Observation.component:regionalNodeStatus.referenceRange
                  Определение

                  Guidance on how to interpret the value by comparison to a normal or recommended range.

                  КороткийProvides guide for interpretation of component result
                  Комментарии

                  Most observations only have one generic reference range. Systems MAY choose to restrict to only supplying the relevant reference range based on knowledge about the patient (e.g., specific to the patient's age, gender, weight and other factors), but this might not be possible or appropriate. Whenever more than one reference range is supplied, the differences between them SHOULD be provided in the reference range and/or age properties.

                  Контроль0..*
                  ТипСмотретьttp://hl7.org/fhir/StructureDefinition/Observation#Observation.referenceRange
                  Модификаторfalse
                  Требуется поддержкаfalse
                  Summaryfalse
                  Требования

                  Knowing what values are considered "normal" can help evaluate the significance of a particular result. Need to be able to provide multiple reference ranges for different contexts.

                  Инвариантыele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
                  450. Observation.component:dynamics
                  Название разрезаdynamics
                  Определение

                  Some observations have multiple component observations. These component observations are expressed as separate code value pairs that share the same attributes. Examples include systolic and diastolic component observations for blood pressure measurement and multiple component observations for genetics observations.

                  КороткийComparison with previous study
                  Комментарии

                  For a discussion on the ways Observations can be assembled in groups together see Notes below.

                  Контроль0..1
                  На этот элемент влияют следующие инварианты: obs-7
                  ТипBackboneElement
                  Модификаторfalse
                  Требуется поддержкаtrue
                  Summarytrue
                  Требования

                  Component observations share the same attributes in the Observation resource as the primary observation and are always treated a part of a single observation (they are not separable). However, the reference range for the primary observation value is not inherited by the component values and is required when appropriate for each component observation.

                  Инвариантыele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
                  452. Observation.component:dynamics.id
                  Определение

                  Unique id for the element within a resource (for internal references). This may be any string value that does not contain spaces.

                  КороткийUnique id for inter-element referencing
                  Контроль0..1
                  На этот элемент влияют следующие инварианты: ele-1
                  Типstring
                  Модификаторfalse
                  Формат XMLВ формате XML это свойство представлено в качестве атрибута.
                  Summaryfalse
                  454. Observation.component:dynamics.extension
                  Определение

                  May be used to represent additional information that is not part of the basic definition of the element. To make the use of extensions safe and managable, there is a strict set of governance applied to the definition and use of extensions. Though any implementer can define an extension, there is a set of requirements that SHALL be met as part of the definition of the extension.

                  КороткийAdditional content defined by implementations
                  Комментарии

                  There can be no stigma associated with the use of extensions by any application, project, or standard - regardless of the institution or jurisdiction that uses or defines the extensions. The use of extensions is what allows the FHIR specification to retain a core level of simplicity for everyone.

                  Контроль0..*
                  ТипExtension
                  Модификаторfalse
                  Summaryfalse
                  Альтернативные именаextensions, user content
                  Инвариантыele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
                  ext-1: Must have either extensions or value[x], not both (extension.exists() != value.exists())
                  456. Observation.component:dynamics.modifierExtension
                  Определение

                  May be used to represent additional information that is not part of the basic definition of the element and that modifies the understanding of the element in which it is contained and/or the understanding of the containing element's descendants. Usually modifier elements provide negation or qualification. To make the use of extensions safe and managable, there is a strict set of governance applied to the definition and use of extensions. Though any implementer can define an extension, there is a set of requirements that SHALL be met as part of the definition of the extension. Applications processing a resource are required to check for modifier extensions.

                  Modifier extensions SHALL NOT change the meaning of any elements on Resource or DomainResource (including cannot change the meaning of modifierExtension itself).

                  КороткийExtensions that cannot be ignored even if unrecognized
                  Комментарии

                  There can be no stigma associated with the use of extensions by any application, project, or standard - regardless of the institution or jurisdiction that uses or defines the extensions. The use of extensions is what allows the FHIR specification to retain a core level of simplicity for everyone.

                  Контроль0..*
                  ТипExtension
                  Модификаторtrue потому что Modifier extensions are expected to modify the meaning or interpretation of the element that contains them
                  Summarytrue
                  Требования

                  Modifier extensions allow for extensions that cannot be safely ignored to be clearly distinguished from the vast majority of extensions which can be safely ignored. This promotes interoperability by eliminating the need for implementers to prohibit the presence of extensions. For further information, see the definition of modifier extensions.

                  Альтернативные именаextensions, user content, modifiers
                  Инвариантыele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
                  ext-1: Must have either extensions or value[x], not both (extension.exists() != value.exists())
                  458. Observation.component:dynamics.code
                  Определение

                  Describes what was observed. Sometimes this is called the observation "code".

                  КороткийType of component observation (code / type)
                  Комментарии

                  All code-value and component.code-component.value pairs need to be taken into account to correctly understand the meaning of the observation.

                  Контроль1..1
                  На этот элемент влияют следующие инварианты: obs-7
                  ПривязкаКоды СЛЕДУЕТ взять из ObservationCodesVS (0.12.0)
                  (preferred to https://terminology.dhp.uz/fhir/core/ValueSet/observation-codes-vs|0.12.0)
                  ТипCodeableConcept
                  Модификаторfalse
                  Требуется поддержкаtrue
                  Summarytrue
                  Требования

                  Knowing what kind of observation is being made is essential to understanding the observation.

                  Значение шаблона{
                    "coding" : [{
                      "system" : "https://terminology.dhp.uz/fhir/integrations/CodeSystem/screening-ultrasound-parameter-cs",
                      "code" : "scrn-0052-00020"
                    }]
                  }
                  Инвариантыele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
                  460. Observation.component:dynamics.value[x]
                  Определение

                  The information determined as a result of making the observation, if the information has a simple value.

                  КороткийActual component result
                  Комментарии

                  Used when observation has a set of component observations:

                  • An observation may have both a value (e.g. an Apgar score) and component observations (the observations from which the Apgar score was derived).
                  • If a value is present, the datatype for this element should be determined by the code.
                  • CodeableConcept with just a text would be used instead of a string if the field was usually coded, or if the type associated with the code defines a coded value.
                  • Attachment is used if the observation result value is a binary file such as an image. If the observation result value is derived from the binary file (for example 'X' detected and here is the the proof in this image), the binary file may be directly represented using DocumentReference and referenced by derivedFrom.
                  • If a value is present, the datatype for this element should be determined by the code.
                  • CodeableConcept with just a text would be used instead of a string if the field was usually coded, or if the type associated with the code defines a coded value.
                  • Attachment is used if the observation result value is a binary file such as an image. If the observation result value is derived from the binary file (for example 'X' detected and here is the the proof in this image), the binary file may be directly represented using DocumentReference and referenced by derivedFrom.
                  • The usage of valueReference is restricted to the MolecularSequence resource when used as a definitional resource, not as a patient-specific finding. .
                  • For additional guidance, see the Notes section below.
                  Контроль0..1
                  ПривязкаКоды ДОЛЖНЫ быть взяты из ScreeningUltrasoundDynamicsVS (0.12.1)
                  (required to https://terminology.dhp.uz/fhir/integrations/ValueSet/screening-ultrasound-dynamics-vs|0.12.1)
                  ТипCodeableConcept
                  [x] ЗаметкаСмотретьВыбор типов данныхдля дополнительной информации о том, как использовать [x]
                  Модификаторfalse
                  Требуется поддержкаtrue
                  Summarytrue
                  Требования

                  An observation exists to have a value, though it might not if it is in error, or if it represents a group of observations.

                  Инвариантыele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
                  462. Observation.component:dynamics.dataAbsentReason
                  Определение

                  Provides a reason why the expected value in the element Observation.component.value[x] is missing.

                  КороткийWhy the component result is missing
                  Комментарии

                  "Null" or exceptional values can be represented two ways in FHIR Observations. One way is to simply include them in the value set and represent the exceptions in the value. For example, measurement values for a serology test could be "detected", "not detected", "inconclusive", or "test not done".

                  The alternate way is to use the value element for actual observations and use the explicit dataAbsentReason element to record exceptional values. For example, the dataAbsentReason code "error" could be used when the measurement was not completed. Because of these options, use-case agreements are required to interpret general observations for exceptional values.

                  Контроль0..1
                  ПривязкаЕсли они не подходят, эти коды ДОЛЖНЫ быть взяты из DataAbsentReasonVS (0.12.0)
                  (extensible to https://terminology.dhp.uz/fhir/core/ValueSet/data-absent-reason-vs|0.12.0)
                  ТипCodeableConcept
                  Модификаторfalse
                  Требуется поддержкаfalse
                  Summaryfalse
                  Требования

                  For many results it is necessary to handle exceptional values in measurements.

                  Инвариантыele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
                  464. Observation.component:dynamics.interpretation
                  Определение

                  A categorical assessment of an observation value. For example, high, low, normal.

                  КороткийHigh, low, normal, etc
                  Комментарии

                  Historically used for laboratory results (known as 'abnormal flag' ), its use extends to other use cases where coded interpretations are relevant. Often reported as one or more simple compact codes this element is often placed adjacent to the result value in reports and flow sheets to signal the meaning/normalcy status of the result.

                  Контроль0..*
                  ПривязкаЕсли они не подходят, эти коды ДОЛЖНЫ быть взяты из ObservationInterpretationVS (0.12.0)
                  (extensible to https://terminology.dhp.uz/fhir/core/ValueSet/observation-interpretation-vs|0.12.0)
                  ТипCodeableConcept
                  Модификаторfalse
                  Требуется поддержкаfalse
                  Summaryfalse
                  Требования

                  For some results, particularly numeric results, an interpretation is necessary to fully understand the significance of a result.

                  Альтернативные именаAbnormal Flag
                  Инвариантыele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
                  466. Observation.component:dynamics.referenceRange
                  Определение

                  Guidance on how to interpret the value by comparison to a normal or recommended range.

                  КороткийProvides guide for interpretation of component result
                  Комментарии

                  Most observations only have one generic reference range. Systems MAY choose to restrict to only supplying the relevant reference range based on knowledge about the patient (e.g., specific to the patient's age, gender, weight and other factors), but this might not be possible or appropriate. Whenever more than one reference range is supplied, the differences between them SHOULD be provided in the reference range and/or age properties.

                  Контроль0..*
                  ТипСмотретьttp://hl7.org/fhir/StructureDefinition/Observation#Observation.referenceRange
                  Модификаторfalse
                  Требуется поддержкаfalse
                  Summaryfalse
                  Требования

                  Knowing what values are considered "normal" can help evaluate the significance of a particular result. Need to be able to provide multiple reference ranges for different contexts.

                  Инвариантыele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
                  468. Observation.component:breastQuadrant
                  Название разрезаbreastQuadrant
                  Определение

                  Some observations have multiple component observations. These component observations are expressed as separate code value pairs that share the same attributes. Examples include systolic and diastolic component observations for blood pressure measurement and multiple component observations for genetics observations.

                  КороткийBreast quadrant
                  Комментарии

                  For a discussion on the ways Observations can be assembled in groups together see Notes below.

                  Контроль0..1
                  На этот элемент влияют следующие инварианты: obs-7
                  ТипBackboneElement
                  Модификаторfalse
                  Требуется поддержкаtrue
                  Summarytrue
                  Требования

                  Component observations share the same attributes in the Observation resource as the primary observation and are always treated a part of a single observation (they are not separable). However, the reference range for the primary observation value is not inherited by the component values and is required when appropriate for each component observation.

                  Инвариантыele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
                  470. Observation.component:breastQuadrant.id
                  Определение

                  Unique id for the element within a resource (for internal references). This may be any string value that does not contain spaces.

                  КороткийUnique id for inter-element referencing
                  Контроль0..1
                  На этот элемент влияют следующие инварианты: ele-1
                  Типstring
                  Модификаторfalse
                  Формат XMLВ формате XML это свойство представлено в качестве атрибута.
                  Summaryfalse
                  472. Observation.component:breastQuadrant.extension
                  Определение

                  May be used to represent additional information that is not part of the basic definition of the element. To make the use of extensions safe and managable, there is a strict set of governance applied to the definition and use of extensions. Though any implementer can define an extension, there is a set of requirements that SHALL be met as part of the definition of the extension.

                  КороткийAdditional content defined by implementations
                  Комментарии

                  There can be no stigma associated with the use of extensions by any application, project, or standard - regardless of the institution or jurisdiction that uses or defines the extensions. The use of extensions is what allows the FHIR specification to retain a core level of simplicity for everyone.

                  Контроль0..*
                  ТипExtension
                  Модификаторfalse
                  Summaryfalse
                  Альтернативные именаextensions, user content
                  Инвариантыele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
                  ext-1: Must have either extensions or value[x], not both (extension.exists() != value.exists())
                  474. Observation.component:breastQuadrant.modifierExtension
                  Определение

                  May be used to represent additional information that is not part of the basic definition of the element and that modifies the understanding of the element in which it is contained and/or the understanding of the containing element's descendants. Usually modifier elements provide negation or qualification. To make the use of extensions safe and managable, there is a strict set of governance applied to the definition and use of extensions. Though any implementer can define an extension, there is a set of requirements that SHALL be met as part of the definition of the extension. Applications processing a resource are required to check for modifier extensions.

                  Modifier extensions SHALL NOT change the meaning of any elements on Resource or DomainResource (including cannot change the meaning of modifierExtension itself).

                  КороткийExtensions that cannot be ignored even if unrecognized
                  Комментарии

                  There can be no stigma associated with the use of extensions by any application, project, or standard - regardless of the institution or jurisdiction that uses or defines the extensions. The use of extensions is what allows the FHIR specification to retain a core level of simplicity for everyone.

                  Контроль0..*
                  ТипExtension
                  Модификаторtrue потому что Modifier extensions are expected to modify the meaning or interpretation of the element that contains them
                  Summarytrue
                  Требования

                  Modifier extensions allow for extensions that cannot be safely ignored to be clearly distinguished from the vast majority of extensions which can be safely ignored. This promotes interoperability by eliminating the need for implementers to prohibit the presence of extensions. For further information, see the definition of modifier extensions.

                  Альтернативные именаextensions, user content, modifiers
                  Инвариантыele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
                  ext-1: Must have either extensions or value[x], not both (extension.exists() != value.exists())
                  476. Observation.component:breastQuadrant.code
                  Определение

                  Describes what was observed. Sometimes this is called the observation "code".

                  КороткийType of component observation (code / type)
                  Комментарии

                  All code-value and component.code-component.value pairs need to be taken into account to correctly understand the meaning of the observation.

                  Контроль1..1
                  На этот элемент влияют следующие инварианты: obs-7
                  ПривязкаКоды СЛЕДУЕТ взять из ObservationCodesVS (0.12.0)
                  (preferred to https://terminology.dhp.uz/fhir/core/ValueSet/observation-codes-vs|0.12.0)
                  ТипCodeableConcept
                  Модификаторfalse
                  Требуется поддержкаtrue
                  Summarytrue
                  Требования

                  Knowing what kind of observation is being made is essential to understanding the observation.

                  Значение шаблона{
                    "coding" : [{
                      "system" : "https://terminology.dhp.uz/fhir/integrations/CodeSystem/screening-specialized-observation-parameter-cs",
                      "code" : "scrn-0073-00015"
                    }]
                  }
                  Инвариантыele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
                  478. Observation.component:breastQuadrant.value[x]
                  Определение

                  The information determined as a result of making the observation, if the information has a simple value.

                  КороткийActual component result
                  Комментарии

                  Used when observation has a set of component observations:

                  • An observation may have both a value (e.g. an Apgar score) and component observations (the observations from which the Apgar score was derived).
                  • If a value is present, the datatype for this element should be determined by the code.
                  • CodeableConcept with just a text would be used instead of a string if the field was usually coded, or if the type associated with the code defines a coded value.
                  • Attachment is used if the observation result value is a binary file such as an image. If the observation result value is derived from the binary file (for example 'X' detected and here is the the proof in this image), the binary file may be directly represented using DocumentReference and referenced by derivedFrom.
                  • If a value is present, the datatype for this element should be determined by the code.
                  • CodeableConcept with just a text would be used instead of a string if the field was usually coded, or if the type associated with the code defines a coded value.
                  • Attachment is used if the observation result value is a binary file such as an image. If the observation result value is derived from the binary file (for example 'X' detected and here is the the proof in this image), the binary file may be directly represented using DocumentReference and referenced by derivedFrom.
                  • The usage of valueReference is restricted to the MolecularSequence resource when used as a definitional resource, not as a patient-specific finding. .
                  • For additional guidance, see the Notes section below.
                  Контроль0..1
                  ПривязкаКоды ДОЛЖНЫ быть взяты из ScreeningUltrasoundBreastQuadrantVS (0.12.1)
                  (required to https://terminology.dhp.uz/fhir/integrations/ValueSet/screening-ultrasound-breast-quadrant-vs|0.12.1)
                  ТипCodeableConcept
                  [x] ЗаметкаСмотретьВыбор типов данныхдля дополнительной информации о том, как использовать [x]
                  Модификаторfalse
                  Требуется поддержкаtrue
                  Summarytrue
                  Требования

                  An observation exists to have a value, though it might not if it is in error, or if it represents a group of observations.

                  Инвариантыele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
                  480. Observation.component:breastQuadrant.dataAbsentReason
                  Определение

                  Provides a reason why the expected value in the element Observation.component.value[x] is missing.

                  КороткийWhy the component result is missing
                  Комментарии

                  "Null" or exceptional values can be represented two ways in FHIR Observations. One way is to simply include them in the value set and represent the exceptions in the value. For example, measurement values for a serology test could be "detected", "not detected", "inconclusive", or "test not done".

                  The alternate way is to use the value element for actual observations and use the explicit dataAbsentReason element to record exceptional values. For example, the dataAbsentReason code "error" could be used when the measurement was not completed. Because of these options, use-case agreements are required to interpret general observations for exceptional values.

                  Контроль0..1
                  ПривязкаЕсли они не подходят, эти коды ДОЛЖНЫ быть взяты из DataAbsentReasonVS (0.12.0)
                  (extensible to https://terminology.dhp.uz/fhir/core/ValueSet/data-absent-reason-vs|0.12.0)
                  ТипCodeableConcept
                  Модификаторfalse
                  Требуется поддержкаfalse
                  Summaryfalse
                  Требования

                  For many results it is necessary to handle exceptional values in measurements.

                  Инвариантыele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
                  482. Observation.component:breastQuadrant.interpretation
                  Определение

                  A categorical assessment of an observation value. For example, high, low, normal.

                  КороткийHigh, low, normal, etc
                  Комментарии

                  Historically used for laboratory results (known as 'abnormal flag' ), its use extends to other use cases where coded interpretations are relevant. Often reported as one or more simple compact codes this element is often placed adjacent to the result value in reports and flow sheets to signal the meaning/normalcy status of the result.

                  Контроль0..*
                  ПривязкаЕсли они не подходят, эти коды ДОЛЖНЫ быть взяты из ObservationInterpretationVS (0.12.0)
                  (extensible to https://terminology.dhp.uz/fhir/core/ValueSet/observation-interpretation-vs|0.12.0)
                  ТипCodeableConcept
                  Модификаторfalse
                  Требуется поддержкаfalse
                  Summaryfalse
                  Требования

                  For some results, particularly numeric results, an interpretation is necessary to fully understand the significance of a result.

                  Альтернативные именаAbnormal Flag
                  Инвариантыele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
                  484. Observation.component:breastQuadrant.referenceRange
                  Определение

                  Guidance on how to interpret the value by comparison to a normal or recommended range.

                  КороткийProvides guide for interpretation of component result
                  Комментарии

                  Most observations only have one generic reference range. Systems MAY choose to restrict to only supplying the relevant reference range based on knowledge about the patient (e.g., specific to the patient's age, gender, weight and other factors), but this might not be possible or appropriate. Whenever more than one reference range is supplied, the differences between them SHOULD be provided in the reference range and/or age properties.

                  Контроль0..*
                  ТипСмотретьttp://hl7.org/fhir/StructureDefinition/Observation#Observation.referenceRange
                  Модификаторfalse
                  Требуется поддержкаfalse
                  Summaryfalse
                  Требования

                  Knowing what values are considered "normal" can help evaluate the significance of a particular result. Need to be able to provide multiple reference ranges for different contexts.

                  Инвариантыele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
                  486. Observation.component:lesionShape
                  Название разрезаlesionShape
                  Определение

                  Some observations have multiple component observations. These component observations are expressed as separate code value pairs that share the same attributes. Examples include systolic and diastolic component observations for blood pressure measurement and multiple component observations for genetics observations.

                  КороткийLesion shape
                  Комментарии

                  For a discussion on the ways Observations can be assembled in groups together see Notes below.

                  Контроль0..1
                  На этот элемент влияют следующие инварианты: obs-7
                  ТипBackboneElement
                  Модификаторfalse
                  Требуется поддержкаtrue
                  Summarytrue
                  Требования

                  Component observations share the same attributes in the Observation resource as the primary observation and are always treated a part of a single observation (they are not separable). However, the reference range for the primary observation value is not inherited by the component values and is required when appropriate for each component observation.

                  Инвариантыele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
                  488. Observation.component:lesionShape.id
                  Определение

                  Unique id for the element within a resource (for internal references). This may be any string value that does not contain spaces.

                  КороткийUnique id for inter-element referencing
                  Контроль0..1
                  На этот элемент влияют следующие инварианты: ele-1
                  Типstring
                  Модификаторfalse
                  Формат XMLВ формате XML это свойство представлено в качестве атрибута.
                  Summaryfalse
                  490. Observation.component:lesionShape.extension
                  Определение

                  May be used to represent additional information that is not part of the basic definition of the element. To make the use of extensions safe and managable, there is a strict set of governance applied to the definition and use of extensions. Though any implementer can define an extension, there is a set of requirements that SHALL be met as part of the definition of the extension.

                  КороткийAdditional content defined by implementations
                  Комментарии

                  There can be no stigma associated with the use of extensions by any application, project, or standard - regardless of the institution or jurisdiction that uses or defines the extensions. The use of extensions is what allows the FHIR specification to retain a core level of simplicity for everyone.

                  Контроль0..*
                  ТипExtension
                  Модификаторfalse
                  Summaryfalse
                  Альтернативные именаextensions, user content
                  Инвариантыele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
                  ext-1: Must have either extensions or value[x], not both (extension.exists() != value.exists())
                  492. Observation.component:lesionShape.modifierExtension
                  Определение

                  May be used to represent additional information that is not part of the basic definition of the element and that modifies the understanding of the element in which it is contained and/or the understanding of the containing element's descendants. Usually modifier elements provide negation or qualification. To make the use of extensions safe and managable, there is a strict set of governance applied to the definition and use of extensions. Though any implementer can define an extension, there is a set of requirements that SHALL be met as part of the definition of the extension. Applications processing a resource are required to check for modifier extensions.

                  Modifier extensions SHALL NOT change the meaning of any elements on Resource or DomainResource (including cannot change the meaning of modifierExtension itself).

                  КороткийExtensions that cannot be ignored even if unrecognized
                  Комментарии

                  There can be no stigma associated with the use of extensions by any application, project, or standard - regardless of the institution or jurisdiction that uses or defines the extensions. The use of extensions is what allows the FHIR specification to retain a core level of simplicity for everyone.

                  Контроль0..*
                  ТипExtension
                  Модификаторtrue потому что Modifier extensions are expected to modify the meaning or interpretation of the element that contains them
                  Summarytrue
                  Требования

                  Modifier extensions allow for extensions that cannot be safely ignored to be clearly distinguished from the vast majority of extensions which can be safely ignored. This promotes interoperability by eliminating the need for implementers to prohibit the presence of extensions. For further information, see the definition of modifier extensions.

                  Альтернативные именаextensions, user content, modifiers
                  Инвариантыele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
                  ext-1: Must have either extensions or value[x], not both (extension.exists() != value.exists())
                  494. Observation.component:lesionShape.code
                  Определение

                  Describes what was observed. Sometimes this is called the observation "code".

                  КороткийType of component observation (code / type)
                  Комментарии

                  All code-value and component.code-component.value pairs need to be taken into account to correctly understand the meaning of the observation.

                  Контроль1..1
                  На этот элемент влияют следующие инварианты: obs-7
                  ПривязкаКоды СЛЕДУЕТ взять из ObservationCodesVS (0.12.0)
                  (preferred to https://terminology.dhp.uz/fhir/core/ValueSet/observation-codes-vs|0.12.0)
                  ТипCodeableConcept
                  Модификаторfalse
                  Требуется поддержкаtrue
                  Summarytrue
                  Требования

                  Knowing what kind of observation is being made is essential to understanding the observation.

                  Значение шаблона{
                    "coding" : [{
                      "system" : "https://terminology.dhp.uz/fhir/integrations/CodeSystem/screening-ultrasound-parameter-cs",
                      "code" : "scrn-0052-00027"
                    }]
                  }
                  Инвариантыele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
                  496. Observation.component:lesionShape.value[x]
                  Определение

                  The information determined as a result of making the observation, if the information has a simple value.

                  КороткийActual component result
                  Комментарии

                  Used when observation has a set of component observations:

                  • An observation may have both a value (e.g. an Apgar score) and component observations (the observations from which the Apgar score was derived).
                  • If a value is present, the datatype for this element should be determined by the code.
                  • CodeableConcept with just a text would be used instead of a string if the field was usually coded, or if the type associated with the code defines a coded value.
                  • Attachment is used if the observation result value is a binary file such as an image. If the observation result value is derived from the binary file (for example 'X' detected and here is the the proof in this image), the binary file may be directly represented using DocumentReference and referenced by derivedFrom.
                  • If a value is present, the datatype for this element should be determined by the code.
                  • CodeableConcept with just a text would be used instead of a string if the field was usually coded, or if the type associated with the code defines a coded value.
                  • Attachment is used if the observation result value is a binary file such as an image. If the observation result value is derived from the binary file (for example 'X' detected and here is the the proof in this image), the binary file may be directly represented using DocumentReference and referenced by derivedFrom.
                  • The usage of valueReference is restricted to the MolecularSequence resource when used as a definitional resource, not as a patient-specific finding. .
                  • For additional guidance, see the Notes section below.
                  Контроль0..1
                  ПривязкаКоды ДОЛЖНЫ быть взяты из ScreeningUltrasoundLesionShapeVS (0.12.1)
                  (required to https://terminology.dhp.uz/fhir/integrations/ValueSet/screening-ultrasound-lesion-shape-vs|0.12.1)
                  ТипCodeableConcept
                  [x] ЗаметкаСмотретьВыбор типов данныхдля дополнительной информации о том, как использовать [x]
                  Модификаторfalse
                  Требуется поддержкаtrue
                  Summarytrue
                  Требования

                  An observation exists to have a value, though it might not if it is in error, or if it represents a group of observations.

                  Инвариантыele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
                  498. Observation.component:lesionShape.dataAbsentReason
                  Определение

                  Provides a reason why the expected value in the element Observation.component.value[x] is missing.

                  КороткийWhy the component result is missing
                  Комментарии

                  "Null" or exceptional values can be represented two ways in FHIR Observations. One way is to simply include them in the value set and represent the exceptions in the value. For example, measurement values for a serology test could be "detected", "not detected", "inconclusive", or "test not done".

                  The alternate way is to use the value element for actual observations and use the explicit dataAbsentReason element to record exceptional values. For example, the dataAbsentReason code "error" could be used when the measurement was not completed. Because of these options, use-case agreements are required to interpret general observations for exceptional values.

                  Контроль0..1
                  ПривязкаЕсли они не подходят, эти коды ДОЛЖНЫ быть взяты из DataAbsentReasonVS (0.12.0)
                  (extensible to https://terminology.dhp.uz/fhir/core/ValueSet/data-absent-reason-vs|0.12.0)
                  ТипCodeableConcept
                  Модификаторfalse
                  Требуется поддержкаfalse
                  Summaryfalse
                  Требования

                  For many results it is necessary to handle exceptional values in measurements.

                  Инвариантыele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
                  500. Observation.component:lesionShape.interpretation
                  Определение

                  A categorical assessment of an observation value. For example, high, low, normal.

                  КороткийHigh, low, normal, etc
                  Комментарии

                  Historically used for laboratory results (known as 'abnormal flag' ), its use extends to other use cases where coded interpretations are relevant. Often reported as one or more simple compact codes this element is often placed adjacent to the result value in reports and flow sheets to signal the meaning/normalcy status of the result.

                  Контроль0..*
                  ПривязкаЕсли они не подходят, эти коды ДОЛЖНЫ быть взяты из ObservationInterpretationVS (0.12.0)
                  (extensible to https://terminology.dhp.uz/fhir/core/ValueSet/observation-interpretation-vs|0.12.0)
                  ТипCodeableConcept
                  Модификаторfalse
                  Требуется поддержкаfalse
                  Summaryfalse
                  Требования

                  For some results, particularly numeric results, an interpretation is necessary to fully understand the significance of a result.

                  Альтернативные именаAbnormal Flag
                  Инвариантыele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
                  502. Observation.component:lesionShape.referenceRange
                  Определение

                  Guidance on how to interpret the value by comparison to a normal or recommended range.

                  КороткийProvides guide for interpretation of component result
                  Комментарии

                  Most observations only have one generic reference range. Systems MAY choose to restrict to only supplying the relevant reference range based on knowledge about the patient (e.g., specific to the patient's age, gender, weight and other factors), but this might not be possible or appropriate. Whenever more than one reference range is supplied, the differences between them SHOULD be provided in the reference range and/or age properties.

                  Контроль0..*
                  ТипСмотретьttp://hl7.org/fhir/StructureDefinition/Observation#Observation.referenceRange
                  Модификаторfalse
                  Требуется поддержкаfalse
                  Summaryfalse
                  Требования

                  Knowing what values are considered "normal" can help evaluate the significance of a particular result. Need to be able to provide multiple reference ranges for different contexts.

                  Инвариантыele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
                  504. Observation.component:lesionOrientation
                  Название разрезаlesionOrientation
                  Определение

                  Some observations have multiple component observations. These component observations are expressed as separate code value pairs that share the same attributes. Examples include systolic and diastolic component observations for blood pressure measurement and multiple component observations for genetics observations.

                  КороткийLesion orientation
                  Комментарии

                  For a discussion on the ways Observations can be assembled in groups together see Notes below.

                  Контроль0..1
                  На этот элемент влияют следующие инварианты: obs-7
                  ТипBackboneElement
                  Модификаторfalse
                  Требуется поддержкаtrue
                  Summarytrue
                  Требования

                  Component observations share the same attributes in the Observation resource as the primary observation and are always treated a part of a single observation (they are not separable). However, the reference range for the primary observation value is not inherited by the component values and is required when appropriate for each component observation.

                  Инвариантыele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
                  506. Observation.component:lesionOrientation.id
                  Определение

                  Unique id for the element within a resource (for internal references). This may be any string value that does not contain spaces.

                  КороткийUnique id for inter-element referencing
                  Контроль0..1
                  На этот элемент влияют следующие инварианты: ele-1
                  Типstring
                  Модификаторfalse
                  Формат XMLВ формате XML это свойство представлено в качестве атрибута.
                  Summaryfalse
                  508. Observation.component:lesionOrientation.extension
                  Определение

                  May be used to represent additional information that is not part of the basic definition of the element. To make the use of extensions safe and managable, there is a strict set of governance applied to the definition and use of extensions. Though any implementer can define an extension, there is a set of requirements that SHALL be met as part of the definition of the extension.

                  КороткийAdditional content defined by implementations
                  Комментарии

                  There can be no stigma associated with the use of extensions by any application, project, or standard - regardless of the institution or jurisdiction that uses or defines the extensions. The use of extensions is what allows the FHIR specification to retain a core level of simplicity for everyone.

                  Контроль0..*
                  ТипExtension
                  Модификаторfalse
                  Summaryfalse
                  Альтернативные именаextensions, user content
                  Инвариантыele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
                  ext-1: Must have either extensions or value[x], not both (extension.exists() != value.exists())
                  510. Observation.component:lesionOrientation.modifierExtension
                  Определение

                  May be used to represent additional information that is not part of the basic definition of the element and that modifies the understanding of the element in which it is contained and/or the understanding of the containing element's descendants. Usually modifier elements provide negation or qualification. To make the use of extensions safe and managable, there is a strict set of governance applied to the definition and use of extensions. Though any implementer can define an extension, there is a set of requirements that SHALL be met as part of the definition of the extension. Applications processing a resource are required to check for modifier extensions.

                  Modifier extensions SHALL NOT change the meaning of any elements on Resource or DomainResource (including cannot change the meaning of modifierExtension itself).

                  КороткийExtensions that cannot be ignored even if unrecognized
                  Комментарии

                  There can be no stigma associated with the use of extensions by any application, project, or standard - regardless of the institution or jurisdiction that uses or defines the extensions. The use of extensions is what allows the FHIR specification to retain a core level of simplicity for everyone.

                  Контроль0..*
                  ТипExtension
                  Модификаторtrue потому что Modifier extensions are expected to modify the meaning or interpretation of the element that contains them
                  Summarytrue
                  Требования

                  Modifier extensions allow for extensions that cannot be safely ignored to be clearly distinguished from the vast majority of extensions which can be safely ignored. This promotes interoperability by eliminating the need for implementers to prohibit the presence of extensions. For further information, see the definition of modifier extensions.

                  Альтернативные именаextensions, user content, modifiers
                  Инвариантыele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
                  ext-1: Must have either extensions or value[x], not both (extension.exists() != value.exists())
                  512. Observation.component:lesionOrientation.code
                  Определение

                  Describes what was observed. Sometimes this is called the observation "code".

                  КороткийType of component observation (code / type)
                  Комментарии

                  All code-value and component.code-component.value pairs need to be taken into account to correctly understand the meaning of the observation.

                  Контроль1..1
                  На этот элемент влияют следующие инварианты: obs-7
                  ПривязкаКоды СЛЕДУЕТ взять из ObservationCodesVS (0.12.0)
                  (preferred to https://terminology.dhp.uz/fhir/core/ValueSet/observation-codes-vs|0.12.0)
                  ТипCodeableConcept
                  Модификаторfalse
                  Требуется поддержкаtrue
                  Summarytrue
                  Требования

                  Knowing what kind of observation is being made is essential to understanding the observation.

                  Значение шаблона{
                    "coding" : [{
                      "system" : "https://terminology.dhp.uz/fhir/integrations/CodeSystem/screening-ultrasound-parameter-cs",
                      "code" : "scrn-0052-00028"
                    }]
                  }
                  Инвариантыele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
                  514. Observation.component:lesionOrientation.value[x]
                  Определение

                  The information determined as a result of making the observation, if the information has a simple value.

                  КороткийActual component result
                  Комментарии

                  Used when observation has a set of component observations:

                  • An observation may have both a value (e.g. an Apgar score) and component observations (the observations from which the Apgar score was derived).
                  • If a value is present, the datatype for this element should be determined by the code.
                  • CodeableConcept with just a text would be used instead of a string if the field was usually coded, or if the type associated with the code defines a coded value.
                  • Attachment is used if the observation result value is a binary file such as an image. If the observation result value is derived from the binary file (for example 'X' detected and here is the the proof in this image), the binary file may be directly represented using DocumentReference and referenced by derivedFrom.
                  • If a value is present, the datatype for this element should be determined by the code.
                  • CodeableConcept with just a text would be used instead of a string if the field was usually coded, or if the type associated with the code defines a coded value.
                  • Attachment is used if the observation result value is a binary file such as an image. If the observation result value is derived from the binary file (for example 'X' detected and here is the the proof in this image), the binary file may be directly represented using DocumentReference and referenced by derivedFrom.
                  • The usage of valueReference is restricted to the MolecularSequence resource when used as a definitional resource, not as a patient-specific finding. .
                  • For additional guidance, see the Notes section below.
                  Контроль0..1
                  ПривязкаКоды ДОЛЖНЫ быть взяты из ScreeningUltrasoundLesionOrientationVS (0.12.1)
                  (required to https://terminology.dhp.uz/fhir/integrations/ValueSet/screening-ultrasound-lesion-orientation-vs|0.12.1)
                  ТипCodeableConcept
                  [x] ЗаметкаСмотретьВыбор типов данныхдля дополнительной информации о том, как использовать [x]
                  Модификаторfalse
                  Требуется поддержкаtrue
                  Summarytrue
                  Требования

                  An observation exists to have a value, though it might not if it is in error, or if it represents a group of observations.

                  Инвариантыele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
                  516. Observation.component:lesionOrientation.dataAbsentReason
                  Определение

                  Provides a reason why the expected value in the element Observation.component.value[x] is missing.

                  КороткийWhy the component result is missing
                  Комментарии

                  "Null" or exceptional values can be represented two ways in FHIR Observations. One way is to simply include them in the value set and represent the exceptions in the value. For example, measurement values for a serology test could be "detected", "not detected", "inconclusive", or "test not done".

                  The alternate way is to use the value element for actual observations and use the explicit dataAbsentReason element to record exceptional values. For example, the dataAbsentReason code "error" could be used when the measurement was not completed. Because of these options, use-case agreements are required to interpret general observations for exceptional values.

                  Контроль0..1
                  ПривязкаЕсли они не подходят, эти коды ДОЛЖНЫ быть взяты из DataAbsentReasonVS (0.12.0)
                  (extensible to https://terminology.dhp.uz/fhir/core/ValueSet/data-absent-reason-vs|0.12.0)
                  ТипCodeableConcept
                  Модификаторfalse
                  Требуется поддержкаfalse
                  Summaryfalse
                  Требования

                  For many results it is necessary to handle exceptional values in measurements.

                  Инвариантыele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
                  518. Observation.component:lesionOrientation.interpretation
                  Определение

                  A categorical assessment of an observation value. For example, high, low, normal.

                  КороткийHigh, low, normal, etc
                  Комментарии

                  Historically used for laboratory results (known as 'abnormal flag' ), its use extends to other use cases where coded interpretations are relevant. Often reported as one or more simple compact codes this element is often placed adjacent to the result value in reports and flow sheets to signal the meaning/normalcy status of the result.

                  Контроль0..*
                  ПривязкаЕсли они не подходят, эти коды ДОЛЖНЫ быть взяты из ObservationInterpretationVS (0.12.0)
                  (extensible to https://terminology.dhp.uz/fhir/core/ValueSet/observation-interpretation-vs|0.12.0)
                  ТипCodeableConcept
                  Модификаторfalse
                  Требуется поддержкаfalse
                  Summaryfalse
                  Требования

                  For some results, particularly numeric results, an interpretation is necessary to fully understand the significance of a result.

                  Альтернативные именаAbnormal Flag
                  Инвариантыele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
                  520. Observation.component:lesionOrientation.referenceRange
                  Определение

                  Guidance on how to interpret the value by comparison to a normal or recommended range.

                  КороткийProvides guide for interpretation of component result
                  Комментарии

                  Most observations only have one generic reference range. Systems MAY choose to restrict to only supplying the relevant reference range based on knowledge about the patient (e.g., specific to the patient's age, gender, weight and other factors), but this might not be possible or appropriate. Whenever more than one reference range is supplied, the differences between them SHOULD be provided in the reference range and/or age properties.

                  Контроль0..*
                  ТипСмотретьttp://hl7.org/fhir/StructureDefinition/Observation#Observation.referenceRange
                  Модификаторfalse
                  Требуется поддержкаfalse
                  Summaryfalse
                  Требования

                  Knowing what values are considered "normal" can help evaluate the significance of a particular result. Need to be able to provide multiple reference ranges for different contexts.

                  Инвариантыele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
                  522. Observation.component:lesionContour
                  Название разрезаlesionContour
                  Определение

                  Some observations have multiple component observations. These component observations are expressed as separate code value pairs that share the same attributes. Examples include systolic and diastolic component observations for blood pressure measurement and multiple component observations for genetics observations.

                  КороткийLesion contour
                  Комментарии

                  For a discussion on the ways Observations can be assembled in groups together see Notes below.

                  Контроль0..1
                  На этот элемент влияют следующие инварианты: obs-7
                  ТипBackboneElement
                  Модификаторfalse
                  Требуется поддержкаtrue
                  Summarytrue
                  Требования

                  Component observations share the same attributes in the Observation resource as the primary observation and are always treated a part of a single observation (they are not separable). However, the reference range for the primary observation value is not inherited by the component values and is required when appropriate for each component observation.

                  Инвариантыele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
                  524. Observation.component:lesionContour.id
                  Определение

                  Unique id for the element within a resource (for internal references). This may be any string value that does not contain spaces.

                  КороткийUnique id for inter-element referencing
                  Контроль0..1
                  На этот элемент влияют следующие инварианты: ele-1
                  Типstring
                  Модификаторfalse
                  Формат XMLВ формате XML это свойство представлено в качестве атрибута.
                  Summaryfalse
                  526. Observation.component:lesionContour.extension
                  Определение

                  May be used to represent additional information that is not part of the basic definition of the element. To make the use of extensions safe and managable, there is a strict set of governance applied to the definition and use of extensions. Though any implementer can define an extension, there is a set of requirements that SHALL be met as part of the definition of the extension.

                  КороткийAdditional content defined by implementations
                  Комментарии

                  There can be no stigma associated with the use of extensions by any application, project, or standard - regardless of the institution or jurisdiction that uses or defines the extensions. The use of extensions is what allows the FHIR specification to retain a core level of simplicity for everyone.

                  Контроль0..*
                  ТипExtension
                  Модификаторfalse
                  Summaryfalse
                  Альтернативные именаextensions, user content
                  Инвариантыele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
                  ext-1: Must have either extensions or value[x], not both (extension.exists() != value.exists())
                  528. Observation.component:lesionContour.modifierExtension
                  Определение

                  May be used to represent additional information that is not part of the basic definition of the element and that modifies the understanding of the element in which it is contained and/or the understanding of the containing element's descendants. Usually modifier elements provide negation or qualification. To make the use of extensions safe and managable, there is a strict set of governance applied to the definition and use of extensions. Though any implementer can define an extension, there is a set of requirements that SHALL be met as part of the definition of the extension. Applications processing a resource are required to check for modifier extensions.

                  Modifier extensions SHALL NOT change the meaning of any elements on Resource or DomainResource (including cannot change the meaning of modifierExtension itself).

                  КороткийExtensions that cannot be ignored even if unrecognized
                  Комментарии

                  There can be no stigma associated with the use of extensions by any application, project, or standard - regardless of the institution or jurisdiction that uses or defines the extensions. The use of extensions is what allows the FHIR specification to retain a core level of simplicity for everyone.

                  Контроль0..*
                  ТипExtension
                  Модификаторtrue потому что Modifier extensions are expected to modify the meaning or interpretation of the element that contains them
                  Summarytrue
                  Требования

                  Modifier extensions allow for extensions that cannot be safely ignored to be clearly distinguished from the vast majority of extensions which can be safely ignored. This promotes interoperability by eliminating the need for implementers to prohibit the presence of extensions. For further information, see the definition of modifier extensions.

                  Альтернативные именаextensions, user content, modifiers
                  Инвариантыele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
                  ext-1: Must have either extensions or value[x], not both (extension.exists() != value.exists())
                  530. Observation.component:lesionContour.code
                  Определение

                  Describes what was observed. Sometimes this is called the observation "code".

                  КороткийType of component observation (code / type)
                  Комментарии

                  All code-value and component.code-component.value pairs need to be taken into account to correctly understand the meaning of the observation.

                  Контроль1..1
                  На этот элемент влияют следующие инварианты: obs-7
                  ПривязкаКоды СЛЕДУЕТ взять из ObservationCodesVS (0.12.0)
                  (preferred to https://terminology.dhp.uz/fhir/core/ValueSet/observation-codes-vs|0.12.0)
                  ТипCodeableConcept
                  Модификаторfalse
                  Требуется поддержкаtrue
                  Summarytrue
                  Требования

                  Knowing what kind of observation is being made is essential to understanding the observation.

                  Значение шаблона{
                    "coding" : [{
                      "system" : "https://terminology.dhp.uz/fhir/integrations/CodeSystem/screening-ultrasound-parameter-cs",
                      "code" : "scrn-0052-00029"
                    }]
                  }
                  Инвариантыele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
                  532. Observation.component:lesionContour.value[x]
                  Определение

                  The information determined as a result of making the observation, if the information has a simple value.

                  КороткийActual component result
                  Комментарии

                  Used when observation has a set of component observations:

                  • An observation may have both a value (e.g. an Apgar score) and component observations (the observations from which the Apgar score was derived).
                  • If a value is present, the datatype for this element should be determined by the code.
                  • CodeableConcept with just a text would be used instead of a string if the field was usually coded, or if the type associated with the code defines a coded value.
                  • Attachment is used if the observation result value is a binary file such as an image. If the observation result value is derived from the binary file (for example 'X' detected and here is the the proof in this image), the binary file may be directly represented using DocumentReference and referenced by derivedFrom.
                  • If a value is present, the datatype for this element should be determined by the code.
                  • CodeableConcept with just a text would be used instead of a string if the field was usually coded, or if the type associated with the code defines a coded value.
                  • Attachment is used if the observation result value is a binary file such as an image. If the observation result value is derived from the binary file (for example 'X' detected and here is the the proof in this image), the binary file may be directly represented using DocumentReference and referenced by derivedFrom.
                  • The usage of valueReference is restricted to the MolecularSequence resource when used as a definitional resource, not as a patient-specific finding. .
                  • For additional guidance, see the Notes section below.
                  Контроль0..1
                  ПривязкаКоды ДОЛЖНЫ быть взяты из ScreeningUltrasoundLesionContourVS (0.12.1)
                  (required to https://terminology.dhp.uz/fhir/integrations/ValueSet/screening-ultrasound-lesion-contour-vs|0.12.1)
                  ТипCodeableConcept
                  [x] ЗаметкаСмотретьВыбор типов данныхдля дополнительной информации о том, как использовать [x]
                  Модификаторfalse
                  Требуется поддержкаtrue
                  Summarytrue
                  Требования

                  An observation exists to have a value, though it might not if it is in error, or if it represents a group of observations.

                  Инвариантыele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
                  534. Observation.component:lesionContour.dataAbsentReason
                  Определение

                  Provides a reason why the expected value in the element Observation.component.value[x] is missing.

                  КороткийWhy the component result is missing
                  Комментарии

                  "Null" or exceptional values can be represented two ways in FHIR Observations. One way is to simply include them in the value set and represent the exceptions in the value. For example, measurement values for a serology test could be "detected", "not detected", "inconclusive", or "test not done".

                  The alternate way is to use the value element for actual observations and use the explicit dataAbsentReason element to record exceptional values. For example, the dataAbsentReason code "error" could be used when the measurement was not completed. Because of these options, use-case agreements are required to interpret general observations for exceptional values.

                  Контроль0..1
                  ПривязкаЕсли они не подходят, эти коды ДОЛЖНЫ быть взяты из DataAbsentReasonVS (0.12.0)
                  (extensible to https://terminology.dhp.uz/fhir/core/ValueSet/data-absent-reason-vs|0.12.0)
                  ТипCodeableConcept
                  Модификаторfalse
                  Требуется поддержкаfalse
                  Summaryfalse
                  Требования

                  For many results it is necessary to handle exceptional values in measurements.

                  Инвариантыele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
                  536. Observation.component:lesionContour.interpretation
                  Определение

                  A categorical assessment of an observation value. For example, high, low, normal.

                  КороткийHigh, low, normal, etc
                  Комментарии

                  Historically used for laboratory results (known as 'abnormal flag' ), its use extends to other use cases where coded interpretations are relevant. Often reported as one or more simple compact codes this element is often placed adjacent to the result value in reports and flow sheets to signal the meaning/normalcy status of the result.

                  Контроль0..*
                  ПривязкаЕсли они не подходят, эти коды ДОЛЖНЫ быть взяты из ObservationInterpretationVS (0.12.0)
                  (extensible to https://terminology.dhp.uz/fhir/core/ValueSet/observation-interpretation-vs|0.12.0)
                  ТипCodeableConcept
                  Модификаторfalse
                  Требуется поддержкаfalse
                  Summaryfalse
                  Требования

                  For some results, particularly numeric results, an interpretation is necessary to fully understand the significance of a result.

                  Альтернативные именаAbnormal Flag
                  Инвариантыele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
                  538. Observation.component:lesionContour.referenceRange
                  Определение

                  Guidance on how to interpret the value by comparison to a normal or recommended range.

                  КороткийProvides guide for interpretation of component result
                  Комментарии

                  Most observations only have one generic reference range. Systems MAY choose to restrict to only supplying the relevant reference range based on knowledge about the patient (e.g., specific to the patient's age, gender, weight and other factors), but this might not be possible or appropriate. Whenever more than one reference range is supplied, the differences between them SHOULD be provided in the reference range and/or age properties.

                  Контроль0..*
                  ТипСмотретьttp://hl7.org/fhir/StructureDefinition/Observation#Observation.referenceRange
                  Модификаторfalse
                  Требуется поддержкаfalse
                  Summaryfalse
                  Требования

                  Knowing what values are considered "normal" can help evaluate the significance of a particular result. Need to be able to provide multiple reference ranges for different contexts.

                  Инвариантыele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
                  540. Observation.component:lesionEchogenicity
                  Название разрезаlesionEchogenicity
                  Определение

                  Some observations have multiple component observations. These component observations are expressed as separate code value pairs that share the same attributes. Examples include systolic and diastolic component observations for blood pressure measurement and multiple component observations for genetics observations.

                  КороткийLesion echogenicity
                  Комментарии

                  For a discussion on the ways Observations can be assembled in groups together see Notes below.

                  Контроль0..1
                  На этот элемент влияют следующие инварианты: obs-7
                  ТипBackboneElement
                  Модификаторfalse
                  Требуется поддержкаtrue
                  Summarytrue
                  Требования

                  Component observations share the same attributes in the Observation resource as the primary observation and are always treated a part of a single observation (they are not separable). However, the reference range for the primary observation value is not inherited by the component values and is required when appropriate for each component observation.

                  Инвариантыele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
                  542. Observation.component:lesionEchogenicity.id
                  Определение

                  Unique id for the element within a resource (for internal references). This may be any string value that does not contain spaces.

                  КороткийUnique id for inter-element referencing
                  Контроль0..1
                  На этот элемент влияют следующие инварианты: ele-1
                  Типstring
                  Модификаторfalse
                  Формат XMLВ формате XML это свойство представлено в качестве атрибута.
                  Summaryfalse
                  544. Observation.component:lesionEchogenicity.extension
                  Определение

                  May be used to represent additional information that is not part of the basic definition of the element. To make the use of extensions safe and managable, there is a strict set of governance applied to the definition and use of extensions. Though any implementer can define an extension, there is a set of requirements that SHALL be met as part of the definition of the extension.

                  КороткийAdditional content defined by implementations
                  Комментарии

                  There can be no stigma associated with the use of extensions by any application, project, or standard - regardless of the institution or jurisdiction that uses or defines the extensions. The use of extensions is what allows the FHIR specification to retain a core level of simplicity for everyone.

                  Контроль0..*
                  ТипExtension
                  Модификаторfalse
                  Summaryfalse
                  Альтернативные именаextensions, user content
                  Инвариантыele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
                  ext-1: Must have either extensions or value[x], not both (extension.exists() != value.exists())
                  546. Observation.component:lesionEchogenicity.modifierExtension
                  Определение

                  May be used to represent additional information that is not part of the basic definition of the element and that modifies the understanding of the element in which it is contained and/or the understanding of the containing element's descendants. Usually modifier elements provide negation or qualification. To make the use of extensions safe and managable, there is a strict set of governance applied to the definition and use of extensions. Though any implementer can define an extension, there is a set of requirements that SHALL be met as part of the definition of the extension. Applications processing a resource are required to check for modifier extensions.

                  Modifier extensions SHALL NOT change the meaning of any elements on Resource or DomainResource (including cannot change the meaning of modifierExtension itself).

                  КороткийExtensions that cannot be ignored even if unrecognized
                  Комментарии

                  There can be no stigma associated with the use of extensions by any application, project, or standard - regardless of the institution or jurisdiction that uses or defines the extensions. The use of extensions is what allows the FHIR specification to retain a core level of simplicity for everyone.

                  Контроль0..*
                  ТипExtension
                  Модификаторtrue потому что Modifier extensions are expected to modify the meaning or interpretation of the element that contains them
                  Summarytrue
                  Требования

                  Modifier extensions allow for extensions that cannot be safely ignored to be clearly distinguished from the vast majority of extensions which can be safely ignored. This promotes interoperability by eliminating the need for implementers to prohibit the presence of extensions. For further information, see the definition of modifier extensions.

                  Альтернативные именаextensions, user content, modifiers
                  Инвариантыele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
                  ext-1: Must have either extensions or value[x], not both (extension.exists() != value.exists())
                  548. Observation.component:lesionEchogenicity.code
                  Определение

                  Describes what was observed. Sometimes this is called the observation "code".

                  КороткийType of component observation (code / type)
                  Комментарии

                  All code-value and component.code-component.value pairs need to be taken into account to correctly understand the meaning of the observation.

                  Контроль1..1
                  На этот элемент влияют следующие инварианты: obs-7
                  ПривязкаКоды СЛЕДУЕТ взять из ObservationCodesVS (0.12.0)
                  (preferred to https://terminology.dhp.uz/fhir/core/ValueSet/observation-codes-vs|0.12.0)
                  ТипCodeableConcept
                  Модификаторfalse
                  Требуется поддержкаtrue
                  Summarytrue
                  Требования

                  Knowing what kind of observation is being made is essential to understanding the observation.

                  Значение шаблона{
                    "coding" : [{
                      "system" : "https://terminology.dhp.uz/fhir/integrations/CodeSystem/screening-ultrasound-parameter-cs",
                      "code" : "scrn-0052-00030"
                    }]
                  }
                  Инвариантыele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
                  550. Observation.component:lesionEchogenicity.value[x]
                  Определение

                  The information determined as a result of making the observation, if the information has a simple value.

                  КороткийActual component result
                  Комментарии

                  Used when observation has a set of component observations:

                  • An observation may have both a value (e.g. an Apgar score) and component observations (the observations from which the Apgar score was derived).
                  • If a value is present, the datatype for this element should be determined by the code.
                  • CodeableConcept with just a text would be used instead of a string if the field was usually coded, or if the type associated with the code defines a coded value.
                  • Attachment is used if the observation result value is a binary file such as an image. If the observation result value is derived from the binary file (for example 'X' detected and here is the the proof in this image), the binary file may be directly represented using DocumentReference and referenced by derivedFrom.
                  • If a value is present, the datatype for this element should be determined by the code.
                  • CodeableConcept with just a text would be used instead of a string if the field was usually coded, or if the type associated with the code defines a coded value.
                  • Attachment is used if the observation result value is a binary file such as an image. If the observation result value is derived from the binary file (for example 'X' detected and here is the the proof in this image), the binary file may be directly represented using DocumentReference and referenced by derivedFrom.
                  • The usage of valueReference is restricted to the MolecularSequence resource when used as a definitional resource, not as a patient-specific finding. .
                  • For additional guidance, see the Notes section below.
                  Контроль0..1
                  ПривязкаКоды ДОЛЖНЫ быть взяты из ScreeningUltrasoundLesionEchogenicityVS (0.12.1)
                  (required to https://terminology.dhp.uz/fhir/integrations/ValueSet/screening-ultrasound-lesion-echogenicity-vs|0.12.1)
                  ТипCodeableConcept
                  [x] ЗаметкаСмотретьВыбор типов данныхдля дополнительной информации о том, как использовать [x]
                  Модификаторfalse
                  Требуется поддержкаtrue
                  Summarytrue
                  Требования

                  An observation exists to have a value, though it might not if it is in error, or if it represents a group of observations.

                  Инвариантыele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
                  552. Observation.component:lesionEchogenicity.dataAbsentReason
                  Определение

                  Provides a reason why the expected value in the element Observation.component.value[x] is missing.

                  КороткийWhy the component result is missing
                  Комментарии

                  "Null" or exceptional values can be represented two ways in FHIR Observations. One way is to simply include them in the value set and represent the exceptions in the value. For example, measurement values for a serology test could be "detected", "not detected", "inconclusive", or "test not done".

                  The alternate way is to use the value element for actual observations and use the explicit dataAbsentReason element to record exceptional values. For example, the dataAbsentReason code "error" could be used when the measurement was not completed. Because of these options, use-case agreements are required to interpret general observations for exceptional values.

                  Контроль0..1
                  ПривязкаЕсли они не подходят, эти коды ДОЛЖНЫ быть взяты из DataAbsentReasonVS (0.12.0)
                  (extensible to https://terminology.dhp.uz/fhir/core/ValueSet/data-absent-reason-vs|0.12.0)
                  ТипCodeableConcept
                  Модификаторfalse
                  Требуется поддержкаfalse
                  Summaryfalse
                  Требования

                  For many results it is necessary to handle exceptional values in measurements.

                  Инвариантыele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
                  554. Observation.component:lesionEchogenicity.interpretation
                  Определение

                  A categorical assessment of an observation value. For example, high, low, normal.

                  КороткийHigh, low, normal, etc
                  Комментарии

                  Historically used for laboratory results (known as 'abnormal flag' ), its use extends to other use cases where coded interpretations are relevant. Often reported as one or more simple compact codes this element is often placed adjacent to the result value in reports and flow sheets to signal the meaning/normalcy status of the result.

                  Контроль0..*
                  ПривязкаЕсли они не подходят, эти коды ДОЛЖНЫ быть взяты из ObservationInterpretationVS (0.12.0)
                  (extensible to https://terminology.dhp.uz/fhir/core/ValueSet/observation-interpretation-vs|0.12.0)
                  ТипCodeableConcept
                  Модификаторfalse
                  Требуется поддержкаfalse
                  Summaryfalse
                  Требования

                  For some results, particularly numeric results, an interpretation is necessary to fully understand the significance of a result.

                  Альтернативные именаAbnormal Flag
                  Инвариантыele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
                  556. Observation.component:lesionEchogenicity.referenceRange
                  Определение

                  Guidance on how to interpret the value by comparison to a normal or recommended range.

                  КороткийProvides guide for interpretation of component result
                  Комментарии

                  Most observations only have one generic reference range. Systems MAY choose to restrict to only supplying the relevant reference range based on knowledge about the patient (e.g., specific to the patient's age, gender, weight and other factors), but this might not be possible or appropriate. Whenever more than one reference range is supplied, the differences between them SHOULD be provided in the reference range and/or age properties.

                  Контроль0..*
                  ТипСмотретьttp://hl7.org/fhir/StructureDefinition/Observation#Observation.referenceRange
                  Модификаторfalse
                  Требуется поддержкаfalse
                  Summaryfalse
                  Требования

                  Knowing what values are considered "normal" can help evaluate the significance of a particular result. Need to be able to provide multiple reference ranges for different contexts.

                  Инвариантыele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
                  558. Observation.component:lesionAcousticEffect
                  Название разрезаlesionAcousticEffect
                  Определение

                  Some observations have multiple component observations. These component observations are expressed as separate code value pairs that share the same attributes. Examples include systolic and diastolic component observations for blood pressure measurement and multiple component observations for genetics observations.

                  КороткийLesion acoustic effect
                  Комментарии

                  For a discussion on the ways Observations can be assembled in groups together see Notes below.

                  Контроль0..1
                  На этот элемент влияют следующие инварианты: obs-7
                  ТипBackboneElement
                  Модификаторfalse
                  Требуется поддержкаtrue
                  Summarytrue
                  Требования

                  Component observations share the same attributes in the Observation resource as the primary observation and are always treated a part of a single observation (they are not separable). However, the reference range for the primary observation value is not inherited by the component values and is required when appropriate for each component observation.

                  Инвариантыele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
                  560. Observation.component:lesionAcousticEffect.id
                  Определение

                  Unique id for the element within a resource (for internal references). This may be any string value that does not contain spaces.

                  КороткийUnique id for inter-element referencing
                  Контроль0..1
                  На этот элемент влияют следующие инварианты: ele-1
                  Типstring
                  Модификаторfalse
                  Формат XMLВ формате XML это свойство представлено в качестве атрибута.
                  Summaryfalse
                  562. Observation.component:lesionAcousticEffect.extension
                  Определение

                  May be used to represent additional information that is not part of the basic definition of the element. To make the use of extensions safe and managable, there is a strict set of governance applied to the definition and use of extensions. Though any implementer can define an extension, there is a set of requirements that SHALL be met as part of the definition of the extension.

                  КороткийAdditional content defined by implementations
                  Комментарии

                  There can be no stigma associated with the use of extensions by any application, project, or standard - regardless of the institution or jurisdiction that uses or defines the extensions. The use of extensions is what allows the FHIR specification to retain a core level of simplicity for everyone.

                  Контроль0..*
                  ТипExtension
                  Модификаторfalse
                  Summaryfalse
                  Альтернативные именаextensions, user content
                  Инвариантыele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
                  ext-1: Must have either extensions or value[x], not both (extension.exists() != value.exists())
                  564. Observation.component:lesionAcousticEffect.modifierExtension
                  Определение

                  May be used to represent additional information that is not part of the basic definition of the element and that modifies the understanding of the element in which it is contained and/or the understanding of the containing element's descendants. Usually modifier elements provide negation or qualification. To make the use of extensions safe and managable, there is a strict set of governance applied to the definition and use of extensions. Though any implementer can define an extension, there is a set of requirements that SHALL be met as part of the definition of the extension. Applications processing a resource are required to check for modifier extensions.

                  Modifier extensions SHALL NOT change the meaning of any elements on Resource or DomainResource (including cannot change the meaning of modifierExtension itself).

                  КороткийExtensions that cannot be ignored even if unrecognized
                  Комментарии

                  There can be no stigma associated with the use of extensions by any application, project, or standard - regardless of the institution or jurisdiction that uses or defines the extensions. The use of extensions is what allows the FHIR specification to retain a core level of simplicity for everyone.

                  Контроль0..*
                  ТипExtension
                  Модификаторtrue потому что Modifier extensions are expected to modify the meaning or interpretation of the element that contains them
                  Summarytrue
                  Требования

                  Modifier extensions allow for extensions that cannot be safely ignored to be clearly distinguished from the vast majority of extensions which can be safely ignored. This promotes interoperability by eliminating the need for implementers to prohibit the presence of extensions. For further information, see the definition of modifier extensions.

                  Альтернативные именаextensions, user content, modifiers
                  Инвариантыele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
                  ext-1: Must have either extensions or value[x], not both (extension.exists() != value.exists())
                  566. Observation.component:lesionAcousticEffect.code
                  Определение

                  Describes what was observed. Sometimes this is called the observation "code".

                  КороткийType of component observation (code / type)
                  Комментарии

                  All code-value and component.code-component.value pairs need to be taken into account to correctly understand the meaning of the observation.

                  Контроль1..1
                  На этот элемент влияют следующие инварианты: obs-7
                  ПривязкаКоды СЛЕДУЕТ взять из ObservationCodesVS (0.12.0)
                  (preferred to https://terminology.dhp.uz/fhir/core/ValueSet/observation-codes-vs|0.12.0)
                  ТипCodeableConcept
                  Модификаторfalse
                  Требуется поддержкаtrue
                  Summarytrue
                  Требования

                  Knowing what kind of observation is being made is essential to understanding the observation.

                  Значение шаблона{
                    "coding" : [{
                      "system" : "https://terminology.dhp.uz/fhir/integrations/CodeSystem/screening-ultrasound-parameter-cs",
                      "code" : "scrn-0052-00036"
                    }]
                  }
                  Инвариантыele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
                  568. Observation.component:lesionAcousticEffect.value[x]
                  Определение

                  The information determined as a result of making the observation, if the information has a simple value.

                  КороткийActual component result
                  Комментарии

                  Used when observation has a set of component observations:

                  • An observation may have both a value (e.g. an Apgar score) and component observations (the observations from which the Apgar score was derived).
                  • If a value is present, the datatype for this element should be determined by the code.
                  • CodeableConcept with just a text would be used instead of a string if the field was usually coded, or if the type associated with the code defines a coded value.
                  • Attachment is used if the observation result value is a binary file such as an image. If the observation result value is derived from the binary file (for example 'X' detected and here is the the proof in this image), the binary file may be directly represented using DocumentReference and referenced by derivedFrom.
                  • If a value is present, the datatype for this element should be determined by the code.
                  • CodeableConcept with just a text would be used instead of a string if the field was usually coded, or if the type associated with the code defines a coded value.
                  • Attachment is used if the observation result value is a binary file such as an image. If the observation result value is derived from the binary file (for example 'X' detected and here is the the proof in this image), the binary file may be directly represented using DocumentReference and referenced by derivedFrom.
                  • The usage of valueReference is restricted to the MolecularSequence resource when used as a definitional resource, not as a patient-specific finding. .
                  • For additional guidance, see the Notes section below.
                  Контроль0..1
                  ПривязкаКоды ДОЛЖНЫ быть взяты из ScreeningUltrasoundLesionAcousticEffectVS (0.12.1)
                  (required to https://terminology.dhp.uz/fhir/integrations/ValueSet/screening-ultrasound-lesion-acoustic-effect-vs|0.12.1)
                  ТипCodeableConcept
                  [x] ЗаметкаСмотретьВыбор типов данныхдля дополнительной информации о том, как использовать [x]
                  Модификаторfalse
                  Требуется поддержкаtrue
                  Summarytrue
                  Требования

                  An observation exists to have a value, though it might not if it is in error, or if it represents a group of observations.

                  Инвариантыele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
                  570. Observation.component:lesionAcousticEffect.dataAbsentReason
                  Определение

                  Provides a reason why the expected value in the element Observation.component.value[x] is missing.

                  КороткийWhy the component result is missing
                  Комментарии

                  "Null" or exceptional values can be represented two ways in FHIR Observations. One way is to simply include them in the value set and represent the exceptions in the value. For example, measurement values for a serology test could be "detected", "not detected", "inconclusive", or "test not done".

                  The alternate way is to use the value element for actual observations and use the explicit dataAbsentReason element to record exceptional values. For example, the dataAbsentReason code "error" could be used when the measurement was not completed. Because of these options, use-case agreements are required to interpret general observations for exceptional values.

                  Контроль0..1
                  ПривязкаЕсли они не подходят, эти коды ДОЛЖНЫ быть взяты из DataAbsentReasonVS (0.12.0)
                  (extensible to https://terminology.dhp.uz/fhir/core/ValueSet/data-absent-reason-vs|0.12.0)
                  ТипCodeableConcept
                  Модификаторfalse
                  Требуется поддержкаfalse
                  Summaryfalse
                  Требования

                  For many results it is necessary to handle exceptional values in measurements.

                  Инвариантыele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
                  572. Observation.component:lesionAcousticEffect.interpretation
                  Определение

                  A categorical assessment of an observation value. For example, high, low, normal.

                  КороткийHigh, low, normal, etc
                  Комментарии

                  Historically used for laboratory results (known as 'abnormal flag' ), its use extends to other use cases where coded interpretations are relevant. Often reported as one or more simple compact codes this element is often placed adjacent to the result value in reports and flow sheets to signal the meaning/normalcy status of the result.

                  Контроль0..*
                  ПривязкаЕсли они не подходят, эти коды ДОЛЖНЫ быть взяты из ObservationInterpretationVS (0.12.0)
                  (extensible to https://terminology.dhp.uz/fhir/core/ValueSet/observation-interpretation-vs|0.12.0)
                  ТипCodeableConcept
                  Модификаторfalse
                  Требуется поддержкаfalse
                  Summaryfalse
                  Требования

                  For some results, particularly numeric results, an interpretation is necessary to fully understand the significance of a result.

                  Альтернативные именаAbnormal Flag
                  Инвариантыele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
                  574. Observation.component:lesionAcousticEffect.referenceRange
                  Определение

                  Guidance on how to interpret the value by comparison to a normal or recommended range.

                  КороткийProvides guide for interpretation of component result
                  Комментарии

                  Most observations only have one generic reference range. Systems MAY choose to restrict to only supplying the relevant reference range based on knowledge about the patient (e.g., specific to the patient's age, gender, weight and other factors), but this might not be possible or appropriate. Whenever more than one reference range is supplied, the differences between them SHOULD be provided in the reference range and/or age properties.

                  Контроль0..*
                  ТипСмотретьttp://hl7.org/fhir/StructureDefinition/Observation#Observation.referenceRange
                  Модификаторfalse
                  Требуется поддержкаfalse
                  Summaryfalse
                  Требования

                  Knowing what values are considered "normal" can help evaluate the significance of a particular result. Need to be able to provide multiple reference ranges for different contexts.

                  Инвариантыele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
                  576. Observation.component:lesionVascularization
                  Название разрезаlesionVascularization
                  Определение

                  Some observations have multiple component observations. These component observations are expressed as separate code value pairs that share the same attributes. Examples include systolic and diastolic component observations for blood pressure measurement and multiple component observations for genetics observations.

                  КороткийLesion vascularization
                  Комментарии

                  For a discussion on the ways Observations can be assembled in groups together see Notes below.

                  Контроль0..1
                  На этот элемент влияют следующие инварианты: obs-7
                  ТипBackboneElement
                  Модификаторfalse
                  Требуется поддержкаtrue
                  Summarytrue
                  Требования

                  Component observations share the same attributes in the Observation resource as the primary observation and are always treated a part of a single observation (they are not separable). However, the reference range for the primary observation value is not inherited by the component values and is required when appropriate for each component observation.

                  Инвариантыele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
                  578. Observation.component:lesionVascularization.id
                  Определение

                  Unique id for the element within a resource (for internal references). This may be any string value that does not contain spaces.

                  КороткийUnique id for inter-element referencing
                  Контроль0..1
                  На этот элемент влияют следующие инварианты: ele-1
                  Типstring
                  Модификаторfalse
                  Формат XMLВ формате XML это свойство представлено в качестве атрибута.
                  Summaryfalse
                  580. Observation.component:lesionVascularization.extension
                  Определение

                  May be used to represent additional information that is not part of the basic definition of the element. To make the use of extensions safe and managable, there is a strict set of governance applied to the definition and use of extensions. Though any implementer can define an extension, there is a set of requirements that SHALL be met as part of the definition of the extension.

                  КороткийAdditional content defined by implementations
                  Комментарии

                  There can be no stigma associated with the use of extensions by any application, project, or standard - regardless of the institution or jurisdiction that uses or defines the extensions. The use of extensions is what allows the FHIR specification to retain a core level of simplicity for everyone.

                  Контроль0..*
                  ТипExtension
                  Модификаторfalse
                  Summaryfalse
                  Альтернативные именаextensions, user content
                  Инвариантыele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
                  ext-1: Must have either extensions or value[x], not both (extension.exists() != value.exists())
                  582. Observation.component:lesionVascularization.modifierExtension
                  Определение

                  May be used to represent additional information that is not part of the basic definition of the element and that modifies the understanding of the element in which it is contained and/or the understanding of the containing element's descendants. Usually modifier elements provide negation or qualification. To make the use of extensions safe and managable, there is a strict set of governance applied to the definition and use of extensions. Though any implementer can define an extension, there is a set of requirements that SHALL be met as part of the definition of the extension. Applications processing a resource are required to check for modifier extensions.

                  Modifier extensions SHALL NOT change the meaning of any elements on Resource or DomainResource (including cannot change the meaning of modifierExtension itself).

                  КороткийExtensions that cannot be ignored even if unrecognized
                  Комментарии

                  There can be no stigma associated with the use of extensions by any application, project, or standard - regardless of the institution or jurisdiction that uses or defines the extensions. The use of extensions is what allows the FHIR specification to retain a core level of simplicity for everyone.

                  Контроль0..*
                  ТипExtension
                  Модификаторtrue потому что Modifier extensions are expected to modify the meaning or interpretation of the element that contains them
                  Summarytrue
                  Требования

                  Modifier extensions allow for extensions that cannot be safely ignored to be clearly distinguished from the vast majority of extensions which can be safely ignored. This promotes interoperability by eliminating the need for implementers to prohibit the presence of extensions. For further information, see the definition of modifier extensions.

                  Альтернативные именаextensions, user content, modifiers
                  Инвариантыele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
                  ext-1: Must have either extensions or value[x], not both (extension.exists() != value.exists())
                  584. Observation.component:lesionVascularization.code
                  Определение

                  Describes what was observed. Sometimes this is called the observation "code".

                  КороткийType of component observation (code / type)
                  Комментарии

                  All code-value and component.code-component.value pairs need to be taken into account to correctly understand the meaning of the observation.

                  Контроль1..1
                  На этот элемент влияют следующие инварианты: obs-7
                  ПривязкаКоды СЛЕДУЕТ взять из ObservationCodesVS (0.12.0)
                  (preferred to https://terminology.dhp.uz/fhir/core/ValueSet/observation-codes-vs|0.12.0)
                  ТипCodeableConcept
                  Модификаторfalse
                  Требуется поддержкаtrue
                  Summarytrue
                  Требования

                  Knowing what kind of observation is being made is essential to understanding the observation.

                  Значение шаблона{
                    "coding" : [{
                      "system" : "https://terminology.dhp.uz/fhir/integrations/CodeSystem/screening-ultrasound-parameter-cs",
                      "code" : "scrn-0052-00037"
                    }]
                  }
                  Инвариантыele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
                  586. Observation.component:lesionVascularization.value[x]
                  Определение

                  The information determined as a result of making the observation, if the information has a simple value.

                  КороткийActual component result
                  Комментарии

                  Used when observation has a set of component observations:

                  • An observation may have both a value (e.g. an Apgar score) and component observations (the observations from which the Apgar score was derived).
                  • If a value is present, the datatype for this element should be determined by the code.
                  • CodeableConcept with just a text would be used instead of a string if the field was usually coded, or if the type associated with the code defines a coded value.
                  • Attachment is used if the observation result value is a binary file such as an image. If the observation result value is derived from the binary file (for example 'X' detected and here is the the proof in this image), the binary file may be directly represented using DocumentReference and referenced by derivedFrom.
                  • If a value is present, the datatype for this element should be determined by the code.
                  • CodeableConcept with just a text would be used instead of a string if the field was usually coded, or if the type associated with the code defines a coded value.
                  • Attachment is used if the observation result value is a binary file such as an image. If the observation result value is derived from the binary file (for example 'X' detected and here is the the proof in this image), the binary file may be directly represented using DocumentReference and referenced by derivedFrom.
                  • The usage of valueReference is restricted to the MolecularSequence resource when used as a definitional resource, not as a patient-specific finding. .
                  • For additional guidance, see the Notes section below.
                  Контроль0..1
                  ПривязкаКоды ДОЛЖНЫ быть взяты из ScreeningUltrasoundLesionVascularizationVS (0.12.1)
                  (required to https://terminology.dhp.uz/fhir/integrations/ValueSet/screening-ultrasound-lesion-vascularization-vs|0.12.1)
                  ТипCodeableConcept
                  [x] ЗаметкаСмотретьВыбор типов данныхдля дополнительной информации о том, как использовать [x]
                  Модификаторfalse
                  Требуется поддержкаtrue
                  Summarytrue
                  Требования

                  An observation exists to have a value, though it might not if it is in error, or if it represents a group of observations.

                  Инвариантыele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
                  588. Observation.component:lesionVascularization.dataAbsentReason
                  Определение

                  Provides a reason why the expected value in the element Observation.component.value[x] is missing.

                  КороткийWhy the component result is missing
                  Комментарии

                  "Null" or exceptional values can be represented two ways in FHIR Observations. One way is to simply include them in the value set and represent the exceptions in the value. For example, measurement values for a serology test could be "detected", "not detected", "inconclusive", or "test not done".

                  The alternate way is to use the value element for actual observations and use the explicit dataAbsentReason element to record exceptional values. For example, the dataAbsentReason code "error" could be used when the measurement was not completed. Because of these options, use-case agreements are required to interpret general observations for exceptional values.

                  Контроль0..1
                  ПривязкаЕсли они не подходят, эти коды ДОЛЖНЫ быть взяты из DataAbsentReasonVS (0.12.0)
                  (extensible to https://terminology.dhp.uz/fhir/core/ValueSet/data-absent-reason-vs|0.12.0)
                  ТипCodeableConcept
                  Модификаторfalse
                  Требуется поддержкаfalse
                  Summaryfalse
                  Требования

                  For many results it is necessary to handle exceptional values in measurements.

                  Инвариантыele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
                  590. Observation.component:lesionVascularization.interpretation
                  Определение

                  A categorical assessment of an observation value. For example, high, low, normal.

                  КороткийHigh, low, normal, etc
                  Комментарии

                  Historically used for laboratory results (known as 'abnormal flag' ), its use extends to other use cases where coded interpretations are relevant. Often reported as one or more simple compact codes this element is often placed adjacent to the result value in reports and flow sheets to signal the meaning/normalcy status of the result.

                  Контроль0..*
                  ПривязкаЕсли они не подходят, эти коды ДОЛЖНЫ быть взяты из ObservationInterpretationVS (0.12.0)
                  (extensible to https://terminology.dhp.uz/fhir/core/ValueSet/observation-interpretation-vs|0.12.0)
                  ТипCodeableConcept
                  Модификаторfalse
                  Требуется поддержкаfalse
                  Summaryfalse
                  Требования

                  For some results, particularly numeric results, an interpretation is necessary to fully understand the significance of a result.

                  Альтернативные именаAbnormal Flag
                  Инвариантыele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
                  592. Observation.component:lesionVascularization.referenceRange
                  Определение

                  Guidance on how to interpret the value by comparison to a normal or recommended range.

                  КороткийProvides guide for interpretation of component result
                  Комментарии

                  Most observations only have one generic reference range. Systems MAY choose to restrict to only supplying the relevant reference range based on knowledge about the patient (e.g., specific to the patient's age, gender, weight and other factors), but this might not be possible or appropriate. Whenever more than one reference range is supplied, the differences between them SHOULD be provided in the reference range and/or age properties.

                  Контроль0..*
                  ТипСмотретьttp://hl7.org/fhir/StructureDefinition/Observation#Observation.referenceRange
                  Модификаторfalse
                  Требуется поддержкаfalse
                  Summaryfalse
                  Требования

                  Knowing what values are considered "normal" can help evaluate the significance of a particular result. Need to be able to provide multiple reference ranges for different contexts.

                  Инвариантыele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
                  594. Observation.component:menstrualCycleDuration
                  Название разрезаmenstrualCycleDuration
                  Определение

                  Some observations have multiple component observations. These component observations are expressed as separate code value pairs that share the same attributes. Examples include systolic and diastolic component observations for blood pressure measurement and multiple component observations for genetics observations.

                  КороткийMenstrual cycle duration
                  Комментарии

                  For a discussion on the ways Observations can be assembled in groups together see Notes below.

                  Контроль0..1
                  На этот элемент влияют следующие инварианты: obs-7
                  ТипBackboneElement
                  Модификаторfalse
                  Требуется поддержкаtrue
                  Summarytrue
                  Требования

                  Component observations share the same attributes in the Observation resource as the primary observation and are always treated a part of a single observation (they are not separable). However, the reference range for the primary observation value is not inherited by the component values and is required when appropriate for each component observation.

                  Инвариантыele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
                  596. Observation.component:menstrualCycleDuration.id
                  Определение

                  Unique id for the element within a resource (for internal references). This may be any string value that does not contain spaces.

                  КороткийUnique id for inter-element referencing
                  Контроль0..1
                  На этот элемент влияют следующие инварианты: ele-1
                  Типstring
                  Модификаторfalse
                  Формат XMLВ формате XML это свойство представлено в качестве атрибута.
                  Summaryfalse
                  598. Observation.component:menstrualCycleDuration.extension
                  Определение

                  May be used to represent additional information that is not part of the basic definition of the element. To make the use of extensions safe and managable, there is a strict set of governance applied to the definition and use of extensions. Though any implementer can define an extension, there is a set of requirements that SHALL be met as part of the definition of the extension.

                  КороткийAdditional content defined by implementations
                  Комментарии

                  There can be no stigma associated with the use of extensions by any application, project, or standard - regardless of the institution or jurisdiction that uses or defines the extensions. The use of extensions is what allows the FHIR specification to retain a core level of simplicity for everyone.

                  Контроль0..*
                  ТипExtension
                  Модификаторfalse
                  Summaryfalse
                  Альтернативные именаextensions, user content
                  Инвариантыele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
                  ext-1: Must have either extensions or value[x], not both (extension.exists() != value.exists())
                  600. Observation.component:menstrualCycleDuration.modifierExtension
                  Определение

                  May be used to represent additional information that is not part of the basic definition of the element and that modifies the understanding of the element in which it is contained and/or the understanding of the containing element's descendants. Usually modifier elements provide negation or qualification. To make the use of extensions safe and managable, there is a strict set of governance applied to the definition and use of extensions. Though any implementer can define an extension, there is a set of requirements that SHALL be met as part of the definition of the extension. Applications processing a resource are required to check for modifier extensions.

                  Modifier extensions SHALL NOT change the meaning of any elements on Resource or DomainResource (including cannot change the meaning of modifierExtension itself).

                  КороткийExtensions that cannot be ignored even if unrecognized
                  Комментарии

                  There can be no stigma associated with the use of extensions by any application, project, or standard - regardless of the institution or jurisdiction that uses or defines the extensions. The use of extensions is what allows the FHIR specification to retain a core level of simplicity for everyone.

                  Контроль0..*
                  ТипExtension
                  Модификаторtrue потому что Modifier extensions are expected to modify the meaning or interpretation of the element that contains them
                  Summarytrue
                  Требования

                  Modifier extensions allow for extensions that cannot be safely ignored to be clearly distinguished from the vast majority of extensions which can be safely ignored. This promotes interoperability by eliminating the need for implementers to prohibit the presence of extensions. For further information, see the definition of modifier extensions.

                  Альтернативные именаextensions, user content, modifiers
                  Инвариантыele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
                  ext-1: Must have either extensions or value[x], not both (extension.exists() != value.exists())
                  602. Observation.component:menstrualCycleDuration.code
                  Определение

                  Describes what was observed. Sometimes this is called the observation "code".

                  КороткийType of component observation (code / type)
                  Комментарии

                  All code-value and component.code-component.value pairs need to be taken into account to correctly understand the meaning of the observation.

                  Контроль1..1
                  На этот элемент влияют следующие инварианты: obs-7
                  ПривязкаКоды СЛЕДУЕТ взять из ObservationCodesVS (0.12.0)
                  (preferred to https://terminology.dhp.uz/fhir/core/ValueSet/observation-codes-vs|0.12.0)
                  ТипCodeableConcept
                  Модификаторfalse
                  Требуется поддержкаtrue
                  Summarytrue
                  Требования

                  Knowing what kind of observation is being made is essential to understanding the observation.

                  Значение шаблона{
                    "coding" : [{
                      "system" : "https://terminology.dhp.uz/fhir/integrations/CodeSystem/screening-ultrasound-parameter-cs",
                      "code" : "scrn-0052-00001"
                    }]
                  }
                  Инвариантыele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
                  604. Observation.component:menstrualCycleDuration.value[x]
                  Определение

                  The information determined as a result of making the observation, if the information has a simple value.

                  КороткийActual component result
                  Комментарии

                  Used when observation has a set of component observations:

                  • An observation may have both a value (e.g. an Apgar score) and component observations (the observations from which the Apgar score was derived).
                  • If a value is present, the datatype for this element should be determined by the code.
                  • CodeableConcept with just a text would be used instead of a string if the field was usually coded, or if the type associated with the code defines a coded value.
                  • Attachment is used if the observation result value is a binary file such as an image. If the observation result value is derived from the binary file (for example 'X' detected and here is the the proof in this image), the binary file may be directly represented using DocumentReference and referenced by derivedFrom.
                  • If a value is present, the datatype for this element should be determined by the code.
                  • CodeableConcept with just a text would be used instead of a string if the field was usually coded, or if the type associated with the code defines a coded value.
                  • Attachment is used if the observation result value is a binary file such as an image. If the observation result value is derived from the binary file (for example 'X' detected and here is the the proof in this image), the binary file may be directly represented using DocumentReference and referenced by derivedFrom.
                  • The usage of valueReference is restricted to the MolecularSequence resource when used as a definitional resource, not as a patient-specific finding. .
                  • For additional guidance, see the Notes section below.
                  Контроль1..1
                  ТипQuantity
                  [x] ЗаметкаСмотретьВыбор типов данныхдля дополнительной информации о том, как использовать [x]
                  Модификаторfalse
                  Требуется поддержкаtrue
                  Summarytrue
                  Требования

                  An observation exists to have a value, though it might not if it is in error, or if it represents a group of observations.

                  Значение шаблона{
                    "unit" : "d",
                    "system" : "http://unitsofmeasure.org",
                    "code" : "d"
                  }
                  Инвариантыele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
                  606. Observation.component:menstrualCycleDuration.value[x].id
                  Определение

                  Unique id for the element within a resource (for internal references). This may be any string value that does not contain spaces.

                  КороткийUnique id for inter-element referencing
                  Контроль0..1
                  На этот элемент влияют следующие инварианты: ele-1
                  Типid
                  Модификаторfalse
                  Формат XMLВ формате XML это свойство представлено в качестве атрибута.
                  Summaryfalse
                  608. Observation.component:menstrualCycleDuration.value[x].extension
                  Определение

                  May be used to represent additional information that is not part of the basic definition of the element. To make the use of extensions safe and managable, there is a strict set of governance applied to the definition and use of extensions. Though any implementer can define an extension, there is a set of requirements that SHALL be met as part of the definition of the extension.

                  КороткийAdditional content defined by implementations
                  Комментарии

                  There can be no stigma associated with the use of extensions by any application, project, or standard - regardless of the institution or jurisdiction that uses or defines the extensions. The use of extensions is what allows the FHIR specification to retain a core level of simplicity for everyone.

                  Контроль0..*
                  ТипExtension
                  Модификаторfalse
                  Summaryfalse
                  Альтернативные именаextensions, user content
                  Инвариантыele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
                  ext-1: Must have either extensions or value[x], not both (extension.exists() != value.exists())
                  SlicingЭтот элемент представляет набор разрезов на Observation.component.value[x].extension. Разрезы бываютНе упорядочено и Open, и могут быть дифференцированы с помощью следующих дискриминаторов:
                  • value @ url
                  • 610. Observation.component:menstrualCycleDuration.value[x].value
                    Определение

                    The value of the measured amount. The value includes an implicit precision in the presentation of the value.

                    КороткийNumerical value (with implicit precision)
                    Комментарии

                    The implicit precision in the value should always be honored. Monetary values have their own rules for handling precision (refer to standard accounting text books).

                    Контроль1..1
                    Типdecimal
                    Модификаторfalse
                    Примитивное значениеЭтот примитивный элемент может присутствовать или отсутствовать, или быть замененным расширением
                    Summarytrue
                    Требования

                    Precision is handled implicitly in almost all cases of measurement.

                    Мин. значение0
                    Инвариантыele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
                    612. Observation.component:menstrualCycleDuration.value[x].comparator
                    Определение

                    How the value should be understood and represented - whether the actual value is greater or less than the stated value due to measurement issues; e.g. if the comparator is "<" , then the real value is < stated value.

                    Короткий< | <= | >= | > | ad - how to understand the value
                    Контроль0..1
                    ПривязкаКоды ДОЛЖНЫ быть взяты из QuantityComparator
                    (required to http://hl7.org/fhir/ValueSet/quantity-comparator|5.0.0)

                    How the Quantity should be understood and represented.

                    Типcode
                    Модификаторtrue потому что This is labeled as "Is Modifier" because the comparator modifies the interpretation of the value significantly. If there is no comparator, then there is no modification of the value
                    Примитивное значениеЭтот примитивный элемент может присутствовать или отсутствовать, или быть замененным расширением
                    Summarytrue
                    Требования

                    Need a framework for handling measures where the value is <5ug/L or >400mg/L due to the limitations of measuring methodology.

                    Значение при отсутствииIf there is no comparator, then there is no modification of the value
                    Инвариантыele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
                    614. Observation.component:menstrualCycleDuration.value[x].unit
                    Определение

                    A human-readable form of the unit.

                    КороткийUnit representation
                    Контроль1..1
                    Типstring
                    Модификаторfalse
                    Примитивное значениеЭтот примитивный элемент может присутствовать или отсутствовать, или быть замененным расширением
                    Summarytrue
                    Требования

                    There are many representations for units of measure and in many contexts, particular representations are fixed and required. I.e. mcg for micrograms.

                    Инвариантыele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
                    616. Observation.component:menstrualCycleDuration.value[x].system
                    Определение

                    The identification of the system that provides the coded form of the unit.

                    КороткийSystem that defines coded unit form
                    Контроль1..1
                    На этот элемент влияют следующие инварианты: qty-3
                    Типuri
                    Модификаторfalse
                    Примитивное значениеЭтот примитивный элемент может присутствовать или отсутствовать, или быть замененным расширением
                    Summarytrue
                    Требования

                    Need to know the system that defines the coded form of the unit.

                    Инвариантыele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
                    618. Observation.component:menstrualCycleDuration.value[x].code
                    Определение

                    A computer processable form of the unit in some unit representation system.

                    КороткийCoded form of the unit
                    Комментарии

                    The preferred system is UCUM, but SNOMED CT can also be used (for customary units) or ISO 4217 for currency. The context of use may additionally require a code from a particular system.

                    Контроль1..1
                    На этот элемент влияют следующие инварианты: qty-3
                    Типcode
                    Модификаторfalse
                    Примитивное значениеЭтот примитивный элемент может присутствовать или отсутствовать, или быть замененным расширением
                    Summarytrue
                    Требования

                    Need a computable form of the unit that is fixed across all forms. UCUM provides this for quantities, but SNOMED CT provides many units of interest.

                    Инвариантыele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
                    620. Observation.component:menstrualCycleDuration.dataAbsentReason
                    Определение

                    Provides a reason why the expected value in the element Observation.component.value[x] is missing.

                    КороткийWhy the component result is missing
                    Комментарии

                    "Null" or exceptional values can be represented two ways in FHIR Observations. One way is to simply include them in the value set and represent the exceptions in the value. For example, measurement values for a serology test could be "detected", "not detected", "inconclusive", or "test not done".

                    The alternate way is to use the value element for actual observations and use the explicit dataAbsentReason element to record exceptional values. For example, the dataAbsentReason code "error" could be used when the measurement was not completed. Because of these options, use-case agreements are required to interpret general observations for exceptional values.

                    Контроль0..1
                    ПривязкаЕсли они не подходят, эти коды ДОЛЖНЫ быть взяты из DataAbsentReasonVS (0.12.0)
                    (extensible to https://terminology.dhp.uz/fhir/core/ValueSet/data-absent-reason-vs|0.12.0)
                    ТипCodeableConcept
                    Модификаторfalse
                    Требуется поддержкаfalse
                    Summaryfalse
                    Требования

                    For many results it is necessary to handle exceptional values in measurements.

                    Инвариантыele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
                    622. Observation.component:menstrualCycleDuration.interpretation
                    Определение

                    A categorical assessment of an observation value. For example, high, low, normal.

                    КороткийHigh, low, normal, etc
                    Комментарии

                    Historically used for laboratory results (known as 'abnormal flag' ), its use extends to other use cases where coded interpretations are relevant. Often reported as one or more simple compact codes this element is often placed adjacent to the result value in reports and flow sheets to signal the meaning/normalcy status of the result.

                    Контроль0..*
                    ПривязкаЕсли они не подходят, эти коды ДОЛЖНЫ быть взяты из ObservationInterpretationVS (0.12.0)
                    (extensible to https://terminology.dhp.uz/fhir/core/ValueSet/observation-interpretation-vs|0.12.0)
                    ТипCodeableConcept
                    Модификаторfalse
                    Требуется поддержкаfalse
                    Summaryfalse
                    Требования

                    For some results, particularly numeric results, an interpretation is necessary to fully understand the significance of a result.

                    Альтернативные именаAbnormal Flag
                    Инвариантыele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
                    624. Observation.component:menstrualCycleDuration.referenceRange
                    Определение

                    Guidance on how to interpret the value by comparison to a normal or recommended range.

                    КороткийProvides guide for interpretation of component result
                    Комментарии

                    Most observations only have one generic reference range. Systems MAY choose to restrict to only supplying the relevant reference range based on knowledge about the patient (e.g., specific to the patient's age, gender, weight and other factors), but this might not be possible or appropriate. Whenever more than one reference range is supplied, the differences between them SHOULD be provided in the reference range and/or age properties.

                    Контроль0..*
                    ТипСмотретьttp://hl7.org/fhir/StructureDefinition/Observation#Observation.referenceRange
                    Модификаторfalse
                    Требуется поддержкаfalse
                    Summaryfalse
                    Требования

                    Knowing what values are considered "normal" can help evaluate the significance of a particular result. Need to be able to provide multiple reference ranges for different contexts.

                    Инвариантыele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
                    626. Observation.component:anamnesis
                    Название разрезаanamnesis
                    Определение

                    Some observations have multiple component observations. These component observations are expressed as separate code value pairs that share the same attributes. Examples include systolic and diastolic component observations for blood pressure measurement and multiple component observations for genetics observations.

                    КороткийUltrasound anamnesis
                    Комментарии

                    For a discussion on the ways Observations can be assembled in groups together see Notes below.

                    Контроль0..1
                    На этот элемент влияют следующие инварианты: obs-7
                    ТипBackboneElement
                    Модификаторfalse
                    Требуется поддержкаtrue
                    Summarytrue
                    Требования

                    Component observations share the same attributes in the Observation resource as the primary observation and are always treated a part of a single observation (they are not separable). However, the reference range for the primary observation value is not inherited by the component values and is required when appropriate for each component observation.

                    Инвариантыele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
                    628. Observation.component:anamnesis.id
                    Определение

                    Unique id for the element within a resource (for internal references). This may be any string value that does not contain spaces.

                    КороткийUnique id for inter-element referencing
                    Контроль0..1
                    На этот элемент влияют следующие инварианты: ele-1
                    Типstring
                    Модификаторfalse
                    Формат XMLВ формате XML это свойство представлено в качестве атрибута.
                    Summaryfalse
                    630. Observation.component:anamnesis.extension
                    Определение

                    May be used to represent additional information that is not part of the basic definition of the element. To make the use of extensions safe and managable, there is a strict set of governance applied to the definition and use of extensions. Though any implementer can define an extension, there is a set of requirements that SHALL be met as part of the definition of the extension.

                    КороткийAdditional content defined by implementations
                    Комментарии

                    There can be no stigma associated with the use of extensions by any application, project, or standard - regardless of the institution or jurisdiction that uses or defines the extensions. The use of extensions is what allows the FHIR specification to retain a core level of simplicity for everyone.

                    Контроль0..*
                    ТипExtension
                    Модификаторfalse
                    Summaryfalse
                    Альтернативные именаextensions, user content
                    Инвариантыele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
                    ext-1: Must have either extensions or value[x], not both (extension.exists() != value.exists())
                    632. Observation.component:anamnesis.modifierExtension
                    Определение

                    May be used to represent additional information that is not part of the basic definition of the element and that modifies the understanding of the element in which it is contained and/or the understanding of the containing element's descendants. Usually modifier elements provide negation or qualification. To make the use of extensions safe and managable, there is a strict set of governance applied to the definition and use of extensions. Though any implementer can define an extension, there is a set of requirements that SHALL be met as part of the definition of the extension. Applications processing a resource are required to check for modifier extensions.

                    Modifier extensions SHALL NOT change the meaning of any elements on Resource or DomainResource (including cannot change the meaning of modifierExtension itself).

                    КороткийExtensions that cannot be ignored even if unrecognized
                    Комментарии

                    There can be no stigma associated with the use of extensions by any application, project, or standard - regardless of the institution or jurisdiction that uses or defines the extensions. The use of extensions is what allows the FHIR specification to retain a core level of simplicity for everyone.

                    Контроль0..*
                    ТипExtension
                    Модификаторtrue потому что Modifier extensions are expected to modify the meaning or interpretation of the element that contains them
                    Summarytrue
                    Требования

                    Modifier extensions allow for extensions that cannot be safely ignored to be clearly distinguished from the vast majority of extensions which can be safely ignored. This promotes interoperability by eliminating the need for implementers to prohibit the presence of extensions. For further information, see the definition of modifier extensions.

                    Альтернативные именаextensions, user content, modifiers
                    Инвариантыele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
                    ext-1: Must have either extensions or value[x], not both (extension.exists() != value.exists())
                    634. Observation.component:anamnesis.code
                    Определение

                    Describes what was observed. Sometimes this is called the observation "code".

                    КороткийType of component observation (code / type)
                    Комментарии

                    All code-value and component.code-component.value pairs need to be taken into account to correctly understand the meaning of the observation.

                    Контроль1..1
                    На этот элемент влияют следующие инварианты: obs-7
                    ПривязкаКоды СЛЕДУЕТ взять из ObservationCodesVS (0.12.0)
                    (preferred to https://terminology.dhp.uz/fhir/core/ValueSet/observation-codes-vs|0.12.0)
                    ТипCodeableConcept
                    Модификаторfalse
                    Требуется поддержкаtrue
                    Summarytrue
                    Требования

                    Knowing what kind of observation is being made is essential to understanding the observation.

                    Значение шаблона{
                      "coding" : [{
                        "system" : "https://terminology.dhp.uz/fhir/integrations/CodeSystem/screening-ultrasound-parameter-cs",
                        "code" : "scrn-0052-00003"
                      }]
                    }
                    Инвариантыele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
                    636. Observation.component:anamnesis.value[x]
                    Определение

                    The information determined as a result of making the observation, if the information has a simple value.

                    КороткийActual component result
                    Комментарии

                    Used when observation has a set of component observations:

                    • An observation may have both a value (e.g. an Apgar score) and component observations (the observations from which the Apgar score was derived).
                    • If a value is present, the datatype for this element should be determined by the code.
                    • CodeableConcept with just a text would be used instead of a string if the field was usually coded, or if the type associated with the code defines a coded value.
                    • Attachment is used if the observation result value is a binary file such as an image. If the observation result value is derived from the binary file (for example 'X' detected and here is the the proof in this image), the binary file may be directly represented using DocumentReference and referenced by derivedFrom.
                    • If a value is present, the datatype for this element should be determined by the code.
                    • CodeableConcept with just a text would be used instead of a string if the field was usually coded, or if the type associated with the code defines a coded value.
                    • Attachment is used if the observation result value is a binary file such as an image. If the observation result value is derived from the binary file (for example 'X' detected and here is the the proof in this image), the binary file may be directly represented using DocumentReference and referenced by derivedFrom.
                    • The usage of valueReference is restricted to the MolecularSequence resource when used as a definitional resource, not as a patient-specific finding. .
                    • For additional guidance, see the Notes section below.
                    Контроль1..1
                    Типstring
                    [x] ЗаметкаСмотретьВыбор типов данныхдля дополнительной информации о том, как использовать [x]
                    Модификаторfalse
                    Примитивное значениеЭтот примитивный элемент может присутствовать или отсутствовать, или быть замененным расширением
                    Требуется поддержкаtrue
                    Summarytrue
                    Требования

                    An observation exists to have a value, though it might not if it is in error, or if it represents a group of observations.

                    Инвариантыele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
                    638. Observation.component:anamnesis.dataAbsentReason
                    Определение

                    Provides a reason why the expected value in the element Observation.component.value[x] is missing.

                    КороткийWhy the component result is missing
                    Комментарии

                    "Null" or exceptional values can be represented two ways in FHIR Observations. One way is to simply include them in the value set and represent the exceptions in the value. For example, measurement values for a serology test could be "detected", "not detected", "inconclusive", or "test not done".

                    The alternate way is to use the value element for actual observations and use the explicit dataAbsentReason element to record exceptional values. For example, the dataAbsentReason code "error" could be used when the measurement was not completed. Because of these options, use-case agreements are required to interpret general observations for exceptional values.

                    Контроль0..1
                    ПривязкаЕсли они не подходят, эти коды ДОЛЖНЫ быть взяты из DataAbsentReasonVS (0.12.0)
                    (extensible to https://terminology.dhp.uz/fhir/core/ValueSet/data-absent-reason-vs|0.12.0)
                    ТипCodeableConcept
                    Модификаторfalse
                    Требуется поддержкаfalse
                    Summaryfalse
                    Требования

                    For many results it is necessary to handle exceptional values in measurements.

                    Инвариантыele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
                    640. Observation.component:anamnesis.interpretation
                    Определение

                    A categorical assessment of an observation value. For example, high, low, normal.

                    КороткийHigh, low, normal, etc
                    Комментарии

                    Historically used for laboratory results (known as 'abnormal flag' ), its use extends to other use cases where coded interpretations are relevant. Often reported as one or more simple compact codes this element is often placed adjacent to the result value in reports and flow sheets to signal the meaning/normalcy status of the result.

                    Контроль0..*
                    ПривязкаЕсли они не подходят, эти коды ДОЛЖНЫ быть взяты из ObservationInterpretationVS (0.12.0)
                    (extensible to https://terminology.dhp.uz/fhir/core/ValueSet/observation-interpretation-vs|0.12.0)
                    ТипCodeableConcept
                    Модификаторfalse
                    Требуется поддержкаfalse
                    Summaryfalse
                    Требования

                    For some results, particularly numeric results, an interpretation is necessary to fully understand the significance of a result.

                    Альтернативные именаAbnormal Flag
                    Инвариантыele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
                    642. Observation.component:anamnesis.referenceRange
                    Определение

                    Guidance on how to interpret the value by comparison to a normal or recommended range.

                    КороткийProvides guide for interpretation of component result
                    Комментарии

                    Most observations only have one generic reference range. Systems MAY choose to restrict to only supplying the relevant reference range based on knowledge about the patient (e.g., specific to the patient's age, gender, weight and other factors), but this might not be possible or appropriate. Whenever more than one reference range is supplied, the differences between them SHOULD be provided in the reference range and/or age properties.

                    Контроль0..*
                    ТипСмотретьttp://hl7.org/fhir/StructureDefinition/Observation#Observation.referenceRange
                    Модификаторfalse
                    Требуется поддержкаfalse
                    Summaryfalse
                    Требования

                    Knowing what values are considered "normal" can help evaluate the significance of a particular result. Need to be able to provide multiple reference ranges for different contexts.

                    Инвариантыele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
                    644. Observation.component:fibroglandularThickness
                    Название разрезаfibroglandularThickness
                    Определение

                    Some observations have multiple component observations. These component observations are expressed as separate code value pairs that share the same attributes. Examples include systolic and diastolic component observations for blood pressure measurement and multiple component observations for genetics observations.

                    КороткийFibroglandular complex thickness
                    Комментарии

                    For a discussion on the ways Observations can be assembled in groups together see Notes below.

                    Контроль0..1
                    На этот элемент влияют следующие инварианты: obs-7
                    ТипBackboneElement
                    Модификаторfalse
                    Требуется поддержкаtrue
                    Summarytrue
                    Требования

                    Component observations share the same attributes in the Observation resource as the primary observation and are always treated a part of a single observation (they are not separable). However, the reference range for the primary observation value is not inherited by the component values and is required when appropriate for each component observation.

                    Инвариантыele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
                    646. Observation.component:fibroglandularThickness.id
                    Определение

                    Unique id for the element within a resource (for internal references). This may be any string value that does not contain spaces.

                    КороткийUnique id for inter-element referencing
                    Контроль0..1
                    На этот элемент влияют следующие инварианты: ele-1
                    Типstring
                    Модификаторfalse
                    Формат XMLВ формате XML это свойство представлено в качестве атрибута.
                    Summaryfalse
                    648. Observation.component:fibroglandularThickness.extension
                    Определение

                    May be used to represent additional information that is not part of the basic definition of the element. To make the use of extensions safe and managable, there is a strict set of governance applied to the definition and use of extensions. Though any implementer can define an extension, there is a set of requirements that SHALL be met as part of the definition of the extension.

                    КороткийAdditional content defined by implementations
                    Комментарии

                    There can be no stigma associated with the use of extensions by any application, project, or standard - regardless of the institution or jurisdiction that uses or defines the extensions. The use of extensions is what allows the FHIR specification to retain a core level of simplicity for everyone.

                    Контроль0..*
                    ТипExtension
                    Модификаторfalse
                    Summaryfalse
                    Альтернативные именаextensions, user content
                    Инвариантыele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
                    ext-1: Must have either extensions or value[x], not both (extension.exists() != value.exists())
                    650. Observation.component:fibroglandularThickness.modifierExtension
                    Определение

                    May be used to represent additional information that is not part of the basic definition of the element and that modifies the understanding of the element in which it is contained and/or the understanding of the containing element's descendants. Usually modifier elements provide negation or qualification. To make the use of extensions safe and managable, there is a strict set of governance applied to the definition and use of extensions. Though any implementer can define an extension, there is a set of requirements that SHALL be met as part of the definition of the extension. Applications processing a resource are required to check for modifier extensions.

                    Modifier extensions SHALL NOT change the meaning of any elements on Resource or DomainResource (including cannot change the meaning of modifierExtension itself).

                    КороткийExtensions that cannot be ignored even if unrecognized
                    Комментарии

                    There can be no stigma associated with the use of extensions by any application, project, or standard - regardless of the institution or jurisdiction that uses or defines the extensions. The use of extensions is what allows the FHIR specification to retain a core level of simplicity for everyone.

                    Контроль0..*
                    ТипExtension
                    Модификаторtrue потому что Modifier extensions are expected to modify the meaning or interpretation of the element that contains them
                    Summarytrue
                    Требования

                    Modifier extensions allow for extensions that cannot be safely ignored to be clearly distinguished from the vast majority of extensions which can be safely ignored. This promotes interoperability by eliminating the need for implementers to prohibit the presence of extensions. For further information, see the definition of modifier extensions.

                    Альтернативные именаextensions, user content, modifiers
                    Инвариантыele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
                    ext-1: Must have either extensions or value[x], not both (extension.exists() != value.exists())
                    652. Observation.component:fibroglandularThickness.code
                    Определение

                    Describes what was observed. Sometimes this is called the observation "code".

                    КороткийType of component observation (code / type)
                    Комментарии

                    All code-value and component.code-component.value pairs need to be taken into account to correctly understand the meaning of the observation.

                    Контроль1..1
                    На этот элемент влияют следующие инварианты: obs-7
                    ПривязкаКоды СЛЕДУЕТ взять из ObservationCodesVS (0.12.0)
                    (preferred to https://terminology.dhp.uz/fhir/core/ValueSet/observation-codes-vs|0.12.0)
                    ТипCodeableConcept
                    Модификаторfalse
                    Требуется поддержкаtrue
                    Summarytrue
                    Требования

                    Knowing what kind of observation is being made is essential to understanding the observation.

                    Значение шаблона{
                      "coding" : [{
                        "system" : "https://terminology.dhp.uz/fhir/integrations/CodeSystem/screening-ultrasound-parameter-cs",
                        "code" : "scrn-0052-00009"
                      }]
                    }
                    Инвариантыele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
                    654. Observation.component:fibroglandularThickness.value[x]
                    Определение

                    The information determined as a result of making the observation, if the information has a simple value.

                    КороткийActual component result
                    Комментарии

                    Used when observation has a set of component observations:

                    • An observation may have both a value (e.g. an Apgar score) and component observations (the observations from which the Apgar score was derived).
                    • If a value is present, the datatype for this element should be determined by the code.
                    • CodeableConcept with just a text would be used instead of a string if the field was usually coded, or if the type associated with the code defines a coded value.
                    • Attachment is used if the observation result value is a binary file such as an image. If the observation result value is derived from the binary file (for example 'X' detected and here is the the proof in this image), the binary file may be directly represented using DocumentReference and referenced by derivedFrom.
                    • If a value is present, the datatype for this element should be determined by the code.
                    • CodeableConcept with just a text would be used instead of a string if the field was usually coded, or if the type associated with the code defines a coded value.
                    • Attachment is used if the observation result value is a binary file such as an image. If the observation result value is derived from the binary file (for example 'X' detected and here is the the proof in this image), the binary file may be directly represented using DocumentReference and referenced by derivedFrom.
                    • The usage of valueReference is restricted to the MolecularSequence resource when used as a definitional resource, not as a patient-specific finding. .
                    • For additional guidance, see the Notes section below.
                    Контроль1..1
                    ТипQuantity
                    [x] ЗаметкаСмотретьВыбор типов данныхдля дополнительной информации о том, как использовать [x]
                    Модификаторfalse
                    Требуется поддержкаtrue
                    Summarytrue
                    Требования

                    An observation exists to have a value, though it might not if it is in error, or if it represents a group of observations.

                    Значение шаблона{
                      "unit" : "mm",
                      "system" : "http://unitsofmeasure.org",
                      "code" : "mm"
                    }
                    Инвариантыele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
                    656. Observation.component:fibroglandularThickness.value[x].id
                    Определение

                    Unique id for the element within a resource (for internal references). This may be any string value that does not contain spaces.

                    КороткийUnique id for inter-element referencing
                    Контроль0..1
                    На этот элемент влияют следующие инварианты: ele-1
                    Типid
                    Модификаторfalse
                    Формат XMLВ формате XML это свойство представлено в качестве атрибута.
                    Summaryfalse
                    658. Observation.component:fibroglandularThickness.value[x].extension
                    Определение

                    May be used to represent additional information that is not part of the basic definition of the element. To make the use of extensions safe and managable, there is a strict set of governance applied to the definition and use of extensions. Though any implementer can define an extension, there is a set of requirements that SHALL be met as part of the definition of the extension.

                    КороткийAdditional content defined by implementations
                    Комментарии

                    There can be no stigma associated with the use of extensions by any application, project, or standard - regardless of the institution or jurisdiction that uses or defines the extensions. The use of extensions is what allows the FHIR specification to retain a core level of simplicity for everyone.

                    Контроль0..*
                    ТипExtension
                    Модификаторfalse
                    Summaryfalse
                    Альтернативные именаextensions, user content
                    Инвариантыele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
                    ext-1: Must have either extensions or value[x], not both (extension.exists() != value.exists())
                    SlicingЭтот элемент представляет набор разрезов на Observation.component.value[x].extension. Разрезы бываютНе упорядочено и Open, и могут быть дифференцированы с помощью следующих дискриминаторов:
                    • value @ url
                    • 660. Observation.component:fibroglandularThickness.value[x].value
                      Определение

                      The value of the measured amount. The value includes an implicit precision in the presentation of the value.

                      КороткийNumerical value (with implicit precision)
                      Комментарии

                      The implicit precision in the value should always be honored. Monetary values have their own rules for handling precision (refer to standard accounting text books).

                      Контроль1..1
                      Типdecimal
                      Модификаторfalse
                      Примитивное значениеЭтот примитивный элемент может присутствовать или отсутствовать, или быть замененным расширением
                      Summarytrue
                      Требования

                      Precision is handled implicitly in almost all cases of measurement.

                      Мин. значение0
                      Инвариантыele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
                      662. Observation.component:fibroglandularThickness.value[x].comparator
                      Определение

                      How the value should be understood and represented - whether the actual value is greater or less than the stated value due to measurement issues; e.g. if the comparator is "<" , then the real value is < stated value.

                      Короткий< | <= | >= | > | ad - how to understand the value
                      Контроль0..1
                      ПривязкаКоды ДОЛЖНЫ быть взяты из QuantityComparator
                      (required to http://hl7.org/fhir/ValueSet/quantity-comparator|5.0.0)

                      How the Quantity should be understood and represented.

                      Типcode
                      Модификаторtrue потому что This is labeled as "Is Modifier" because the comparator modifies the interpretation of the value significantly. If there is no comparator, then there is no modification of the value
                      Примитивное значениеЭтот примитивный элемент может присутствовать или отсутствовать, или быть замененным расширением
                      Summarytrue
                      Требования

                      Need a framework for handling measures where the value is <5ug/L or >400mg/L due to the limitations of measuring methodology.

                      Значение при отсутствииIf there is no comparator, then there is no modification of the value
                      Инвариантыele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
                      664. Observation.component:fibroglandularThickness.value[x].unit
                      Определение

                      A human-readable form of the unit.

                      КороткийUnit representation
                      Контроль1..1
                      Типstring
                      Модификаторfalse
                      Примитивное значениеЭтот примитивный элемент может присутствовать или отсутствовать, или быть замененным расширением
                      Summarytrue
                      Требования

                      There are many representations for units of measure and in many contexts, particular representations are fixed and required. I.e. mcg for micrograms.

                      Инвариантыele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
                      666. Observation.component:fibroglandularThickness.value[x].system
                      Определение

                      The identification of the system that provides the coded form of the unit.

                      КороткийSystem that defines coded unit form
                      Контроль1..1
                      На этот элемент влияют следующие инварианты: qty-3
                      Типuri
                      Модификаторfalse
                      Примитивное значениеЭтот примитивный элемент может присутствовать или отсутствовать, или быть замененным расширением
                      Summarytrue
                      Требования

                      Need to know the system that defines the coded form of the unit.

                      Инвариантыele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
                      668. Observation.component:fibroglandularThickness.value[x].code
                      Определение

                      A computer processable form of the unit in some unit representation system.

                      КороткийCoded form of the unit
                      Комментарии

                      The preferred system is UCUM, but SNOMED CT can also be used (for customary units) or ISO 4217 for currency. The context of use may additionally require a code from a particular system.

                      Контроль1..1
                      На этот элемент влияют следующие инварианты: qty-3
                      Типcode
                      Модификаторfalse
                      Примитивное значениеЭтот примитивный элемент может присутствовать или отсутствовать, или быть замененным расширением
                      Summarytrue
                      Требования

                      Need a computable form of the unit that is fixed across all forms. UCUM provides this for quantities, but SNOMED CT provides many units of interest.

                      Инвариантыele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
                      670. Observation.component:fibroglandularThickness.dataAbsentReason
                      Определение

                      Provides a reason why the expected value in the element Observation.component.value[x] is missing.

                      КороткийWhy the component result is missing
                      Комментарии

                      "Null" or exceptional values can be represented two ways in FHIR Observations. One way is to simply include them in the value set and represent the exceptions in the value. For example, measurement values for a serology test could be "detected", "not detected", "inconclusive", or "test not done".

                      The alternate way is to use the value element for actual observations and use the explicit dataAbsentReason element to record exceptional values. For example, the dataAbsentReason code "error" could be used when the measurement was not completed. Because of these options, use-case agreements are required to interpret general observations for exceptional values.

                      Контроль0..1
                      ПривязкаЕсли они не подходят, эти коды ДОЛЖНЫ быть взяты из DataAbsentReasonVS (0.12.0)
                      (extensible to https://terminology.dhp.uz/fhir/core/ValueSet/data-absent-reason-vs|0.12.0)
                      ТипCodeableConcept
                      Модификаторfalse
                      Требуется поддержкаfalse
                      Summaryfalse
                      Требования

                      For many results it is necessary to handle exceptional values in measurements.

                      Инвариантыele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
                      672. Observation.component:fibroglandularThickness.interpretation
                      Определение

                      A categorical assessment of an observation value. For example, high, low, normal.

                      КороткийHigh, low, normal, etc
                      Комментарии

                      Historically used for laboratory results (known as 'abnormal flag' ), its use extends to other use cases where coded interpretations are relevant. Often reported as one or more simple compact codes this element is often placed adjacent to the result value in reports and flow sheets to signal the meaning/normalcy status of the result.

                      Контроль0..*
                      ПривязкаЕсли они не подходят, эти коды ДОЛЖНЫ быть взяты из ObservationInterpretationVS (0.12.0)
                      (extensible to https://terminology.dhp.uz/fhir/core/ValueSet/observation-interpretation-vs|0.12.0)
                      ТипCodeableConcept
                      Модификаторfalse
                      Требуется поддержкаfalse
                      Summaryfalse
                      Требования

                      For some results, particularly numeric results, an interpretation is necessary to fully understand the significance of a result.

                      Альтернативные именаAbnormal Flag
                      Инвариантыele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
                      674. Observation.component:fibroglandularThickness.referenceRange
                      Определение

                      Guidance on how to interpret the value by comparison to a normal or recommended range.

                      КороткийProvides guide for interpretation of component result
                      Комментарии

                      Most observations only have one generic reference range. Systems MAY choose to restrict to only supplying the relevant reference range based on knowledge about the patient (e.g., specific to the patient's age, gender, weight and other factors), but this might not be possible or appropriate. Whenever more than one reference range is supplied, the differences between them SHOULD be provided in the reference range and/or age properties.

                      Контроль0..*
                      ТипСмотретьttp://hl7.org/fhir/StructureDefinition/Observation#Observation.referenceRange
                      Модификаторfalse
                      Требуется поддержкаfalse
                      Summaryfalse
                      Требования

                      Knowing what values are considered "normal" can help evaluate the significance of a particular result. Need to be able to provide multiple reference ranges for different contexts.

                      Инвариантыele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
                      676. Observation.component:maximumDuctDiameter
                      Название разрезаmaximumDuctDiameter
                      Определение

                      Some observations have multiple component observations. These component observations are expressed as separate code value pairs that share the same attributes. Examples include systolic and diastolic component observations for blood pressure measurement and multiple component observations for genetics observations.

                      КороткийMaximum duct diameter
                      Комментарии

                      For a discussion on the ways Observations can be assembled in groups together see Notes below.

                      Контроль0..1
                      На этот элемент влияют следующие инварианты: obs-7
                      ТипBackboneElement
                      Модификаторfalse
                      Требуется поддержкаtrue
                      Summarytrue
                      Требования

                      Component observations share the same attributes in the Observation resource as the primary observation and are always treated a part of a single observation (they are not separable). However, the reference range for the primary observation value is not inherited by the component values and is required when appropriate for each component observation.

                      Инвариантыele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
                      678. Observation.component:maximumDuctDiameter.id
                      Определение

                      Unique id for the element within a resource (for internal references). This may be any string value that does not contain spaces.

                      КороткийUnique id for inter-element referencing
                      Контроль0..1
                      На этот элемент влияют следующие инварианты: ele-1
                      Типstring
                      Модификаторfalse
                      Формат XMLВ формате XML это свойство представлено в качестве атрибута.
                      Summaryfalse
                      680. Observation.component:maximumDuctDiameter.extension
                      Определение

                      May be used to represent additional information that is not part of the basic definition of the element. To make the use of extensions safe and managable, there is a strict set of governance applied to the definition and use of extensions. Though any implementer can define an extension, there is a set of requirements that SHALL be met as part of the definition of the extension.

                      КороткийAdditional content defined by implementations
                      Комментарии

                      There can be no stigma associated with the use of extensions by any application, project, or standard - regardless of the institution or jurisdiction that uses or defines the extensions. The use of extensions is what allows the FHIR specification to retain a core level of simplicity for everyone.

                      Контроль0..*
                      ТипExtension
                      Модификаторfalse
                      Summaryfalse
                      Альтернативные именаextensions, user content
                      Инвариантыele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
                      ext-1: Must have either extensions or value[x], not both (extension.exists() != value.exists())
                      682. Observation.component:maximumDuctDiameter.modifierExtension
                      Определение

                      May be used to represent additional information that is not part of the basic definition of the element and that modifies the understanding of the element in which it is contained and/or the understanding of the containing element's descendants. Usually modifier elements provide negation or qualification. To make the use of extensions safe and managable, there is a strict set of governance applied to the definition and use of extensions. Though any implementer can define an extension, there is a set of requirements that SHALL be met as part of the definition of the extension. Applications processing a resource are required to check for modifier extensions.

                      Modifier extensions SHALL NOT change the meaning of any elements on Resource or DomainResource (including cannot change the meaning of modifierExtension itself).

                      КороткийExtensions that cannot be ignored even if unrecognized
                      Комментарии

                      There can be no stigma associated with the use of extensions by any application, project, or standard - regardless of the institution or jurisdiction that uses or defines the extensions. The use of extensions is what allows the FHIR specification to retain a core level of simplicity for everyone.

                      Контроль0..*
                      ТипExtension
                      Модификаторtrue потому что Modifier extensions are expected to modify the meaning or interpretation of the element that contains them
                      Summarytrue
                      Требования

                      Modifier extensions allow for extensions that cannot be safely ignored to be clearly distinguished from the vast majority of extensions which can be safely ignored. This promotes interoperability by eliminating the need for implementers to prohibit the presence of extensions. For further information, see the definition of modifier extensions.

                      Альтернативные именаextensions, user content, modifiers
                      Инвариантыele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
                      ext-1: Must have either extensions or value[x], not both (extension.exists() != value.exists())
                      684. Observation.component:maximumDuctDiameter.code
                      Определение

                      Describes what was observed. Sometimes this is called the observation "code".

                      КороткийType of component observation (code / type)
                      Комментарии

                      All code-value and component.code-component.value pairs need to be taken into account to correctly understand the meaning of the observation.

                      Контроль1..1
                      На этот элемент влияют следующие инварианты: obs-7
                      ПривязкаКоды СЛЕДУЕТ взять из ObservationCodesVS (0.12.0)
                      (preferred to https://terminology.dhp.uz/fhir/core/ValueSet/observation-codes-vs|0.12.0)
                      ТипCodeableConcept
                      Модификаторfalse
                      Требуется поддержкаtrue
                      Summarytrue
                      Требования

                      Knowing what kind of observation is being made is essential to understanding the observation.

                      Значение шаблона{
                        "coding" : [{
                          "system" : "https://terminology.dhp.uz/fhir/integrations/CodeSystem/screening-ultrasound-parameter-cs",
                          "code" : "scrn-0052-00011"
                        }]
                      }
                      Инвариантыele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
                      686. Observation.component:maximumDuctDiameter.value[x]
                      Определение

                      The information determined as a result of making the observation, if the information has a simple value.

                      КороткийActual component result
                      Комментарии

                      Used when observation has a set of component observations:

                      • An observation may have both a value (e.g. an Apgar score) and component observations (the observations from which the Apgar score was derived).
                      • If a value is present, the datatype for this element should be determined by the code.
                      • CodeableConcept with just a text would be used instead of a string if the field was usually coded, or if the type associated with the code defines a coded value.
                      • Attachment is used if the observation result value is a binary file such as an image. If the observation result value is derived from the binary file (for example 'X' detected and here is the the proof in this image), the binary file may be directly represented using DocumentReference and referenced by derivedFrom.
                      • If a value is present, the datatype for this element should be determined by the code.
                      • CodeableConcept with just a text would be used instead of a string if the field was usually coded, or if the type associated with the code defines a coded value.
                      • Attachment is used if the observation result value is a binary file such as an image. If the observation result value is derived from the binary file (for example 'X' detected and here is the the proof in this image), the binary file may be directly represented using DocumentReference and referenced by derivedFrom.
                      • The usage of valueReference is restricted to the MolecularSequence resource when used as a definitional resource, not as a patient-specific finding. .
                      • For additional guidance, see the Notes section below.
                      Контроль1..1
                      ТипQuantity
                      [x] ЗаметкаСмотретьВыбор типов данныхдля дополнительной информации о том, как использовать [x]
                      Модификаторfalse
                      Требуется поддержкаtrue
                      Summarytrue
                      Требования

                      An observation exists to have a value, though it might not if it is in error, or if it represents a group of observations.

                      Значение шаблона{
                        "unit" : "mm",
                        "system" : "http://unitsofmeasure.org",
                        "code" : "mm"
                      }
                      Инвариантыele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
                      688. Observation.component:maximumDuctDiameter.value[x].id
                      Определение

                      Unique id for the element within a resource (for internal references). This may be any string value that does not contain spaces.

                      КороткийUnique id for inter-element referencing
                      Контроль0..1
                      На этот элемент влияют следующие инварианты: ele-1
                      Типid
                      Модификаторfalse
                      Формат XMLВ формате XML это свойство представлено в качестве атрибута.
                      Summaryfalse
                      690. Observation.component:maximumDuctDiameter.value[x].extension
                      Определение

                      May be used to represent additional information that is not part of the basic definition of the element. To make the use of extensions safe and managable, there is a strict set of governance applied to the definition and use of extensions. Though any implementer can define an extension, there is a set of requirements that SHALL be met as part of the definition of the extension.

                      КороткийAdditional content defined by implementations
                      Комментарии

                      There can be no stigma associated with the use of extensions by any application, project, or standard - regardless of the institution or jurisdiction that uses or defines the extensions. The use of extensions is what allows the FHIR specification to retain a core level of simplicity for everyone.

                      Контроль0..*
                      ТипExtension
                      Модификаторfalse
                      Summaryfalse
                      Альтернативные именаextensions, user content
                      Инвариантыele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
                      ext-1: Must have either extensions or value[x], not both (extension.exists() != value.exists())
                      SlicingЭтот элемент представляет набор разрезов на Observation.component.value[x].extension. Разрезы бываютНе упорядочено и Open, и могут быть дифференцированы с помощью следующих дискриминаторов:
                      • value @ url
                      • 692. Observation.component:maximumDuctDiameter.value[x].value
                        Определение

                        The value of the measured amount. The value includes an implicit precision in the presentation of the value.

                        КороткийNumerical value (with implicit precision)
                        Комментарии

                        The implicit precision in the value should always be honored. Monetary values have their own rules for handling precision (refer to standard accounting text books).

                        Контроль1..1
                        Типdecimal
                        Модификаторfalse
                        Примитивное значениеЭтот примитивный элемент может присутствовать или отсутствовать, или быть замененным расширением
                        Summarytrue
                        Требования

                        Precision is handled implicitly in almost all cases of measurement.

                        Мин. значение0
                        Инвариантыele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
                        694. Observation.component:maximumDuctDiameter.value[x].comparator
                        Определение

                        How the value should be understood and represented - whether the actual value is greater or less than the stated value due to measurement issues; e.g. if the comparator is "<" , then the real value is < stated value.

                        Короткий< | <= | >= | > | ad - how to understand the value
                        Контроль0..1
                        ПривязкаКоды ДОЛЖНЫ быть взяты из QuantityComparator
                        (required to http://hl7.org/fhir/ValueSet/quantity-comparator|5.0.0)

                        How the Quantity should be understood and represented.

                        Типcode
                        Модификаторtrue потому что This is labeled as "Is Modifier" because the comparator modifies the interpretation of the value significantly. If there is no comparator, then there is no modification of the value
                        Примитивное значениеЭтот примитивный элемент может присутствовать или отсутствовать, или быть замененным расширением
                        Summarytrue
                        Требования

                        Need a framework for handling measures where the value is <5ug/L or >400mg/L due to the limitations of measuring methodology.

                        Значение при отсутствииIf there is no comparator, then there is no modification of the value
                        Инвариантыele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
                        696. Observation.component:maximumDuctDiameter.value[x].unit
                        Определение

                        A human-readable form of the unit.

                        КороткийUnit representation
                        Контроль1..1
                        Типstring
                        Модификаторfalse
                        Примитивное значениеЭтот примитивный элемент может присутствовать или отсутствовать, или быть замененным расширением
                        Summarytrue
                        Требования

                        There are many representations for units of measure and in many contexts, particular representations are fixed and required. I.e. mcg for micrograms.

                        Инвариантыele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
                        698. Observation.component:maximumDuctDiameter.value[x].system
                        Определение

                        The identification of the system that provides the coded form of the unit.

                        КороткийSystem that defines coded unit form
                        Контроль1..1
                        На этот элемент влияют следующие инварианты: qty-3
                        Типuri
                        Модификаторfalse
                        Примитивное значениеЭтот примитивный элемент может присутствовать или отсутствовать, или быть замененным расширением
                        Summarytrue
                        Требования

                        Need to know the system that defines the coded form of the unit.

                        Инвариантыele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
                        700. Observation.component:maximumDuctDiameter.value[x].code
                        Определение

                        A computer processable form of the unit in some unit representation system.

                        КороткийCoded form of the unit
                        Комментарии

                        The preferred system is UCUM, but SNOMED CT can also be used (for customary units) or ISO 4217 for currency. The context of use may additionally require a code from a particular system.

                        Контроль1..1
                        На этот элемент влияют следующие инварианты: qty-3
                        Типcode
                        Модификаторfalse
                        Примитивное значениеЭтот примитивный элемент может присутствовать или отсутствовать, или быть замененным расширением
                        Summarytrue
                        Требования

                        Need a computable form of the unit that is fixed across all forms. UCUM provides this for quantities, but SNOMED CT provides many units of interest.

                        Инвариантыele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
                        702. Observation.component:maximumDuctDiameter.dataAbsentReason
                        Определение

                        Provides a reason why the expected value in the element Observation.component.value[x] is missing.

                        КороткийWhy the component result is missing
                        Комментарии

                        "Null" or exceptional values can be represented two ways in FHIR Observations. One way is to simply include them in the value set and represent the exceptions in the value. For example, measurement values for a serology test could be "detected", "not detected", "inconclusive", or "test not done".

                        The alternate way is to use the value element for actual observations and use the explicit dataAbsentReason element to record exceptional values. For example, the dataAbsentReason code "error" could be used when the measurement was not completed. Because of these options, use-case agreements are required to interpret general observations for exceptional values.

                        Контроль0..1
                        ПривязкаЕсли они не подходят, эти коды ДОЛЖНЫ быть взяты из DataAbsentReasonVS (0.12.0)
                        (extensible to https://terminology.dhp.uz/fhir/core/ValueSet/data-absent-reason-vs|0.12.0)
                        ТипCodeableConcept
                        Модификаторfalse
                        Требуется поддержкаfalse
                        Summaryfalse
                        Требования

                        For many results it is necessary to handle exceptional values in measurements.

                        Инвариантыele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
                        704. Observation.component:maximumDuctDiameter.interpretation
                        Определение

                        A categorical assessment of an observation value. For example, high, low, normal.

                        КороткийHigh, low, normal, etc
                        Комментарии

                        Historically used for laboratory results (known as 'abnormal flag' ), its use extends to other use cases where coded interpretations are relevant. Often reported as one or more simple compact codes this element is often placed adjacent to the result value in reports and flow sheets to signal the meaning/normalcy status of the result.

                        Контроль0..*
                        ПривязкаЕсли они не подходят, эти коды ДОЛЖНЫ быть взяты из ObservationInterpretationVS (0.12.0)
                        (extensible to https://terminology.dhp.uz/fhir/core/ValueSet/observation-interpretation-vs|0.12.0)
                        ТипCodeableConcept
                        Модификаторfalse
                        Требуется поддержкаfalse
                        Summaryfalse
                        Требования

                        For some results, particularly numeric results, an interpretation is necessary to fully understand the significance of a result.

                        Альтернативные именаAbnormal Flag
                        Инвариантыele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
                        706. Observation.component:maximumDuctDiameter.referenceRange
                        Определение

                        Guidance on how to interpret the value by comparison to a normal or recommended range.

                        КороткийProvides guide for interpretation of component result
                        Комментарии

                        Most observations only have one generic reference range. Systems MAY choose to restrict to only supplying the relevant reference range based on knowledge about the patient (e.g., specific to the patient's age, gender, weight and other factors), but this might not be possible or appropriate. Whenever more than one reference range is supplied, the differences between them SHOULD be provided in the reference range and/or age properties.

                        Контроль0..*
                        ТипСмотретьttp://hl7.org/fhir/StructureDefinition/Observation#Observation.referenceRange
                        Модификаторfalse
                        Требуется поддержкаfalse
                        Summaryfalse
                        Требования

                        Knowing what values are considered "normal" can help evaluate the significance of a particular result. Need to be able to provide multiple reference ranges for different contexts.

                        Инвариантыele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
                        708. Observation.component:elastographyStiffness
                        Название разрезаelastographyStiffness
                        Определение

                        Some observations have multiple component observations. These component observations are expressed as separate code value pairs that share the same attributes. Examples include systolic and diastolic component observations for blood pressure measurement and multiple component observations for genetics observations.

                        КороткийElastography stiffness; unit is supplied by Screening
                        Комментарии

                        For a discussion on the ways Observations can be assembled in groups together see Notes below.

                        Контроль0..1
                        На этот элемент влияют следующие инварианты: obs-7
                        ТипBackboneElement
                        Модификаторfalse
                        Требуется поддержкаtrue
                        Summarytrue
                        Требования

                        Component observations share the same attributes in the Observation resource as the primary observation and are always treated a part of a single observation (they are not separable). However, the reference range for the primary observation value is not inherited by the component values and is required when appropriate for each component observation.

                        Инвариантыele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
                        710. Observation.component:elastographyStiffness.id
                        Определение

                        Unique id for the element within a resource (for internal references). This may be any string value that does not contain spaces.

                        КороткийUnique id for inter-element referencing
                        Контроль0..1
                        На этот элемент влияют следующие инварианты: ele-1
                        Типstring
                        Модификаторfalse
                        Формат XMLВ формате XML это свойство представлено в качестве атрибута.
                        Summaryfalse
                        712. Observation.component:elastographyStiffness.extension
                        Определение

                        May be used to represent additional information that is not part of the basic definition of the element. To make the use of extensions safe and managable, there is a strict set of governance applied to the definition and use of extensions. Though any implementer can define an extension, there is a set of requirements that SHALL be met as part of the definition of the extension.

                        КороткийAdditional content defined by implementations
                        Комментарии

                        There can be no stigma associated with the use of extensions by any application, project, or standard - regardless of the institution or jurisdiction that uses or defines the extensions. The use of extensions is what allows the FHIR specification to retain a core level of simplicity for everyone.

                        Контроль0..*
                        ТипExtension
                        Модификаторfalse
                        Summaryfalse
                        Альтернативные именаextensions, user content
                        Инвариантыele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
                        ext-1: Must have either extensions or value[x], not both (extension.exists() != value.exists())
                        714. Observation.component:elastographyStiffness.modifierExtension
                        Определение

                        May be used to represent additional information that is not part of the basic definition of the element and that modifies the understanding of the element in which it is contained and/or the understanding of the containing element's descendants. Usually modifier elements provide negation or qualification. To make the use of extensions safe and managable, there is a strict set of governance applied to the definition and use of extensions. Though any implementer can define an extension, there is a set of requirements that SHALL be met as part of the definition of the extension. Applications processing a resource are required to check for modifier extensions.

                        Modifier extensions SHALL NOT change the meaning of any elements on Resource or DomainResource (including cannot change the meaning of modifierExtension itself).

                        КороткийExtensions that cannot be ignored even if unrecognized
                        Комментарии

                        There can be no stigma associated with the use of extensions by any application, project, or standard - regardless of the institution or jurisdiction that uses or defines the extensions. The use of extensions is what allows the FHIR specification to retain a core level of simplicity for everyone.

                        Контроль0..*
                        ТипExtension
                        Модификаторtrue потому что Modifier extensions are expected to modify the meaning or interpretation of the element that contains them
                        Summarytrue
                        Требования

                        Modifier extensions allow for extensions that cannot be safely ignored to be clearly distinguished from the vast majority of extensions which can be safely ignored. This promotes interoperability by eliminating the need for implementers to prohibit the presence of extensions. For further information, see the definition of modifier extensions.

                        Альтернативные именаextensions, user content, modifiers
                        Инвариантыele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
                        ext-1: Must have either extensions or value[x], not both (extension.exists() != value.exists())
                        716. Observation.component:elastographyStiffness.code
                        Определение

                        Describes what was observed. Sometimes this is called the observation "code".

                        КороткийType of component observation (code / type)
                        Комментарии

                        All code-value and component.code-component.value pairs need to be taken into account to correctly understand the meaning of the observation.

                        Контроль1..1
                        На этот элемент влияют следующие инварианты: obs-7
                        ПривязкаКоды СЛЕДУЕТ взять из ObservationCodesVS (0.12.0)
                        (preferred to https://terminology.dhp.uz/fhir/core/ValueSet/observation-codes-vs|0.12.0)
                        ТипCodeableConcept
                        Модификаторfalse
                        Требуется поддержкаtrue
                        Summarytrue
                        Требования

                        Knowing what kind of observation is being made is essential to understanding the observation.

                        Значение шаблона{
                          "coding" : [{
                            "system" : "https://terminology.dhp.uz/fhir/integrations/CodeSystem/screening-ultrasound-parameter-cs",
                            "code" : "scrn-0052-00014"
                          }]
                        }
                        Инвариантыele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
                        718. Observation.component:elastographyStiffness.value[x]
                        Определение

                        The information determined as a result of making the observation, if the information has a simple value.

                        КороткийActual component result
                        Комментарии

                        Used when observation has a set of component observations:

                        • An observation may have both a value (e.g. an Apgar score) and component observations (the observations from which the Apgar score was derived).
                        • If a value is present, the datatype for this element should be determined by the code.
                        • CodeableConcept with just a text would be used instead of a string if the field was usually coded, or if the type associated with the code defines a coded value.
                        • Attachment is used if the observation result value is a binary file such as an image. If the observation result value is derived from the binary file (for example 'X' detected and here is the the proof in this image), the binary file may be directly represented using DocumentReference and referenced by derivedFrom.
                        • If a value is present, the datatype for this element should be determined by the code.
                        • CodeableConcept with just a text would be used instead of a string if the field was usually coded, or if the type associated with the code defines a coded value.
                        • Attachment is used if the observation result value is a binary file such as an image. If the observation result value is derived from the binary file (for example 'X' detected and here is the the proof in this image), the binary file may be directly represented using DocumentReference and referenced by derivedFrom.
                        • The usage of valueReference is restricted to the MolecularSequence resource when used as a definitional resource, not as a patient-specific finding. .
                        • For additional guidance, see the Notes section below.
                        Контроль1..1
                        ТипQuantity
                        [x] ЗаметкаСмотретьВыбор типов данныхдля дополнительной информации о том, как использовать [x]
                        Модификаторfalse
                        Требуется поддержкаtrue
                        Summarytrue
                        Требования

                        An observation exists to have a value, though it might not if it is in error, or if it represents a group of observations.

                        Значение шаблона{
                          "system" : "http://unitsofmeasure.org"
                        }
                        Инвариантыele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
                        720. Observation.component:elastographyStiffness.value[x].id
                        Определение

                        Unique id for the element within a resource (for internal references). This may be any string value that does not contain spaces.

                        КороткийUnique id for inter-element referencing
                        Контроль0..1
                        На этот элемент влияют следующие инварианты: ele-1
                        Типid
                        Модификаторfalse
                        Формат XMLВ формате XML это свойство представлено в качестве атрибута.
                        Summaryfalse
                        722. Observation.component:elastographyStiffness.value[x].extension
                        Определение

                        May be used to represent additional information that is not part of the basic definition of the element. To make the use of extensions safe and managable, there is a strict set of governance applied to the definition and use of extensions. Though any implementer can define an extension, there is a set of requirements that SHALL be met as part of the definition of the extension.

                        КороткийAdditional content defined by implementations
                        Комментарии

                        There can be no stigma associated with the use of extensions by any application, project, or standard - regardless of the institution or jurisdiction that uses or defines the extensions. The use of extensions is what allows the FHIR specification to retain a core level of simplicity for everyone.

                        Контроль0..*
                        ТипExtension
                        Модификаторfalse
                        Summaryfalse
                        Альтернативные именаextensions, user content
                        Инвариантыele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
                        ext-1: Must have either extensions or value[x], not both (extension.exists() != value.exists())
                        SlicingЭтот элемент представляет набор разрезов на Observation.component.value[x].extension. Разрезы бываютНе упорядочено и Open, и могут быть дифференцированы с помощью следующих дискриминаторов:
                        • value @ url
                        • 724. Observation.component:elastographyStiffness.value[x].value
                          Определение

                          The value of the measured amount. The value includes an implicit precision in the presentation of the value.

                          КороткийNumerical value (with implicit precision)
                          Комментарии

                          The implicit precision in the value should always be honored. Monetary values have their own rules for handling precision (refer to standard accounting text books).

                          Контроль1..1
                          Типdecimal
                          Модификаторfalse
                          Примитивное значениеЭтот примитивный элемент может присутствовать или отсутствовать, или быть замененным расширением
                          Summarytrue
                          Требования

                          Precision is handled implicitly in almost all cases of measurement.

                          Мин. значение0
                          Инвариантыele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
                          726. Observation.component:elastographyStiffness.value[x].comparator
                          Определение

                          How the value should be understood and represented - whether the actual value is greater or less than the stated value due to measurement issues; e.g. if the comparator is "<" , then the real value is < stated value.

                          Короткий< | <= | >= | > | ad - how to understand the value
                          Контроль0..1
                          ПривязкаКоды ДОЛЖНЫ быть взяты из QuantityComparator
                          (required to http://hl7.org/fhir/ValueSet/quantity-comparator|5.0.0)

                          How the Quantity should be understood and represented.

                          Типcode
                          Модификаторtrue потому что This is labeled as "Is Modifier" because the comparator modifies the interpretation of the value significantly. If there is no comparator, then there is no modification of the value
                          Примитивное значениеЭтот примитивный элемент может присутствовать или отсутствовать, или быть замененным расширением
                          Summarytrue
                          Требования

                          Need a framework for handling measures where the value is <5ug/L or >400mg/L due to the limitations of measuring methodology.

                          Значение при отсутствииIf there is no comparator, then there is no modification of the value
                          Инвариантыele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
                          728. Observation.component:elastographyStiffness.value[x].unit
                          Определение

                          A human-readable form of the unit.

                          КороткийUnit representation
                          Контроль1..1
                          Типstring
                          Модификаторfalse
                          Примитивное значениеЭтот примитивный элемент может присутствовать или отсутствовать, или быть замененным расширением
                          Summarytrue
                          Требования

                          There are many representations for units of measure and in many contexts, particular representations are fixed and required. I.e. mcg for micrograms.

                          Инвариантыele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
                          730. Observation.component:elastographyStiffness.value[x].system
                          Определение

                          The identification of the system that provides the coded form of the unit.

                          КороткийSystem that defines coded unit form
                          Контроль1..1
                          На этот элемент влияют следующие инварианты: qty-3
                          Типuri
                          Модификаторfalse
                          Примитивное значениеЭтот примитивный элемент может присутствовать или отсутствовать, или быть замененным расширением
                          Summarytrue
                          Требования

                          Need to know the system that defines the coded form of the unit.

                          Инвариантыele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
                          732. Observation.component:elastographyStiffness.value[x].code
                          Определение

                          A computer processable form of the unit in some unit representation system.

                          КороткийCoded form of the unit
                          Комментарии

                          The preferred system is UCUM, but SNOMED CT can also be used (for customary units) or ISO 4217 for currency. The context of use may additionally require a code from a particular system.

                          Контроль1..1
                          На этот элемент влияют следующие инварианты: qty-3
                          Типcode
                          Модификаторfalse
                          Примитивное значениеЭтот примитивный элемент может присутствовать или отсутствовать, или быть замененным расширением
                          Summarytrue
                          Требования

                          Need a computable form of the unit that is fixed across all forms. UCUM provides this for quantities, but SNOMED CT provides many units of interest.

                          Инвариантыele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
                          734. Observation.component:elastographyStiffness.dataAbsentReason
                          Определение

                          Provides a reason why the expected value in the element Observation.component.value[x] is missing.

                          КороткийWhy the component result is missing
                          Комментарии

                          "Null" or exceptional values can be represented two ways in FHIR Observations. One way is to simply include them in the value set and represent the exceptions in the value. For example, measurement values for a serology test could be "detected", "not detected", "inconclusive", or "test not done".

                          The alternate way is to use the value element for actual observations and use the explicit dataAbsentReason element to record exceptional values. For example, the dataAbsentReason code "error" could be used when the measurement was not completed. Because of these options, use-case agreements are required to interpret general observations for exceptional values.

                          Контроль0..1
                          ПривязкаЕсли они не подходят, эти коды ДОЛЖНЫ быть взяты из DataAbsentReasonVS (0.12.0)
                          (extensible to https://terminology.dhp.uz/fhir/core/ValueSet/data-absent-reason-vs|0.12.0)
                          ТипCodeableConcept
                          Модификаторfalse
                          Требуется поддержкаfalse
                          Summaryfalse
                          Требования

                          For many results it is necessary to handle exceptional values in measurements.

                          Инвариантыele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
                          736. Observation.component:elastographyStiffness.interpretation
                          Определение

                          A categorical assessment of an observation value. For example, high, low, normal.

                          КороткийHigh, low, normal, etc
                          Комментарии

                          Historically used for laboratory results (known as 'abnormal flag' ), its use extends to other use cases where coded interpretations are relevant. Often reported as one or more simple compact codes this element is often placed adjacent to the result value in reports and flow sheets to signal the meaning/normalcy status of the result.

                          Контроль0..*
                          ПривязкаЕсли они не подходят, эти коды ДОЛЖНЫ быть взяты из ObservationInterpretationVS (0.12.0)
                          (extensible to https://terminology.dhp.uz/fhir/core/ValueSet/observation-interpretation-vs|0.12.0)
                          ТипCodeableConcept
                          Модификаторfalse
                          Требуется поддержкаfalse
                          Summaryfalse
                          Требования

                          For some results, particularly numeric results, an interpretation is necessary to fully understand the significance of a result.

                          Альтернативные именаAbnormal Flag
                          Инвариантыele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
                          738. Observation.component:elastographyStiffness.referenceRange
                          Определение

                          Guidance on how to interpret the value by comparison to a normal or recommended range.

                          КороткийProvides guide for interpretation of component result
                          Комментарии

                          Most observations only have one generic reference range. Systems MAY choose to restrict to only supplying the relevant reference range based on knowledge about the patient (e.g., specific to the patient's age, gender, weight and other factors), but this might not be possible or appropriate. Whenever more than one reference range is supplied, the differences between them SHOULD be provided in the reference range and/or age properties.

                          Контроль0..*
                          ТипСмотретьttp://hl7.org/fhir/StructureDefinition/Observation#Observation.referenceRange
                          Модификаторfalse
                          Требуется поддержкаfalse
                          Summaryfalse
                          Требования

                          Knowing what values are considered "normal" can help evaluate the significance of a particular result. Need to be able to provide multiple reference ranges for different contexts.

                          Инвариантыele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
                          740. Observation.component:axillaryMaximumNodeSize
                          Название разрезаaxillaryMaximumNodeSize
                          Определение

                          Some observations have multiple component observations. These component observations are expressed as separate code value pairs that share the same attributes. Examples include systolic and diastolic component observations for blood pressure measurement and multiple component observations for genetics observations.

                          КороткийMaximum axillary lymph node size
                          Комментарии

                          For a discussion on the ways Observations can be assembled in groups together see Notes below.

                          Контроль0..1
                          На этот элемент влияют следующие инварианты: obs-7
                          ТипBackboneElement
                          Модификаторfalse
                          Требуется поддержкаtrue
                          Summarytrue
                          Требования

                          Component observations share the same attributes in the Observation resource as the primary observation and are always treated a part of a single observation (they are not separable). However, the reference range for the primary observation value is not inherited by the component values and is required when appropriate for each component observation.

                          Инвариантыele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
                          742. Observation.component:axillaryMaximumNodeSize.id
                          Определение

                          Unique id for the element within a resource (for internal references). This may be any string value that does not contain spaces.

                          КороткийUnique id for inter-element referencing
                          Контроль0..1
                          На этот элемент влияют следующие инварианты: ele-1
                          Типstring
                          Модификаторfalse
                          Формат XMLВ формате XML это свойство представлено в качестве атрибута.
                          Summaryfalse
                          744. Observation.component:axillaryMaximumNodeSize.extension
                          Определение

                          May be used to represent additional information that is not part of the basic definition of the element. To make the use of extensions safe and managable, there is a strict set of governance applied to the definition and use of extensions. Though any implementer can define an extension, there is a set of requirements that SHALL be met as part of the definition of the extension.

                          КороткийAdditional content defined by implementations
                          Комментарии

                          There can be no stigma associated with the use of extensions by any application, project, or standard - regardless of the institution or jurisdiction that uses or defines the extensions. The use of extensions is what allows the FHIR specification to retain a core level of simplicity for everyone.

                          Контроль0..*
                          ТипExtension
                          Модификаторfalse
                          Summaryfalse
                          Альтернативные именаextensions, user content
                          Инвариантыele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
                          ext-1: Must have either extensions or value[x], not both (extension.exists() != value.exists())
                          746. Observation.component:axillaryMaximumNodeSize.modifierExtension
                          Определение

                          May be used to represent additional information that is not part of the basic definition of the element and that modifies the understanding of the element in which it is contained and/or the understanding of the containing element's descendants. Usually modifier elements provide negation or qualification. To make the use of extensions safe and managable, there is a strict set of governance applied to the definition and use of extensions. Though any implementer can define an extension, there is a set of requirements that SHALL be met as part of the definition of the extension. Applications processing a resource are required to check for modifier extensions.

                          Modifier extensions SHALL NOT change the meaning of any elements on Resource or DomainResource (including cannot change the meaning of modifierExtension itself).

                          КороткийExtensions that cannot be ignored even if unrecognized
                          Комментарии

                          There can be no stigma associated with the use of extensions by any application, project, or standard - regardless of the institution or jurisdiction that uses or defines the extensions. The use of extensions is what allows the FHIR specification to retain a core level of simplicity for everyone.

                          Контроль0..*
                          ТипExtension
                          Модификаторtrue потому что Modifier extensions are expected to modify the meaning or interpretation of the element that contains them
                          Summarytrue
                          Требования

                          Modifier extensions allow for extensions that cannot be safely ignored to be clearly distinguished from the vast majority of extensions which can be safely ignored. This promotes interoperability by eliminating the need for implementers to prohibit the presence of extensions. For further information, see the definition of modifier extensions.

                          Альтернативные именаextensions, user content, modifiers
                          Инвариантыele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
                          ext-1: Must have either extensions or value[x], not both (extension.exists() != value.exists())
                          748. Observation.component:axillaryMaximumNodeSize.code
                          Определение

                          Describes what was observed. Sometimes this is called the observation "code".

                          КороткийType of component observation (code / type)
                          Комментарии

                          All code-value and component.code-component.value pairs need to be taken into account to correctly understand the meaning of the observation.

                          Контроль1..1
                          На этот элемент влияют следующие инварианты: obs-7
                          ПривязкаКоды СЛЕДУЕТ взять из ObservationCodesVS (0.12.0)
                          (preferred to https://terminology.dhp.uz/fhir/core/ValueSet/observation-codes-vs|0.12.0)
                          ТипCodeableConcept
                          Модификаторfalse
                          Требуется поддержкаtrue
                          Summarytrue
                          Требования

                          Knowing what kind of observation is being made is essential to understanding the observation.

                          Значение шаблона{
                            "coding" : [{
                              "system" : "https://terminology.dhp.uz/fhir/integrations/CodeSystem/screening-ultrasound-parameter-cs",
                              "code" : "scrn-0052-00038"
                            }]
                          }
                          Инвариантыele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
                          750. Observation.component:axillaryMaximumNodeSize.value[x]
                          Определение

                          The information determined as a result of making the observation, if the information has a simple value.

                          КороткийActual component result
                          Комментарии

                          Used when observation has a set of component observations:

                          • An observation may have both a value (e.g. an Apgar score) and component observations (the observations from which the Apgar score was derived).
                          • If a value is present, the datatype for this element should be determined by the code.
                          • CodeableConcept with just a text would be used instead of a string if the field was usually coded, or if the type associated with the code defines a coded value.
                          • Attachment is used if the observation result value is a binary file such as an image. If the observation result value is derived from the binary file (for example 'X' detected and here is the the proof in this image), the binary file may be directly represented using DocumentReference and referenced by derivedFrom.
                          • If a value is present, the datatype for this element should be determined by the code.
                          • CodeableConcept with just a text would be used instead of a string if the field was usually coded, or if the type associated with the code defines a coded value.
                          • Attachment is used if the observation result value is a binary file such as an image. If the observation result value is derived from the binary file (for example 'X' detected and here is the the proof in this image), the binary file may be directly represented using DocumentReference and referenced by derivedFrom.
                          • The usage of valueReference is restricted to the MolecularSequence resource when used as a definitional resource, not as a patient-specific finding. .
                          • For additional guidance, see the Notes section below.
                          Контроль1..1
                          ТипQuantity
                          [x] ЗаметкаСмотретьВыбор типов данныхдля дополнительной информации о том, как использовать [x]
                          Модификаторfalse
                          Требуется поддержкаtrue
                          Summarytrue
                          Требования

                          An observation exists to have a value, though it might not if it is in error, or if it represents a group of observations.

                          Значение шаблона{
                            "unit" : "mm",
                            "system" : "http://unitsofmeasure.org",
                            "code" : "mm"
                          }
                          Инвариантыele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
                          752. Observation.component:axillaryMaximumNodeSize.value[x].id
                          Определение

                          Unique id for the element within a resource (for internal references). This may be any string value that does not contain spaces.

                          КороткийUnique id for inter-element referencing
                          Контроль0..1
                          На этот элемент влияют следующие инварианты: ele-1
                          Типid
                          Модификаторfalse
                          Формат XMLВ формате XML это свойство представлено в качестве атрибута.
                          Summaryfalse
                          754. Observation.component:axillaryMaximumNodeSize.value[x].extension
                          Определение

                          May be used to represent additional information that is not part of the basic definition of the element. To make the use of extensions safe and managable, there is a strict set of governance applied to the definition and use of extensions. Though any implementer can define an extension, there is a set of requirements that SHALL be met as part of the definition of the extension.

                          КороткийAdditional content defined by implementations
                          Комментарии

                          There can be no stigma associated with the use of extensions by any application, project, or standard - regardless of the institution or jurisdiction that uses or defines the extensions. The use of extensions is what allows the FHIR specification to retain a core level of simplicity for everyone.

                          Контроль0..*
                          ТипExtension
                          Модификаторfalse
                          Summaryfalse
                          Альтернативные именаextensions, user content
                          Инвариантыele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
                          ext-1: Must have either extensions or value[x], not both (extension.exists() != value.exists())
                          SlicingЭтот элемент представляет набор разрезов на Observation.component.value[x].extension. Разрезы бываютНе упорядочено и Open, и могут быть дифференцированы с помощью следующих дискриминаторов:
                          • value @ url
                          • 756. Observation.component:axillaryMaximumNodeSize.value[x].value
                            Определение

                            The value of the measured amount. The value includes an implicit precision in the presentation of the value.

                            КороткийNumerical value (with implicit precision)
                            Комментарии

                            The implicit precision in the value should always be honored. Monetary values have their own rules for handling precision (refer to standard accounting text books).

                            Контроль1..1
                            Типdecimal
                            Модификаторfalse
                            Примитивное значениеЭтот примитивный элемент может присутствовать или отсутствовать, или быть замененным расширением
                            Summarytrue
                            Требования

                            Precision is handled implicitly in almost all cases of measurement.

                            Мин. значение0
                            Инвариантыele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
                            758. Observation.component:axillaryMaximumNodeSize.value[x].comparator
                            Определение

                            How the value should be understood and represented - whether the actual value is greater or less than the stated value due to measurement issues; e.g. if the comparator is "<" , then the real value is < stated value.

                            Короткий< | <= | >= | > | ad - how to understand the value
                            Контроль0..1
                            ПривязкаКоды ДОЛЖНЫ быть взяты из QuantityComparator
                            (required to http://hl7.org/fhir/ValueSet/quantity-comparator|5.0.0)

                            How the Quantity should be understood and represented.

                            Типcode
                            Модификаторtrue потому что This is labeled as "Is Modifier" because the comparator modifies the interpretation of the value significantly. If there is no comparator, then there is no modification of the value
                            Примитивное значениеЭтот примитивный элемент может присутствовать или отсутствовать, или быть замененным расширением
                            Summarytrue
                            Требования

                            Need a framework for handling measures where the value is <5ug/L or >400mg/L due to the limitations of measuring methodology.

                            Значение при отсутствииIf there is no comparator, then there is no modification of the value
                            Инвариантыele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
                            760. Observation.component:axillaryMaximumNodeSize.value[x].unit
                            Определение

                            A human-readable form of the unit.

                            КороткийUnit representation
                            Контроль1..1
                            Типstring
                            Модификаторfalse
                            Примитивное значениеЭтот примитивный элемент может присутствовать или отсутствовать, или быть замененным расширением
                            Summarytrue
                            Требования

                            There are many representations for units of measure and in many contexts, particular representations are fixed and required. I.e. mcg for micrograms.

                            Инвариантыele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
                            762. Observation.component:axillaryMaximumNodeSize.value[x].system
                            Определение

                            The identification of the system that provides the coded form of the unit.

                            КороткийSystem that defines coded unit form
                            Контроль1..1
                            На этот элемент влияют следующие инварианты: qty-3
                            Типuri
                            Модификаторfalse
                            Примитивное значениеЭтот примитивный элемент может присутствовать или отсутствовать, или быть замененным расширением
                            Summarytrue
                            Требования

                            Need to know the system that defines the coded form of the unit.

                            Инвариантыele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
                            764. Observation.component:axillaryMaximumNodeSize.value[x].code
                            Определение

                            A computer processable form of the unit in some unit representation system.

                            КороткийCoded form of the unit
                            Комментарии

                            The preferred system is UCUM, but SNOMED CT can also be used (for customary units) or ISO 4217 for currency. The context of use may additionally require a code from a particular system.

                            Контроль1..1
                            На этот элемент влияют следующие инварианты: qty-3
                            Типcode
                            Модификаторfalse
                            Примитивное значениеЭтот примитивный элемент может присутствовать или отсутствовать, или быть замененным расширением
                            Summarytrue
                            Требования

                            Need a computable form of the unit that is fixed across all forms. UCUM provides this for quantities, but SNOMED CT provides many units of interest.

                            Инвариантыele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
                            766. Observation.component:axillaryMaximumNodeSize.dataAbsentReason
                            Определение

                            Provides a reason why the expected value in the element Observation.component.value[x] is missing.

                            КороткийWhy the component result is missing
                            Комментарии

                            "Null" or exceptional values can be represented two ways in FHIR Observations. One way is to simply include them in the value set and represent the exceptions in the value. For example, measurement values for a serology test could be "detected", "not detected", "inconclusive", or "test not done".

                            The alternate way is to use the value element for actual observations and use the explicit dataAbsentReason element to record exceptional values. For example, the dataAbsentReason code "error" could be used when the measurement was not completed. Because of these options, use-case agreements are required to interpret general observations for exceptional values.

                            Контроль0..1
                            ПривязкаЕсли они не подходят, эти коды ДОЛЖНЫ быть взяты из DataAbsentReasonVS (0.12.0)
                            (extensible to https://terminology.dhp.uz/fhir/core/ValueSet/data-absent-reason-vs|0.12.0)
                            ТипCodeableConcept
                            Модификаторfalse
                            Требуется поддержкаfalse
                            Summaryfalse
                            Требования

                            For many results it is necessary to handle exceptional values in measurements.

                            Инвариантыele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
                            768. Observation.component:axillaryMaximumNodeSize.interpretation
                            Определение

                            A categorical assessment of an observation value. For example, high, low, normal.

                            КороткийHigh, low, normal, etc
                            Комментарии

                            Historically used for laboratory results (known as 'abnormal flag' ), its use extends to other use cases where coded interpretations are relevant. Often reported as one or more simple compact codes this element is often placed adjacent to the result value in reports and flow sheets to signal the meaning/normalcy status of the result.

                            Контроль0..*
                            ПривязкаЕсли они не подходят, эти коды ДОЛЖНЫ быть взяты из ObservationInterpretationVS (0.12.0)
                            (extensible to https://terminology.dhp.uz/fhir/core/ValueSet/observation-interpretation-vs|0.12.0)
                            ТипCodeableConcept
                            Модификаторfalse
                            Требуется поддержкаfalse
                            Summaryfalse
                            Требования

                            For some results, particularly numeric results, an interpretation is necessary to fully understand the significance of a result.

                            Альтернативные именаAbnormal Flag
                            Инвариантыele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
                            770. Observation.component:axillaryMaximumNodeSize.referenceRange
                            Определение

                            Guidance on how to interpret the value by comparison to a normal or recommended range.

                            КороткийProvides guide for interpretation of component result
                            Комментарии

                            Most observations only have one generic reference range. Systems MAY choose to restrict to only supplying the relevant reference range based on knowledge about the patient (e.g., specific to the patient's age, gender, weight and other factors), but this might not be possible or appropriate. Whenever more than one reference range is supplied, the differences between them SHOULD be provided in the reference range and/or age properties.

                            Контроль0..*
                            ТипСмотретьttp://hl7.org/fhir/StructureDefinition/Observation#Observation.referenceRange
                            Модификаторfalse
                            Требуется поддержкаfalse
                            Summaryfalse
                            Требования

                            Knowing what values are considered "normal" can help evaluate the significance of a particular result. Need to be able to provide multiple reference ranges for different contexts.

                            Инвариантыele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
                            772. Observation.component:axillaryCorticalThickness
                            Название разрезаaxillaryCorticalThickness
                            Определение

                            Some observations have multiple component observations. These component observations are expressed as separate code value pairs that share the same attributes. Examples include systolic and diastolic component observations for blood pressure measurement and multiple component observations for genetics observations.

                            КороткийAxillary lymph node cortical thickness
                            Комментарии

                            For a discussion on the ways Observations can be assembled in groups together see Notes below.

                            Контроль0..1
                            На этот элемент влияют следующие инварианты: obs-7
                            ТипBackboneElement
                            Модификаторfalse
                            Требуется поддержкаtrue
                            Summarytrue
                            Требования

                            Component observations share the same attributes in the Observation resource as the primary observation and are always treated a part of a single observation (they are not separable). However, the reference range for the primary observation value is not inherited by the component values and is required when appropriate for each component observation.

                            Инвариантыele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
                            774. Observation.component:axillaryCorticalThickness.id
                            Определение

                            Unique id for the element within a resource (for internal references). This may be any string value that does not contain spaces.

                            КороткийUnique id for inter-element referencing
                            Контроль0..1
                            На этот элемент влияют следующие инварианты: ele-1
                            Типstring
                            Модификаторfalse
                            Формат XMLВ формате XML это свойство представлено в качестве атрибута.
                            Summaryfalse
                            776. Observation.component:axillaryCorticalThickness.extension
                            Определение

                            May be used to represent additional information that is not part of the basic definition of the element. To make the use of extensions safe and managable, there is a strict set of governance applied to the definition and use of extensions. Though any implementer can define an extension, there is a set of requirements that SHALL be met as part of the definition of the extension.

                            КороткийAdditional content defined by implementations
                            Комментарии

                            There can be no stigma associated with the use of extensions by any application, project, or standard - regardless of the institution or jurisdiction that uses or defines the extensions. The use of extensions is what allows the FHIR specification to retain a core level of simplicity for everyone.

                            Контроль0..*
                            ТипExtension
                            Модификаторfalse
                            Summaryfalse
                            Альтернативные именаextensions, user content
                            Инвариантыele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
                            ext-1: Must have either extensions or value[x], not both (extension.exists() != value.exists())
                            778. Observation.component:axillaryCorticalThickness.modifierExtension
                            Определение

                            May be used to represent additional information that is not part of the basic definition of the element and that modifies the understanding of the element in which it is contained and/or the understanding of the containing element's descendants. Usually modifier elements provide negation or qualification. To make the use of extensions safe and managable, there is a strict set of governance applied to the definition and use of extensions. Though any implementer can define an extension, there is a set of requirements that SHALL be met as part of the definition of the extension. Applications processing a resource are required to check for modifier extensions.

                            Modifier extensions SHALL NOT change the meaning of any elements on Resource or DomainResource (including cannot change the meaning of modifierExtension itself).

                            КороткийExtensions that cannot be ignored even if unrecognized
                            Комментарии

                            There can be no stigma associated with the use of extensions by any application, project, or standard - regardless of the institution or jurisdiction that uses or defines the extensions. The use of extensions is what allows the FHIR specification to retain a core level of simplicity for everyone.

                            Контроль0..*
                            ТипExtension
                            Модификаторtrue потому что Modifier extensions are expected to modify the meaning or interpretation of the element that contains them
                            Summarytrue
                            Требования

                            Modifier extensions allow for extensions that cannot be safely ignored to be clearly distinguished from the vast majority of extensions which can be safely ignored. This promotes interoperability by eliminating the need for implementers to prohibit the presence of extensions. For further information, see the definition of modifier extensions.

                            Альтернативные именаextensions, user content, modifiers
                            Инвариантыele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
                            ext-1: Must have either extensions or value[x], not both (extension.exists() != value.exists())
                            780. Observation.component:axillaryCorticalThickness.code
                            Определение

                            Describes what was observed. Sometimes this is called the observation "code".

                            КороткийType of component observation (code / type)
                            Комментарии

                            All code-value and component.code-component.value pairs need to be taken into account to correctly understand the meaning of the observation.

                            Контроль1..1
                            На этот элемент влияют следующие инварианты: obs-7
                            ПривязкаКоды СЛЕДУЕТ взять из ObservationCodesVS (0.12.0)
                            (preferred to https://terminology.dhp.uz/fhir/core/ValueSet/observation-codes-vs|0.12.0)
                            ТипCodeableConcept
                            Модификаторfalse
                            Требуется поддержкаtrue
                            Summarytrue
                            Требования

                            Knowing what kind of observation is being made is essential to understanding the observation.

                            Значение шаблона{
                              "coding" : [{
                                "system" : "https://terminology.dhp.uz/fhir/integrations/CodeSystem/screening-ultrasound-parameter-cs",
                                "code" : "scrn-0052-00039"
                              }]
                            }
                            Инвариантыele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
                            782. Observation.component:axillaryCorticalThickness.value[x]
                            Определение

                            The information determined as a result of making the observation, if the information has a simple value.

                            КороткийActual component result
                            Комментарии

                            Used when observation has a set of component observations:

                            • An observation may have both a value (e.g. an Apgar score) and component observations (the observations from which the Apgar score was derived).
                            • If a value is present, the datatype for this element should be determined by the code.
                            • CodeableConcept with just a text would be used instead of a string if the field was usually coded, or if the type associated with the code defines a coded value.
                            • Attachment is used if the observation result value is a binary file such as an image. If the observation result value is derived from the binary file (for example 'X' detected and here is the the proof in this image), the binary file may be directly represented using DocumentReference and referenced by derivedFrom.
                            • If a value is present, the datatype for this element should be determined by the code.
                            • CodeableConcept with just a text would be used instead of a string if the field was usually coded, or if the type associated with the code defines a coded value.
                            • Attachment is used if the observation result value is a binary file such as an image. If the observation result value is derived from the binary file (for example 'X' detected and here is the the proof in this image), the binary file may be directly represented using DocumentReference and referenced by derivedFrom.
                            • The usage of valueReference is restricted to the MolecularSequence resource when used as a definitional resource, not as a patient-specific finding. .
                            • For additional guidance, see the Notes section below.
                            Контроль1..1
                            ТипQuantity
                            [x] ЗаметкаСмотретьВыбор типов данныхдля дополнительной информации о том, как использовать [x]
                            Модификаторfalse
                            Требуется поддержкаtrue
                            Summarytrue
                            Требования

                            An observation exists to have a value, though it might not if it is in error, or if it represents a group of observations.

                            Значение шаблона{
                              "unit" : "mm",
                              "system" : "http://unitsofmeasure.org",
                              "code" : "mm"
                            }
                            Инвариантыele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
                            784. Observation.component:axillaryCorticalThickness.value[x].id
                            Определение

                            Unique id for the element within a resource (for internal references). This may be any string value that does not contain spaces.

                            КороткийUnique id for inter-element referencing
                            Контроль0..1
                            На этот элемент влияют следующие инварианты: ele-1
                            Типid
                            Модификаторfalse
                            Формат XMLВ формате XML это свойство представлено в качестве атрибута.
                            Summaryfalse
                            786. Observation.component:axillaryCorticalThickness.value[x].extension
                            Определение

                            May be used to represent additional information that is not part of the basic definition of the element. To make the use of extensions safe and managable, there is a strict set of governance applied to the definition and use of extensions. Though any implementer can define an extension, there is a set of requirements that SHALL be met as part of the definition of the extension.

                            КороткийAdditional content defined by implementations
                            Комментарии

                            There can be no stigma associated with the use of extensions by any application, project, or standard - regardless of the institution or jurisdiction that uses or defines the extensions. The use of extensions is what allows the FHIR specification to retain a core level of simplicity for everyone.

                            Контроль0..*
                            ТипExtension
                            Модификаторfalse
                            Summaryfalse
                            Альтернативные именаextensions, user content
                            Инвариантыele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
                            ext-1: Must have either extensions or value[x], not both (extension.exists() != value.exists())
                            SlicingЭтот элемент представляет набор разрезов на Observation.component.value[x].extension. Разрезы бываютНе упорядочено и Open, и могут быть дифференцированы с помощью следующих дискриминаторов:
                            • value @ url
                            • 788. Observation.component:axillaryCorticalThickness.value[x].value
                              Определение

                              The value of the measured amount. The value includes an implicit precision in the presentation of the value.

                              КороткийNumerical value (with implicit precision)
                              Комментарии

                              The implicit precision in the value should always be honored. Monetary values have their own rules for handling precision (refer to standard accounting text books).

                              Контроль1..1
                              Типdecimal
                              Модификаторfalse
                              Примитивное значениеЭтот примитивный элемент может присутствовать или отсутствовать, или быть замененным расширением
                              Summarytrue
                              Требования

                              Precision is handled implicitly in almost all cases of measurement.

                              Мин. значение0
                              Инвариантыele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
                              790. Observation.component:axillaryCorticalThickness.value[x].comparator
                              Определение

                              How the value should be understood and represented - whether the actual value is greater or less than the stated value due to measurement issues; e.g. if the comparator is "<" , then the real value is < stated value.

                              Короткий< | <= | >= | > | ad - how to understand the value
                              Контроль0..1
                              ПривязкаКоды ДОЛЖНЫ быть взяты из QuantityComparator
                              (required to http://hl7.org/fhir/ValueSet/quantity-comparator|5.0.0)

                              How the Quantity should be understood and represented.

                              Типcode
                              Модификаторtrue потому что This is labeled as "Is Modifier" because the comparator modifies the interpretation of the value significantly. If there is no comparator, then there is no modification of the value
                              Примитивное значениеЭтот примитивный элемент может присутствовать или отсутствовать, или быть замененным расширением
                              Summarytrue
                              Требования

                              Need a framework for handling measures where the value is <5ug/L or >400mg/L due to the limitations of measuring methodology.

                              Значение при отсутствииIf there is no comparator, then there is no modification of the value
                              Инвариантыele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
                              792. Observation.component:axillaryCorticalThickness.value[x].unit
                              Определение

                              A human-readable form of the unit.

                              КороткийUnit representation
                              Контроль1..1
                              Типstring
                              Модификаторfalse
                              Примитивное значениеЭтот примитивный элемент может присутствовать или отсутствовать, или быть замененным расширением
                              Summarytrue
                              Требования

                              There are many representations for units of measure and in many contexts, particular representations are fixed and required. I.e. mcg for micrograms.

                              Инвариантыele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
                              794. Observation.component:axillaryCorticalThickness.value[x].system
                              Определение

                              The identification of the system that provides the coded form of the unit.

                              КороткийSystem that defines coded unit form
                              Контроль1..1
                              На этот элемент влияют следующие инварианты: qty-3
                              Типuri
                              Модификаторfalse
                              Примитивное значениеЭтот примитивный элемент может присутствовать или отсутствовать, или быть замененным расширением
                              Summarytrue
                              Требования

                              Need to know the system that defines the coded form of the unit.

                              Инвариантыele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
                              796. Observation.component:axillaryCorticalThickness.value[x].code
                              Определение

                              A computer processable form of the unit in some unit representation system.

                              КороткийCoded form of the unit
                              Комментарии

                              The preferred system is UCUM, but SNOMED CT can also be used (for customary units) or ISO 4217 for currency. The context of use may additionally require a code from a particular system.

                              Контроль1..1
                              На этот элемент влияют следующие инварианты: qty-3
                              Типcode
                              Модификаторfalse
                              Примитивное значениеЭтот примитивный элемент может присутствовать или отсутствовать, или быть замененным расширением
                              Summarytrue
                              Требования

                              Need a computable form of the unit that is fixed across all forms. UCUM provides this for quantities, but SNOMED CT provides many units of interest.

                              Инвариантыele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
                              798. Observation.component:axillaryCorticalThickness.dataAbsentReason
                              Определение

                              Provides a reason why the expected value in the element Observation.component.value[x] is missing.

                              КороткийWhy the component result is missing
                              Комментарии

                              "Null" or exceptional values can be represented two ways in FHIR Observations. One way is to simply include them in the value set and represent the exceptions in the value. For example, measurement values for a serology test could be "detected", "not detected", "inconclusive", or "test not done".

                              The alternate way is to use the value element for actual observations and use the explicit dataAbsentReason element to record exceptional values. For example, the dataAbsentReason code "error" could be used when the measurement was not completed. Because of these options, use-case agreements are required to interpret general observations for exceptional values.

                              Контроль0..1
                              ПривязкаЕсли они не подходят, эти коды ДОЛЖНЫ быть взяты из DataAbsentReasonVS (0.12.0)
                              (extensible to https://terminology.dhp.uz/fhir/core/ValueSet/data-absent-reason-vs|0.12.0)
                              ТипCodeableConcept
                              Модификаторfalse
                              Требуется поддержкаfalse
                              Summaryfalse
                              Требования

                              For many results it is necessary to handle exceptional values in measurements.

                              Инвариантыele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
                              800. Observation.component:axillaryCorticalThickness.interpretation
                              Определение

                              A categorical assessment of an observation value. For example, high, low, normal.

                              КороткийHigh, low, normal, etc
                              Комментарии

                              Historically used for laboratory results (known as 'abnormal flag' ), its use extends to other use cases where coded interpretations are relevant. Often reported as one or more simple compact codes this element is often placed adjacent to the result value in reports and flow sheets to signal the meaning/normalcy status of the result.

                              Контроль0..*
                              ПривязкаЕсли они не подходят, эти коды ДОЛЖНЫ быть взяты из ObservationInterpretationVS (0.12.0)
                              (extensible to https://terminology.dhp.uz/fhir/core/ValueSet/observation-interpretation-vs|0.12.0)
                              ТипCodeableConcept
                              Модификаторfalse
                              Требуется поддержкаfalse
                              Summaryfalse
                              Требования

                              For some results, particularly numeric results, an interpretation is necessary to fully understand the significance of a result.

                              Альтернативные именаAbnormal Flag
                              Инвариантыele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
                              802. Observation.component:axillaryCorticalThickness.referenceRange
                              Определение

                              Guidance on how to interpret the value by comparison to a normal or recommended range.

                              КороткийProvides guide for interpretation of component result
                              Комментарии

                              Most observations only have one generic reference range. Systems MAY choose to restrict to only supplying the relevant reference range based on knowledge about the patient (e.g., specific to the patient's age, gender, weight and other factors), but this might not be possible or appropriate. Whenever more than one reference range is supplied, the differences between them SHOULD be provided in the reference range and/or age properties.

                              Контроль0..*
                              ТипСмотретьttp://hl7.org/fhir/StructureDefinition/Observation#Observation.referenceRange
                              Модификаторfalse
                              Требуется поддержкаfalse
                              Summaryfalse
                              Требования

                              Knowing what values are considered "normal" can help evaluate the significance of a particular result. Need to be able to provide multiple reference ranges for different contexts.

                              Инвариантыele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
                              804. Observation.component:regionalNodeNote
                              Название разрезаregionalNodeNote
                              Определение

                              Some observations have multiple component observations. These component observations are expressed as separate code value pairs that share the same attributes. Examples include systolic and diastolic component observations for blood pressure measurement and multiple component observations for genetics observations.

                              КороткийComment about other regional lymph nodes
                              Комментарии

                              For a discussion on the ways Observations can be assembled in groups together see Notes below.

                              Контроль0..1
                              На этот элемент влияют следующие инварианты: obs-7
                              ТипBackboneElement
                              Модификаторfalse
                              Требуется поддержкаtrue
                              Summarytrue
                              Требования

                              Component observations share the same attributes in the Observation resource as the primary observation and are always treated a part of a single observation (they are not separable). However, the reference range for the primary observation value is not inherited by the component values and is required when appropriate for each component observation.

                              Инвариантыele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
                              806. Observation.component:regionalNodeNote.id
                              Определение

                              Unique id for the element within a resource (for internal references). This may be any string value that does not contain spaces.

                              КороткийUnique id for inter-element referencing
                              Контроль0..1
                              На этот элемент влияют следующие инварианты: ele-1
                              Типstring
                              Модификаторfalse
                              Формат XMLВ формате XML это свойство представлено в качестве атрибута.
                              Summaryfalse
                              808. Observation.component:regionalNodeNote.extension
                              Определение

                              May be used to represent additional information that is not part of the basic definition of the element. To make the use of extensions safe and managable, there is a strict set of governance applied to the definition and use of extensions. Though any implementer can define an extension, there is a set of requirements that SHALL be met as part of the definition of the extension.

                              КороткийAdditional content defined by implementations
                              Комментарии

                              There can be no stigma associated with the use of extensions by any application, project, or standard - regardless of the institution or jurisdiction that uses or defines the extensions. The use of extensions is what allows the FHIR specification to retain a core level of simplicity for everyone.

                              Контроль0..*
                              ТипExtension
                              Модификаторfalse
                              Summaryfalse
                              Альтернативные именаextensions, user content
                              Инвариантыele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
                              ext-1: Must have either extensions or value[x], not both (extension.exists() != value.exists())
                              810. Observation.component:regionalNodeNote.modifierExtension
                              Определение

                              May be used to represent additional information that is not part of the basic definition of the element and that modifies the understanding of the element in which it is contained and/or the understanding of the containing element's descendants. Usually modifier elements provide negation or qualification. To make the use of extensions safe and managable, there is a strict set of governance applied to the definition and use of extensions. Though any implementer can define an extension, there is a set of requirements that SHALL be met as part of the definition of the extension. Applications processing a resource are required to check for modifier extensions.

                              Modifier extensions SHALL NOT change the meaning of any elements on Resource or DomainResource (including cannot change the meaning of modifierExtension itself).

                              КороткийExtensions that cannot be ignored even if unrecognized
                              Комментарии

                              There can be no stigma associated with the use of extensions by any application, project, or standard - regardless of the institution or jurisdiction that uses or defines the extensions. The use of extensions is what allows the FHIR specification to retain a core level of simplicity for everyone.

                              Контроль0..*
                              ТипExtension
                              Модификаторtrue потому что Modifier extensions are expected to modify the meaning or interpretation of the element that contains them
                              Summarytrue
                              Требования

                              Modifier extensions allow for extensions that cannot be safely ignored to be clearly distinguished from the vast majority of extensions which can be safely ignored. This promotes interoperability by eliminating the need for implementers to prohibit the presence of extensions. For further information, see the definition of modifier extensions.

                              Альтернативные именаextensions, user content, modifiers
                              Инвариантыele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
                              ext-1: Must have either extensions or value[x], not both (extension.exists() != value.exists())
                              812. Observation.component:regionalNodeNote.code
                              Определение

                              Describes what was observed. Sometimes this is called the observation "code".

                              КороткийType of component observation (code / type)
                              Комментарии

                              All code-value and component.code-component.value pairs need to be taken into account to correctly understand the meaning of the observation.

                              Контроль1..1
                              На этот элемент влияют следующие инварианты: obs-7
                              ПривязкаКоды СЛЕДУЕТ взять из ObservationCodesVS (0.12.0)
                              (preferred to https://terminology.dhp.uz/fhir/core/ValueSet/observation-codes-vs|0.12.0)
                              ТипCodeableConcept
                              Модификаторfalse
                              Требуется поддержкаtrue
                              Summarytrue
                              Требования

                              Knowing what kind of observation is being made is essential to understanding the observation.

                              Значение шаблона{
                                "coding" : [{
                                  "system" : "https://terminology.dhp.uz/fhir/integrations/CodeSystem/screening-ultrasound-parameter-cs",
                                  "code" : "scrn-0052-00040"
                                }]
                              }
                              Инвариантыele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
                              814. Observation.component:regionalNodeNote.value[x]
                              Определение

                              The information determined as a result of making the observation, if the information has a simple value.

                              КороткийActual component result
                              Комментарии

                              Used when observation has a set of component observations:

                              • An observation may have both a value (e.g. an Apgar score) and component observations (the observations from which the Apgar score was derived).
                              • If a value is present, the datatype for this element should be determined by the code.
                              • CodeableConcept with just a text would be used instead of a string if the field was usually coded, or if the type associated with the code defines a coded value.
                              • Attachment is used if the observation result value is a binary file such as an image. If the observation result value is derived from the binary file (for example 'X' detected and here is the the proof in this image), the binary file may be directly represented using DocumentReference and referenced by derivedFrom.
                              • If a value is present, the datatype for this element should be determined by the code.
                              • CodeableConcept with just a text would be used instead of a string if the field was usually coded, or if the type associated with the code defines a coded value.
                              • Attachment is used if the observation result value is a binary file such as an image. If the observation result value is derived from the binary file (for example 'X' detected and here is the the proof in this image), the binary file may be directly represented using DocumentReference and referenced by derivedFrom.
                              • The usage of valueReference is restricted to the MolecularSequence resource when used as a definitional resource, not as a patient-specific finding. .
                              • For additional guidance, see the Notes section below.
                              Контроль1..1
                              Типstring
                              [x] ЗаметкаСмотретьВыбор типов данныхдля дополнительной информации о том, как использовать [x]
                              Модификаторfalse
                              Примитивное значениеЭтот примитивный элемент может присутствовать или отсутствовать, или быть замененным расширением
                              Требуется поддержкаtrue
                              Summarytrue
                              Требования

                              An observation exists to have a value, though it might not if it is in error, or if it represents a group of observations.

                              Инвариантыele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
                              816. Observation.component:regionalNodeNote.dataAbsentReason
                              Определение

                              Provides a reason why the expected value in the element Observation.component.value[x] is missing.

                              КороткийWhy the component result is missing
                              Комментарии

                              "Null" or exceptional values can be represented two ways in FHIR Observations. One way is to simply include them in the value set and represent the exceptions in the value. For example, measurement values for a serology test could be "detected", "not detected", "inconclusive", or "test not done".

                              The alternate way is to use the value element for actual observations and use the explicit dataAbsentReason element to record exceptional values. For example, the dataAbsentReason code "error" could be used when the measurement was not completed. Because of these options, use-case agreements are required to interpret general observations for exceptional values.

                              Контроль0..1
                              ПривязкаЕсли они не подходят, эти коды ДОЛЖНЫ быть взяты из DataAbsentReasonVS (0.12.0)
                              (extensible to https://terminology.dhp.uz/fhir/core/ValueSet/data-absent-reason-vs|0.12.0)
                              ТипCodeableConcept
                              Модификаторfalse
                              Требуется поддержкаfalse
                              Summaryfalse
                              Требования

                              For many results it is necessary to handle exceptional values in measurements.

                              Инвариантыele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
                              818. Observation.component:regionalNodeNote.interpretation
                              Определение

                              A categorical assessment of an observation value. For example, high, low, normal.

                              КороткийHigh, low, normal, etc
                              Комментарии

                              Historically used for laboratory results (known as 'abnormal flag' ), its use extends to other use cases where coded interpretations are relevant. Often reported as one or more simple compact codes this element is often placed adjacent to the result value in reports and flow sheets to signal the meaning/normalcy status of the result.

                              Контроль0..*
                              ПривязкаЕсли они не подходят, эти коды ДОЛЖНЫ быть взяты из ObservationInterpretationVS (0.12.0)
                              (extensible to https://terminology.dhp.uz/fhir/core/ValueSet/observation-interpretation-vs|0.12.0)
                              ТипCodeableConcept
                              Модификаторfalse
                              Требуется поддержкаfalse
                              Summaryfalse
                              Требования

                              For some results, particularly numeric results, an interpretation is necessary to fully understand the significance of a result.

                              Альтернативные именаAbnormal Flag
                              Инвариантыele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
                              820. Observation.component:regionalNodeNote.referenceRange
                              Определение

                              Guidance on how to interpret the value by comparison to a normal or recommended range.

                              КороткийProvides guide for interpretation of component result
                              Комментарии

                              Most observations only have one generic reference range. Systems MAY choose to restrict to only supplying the relevant reference range based on knowledge about the patient (e.g., specific to the patient's age, gender, weight and other factors), but this might not be possible or appropriate. Whenever more than one reference range is supplied, the differences between them SHOULD be provided in the reference range and/or age properties.

                              Контроль0..*
                              ТипСмотретьttp://hl7.org/fhir/StructureDefinition/Observation#Observation.referenceRange
                              Модификаторfalse
                              Требуется поддержкаfalse
                              Summaryfalse
                              Требования

                              Knowing what values are considered "normal" can help evaluate the significance of a particular result. Need to be able to provide multiple reference ranges for different contexts.

                              Инвариантыele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
                              822. Observation.component:additionalChanges
                              Название разрезаadditionalChanges
                              Определение

                              Some observations have multiple component observations. These component observations are expressed as separate code value pairs that share the same attributes. Examples include systolic and diastolic component observations for blood pressure measurement and multiple component observations for genetics observations.

                              КороткийAdditional ultrasound changes
                              Комментарии

                              For a discussion on the ways Observations can be assembled in groups together see Notes below.

                              Контроль0..1
                              На этот элемент влияют следующие инварианты: obs-7
                              ТипBackboneElement
                              Модификаторfalse
                              Требуется поддержкаtrue
                              Summarytrue
                              Требования

                              Component observations share the same attributes in the Observation resource as the primary observation and are always treated a part of a single observation (they are not separable). However, the reference range for the primary observation value is not inherited by the component values and is required when appropriate for each component observation.

                              Инвариантыele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
                              824. Observation.component:additionalChanges.id
                              Определение

                              Unique id for the element within a resource (for internal references). This may be any string value that does not contain spaces.

                              КороткийUnique id for inter-element referencing
                              Контроль0..1
                              На этот элемент влияют следующие инварианты: ele-1
                              Типstring
                              Модификаторfalse
                              Формат XMLВ формате XML это свойство представлено в качестве атрибута.
                              Summaryfalse
                              826. Observation.component:additionalChanges.extension
                              Определение

                              May be used to represent additional information that is not part of the basic definition of the element. To make the use of extensions safe and managable, there is a strict set of governance applied to the definition and use of extensions. Though any implementer can define an extension, there is a set of requirements that SHALL be met as part of the definition of the extension.

                              КороткийAdditional content defined by implementations
                              Комментарии

                              There can be no stigma associated with the use of extensions by any application, project, or standard - regardless of the institution or jurisdiction that uses or defines the extensions. The use of extensions is what allows the FHIR specification to retain a core level of simplicity for everyone.

                              Контроль0..*
                              ТипExtension
                              Модификаторfalse
                              Summaryfalse
                              Альтернативные именаextensions, user content
                              Инвариантыele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
                              ext-1: Must have either extensions or value[x], not both (extension.exists() != value.exists())
                              828. Observation.component:additionalChanges.modifierExtension
                              Определение

                              May be used to represent additional information that is not part of the basic definition of the element and that modifies the understanding of the element in which it is contained and/or the understanding of the containing element's descendants. Usually modifier elements provide negation or qualification. To make the use of extensions safe and managable, there is a strict set of governance applied to the definition and use of extensions. Though any implementer can define an extension, there is a set of requirements that SHALL be met as part of the definition of the extension. Applications processing a resource are required to check for modifier extensions.

                              Modifier extensions SHALL NOT change the meaning of any elements on Resource or DomainResource (including cannot change the meaning of modifierExtension itself).

                              КороткийExtensions that cannot be ignored even if unrecognized
                              Комментарии

                              There can be no stigma associated with the use of extensions by any application, project, or standard - regardless of the institution or jurisdiction that uses or defines the extensions. The use of extensions is what allows the FHIR specification to retain a core level of simplicity for everyone.

                              Контроль0..*
                              ТипExtension
                              Модификаторtrue потому что Modifier extensions are expected to modify the meaning or interpretation of the element that contains them
                              Summarytrue
                              Требования

                              Modifier extensions allow for extensions that cannot be safely ignored to be clearly distinguished from the vast majority of extensions which can be safely ignored. This promotes interoperability by eliminating the need for implementers to prohibit the presence of extensions. For further information, see the definition of modifier extensions.

                              Альтернативные именаextensions, user content, modifiers
                              Инвариантыele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
                              ext-1: Must have either extensions or value[x], not both (extension.exists() != value.exists())
                              830. Observation.component:additionalChanges.code
                              Определение

                              Describes what was observed. Sometimes this is called the observation "code".

                              КороткийType of component observation (code / type)
                              Комментарии

                              All code-value and component.code-component.value pairs need to be taken into account to correctly understand the meaning of the observation.

                              Контроль1..1
                              На этот элемент влияют следующие инварианты: obs-7
                              ПривязкаКоды СЛЕДУЕТ взять из ObservationCodesVS (0.12.0)
                              (preferred to https://terminology.dhp.uz/fhir/core/ValueSet/observation-codes-vs|0.12.0)
                              ТипCodeableConcept
                              Модификаторfalse
                              Требуется поддержкаtrue
                              Summarytrue
                              Требования

                              Knowing what kind of observation is being made is essential to understanding the observation.

                              Значение шаблона{
                                "coding" : [{
                                  "system" : "https://terminology.dhp.uz/fhir/integrations/CodeSystem/screening-ultrasound-parameter-cs",
                                  "code" : "scrn-0052-00019"
                                }]
                              }
                              Инвариантыele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
                              832. Observation.component:additionalChanges.value[x]
                              Определение

                              The information determined as a result of making the observation, if the information has a simple value.

                              КороткийActual component result
                              Комментарии

                              Used when observation has a set of component observations:

                              • An observation may have both a value (e.g. an Apgar score) and component observations (the observations from which the Apgar score was derived).
                              • If a value is present, the datatype for this element should be determined by the code.
                              • CodeableConcept with just a text would be used instead of a string if the field was usually coded, or if the type associated with the code defines a coded value.
                              • Attachment is used if the observation result value is a binary file such as an image. If the observation result value is derived from the binary file (for example 'X' detected and here is the the proof in this image), the binary file may be directly represented using DocumentReference and referenced by derivedFrom.
                              • If a value is present, the datatype for this element should be determined by the code.
                              • CodeableConcept with just a text would be used instead of a string if the field was usually coded, or if the type associated with the code defines a coded value.
                              • Attachment is used if the observation result value is a binary file such as an image. If the observation result value is derived from the binary file (for example 'X' detected and here is the the proof in this image), the binary file may be directly represented using DocumentReference and referenced by derivedFrom.
                              • The usage of valueReference is restricted to the MolecularSequence resource when used as a definitional resource, not as a patient-specific finding. .
                              • For additional guidance, see the Notes section below.
                              Контроль1..1
                              Типstring
                              [x] ЗаметкаСмотретьВыбор типов данныхдля дополнительной информации о том, как использовать [x]
                              Модификаторfalse
                              Примитивное значениеЭтот примитивный элемент может присутствовать или отсутствовать, или быть замененным расширением
                              Требуется поддержкаtrue
                              Summarytrue
                              Требования

                              An observation exists to have a value, though it might not if it is in error, or if it represents a group of observations.

                              Инвариантыele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
                              834. Observation.component:additionalChanges.dataAbsentReason
                              Определение

                              Provides a reason why the expected value in the element Observation.component.value[x] is missing.

                              КороткийWhy the component result is missing
                              Комментарии

                              "Null" or exceptional values can be represented two ways in FHIR Observations. One way is to simply include them in the value set and represent the exceptions in the value. For example, measurement values for a serology test could be "detected", "not detected", "inconclusive", or "test not done".

                              The alternate way is to use the value element for actual observations and use the explicit dataAbsentReason element to record exceptional values. For example, the dataAbsentReason code "error" could be used when the measurement was not completed. Because of these options, use-case agreements are required to interpret general observations for exceptional values.

                              Контроль0..1
                              ПривязкаЕсли они не подходят, эти коды ДОЛЖНЫ быть взяты из DataAbsentReasonVS (0.12.0)
                              (extensible to https://terminology.dhp.uz/fhir/core/ValueSet/data-absent-reason-vs|0.12.0)
                              ТипCodeableConcept
                              Модификаторfalse
                              Требуется поддержкаfalse
                              Summaryfalse
                              Требования

                              For many results it is necessary to handle exceptional values in measurements.

                              Инвариантыele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
                              836. Observation.component:additionalChanges.interpretation
                              Определение

                              A categorical assessment of an observation value. For example, high, low, normal.

                              КороткийHigh, low, normal, etc
                              Комментарии

                              Historically used for laboratory results (known as 'abnormal flag' ), its use extends to other use cases where coded interpretations are relevant. Often reported as one or more simple compact codes this element is often placed adjacent to the result value in reports and flow sheets to signal the meaning/normalcy status of the result.

                              Контроль0..*
                              ПривязкаЕсли они не подходят, эти коды ДОЛЖНЫ быть взяты из ObservationInterpretationVS (0.12.0)
                              (extensible to https://terminology.dhp.uz/fhir/core/ValueSet/observation-interpretation-vs|0.12.0)
                              ТипCodeableConcept
                              Модификаторfalse
                              Требуется поддержкаfalse
                              Summaryfalse
                              Требования

                              For some results, particularly numeric results, an interpretation is necessary to fully understand the significance of a result.

                              Альтернативные именаAbnormal Flag
                              Инвариантыele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
                              838. Observation.component:additionalChanges.referenceRange
                              Определение

                              Guidance on how to interpret the value by comparison to a normal or recommended range.

                              КороткийProvides guide for interpretation of component result
                              Комментарии

                              Most observations only have one generic reference range. Systems MAY choose to restrict to only supplying the relevant reference range based on knowledge about the patient (e.g., specific to the patient's age, gender, weight and other factors), but this might not be possible or appropriate. Whenever more than one reference range is supplied, the differences between them SHOULD be provided in the reference range and/or age properties.

                              Контроль0..*
                              ТипСмотретьttp://hl7.org/fhir/StructureDefinition/Observation#Observation.referenceRange
                              Модификаторfalse
                              Требуется поддержкаfalse
                              Summaryfalse
                              Требования

                              Knowing what values are considered "normal" can help evaluate the significance of a particular result. Need to be able to provide multiple reference ranges for different contexts.

                              Инвариантыele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
                              840. Observation.component:focalLesionPresent
                              Название разрезаfocalLesionPresent
                              Определение

                              Some observations have multiple component observations. These component observations are expressed as separate code value pairs that share the same attributes. Examples include systolic and diastolic component observations for blood pressure measurement and multiple component observations for genetics observations.

                              КороткийFocal breast lesion present
                              Комментарии

                              For a discussion on the ways Observations can be assembled in groups together see Notes below.

                              Контроль0..1
                              На этот элемент влияют следующие инварианты: obs-7
                              ТипBackboneElement
                              Модификаторfalse
                              Требуется поддержкаtrue
                              Summarytrue
                              Требования

                              Component observations share the same attributes in the Observation resource as the primary observation and are always treated a part of a single observation (they are not separable). However, the reference range for the primary observation value is not inherited by the component values and is required when appropriate for each component observation.

                              Инвариантыele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
                              842. Observation.component:focalLesionPresent.id
                              Определение

                              Unique id for the element within a resource (for internal references). This may be any string value that does not contain spaces.

                              КороткийUnique id for inter-element referencing
                              Контроль0..1
                              На этот элемент влияют следующие инварианты: ele-1
                              Типstring
                              Модификаторfalse
                              Формат XMLВ формате XML это свойство представлено в качестве атрибута.
                              Summaryfalse
                              844. Observation.component:focalLesionPresent.extension
                              Определение

                              May be used to represent additional information that is not part of the basic definition of the element. To make the use of extensions safe and managable, there is a strict set of governance applied to the definition and use of extensions. Though any implementer can define an extension, there is a set of requirements that SHALL be met as part of the definition of the extension.

                              КороткийAdditional content defined by implementations
                              Комментарии

                              There can be no stigma associated with the use of extensions by any application, project, or standard - regardless of the institution or jurisdiction that uses or defines the extensions. The use of extensions is what allows the FHIR specification to retain a core level of simplicity for everyone.

                              Контроль0..*
                              ТипExtension
                              Модификаторfalse
                              Summaryfalse
                              Альтернативные именаextensions, user content
                              Инвариантыele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
                              ext-1: Must have either extensions or value[x], not both (extension.exists() != value.exists())
                              846. Observation.component:focalLesionPresent.modifierExtension
                              Определение

                              May be used to represent additional information that is not part of the basic definition of the element and that modifies the understanding of the element in which it is contained and/or the understanding of the containing element's descendants. Usually modifier elements provide negation or qualification. To make the use of extensions safe and managable, there is a strict set of governance applied to the definition and use of extensions. Though any implementer can define an extension, there is a set of requirements that SHALL be met as part of the definition of the extension. Applications processing a resource are required to check for modifier extensions.

                              Modifier extensions SHALL NOT change the meaning of any elements on Resource or DomainResource (including cannot change the meaning of modifierExtension itself).

                              КороткийExtensions that cannot be ignored even if unrecognized
                              Комментарии

                              There can be no stigma associated with the use of extensions by any application, project, or standard - regardless of the institution or jurisdiction that uses or defines the extensions. The use of extensions is what allows the FHIR specification to retain a core level of simplicity for everyone.

                              Контроль0..*
                              ТипExtension
                              Модификаторtrue потому что Modifier extensions are expected to modify the meaning or interpretation of the element that contains them
                              Summarytrue
                              Требования

                              Modifier extensions allow for extensions that cannot be safely ignored to be clearly distinguished from the vast majority of extensions which can be safely ignored. This promotes interoperability by eliminating the need for implementers to prohibit the presence of extensions. For further information, see the definition of modifier extensions.

                              Альтернативные именаextensions, user content, modifiers
                              Инвариантыele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
                              ext-1: Must have either extensions or value[x], not both (extension.exists() != value.exists())
                              848. Observation.component:focalLesionPresent.code
                              Определение

                              Describes what was observed. Sometimes this is called the observation "code".

                              КороткийType of component observation (code / type)
                              Комментарии

                              All code-value and component.code-component.value pairs need to be taken into account to correctly understand the meaning of the observation.

                              Контроль1..1
                              На этот элемент влияют следующие инварианты: obs-7
                              ПривязкаКоды СЛЕДУЕТ взять из ObservationCodesVS (0.12.0)
                              (preferred to https://terminology.dhp.uz/fhir/core/ValueSet/observation-codes-vs|0.12.0)
                              ТипCodeableConcept
                              Модификаторfalse
                              Требуется поддержкаtrue
                              Summarytrue
                              Требования

                              Knowing what kind of observation is being made is essential to understanding the observation.

                              Значение шаблона{
                                "coding" : [{
                                  "system" : "https://terminology.dhp.uz/fhir/integrations/CodeSystem/screening-ultrasound-parameter-cs",
                                  "code" : "scrn-0052-00021"
                                }]
                              }
                              Инвариантыele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
                              850. Observation.component:focalLesionPresent.value[x]
                              Определение

                              The information determined as a result of making the observation, if the information has a simple value.

                              КороткийActual component result
                              Комментарии

                              Used when observation has a set of component observations:

                              • An observation may have both a value (e.g. an Apgar score) and component observations (the observations from which the Apgar score was derived).
                              • If a value is present, the datatype for this element should be determined by the code.
                              • CodeableConcept with just a text would be used instead of a string if the field was usually coded, or if the type associated with the code defines a coded value.
                              • Attachment is used if the observation result value is a binary file such as an image. If the observation result value is derived from the binary file (for example 'X' detected and here is the the proof in this image), the binary file may be directly represented using DocumentReference and referenced by derivedFrom.
                              • If a value is present, the datatype for this element should be determined by the code.
                              • CodeableConcept with just a text would be used instead of a string if the field was usually coded, or if the type associated with the code defines a coded value.
                              • Attachment is used if the observation result value is a binary file such as an image. If the observation result value is derived from the binary file (for example 'X' detected and here is the the proof in this image), the binary file may be directly represented using DocumentReference and referenced by derivedFrom.
                              • The usage of valueReference is restricted to the MolecularSequence resource when used as a definitional resource, not as a patient-specific finding. .
                              • For additional guidance, see the Notes section below.
                              Контроль1..1
                              Типboolean
                              [x] ЗаметкаСмотретьВыбор типов данныхдля дополнительной информации о том, как использовать [x]
                              Модификаторfalse
                              Примитивное значениеЭтот примитивный элемент может присутствовать или отсутствовать, или быть замененным расширением
                              Требуется поддержкаtrue
                              Summarytrue
                              Требования

                              An observation exists to have a value, though it might not if it is in error, or if it represents a group of observations.

                              Инвариантыele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
                              852. Observation.component:focalLesionPresent.dataAbsentReason
                              Определение

                              Provides a reason why the expected value in the element Observation.component.value[x] is missing.

                              КороткийWhy the component result is missing
                              Комментарии

                              "Null" or exceptional values can be represented two ways in FHIR Observations. One way is to simply include them in the value set and represent the exceptions in the value. For example, measurement values for a serology test could be "detected", "not detected", "inconclusive", or "test not done".

                              The alternate way is to use the value element for actual observations and use the explicit dataAbsentReason element to record exceptional values. For example, the dataAbsentReason code "error" could be used when the measurement was not completed. Because of these options, use-case agreements are required to interpret general observations for exceptional values.

                              Контроль0..1
                              ПривязкаЕсли они не подходят, эти коды ДОЛЖНЫ быть взяты из DataAbsentReasonVS (0.12.0)
                              (extensible to https://terminology.dhp.uz/fhir/core/ValueSet/data-absent-reason-vs|0.12.0)
                              ТипCodeableConcept
                              Модификаторfalse
                              Требуется поддержкаfalse
                              Summaryfalse
                              Требования

                              For many results it is necessary to handle exceptional values in measurements.

                              Инвариантыele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
                              854. Observation.component:focalLesionPresent.interpretation
                              Определение

                              A categorical assessment of an observation value. For example, high, low, normal.

                              КороткийHigh, low, normal, etc
                              Комментарии

                              Historically used for laboratory results (known as 'abnormal flag' ), its use extends to other use cases where coded interpretations are relevant. Often reported as one or more simple compact codes this element is often placed adjacent to the result value in reports and flow sheets to signal the meaning/normalcy status of the result.

                              Контроль0..*
                              ПривязкаЕсли они не подходят, эти коды ДОЛЖНЫ быть взяты из ObservationInterpretationVS (0.12.0)
                              (extensible to https://terminology.dhp.uz/fhir/core/ValueSet/observation-interpretation-vs|0.12.0)
                              ТипCodeableConcept
                              Модификаторfalse
                              Требуется поддержкаfalse
                              Summaryfalse
                              Требования

                              For some results, particularly numeric results, an interpretation is necessary to fully understand the significance of a result.

                              Альтернативные именаAbnormal Flag
                              Инвариантыele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
                              856. Observation.component:focalLesionPresent.referenceRange
                              Определение

                              Guidance on how to interpret the value by comparison to a normal or recommended range.

                              КороткийProvides guide for interpretation of component result
                              Комментарии

                              Most observations only have one generic reference range. Systems MAY choose to restrict to only supplying the relevant reference range based on knowledge about the patient (e.g., specific to the patient's age, gender, weight and other factors), but this might not be possible or appropriate. Whenever more than one reference range is supplied, the differences between them SHOULD be provided in the reference range and/or age properties.

                              Контроль0..*
                              ТипСмотретьttp://hl7.org/fhir/StructureDefinition/Observation#Observation.referenceRange
                              Модификаторfalse
                              Требуется поддержкаfalse
                              Summaryfalse
                              Требования

                              Knowing what values are considered "normal" can help evaluate the significance of a particular result. Need to be able to provide multiple reference ranges for different contexts.

                              Инвариантыele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
                              858. Observation.component:clockFacePosition
                              Название разрезаclockFacePosition
                              Определение

                              Some observations have multiple component observations. These component observations are expressed as separate code value pairs that share the same attributes. Examples include systolic and diastolic component observations for blood pressure measurement and multiple component observations for genetics observations.

                              КороткийLesion clock-face position, 1 to 12
                              Комментарии

                              For a discussion on the ways Observations can be assembled in groups together see Notes below.

                              Контроль0..1
                              На этот элемент влияют следующие инварианты: obs-7
                              ТипBackboneElement
                              Модификаторfalse
                              Требуется поддержкаtrue
                              Summarytrue
                              Требования

                              Component observations share the same attributes in the Observation resource as the primary observation and are always treated a part of a single observation (they are not separable). However, the reference range for the primary observation value is not inherited by the component values and is required when appropriate for each component observation.

                              Инвариантыele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
                              860. Observation.component:clockFacePosition.id
                              Определение

                              Unique id for the element within a resource (for internal references). This may be any string value that does not contain spaces.

                              КороткийUnique id for inter-element referencing
                              Контроль0..1
                              На этот элемент влияют следующие инварианты: ele-1
                              Типstring
                              Модификаторfalse
                              Формат XMLВ формате XML это свойство представлено в качестве атрибута.
                              Summaryfalse
                              862. Observation.component:clockFacePosition.extension
                              Определение

                              May be used to represent additional information that is not part of the basic definition of the element. To make the use of extensions safe and managable, there is a strict set of governance applied to the definition and use of extensions. Though any implementer can define an extension, there is a set of requirements that SHALL be met as part of the definition of the extension.

                              КороткийAdditional content defined by implementations
                              Комментарии

                              There can be no stigma associated with the use of extensions by any application, project, or standard - regardless of the institution or jurisdiction that uses or defines the extensions. The use of extensions is what allows the FHIR specification to retain a core level of simplicity for everyone.

                              Контроль0..*
                              ТипExtension
                              Модификаторfalse
                              Summaryfalse
                              Альтернативные именаextensions, user content
                              Инвариантыele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
                              ext-1: Must have either extensions or value[x], not both (extension.exists() != value.exists())
                              864. Observation.component:clockFacePosition.modifierExtension
                              Определение

                              May be used to represent additional information that is not part of the basic definition of the element and that modifies the understanding of the element in which it is contained and/or the understanding of the containing element's descendants. Usually modifier elements provide negation or qualification. To make the use of extensions safe and managable, there is a strict set of governance applied to the definition and use of extensions. Though any implementer can define an extension, there is a set of requirements that SHALL be met as part of the definition of the extension. Applications processing a resource are required to check for modifier extensions.

                              Modifier extensions SHALL NOT change the meaning of any elements on Resource or DomainResource (including cannot change the meaning of modifierExtension itself).

                              КороткийExtensions that cannot be ignored even if unrecognized
                              Комментарии

                              There can be no stigma associated with the use of extensions by any application, project, or standard - regardless of the institution or jurisdiction that uses or defines the extensions. The use of extensions is what allows the FHIR specification to retain a core level of simplicity for everyone.

                              Контроль0..*
                              ТипExtension
                              Модификаторtrue потому что Modifier extensions are expected to modify the meaning or interpretation of the element that contains them
                              Summarytrue
                              Требования

                              Modifier extensions allow for extensions that cannot be safely ignored to be clearly distinguished from the vast majority of extensions which can be safely ignored. This promotes interoperability by eliminating the need for implementers to prohibit the presence of extensions. For further information, see the definition of modifier extensions.

                              Альтернативные именаextensions, user content, modifiers
                              Инвариантыele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
                              ext-1: Must have either extensions or value[x], not both (extension.exists() != value.exists())
                              866. Observation.component:clockFacePosition.code
                              Определение

                              Describes what was observed. Sometimes this is called the observation "code".

                              КороткийType of component observation (code / type)
                              Комментарии

                              All code-value and component.code-component.value pairs need to be taken into account to correctly understand the meaning of the observation.

                              Контроль1..1
                              На этот элемент влияют следующие инварианты: obs-7
                              ПривязкаКоды СЛЕДУЕТ взять из ObservationCodesVS (0.12.0)
                              (preferred to https://terminology.dhp.uz/fhir/core/ValueSet/observation-codes-vs|0.12.0)
                              ТипCodeableConcept
                              Модификаторfalse
                              Требуется поддержкаtrue
                              Summarytrue
                              Требования

                              Knowing what kind of observation is being made is essential to understanding the observation.

                              Значение шаблона{
                                "coding" : [{
                                  "system" : "https://terminology.dhp.uz/fhir/integrations/CodeSystem/screening-ultrasound-parameter-cs",
                                  "code" : "scrn-0052-00022"
                                }]
                              }
                              Инвариантыele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
                              868. Observation.component:clockFacePosition.value[x]
                              Определение

                              The information determined as a result of making the observation, if the information has a simple value.

                              КороткийActual component result
                              Комментарии

                              Used when observation has a set of component observations:

                              • An observation may have both a value (e.g. an Apgar score) and component observations (the observations from which the Apgar score was derived).
                              • If a value is present, the datatype for this element should be determined by the code.
                              • CodeableConcept with just a text would be used instead of a string if the field was usually coded, or if the type associated with the code defines a coded value.
                              • Attachment is used if the observation result value is a binary file such as an image. If the observation result value is derived from the binary file (for example 'X' detected and here is the the proof in this image), the binary file may be directly represented using DocumentReference and referenced by derivedFrom.
                              • If a value is present, the datatype for this element should be determined by the code.
                              • CodeableConcept with just a text would be used instead of a string if the field was usually coded, or if the type associated with the code defines a coded value.
                              • Attachment is used if the observation result value is a binary file such as an image. If the observation result value is derived from the binary file (for example 'X' detected and here is the the proof in this image), the binary file may be directly represented using DocumentReference and referenced by derivedFrom.
                              • The usage of valueReference is restricted to the MolecularSequence resource when used as a definitional resource, not as a patient-specific finding. .
                              • For additional guidance, see the Notes section below.
                              Контроль1..1
                              Типinteger
                              [x] ЗаметкаСмотретьВыбор типов данныхдля дополнительной информации о том, как использовать [x]
                              Модификаторfalse
                              Примитивное значениеЭтот примитивный элемент может присутствовать или отсутствовать, или быть замененным расширением
                              Требуется поддержкаtrue
                              Summarytrue
                              Требования

                              An observation exists to have a value, though it might not if it is in error, or if it represents a group of observations.

                              Мин. значение1
                              Максимальное значение12
                              Инвариантыele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
                              870. Observation.component:clockFacePosition.dataAbsentReason
                              Определение

                              Provides a reason why the expected value in the element Observation.component.value[x] is missing.

                              КороткийWhy the component result is missing
                              Комментарии

                              "Null" or exceptional values can be represented two ways in FHIR Observations. One way is to simply include them in the value set and represent the exceptions in the value. For example, measurement values for a serology test could be "detected", "not detected", "inconclusive", or "test not done".

                              The alternate way is to use the value element for actual observations and use the explicit dataAbsentReason element to record exceptional values. For example, the dataAbsentReason code "error" could be used when the measurement was not completed. Because of these options, use-case agreements are required to interpret general observations for exceptional values.

                              Контроль0..1
                              ПривязкаЕсли они не подходят, эти коды ДОЛЖНЫ быть взяты из DataAbsentReasonVS (0.12.0)
                              (extensible to https://terminology.dhp.uz/fhir/core/ValueSet/data-absent-reason-vs|0.12.0)
                              ТипCodeableConcept
                              Модификаторfalse
                              Требуется поддержкаfalse
                              Summaryfalse
                              Требования

                              For many results it is necessary to handle exceptional values in measurements.

                              Инвариантыele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
                              872. Observation.component:clockFacePosition.interpretation
                              Определение

                              A categorical assessment of an observation value. For example, high, low, normal.

                              КороткийHigh, low, normal, etc
                              Комментарии

                              Historically used for laboratory results (known as 'abnormal flag' ), its use extends to other use cases where coded interpretations are relevant. Often reported as one or more simple compact codes this element is often placed adjacent to the result value in reports and flow sheets to signal the meaning/normalcy status of the result.

                              Контроль0..*
                              ПривязкаЕсли они не подходят, эти коды ДОЛЖНЫ быть взяты из ObservationInterpretationVS (0.12.0)
                              (extensible to https://terminology.dhp.uz/fhir/core/ValueSet/observation-interpretation-vs|0.12.0)
                              ТипCodeableConcept
                              Модификаторfalse
                              Требуется поддержкаfalse
                              Summaryfalse
                              Требования

                              For some results, particularly numeric results, an interpretation is necessary to fully understand the significance of a result.

                              Альтернативные именаAbnormal Flag
                              Инвариантыele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
                              874. Observation.component:clockFacePosition.referenceRange
                              Определение

                              Guidance on how to interpret the value by comparison to a normal or recommended range.

                              КороткийProvides guide for interpretation of component result
                              Комментарии

                              Most observations only have one generic reference range. Systems MAY choose to restrict to only supplying the relevant reference range based on knowledge about the patient (e.g., specific to the patient's age, gender, weight and other factors), but this might not be possible or appropriate. Whenever more than one reference range is supplied, the differences between them SHOULD be provided in the reference range and/or age properties.

                              Контроль0..*
                              ТипСмотретьttp://hl7.org/fhir/StructureDefinition/Observation#Observation.referenceRange
                              Модификаторfalse
                              Требуется поддержкаfalse
                              Summaryfalse
                              Требования

                              Knowing what values are considered "normal" can help evaluate the significance of a particular result. Need to be able to provide multiple reference ranges for different contexts.

                              Инвариантыele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
                              876. Observation.component:distanceFromNipple
                              Название разрезаdistanceFromNipple
                              Определение

                              Some observations have multiple component observations. These component observations are expressed as separate code value pairs that share the same attributes. Examples include systolic and diastolic component observations for blood pressure measurement and multiple component observations for genetics observations.

                              КороткийDistance from nipple
                              Комментарии

                              For a discussion on the ways Observations can be assembled in groups together see Notes below.

                              Контроль0..1
                              На этот элемент влияют следующие инварианты: obs-7
                              ТипBackboneElement
                              Модификаторfalse
                              Требуется поддержкаtrue
                              Summarytrue
                              Требования

                              Component observations share the same attributes in the Observation resource as the primary observation and are always treated a part of a single observation (they are not separable). However, the reference range for the primary observation value is not inherited by the component values and is required when appropriate for each component observation.

                              Инвариантыele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
                              878. Observation.component:distanceFromNipple.id
                              Определение

                              Unique id for the element within a resource (for internal references). This may be any string value that does not contain spaces.

                              КороткийUnique id for inter-element referencing
                              Контроль0..1
                              На этот элемент влияют следующие инварианты: ele-1
                              Типstring
                              Модификаторfalse
                              Формат XMLВ формате XML это свойство представлено в качестве атрибута.
                              Summaryfalse
                              880. Observation.component:distanceFromNipple.extension
                              Определение

                              May be used to represent additional information that is not part of the basic definition of the element. To make the use of extensions safe and managable, there is a strict set of governance applied to the definition and use of extensions. Though any implementer can define an extension, there is a set of requirements that SHALL be met as part of the definition of the extension.

                              КороткийAdditional content defined by implementations
                              Комментарии

                              There can be no stigma associated with the use of extensions by any application, project, or standard - regardless of the institution or jurisdiction that uses or defines the extensions. The use of extensions is what allows the FHIR specification to retain a core level of simplicity for everyone.

                              Контроль0..*
                              ТипExtension
                              Модификаторfalse
                              Summaryfalse
                              Альтернативные именаextensions, user content
                              Инвариантыele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
                              ext-1: Must have either extensions or value[x], not both (extension.exists() != value.exists())
                              882. Observation.component:distanceFromNipple.modifierExtension
                              Определение

                              May be used to represent additional information that is not part of the basic definition of the element and that modifies the understanding of the element in which it is contained and/or the understanding of the containing element's descendants. Usually modifier elements provide negation or qualification. To make the use of extensions safe and managable, there is a strict set of governance applied to the definition and use of extensions. Though any implementer can define an extension, there is a set of requirements that SHALL be met as part of the definition of the extension. Applications processing a resource are required to check for modifier extensions.

                              Modifier extensions SHALL NOT change the meaning of any elements on Resource or DomainResource (including cannot change the meaning of modifierExtension itself).

                              КороткийExtensions that cannot be ignored even if unrecognized
                              Комментарии

                              There can be no stigma associated with the use of extensions by any application, project, or standard - regardless of the institution or jurisdiction that uses or defines the extensions. The use of extensions is what allows the FHIR specification to retain a core level of simplicity for everyone.

                              Контроль0..*
                              ТипExtension
                              Модификаторtrue потому что Modifier extensions are expected to modify the meaning or interpretation of the element that contains them
                              Summarytrue
                              Требования

                              Modifier extensions allow for extensions that cannot be safely ignored to be clearly distinguished from the vast majority of extensions which can be safely ignored. This promotes interoperability by eliminating the need for implementers to prohibit the presence of extensions. For further information, see the definition of modifier extensions.

                              Альтернативные именаextensions, user content, modifiers
                              Инвариантыele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
                              ext-1: Must have either extensions or value[x], not both (extension.exists() != value.exists())
                              884. Observation.component:distanceFromNipple.code
                              Определение

                              Describes what was observed. Sometimes this is called the observation "code".

                              КороткийType of component observation (code / type)
                              Комментарии

                              All code-value and component.code-component.value pairs need to be taken into account to correctly understand the meaning of the observation.

                              Контроль1..1
                              На этот элемент влияют следующие инварианты: obs-7
                              ПривязкаКоды СЛЕДУЕТ взять из ObservationCodesVS (0.12.0)
                              (preferred to https://terminology.dhp.uz/fhir/core/ValueSet/observation-codes-vs|0.12.0)
                              ТипCodeableConcept
                              Модификаторfalse
                              Требуется поддержкаtrue
                              Summarytrue
                              Требования

                              Knowing what kind of observation is being made is essential to understanding the observation.

                              Значение шаблона{
                                "coding" : [{
                                  "system" : "https://terminology.dhp.uz/fhir/integrations/CodeSystem/screening-ultrasound-parameter-cs",
                                  "code" : "scrn-0052-00023"
                                }]
                              }
                              Инвариантыele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
                              886. Observation.component:distanceFromNipple.value[x]
                              Определение

                              The information determined as a result of making the observation, if the information has a simple value.

                              КороткийActual component result
                              Комментарии

                              Used when observation has a set of component observations:

                              • An observation may have both a value (e.g. an Apgar score) and component observations (the observations from which the Apgar score was derived).
                              • If a value is present, the datatype for this element should be determined by the code.
                              • CodeableConcept with just a text would be used instead of a string if the field was usually coded, or if the type associated with the code defines a coded value.
                              • Attachment is used if the observation result value is a binary file such as an image. If the observation result value is derived from the binary file (for example 'X' detected and here is the the proof in this image), the binary file may be directly represented using DocumentReference and referenced by derivedFrom.
                              • If a value is present, the datatype for this element should be determined by the code.
                              • CodeableConcept with just a text would be used instead of a string if the field was usually coded, or if the type associated with the code defines a coded value.
                              • Attachment is used if the observation result value is a binary file such as an image. If the observation result value is derived from the binary file (for example 'X' detected and here is the the proof in this image), the binary file may be directly represented using DocumentReference and referenced by derivedFrom.
                              • The usage of valueReference is restricted to the MolecularSequence resource when used as a definitional resource, not as a patient-specific finding. .
                              • For additional guidance, see the Notes section below.
                              Контроль1..1
                              ТипQuantity
                              [x] ЗаметкаСмотретьВыбор типов данныхдля дополнительной информации о том, как использовать [x]
                              Модификаторfalse
                              Требуется поддержкаtrue
                              Summarytrue
                              Требования

                              An observation exists to have a value, though it might not if it is in error, or if it represents a group of observations.

                              Значение шаблона{
                                "unit" : "mm",
                                "system" : "http://unitsofmeasure.org",
                                "code" : "mm"
                              }
                              Инвариантыele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
                              888. Observation.component:distanceFromNipple.value[x].id
                              Определение

                              Unique id for the element within a resource (for internal references). This may be any string value that does not contain spaces.

                              КороткийUnique id for inter-element referencing
                              Контроль0..1
                              На этот элемент влияют следующие инварианты: ele-1
                              Типid
                              Модификаторfalse
                              Формат XMLВ формате XML это свойство представлено в качестве атрибута.
                              Summaryfalse
                              890. Observation.component:distanceFromNipple.value[x].extension
                              Определение

                              May be used to represent additional information that is not part of the basic definition of the element. To make the use of extensions safe and managable, there is a strict set of governance applied to the definition and use of extensions. Though any implementer can define an extension, there is a set of requirements that SHALL be met as part of the definition of the extension.

                              КороткийAdditional content defined by implementations
                              Комментарии

                              There can be no stigma associated with the use of extensions by any application, project, or standard - regardless of the institution or jurisdiction that uses or defines the extensions. The use of extensions is what allows the FHIR specification to retain a core level of simplicity for everyone.

                              Контроль0..*
                              ТипExtension
                              Модификаторfalse
                              Summaryfalse
                              Альтернативные именаextensions, user content
                              Инвариантыele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
                              ext-1: Must have either extensions or value[x], not both (extension.exists() != value.exists())
                              SlicingЭтот элемент представляет набор разрезов на Observation.component.value[x].extension. Разрезы бываютНе упорядочено и Open, и могут быть дифференцированы с помощью следующих дискриминаторов:
                              • value @ url
                              • 892. Observation.component:distanceFromNipple.value[x].value
                                Определение

                                The value of the measured amount. The value includes an implicit precision in the presentation of the value.

                                КороткийNumerical value (with implicit precision)
                                Комментарии

                                The implicit precision in the value should always be honored. Monetary values have their own rules for handling precision (refer to standard accounting text books).

                                Контроль1..1
                                Типdecimal
                                Модификаторfalse
                                Примитивное значениеЭтот примитивный элемент может присутствовать или отсутствовать, или быть замененным расширением
                                Summarytrue
                                Требования

                                Precision is handled implicitly in almost all cases of measurement.

                                Мин. значение0
                                Инвариантыele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
                                894. Observation.component:distanceFromNipple.value[x].comparator
                                Определение

                                How the value should be understood and represented - whether the actual value is greater or less than the stated value due to measurement issues; e.g. if the comparator is "<" , then the real value is < stated value.

                                Короткий< | <= | >= | > | ad - how to understand the value
                                Контроль0..1
                                ПривязкаКоды ДОЛЖНЫ быть взяты из QuantityComparator
                                (required to http://hl7.org/fhir/ValueSet/quantity-comparator|5.0.0)

                                How the Quantity should be understood and represented.

                                Типcode
                                Модификаторtrue потому что This is labeled as "Is Modifier" because the comparator modifies the interpretation of the value significantly. If there is no comparator, then there is no modification of the value
                                Примитивное значениеЭтот примитивный элемент может присутствовать или отсутствовать, или быть замененным расширением
                                Summarytrue
                                Требования

                                Need a framework for handling measures where the value is <5ug/L or >400mg/L due to the limitations of measuring methodology.

                                Значение при отсутствииIf there is no comparator, then there is no modification of the value
                                Инвариантыele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
                                896. Observation.component:distanceFromNipple.value[x].unit
                                Определение

                                A human-readable form of the unit.

                                КороткийUnit representation
                                Контроль1..1
                                Типstring
                                Модификаторfalse
                                Примитивное значениеЭтот примитивный элемент может присутствовать или отсутствовать, или быть замененным расширением
                                Summarytrue
                                Требования

                                There are many representations for units of measure and in many contexts, particular representations are fixed and required. I.e. mcg for micrograms.

                                Инвариантыele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
                                898. Observation.component:distanceFromNipple.value[x].system
                                Определение

                                The identification of the system that provides the coded form of the unit.

                                КороткийSystem that defines coded unit form
                                Контроль1..1
                                На этот элемент влияют следующие инварианты: qty-3
                                Типuri
                                Модификаторfalse
                                Примитивное значениеЭтот примитивный элемент может присутствовать или отсутствовать, или быть замененным расширением
                                Summarytrue
                                Требования

                                Need to know the system that defines the coded form of the unit.

                                Инвариантыele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
                                900. Observation.component:distanceFromNipple.value[x].code
                                Определение

                                A computer processable form of the unit in some unit representation system.

                                КороткийCoded form of the unit
                                Комментарии

                                The preferred system is UCUM, but SNOMED CT can also be used (for customary units) or ISO 4217 for currency. The context of use may additionally require a code from a particular system.

                                Контроль1..1
                                На этот элемент влияют следующие инварианты: qty-3
                                Типcode
                                Модификаторfalse
                                Примитивное значениеЭтот примитивный элемент может присутствовать или отсутствовать, или быть замененным расширением
                                Summarytrue
                                Требования

                                Need a computable form of the unit that is fixed across all forms. UCUM provides this for quantities, but SNOMED CT provides many units of interest.

                                Инвариантыele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
                                902. Observation.component:distanceFromNipple.dataAbsentReason
                                Определение

                                Provides a reason why the expected value in the element Observation.component.value[x] is missing.

                                КороткийWhy the component result is missing
                                Комментарии

                                "Null" or exceptional values can be represented two ways in FHIR Observations. One way is to simply include them in the value set and represent the exceptions in the value. For example, measurement values for a serology test could be "detected", "not detected", "inconclusive", or "test not done".

                                The alternate way is to use the value element for actual observations and use the explicit dataAbsentReason element to record exceptional values. For example, the dataAbsentReason code "error" could be used when the measurement was not completed. Because of these options, use-case agreements are required to interpret general observations for exceptional values.

                                Контроль0..1
                                ПривязкаЕсли они не подходят, эти коды ДОЛЖНЫ быть взяты из DataAbsentReasonVS (0.12.0)
                                (extensible to https://terminology.dhp.uz/fhir/core/ValueSet/data-absent-reason-vs|0.12.0)
                                ТипCodeableConcept
                                Модификаторfalse
                                Требуется поддержкаfalse
                                Summaryfalse
                                Требования

                                For many results it is necessary to handle exceptional values in measurements.

                                Инвариантыele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
                                904. Observation.component:distanceFromNipple.interpretation
                                Определение

                                A categorical assessment of an observation value. For example, high, low, normal.

                                КороткийHigh, low, normal, etc
                                Комментарии

                                Historically used for laboratory results (known as 'abnormal flag' ), its use extends to other use cases where coded interpretations are relevant. Often reported as one or more simple compact codes this element is often placed adjacent to the result value in reports and flow sheets to signal the meaning/normalcy status of the result.

                                Контроль0..*
                                ПривязкаЕсли они не подходят, эти коды ДОЛЖНЫ быть взяты из ObservationInterpretationVS (0.12.0)
                                (extensible to https://terminology.dhp.uz/fhir/core/ValueSet/observation-interpretation-vs|0.12.0)
                                ТипCodeableConcept
                                Модификаторfalse
                                Требуется поддержкаfalse
                                Summaryfalse
                                Требования

                                For some results, particularly numeric results, an interpretation is necessary to fully understand the significance of a result.

                                Альтернативные именаAbnormal Flag
                                Инвариантыele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
                                906. Observation.component:distanceFromNipple.referenceRange
                                Определение

                                Guidance on how to interpret the value by comparison to a normal or recommended range.

                                КороткийProvides guide for interpretation of component result
                                Комментарии

                                Most observations only have one generic reference range. Systems MAY choose to restrict to only supplying the relevant reference range based on knowledge about the patient (e.g., specific to the patient's age, gender, weight and other factors), but this might not be possible or appropriate. Whenever more than one reference range is supplied, the differences between them SHOULD be provided in the reference range and/or age properties.

                                Контроль0..*
                                ТипСмотретьttp://hl7.org/fhir/StructureDefinition/Observation#Observation.referenceRange
                                Модификаторfalse
                                Требуется поддержкаfalse
                                Summaryfalse
                                Требования

                                Knowing what values are considered "normal" can help evaluate the significance of a particular result. Need to be able to provide multiple reference ranges for different contexts.

                                Инвариантыele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
                                908. Observation.component:lesionLength
                                Название разрезаlesionLength
                                Определение

                                Some observations have multiple component observations. These component observations are expressed as separate code value pairs that share the same attributes. Examples include systolic and diastolic component observations for blood pressure measurement and multiple component observations for genetics observations.

                                КороткийLesion length
                                Комментарии

                                For a discussion on the ways Observations can be assembled in groups together see Notes below.

                                Контроль0..1
                                На этот элемент влияют следующие инварианты: obs-7
                                ТипBackboneElement
                                Модификаторfalse
                                Требуется поддержкаtrue
                                Summarytrue
                                Требования

                                Component observations share the same attributes in the Observation resource as the primary observation and are always treated a part of a single observation (they are not separable). However, the reference range for the primary observation value is not inherited by the component values and is required when appropriate for each component observation.

                                Инвариантыele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
                                910. Observation.component:lesionLength.id
                                Определение

                                Unique id for the element within a resource (for internal references). This may be any string value that does not contain spaces.

                                КороткийUnique id for inter-element referencing
                                Контроль0..1
                                На этот элемент влияют следующие инварианты: ele-1
                                Типstring
                                Модификаторfalse
                                Формат XMLВ формате XML это свойство представлено в качестве атрибута.
                                Summaryfalse
                                912. Observation.component:lesionLength.extension
                                Определение

                                May be used to represent additional information that is not part of the basic definition of the element. To make the use of extensions safe and managable, there is a strict set of governance applied to the definition and use of extensions. Though any implementer can define an extension, there is a set of requirements that SHALL be met as part of the definition of the extension.

                                КороткийAdditional content defined by implementations
                                Комментарии

                                There can be no stigma associated with the use of extensions by any application, project, or standard - regardless of the institution or jurisdiction that uses or defines the extensions. The use of extensions is what allows the FHIR specification to retain a core level of simplicity for everyone.

                                Контроль0..*
                                ТипExtension
                                Модификаторfalse
                                Summaryfalse
                                Альтернативные именаextensions, user content
                                Инвариантыele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
                                ext-1: Must have either extensions or value[x], not both (extension.exists() != value.exists())
                                914. Observation.component:lesionLength.modifierExtension
                                Определение

                                May be used to represent additional information that is not part of the basic definition of the element and that modifies the understanding of the element in which it is contained and/or the understanding of the containing element's descendants. Usually modifier elements provide negation or qualification. To make the use of extensions safe and managable, there is a strict set of governance applied to the definition and use of extensions. Though any implementer can define an extension, there is a set of requirements that SHALL be met as part of the definition of the extension. Applications processing a resource are required to check for modifier extensions.

                                Modifier extensions SHALL NOT change the meaning of any elements on Resource or DomainResource (including cannot change the meaning of modifierExtension itself).

                                КороткийExtensions that cannot be ignored even if unrecognized
                                Комментарии

                                There can be no stigma associated with the use of extensions by any application, project, or standard - regardless of the institution or jurisdiction that uses or defines the extensions. The use of extensions is what allows the FHIR specification to retain a core level of simplicity for everyone.

                                Контроль0..*
                                ТипExtension
                                Модификаторtrue потому что Modifier extensions are expected to modify the meaning or interpretation of the element that contains them
                                Summarytrue
                                Требования

                                Modifier extensions allow for extensions that cannot be safely ignored to be clearly distinguished from the vast majority of extensions which can be safely ignored. This promotes interoperability by eliminating the need for implementers to prohibit the presence of extensions. For further information, see the definition of modifier extensions.

                                Альтернативные именаextensions, user content, modifiers
                                Инвариантыele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
                                ext-1: Must have either extensions or value[x], not both (extension.exists() != value.exists())
                                916. Observation.component:lesionLength.code
                                Определение

                                Describes what was observed. Sometimes this is called the observation "code".

                                КороткийType of component observation (code / type)
                                Комментарии

                                All code-value and component.code-component.value pairs need to be taken into account to correctly understand the meaning of the observation.

                                Контроль1..1
                                На этот элемент влияют следующие инварианты: obs-7
                                ПривязкаКоды СЛЕДУЕТ взять из ObservationCodesVS (0.12.0)
                                (preferred to https://terminology.dhp.uz/fhir/core/ValueSet/observation-codes-vs|0.12.0)
                                ТипCodeableConcept
                                Модификаторfalse
                                Требуется поддержкаtrue
                                Summarytrue
                                Требования

                                Knowing what kind of observation is being made is essential to understanding the observation.

                                Значение шаблона{
                                  "coding" : [{
                                    "system" : "https://terminology.dhp.uz/fhir/integrations/CodeSystem/screening-ultrasound-parameter-cs",
                                    "code" : "scrn-0052-00024"
                                  }]
                                }
                                Инвариантыele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
                                918. Observation.component:lesionLength.value[x]
                                Определение

                                The information determined as a result of making the observation, if the information has a simple value.

                                КороткийActual component result
                                Комментарии

                                Used when observation has a set of component observations:

                                • An observation may have both a value (e.g. an Apgar score) and component observations (the observations from which the Apgar score was derived).
                                • If a value is present, the datatype for this element should be determined by the code.
                                • CodeableConcept with just a text would be used instead of a string if the field was usually coded, or if the type associated with the code defines a coded value.
                                • Attachment is used if the observation result value is a binary file such as an image. If the observation result value is derived from the binary file (for example 'X' detected and here is the the proof in this image), the binary file may be directly represented using DocumentReference and referenced by derivedFrom.
                                • If a value is present, the datatype for this element should be determined by the code.
                                • CodeableConcept with just a text would be used instead of a string if the field was usually coded, or if the type associated with the code defines a coded value.
                                • Attachment is used if the observation result value is a binary file such as an image. If the observation result value is derived from the binary file (for example 'X' detected and here is the the proof in this image), the binary file may be directly represented using DocumentReference and referenced by derivedFrom.
                                • The usage of valueReference is restricted to the MolecularSequence resource when used as a definitional resource, not as a patient-specific finding. .
                                • For additional guidance, see the Notes section below.
                                Контроль1..1
                                ТипQuantity
                                [x] ЗаметкаСмотретьВыбор типов данныхдля дополнительной информации о том, как использовать [x]
                                Модификаторfalse
                                Требуется поддержкаtrue
                                Summarytrue
                                Требования

                                An observation exists to have a value, though it might not if it is in error, or if it represents a group of observations.

                                Значение шаблона{
                                  "unit" : "mm",
                                  "system" : "http://unitsofmeasure.org",
                                  "code" : "mm"
                                }
                                Инвариантыele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
                                920. Observation.component:lesionLength.value[x].id
                                Определение

                                Unique id for the element within a resource (for internal references). This may be any string value that does not contain spaces.

                                КороткийUnique id for inter-element referencing
                                Контроль0..1
                                На этот элемент влияют следующие инварианты: ele-1
                                Типid
                                Модификаторfalse
                                Формат XMLВ формате XML это свойство представлено в качестве атрибута.
                                Summaryfalse
                                922. Observation.component:lesionLength.value[x].extension
                                Определение

                                May be used to represent additional information that is not part of the basic definition of the element. To make the use of extensions safe and managable, there is a strict set of governance applied to the definition and use of extensions. Though any implementer can define an extension, there is a set of requirements that SHALL be met as part of the definition of the extension.

                                КороткийAdditional content defined by implementations
                                Комментарии

                                There can be no stigma associated with the use of extensions by any application, project, or standard - regardless of the institution or jurisdiction that uses or defines the extensions. The use of extensions is what allows the FHIR specification to retain a core level of simplicity for everyone.

                                Контроль0..*
                                ТипExtension
                                Модификаторfalse
                                Summaryfalse
                                Альтернативные именаextensions, user content
                                Инвариантыele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
                                ext-1: Must have either extensions or value[x], not both (extension.exists() != value.exists())
                                SlicingЭтот элемент представляет набор разрезов на Observation.component.value[x].extension. Разрезы бываютНе упорядочено и Open, и могут быть дифференцированы с помощью следующих дискриминаторов:
                                • value @ url
                                • 924. Observation.component:lesionLength.value[x].value
                                  Определение

                                  The value of the measured amount. The value includes an implicit precision in the presentation of the value.

                                  КороткийNumerical value (with implicit precision)
                                  Комментарии

                                  The implicit precision in the value should always be honored. Monetary values have their own rules for handling precision (refer to standard accounting text books).

                                  Контроль1..1
                                  Типdecimal
                                  Модификаторfalse
                                  Примитивное значениеЭтот примитивный элемент может присутствовать или отсутствовать, или быть замененным расширением
                                  Summarytrue
                                  Требования

                                  Precision is handled implicitly in almost all cases of measurement.

                                  Мин. значение0
                                  Инвариантыele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
                                  926. Observation.component:lesionLength.value[x].comparator
                                  Определение

                                  How the value should be understood and represented - whether the actual value is greater or less than the stated value due to measurement issues; e.g. if the comparator is "<" , then the real value is < stated value.

                                  Короткий< | <= | >= | > | ad - how to understand the value
                                  Контроль0..1
                                  ПривязкаКоды ДОЛЖНЫ быть взяты из QuantityComparator
                                  (required to http://hl7.org/fhir/ValueSet/quantity-comparator|5.0.0)

                                  How the Quantity should be understood and represented.

                                  Типcode
                                  Модификаторtrue потому что This is labeled as "Is Modifier" because the comparator modifies the interpretation of the value significantly. If there is no comparator, then there is no modification of the value
                                  Примитивное значениеЭтот примитивный элемент может присутствовать или отсутствовать, или быть замененным расширением
                                  Summarytrue
                                  Требования

                                  Need a framework for handling measures where the value is <5ug/L or >400mg/L due to the limitations of measuring methodology.

                                  Значение при отсутствииIf there is no comparator, then there is no modification of the value
                                  Инвариантыele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
                                  928. Observation.component:lesionLength.value[x].unit
                                  Определение

                                  A human-readable form of the unit.

                                  КороткийUnit representation
                                  Контроль1..1
                                  Типstring
                                  Модификаторfalse
                                  Примитивное значениеЭтот примитивный элемент может присутствовать или отсутствовать, или быть замененным расширением
                                  Summarytrue
                                  Требования

                                  There are many representations for units of measure and in many contexts, particular representations are fixed and required. I.e. mcg for micrograms.

                                  Инвариантыele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
                                  930. Observation.component:lesionLength.value[x].system
                                  Определение

                                  The identification of the system that provides the coded form of the unit.

                                  КороткийSystem that defines coded unit form
                                  Контроль1..1
                                  На этот элемент влияют следующие инварианты: qty-3
                                  Типuri
                                  Модификаторfalse
                                  Примитивное значениеЭтот примитивный элемент может присутствовать или отсутствовать, или быть замененным расширением
                                  Summarytrue
                                  Требования

                                  Need to know the system that defines the coded form of the unit.

                                  Инвариантыele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
                                  932. Observation.component:lesionLength.value[x].code
                                  Определение

                                  A computer processable form of the unit in some unit representation system.

                                  КороткийCoded form of the unit
                                  Комментарии

                                  The preferred system is UCUM, but SNOMED CT can also be used (for customary units) or ISO 4217 for currency. The context of use may additionally require a code from a particular system.

                                  Контроль1..1
                                  На этот элемент влияют следующие инварианты: qty-3
                                  Типcode
                                  Модификаторfalse
                                  Примитивное значениеЭтот примитивный элемент может присутствовать или отсутствовать, или быть замененным расширением
                                  Summarytrue
                                  Требования

                                  Need a computable form of the unit that is fixed across all forms. UCUM provides this for quantities, but SNOMED CT provides many units of interest.

                                  Инвариантыele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
                                  934. Observation.component:lesionLength.dataAbsentReason
                                  Определение

                                  Provides a reason why the expected value in the element Observation.component.value[x] is missing.

                                  КороткийWhy the component result is missing
                                  Комментарии

                                  "Null" or exceptional values can be represented two ways in FHIR Observations. One way is to simply include them in the value set and represent the exceptions in the value. For example, measurement values for a serology test could be "detected", "not detected", "inconclusive", or "test not done".

                                  The alternate way is to use the value element for actual observations and use the explicit dataAbsentReason element to record exceptional values. For example, the dataAbsentReason code "error" could be used when the measurement was not completed. Because of these options, use-case agreements are required to interpret general observations for exceptional values.

                                  Контроль0..1
                                  ПривязкаЕсли они не подходят, эти коды ДОЛЖНЫ быть взяты из DataAbsentReasonVS (0.12.0)
                                  (extensible to https://terminology.dhp.uz/fhir/core/ValueSet/data-absent-reason-vs|0.12.0)
                                  ТипCodeableConcept
                                  Модификаторfalse
                                  Требуется поддержкаfalse
                                  Summaryfalse
                                  Требования

                                  For many results it is necessary to handle exceptional values in measurements.

                                  Инвариантыele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
                                  936. Observation.component:lesionLength.interpretation
                                  Определение

                                  A categorical assessment of an observation value. For example, high, low, normal.

                                  КороткийHigh, low, normal, etc
                                  Комментарии

                                  Historically used for laboratory results (known as 'abnormal flag' ), its use extends to other use cases where coded interpretations are relevant. Often reported as one or more simple compact codes this element is often placed adjacent to the result value in reports and flow sheets to signal the meaning/normalcy status of the result.

                                  Контроль0..*
                                  ПривязкаЕсли они не подходят, эти коды ДОЛЖНЫ быть взяты из ObservationInterpretationVS (0.12.0)
                                  (extensible to https://terminology.dhp.uz/fhir/core/ValueSet/observation-interpretation-vs|0.12.0)
                                  ТипCodeableConcept
                                  Модификаторfalse
                                  Требуется поддержкаfalse
                                  Summaryfalse
                                  Требования

                                  For some results, particularly numeric results, an interpretation is necessary to fully understand the significance of a result.

                                  Альтернативные именаAbnormal Flag
                                  Инвариантыele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
                                  938. Observation.component:lesionLength.referenceRange
                                  Определение

                                  Guidance on how to interpret the value by comparison to a normal or recommended range.

                                  КороткийProvides guide for interpretation of component result
                                  Комментарии

                                  Most observations only have one generic reference range. Systems MAY choose to restrict to only supplying the relevant reference range based on knowledge about the patient (e.g., specific to the patient's age, gender, weight and other factors), but this might not be possible or appropriate. Whenever more than one reference range is supplied, the differences between them SHOULD be provided in the reference range and/or age properties.

                                  Контроль0..*
                                  ТипСмотретьttp://hl7.org/fhir/StructureDefinition/Observation#Observation.referenceRange
                                  Модификаторfalse
                                  Требуется поддержкаfalse
                                  Summaryfalse
                                  Требования

                                  Knowing what values are considered "normal" can help evaluate the significance of a particular result. Need to be able to provide multiple reference ranges for different contexts.

                                  Инвариантыele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
                                  940. Observation.component:lesionWidth
                                  Название разрезаlesionWidth
                                  Определение

                                  Some observations have multiple component observations. These component observations are expressed as separate code value pairs that share the same attributes. Examples include systolic and diastolic component observations for blood pressure measurement and multiple component observations for genetics observations.

                                  КороткийLesion width
                                  Комментарии

                                  For a discussion on the ways Observations can be assembled in groups together see Notes below.

                                  Контроль0..1
                                  На этот элемент влияют следующие инварианты: obs-7
                                  ТипBackboneElement
                                  Модификаторfalse
                                  Требуется поддержкаtrue
                                  Summarytrue
                                  Требования

                                  Component observations share the same attributes in the Observation resource as the primary observation and are always treated a part of a single observation (they are not separable). However, the reference range for the primary observation value is not inherited by the component values and is required when appropriate for each component observation.

                                  Инвариантыele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
                                  942. Observation.component:lesionWidth.id
                                  Определение

                                  Unique id for the element within a resource (for internal references). This may be any string value that does not contain spaces.

                                  КороткийUnique id for inter-element referencing
                                  Контроль0..1
                                  На этот элемент влияют следующие инварианты: ele-1
                                  Типstring
                                  Модификаторfalse
                                  Формат XMLВ формате XML это свойство представлено в качестве атрибута.
                                  Summaryfalse
                                  944. Observation.component:lesionWidth.extension
                                  Определение

                                  May be used to represent additional information that is not part of the basic definition of the element. To make the use of extensions safe and managable, there is a strict set of governance applied to the definition and use of extensions. Though any implementer can define an extension, there is a set of requirements that SHALL be met as part of the definition of the extension.

                                  КороткийAdditional content defined by implementations
                                  Комментарии

                                  There can be no stigma associated with the use of extensions by any application, project, or standard - regardless of the institution or jurisdiction that uses or defines the extensions. The use of extensions is what allows the FHIR specification to retain a core level of simplicity for everyone.

                                  Контроль0..*
                                  ТипExtension
                                  Модификаторfalse
                                  Summaryfalse
                                  Альтернативные именаextensions, user content
                                  Инвариантыele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
                                  ext-1: Must have either extensions or value[x], not both (extension.exists() != value.exists())
                                  946. Observation.component:lesionWidth.modifierExtension
                                  Определение

                                  May be used to represent additional information that is not part of the basic definition of the element and that modifies the understanding of the element in which it is contained and/or the understanding of the containing element's descendants. Usually modifier elements provide negation or qualification. To make the use of extensions safe and managable, there is a strict set of governance applied to the definition and use of extensions. Though any implementer can define an extension, there is a set of requirements that SHALL be met as part of the definition of the extension. Applications processing a resource are required to check for modifier extensions.

                                  Modifier extensions SHALL NOT change the meaning of any elements on Resource or DomainResource (including cannot change the meaning of modifierExtension itself).

                                  КороткийExtensions that cannot be ignored even if unrecognized
                                  Комментарии

                                  There can be no stigma associated with the use of extensions by any application, project, or standard - regardless of the institution or jurisdiction that uses or defines the extensions. The use of extensions is what allows the FHIR specification to retain a core level of simplicity for everyone.

                                  Контроль0..*
                                  ТипExtension
                                  Модификаторtrue потому что Modifier extensions are expected to modify the meaning or interpretation of the element that contains them
                                  Summarytrue
                                  Требования

                                  Modifier extensions allow for extensions that cannot be safely ignored to be clearly distinguished from the vast majority of extensions which can be safely ignored. This promotes interoperability by eliminating the need for implementers to prohibit the presence of extensions. For further information, see the definition of modifier extensions.

                                  Альтернативные именаextensions, user content, modifiers
                                  Инвариантыele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
                                  ext-1: Must have either extensions or value[x], not both (extension.exists() != value.exists())
                                  948. Observation.component:lesionWidth.code
                                  Определение

                                  Describes what was observed. Sometimes this is called the observation "code".

                                  КороткийType of component observation (code / type)
                                  Комментарии

                                  All code-value and component.code-component.value pairs need to be taken into account to correctly understand the meaning of the observation.

                                  Контроль1..1
                                  На этот элемент влияют следующие инварианты: obs-7
                                  ПривязкаКоды СЛЕДУЕТ взять из ObservationCodesVS (0.12.0)
                                  (preferred to https://terminology.dhp.uz/fhir/core/ValueSet/observation-codes-vs|0.12.0)
                                  ТипCodeableConcept
                                  Модификаторfalse
                                  Требуется поддержкаtrue
                                  Summarytrue
                                  Требования

                                  Knowing what kind of observation is being made is essential to understanding the observation.

                                  Значение шаблона{
                                    "coding" : [{
                                      "system" : "https://terminology.dhp.uz/fhir/integrations/CodeSystem/screening-ultrasound-parameter-cs",
                                      "code" : "scrn-0052-00025"
                                    }]
                                  }
                                  Инвариантыele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
                                  950. Observation.component:lesionWidth.value[x]
                                  Определение

                                  The information determined as a result of making the observation, if the information has a simple value.

                                  КороткийActual component result
                                  Комментарии

                                  Used when observation has a set of component observations:

                                  • An observation may have both a value (e.g. an Apgar score) and component observations (the observations from which the Apgar score was derived).
                                  • If a value is present, the datatype for this element should be determined by the code.
                                  • CodeableConcept with just a text would be used instead of a string if the field was usually coded, or if the type associated with the code defines a coded value.
                                  • Attachment is used if the observation result value is a binary file such as an image. If the observation result value is derived from the binary file (for example 'X' detected and here is the the proof in this image), the binary file may be directly represented using DocumentReference and referenced by derivedFrom.
                                  • If a value is present, the datatype for this element should be determined by the code.
                                  • CodeableConcept with just a text would be used instead of a string if the field was usually coded, or if the type associated with the code defines a coded value.
                                  • Attachment is used if the observation result value is a binary file such as an image. If the observation result value is derived from the binary file (for example 'X' detected and here is the the proof in this image), the binary file may be directly represented using DocumentReference and referenced by derivedFrom.
                                  • The usage of valueReference is restricted to the MolecularSequence resource when used as a definitional resource, not as a patient-specific finding. .
                                  • For additional guidance, see the Notes section below.
                                  Контроль1..1
                                  ТипQuantity
                                  [x] ЗаметкаСмотретьВыбор типов данныхдля дополнительной информации о том, как использовать [x]
                                  Модификаторfalse
                                  Требуется поддержкаtrue
                                  Summarytrue
                                  Требования

                                  An observation exists to have a value, though it might not if it is in error, or if it represents a group of observations.

                                  Значение шаблона{
                                    "unit" : "mm",
                                    "system" : "http://unitsofmeasure.org",
                                    "code" : "mm"
                                  }
                                  Инвариантыele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
                                  952. Observation.component:lesionWidth.value[x].id
                                  Определение

                                  Unique id for the element within a resource (for internal references). This may be any string value that does not contain spaces.

                                  КороткийUnique id for inter-element referencing
                                  Контроль0..1
                                  На этот элемент влияют следующие инварианты: ele-1
                                  Типid
                                  Модификаторfalse
                                  Формат XMLВ формате XML это свойство представлено в качестве атрибута.
                                  Summaryfalse
                                  954. Observation.component:lesionWidth.value[x].extension
                                  Определение

                                  May be used to represent additional information that is not part of the basic definition of the element. To make the use of extensions safe and managable, there is a strict set of governance applied to the definition and use of extensions. Though any implementer can define an extension, there is a set of requirements that SHALL be met as part of the definition of the extension.

                                  КороткийAdditional content defined by implementations
                                  Комментарии

                                  There can be no stigma associated with the use of extensions by any application, project, or standard - regardless of the institution or jurisdiction that uses or defines the extensions. The use of extensions is what allows the FHIR specification to retain a core level of simplicity for everyone.

                                  Контроль0..*
                                  ТипExtension
                                  Модификаторfalse
                                  Summaryfalse
                                  Альтернативные именаextensions, user content
                                  Инвариантыele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
                                  ext-1: Must have either extensions or value[x], not both (extension.exists() != value.exists())
                                  SlicingЭтот элемент представляет набор разрезов на Observation.component.value[x].extension. Разрезы бываютНе упорядочено и Open, и могут быть дифференцированы с помощью следующих дискриминаторов:
                                  • value @ url
                                  • 956. Observation.component:lesionWidth.value[x].value
                                    Определение

                                    The value of the measured amount. The value includes an implicit precision in the presentation of the value.

                                    КороткийNumerical value (with implicit precision)
                                    Комментарии

                                    The implicit precision in the value should always be honored. Monetary values have their own rules for handling precision (refer to standard accounting text books).

                                    Контроль1..1
                                    Типdecimal
                                    Модификаторfalse
                                    Примитивное значениеЭтот примитивный элемент может присутствовать или отсутствовать, или быть замененным расширением
                                    Summarytrue
                                    Требования

                                    Precision is handled implicitly in almost all cases of measurement.

                                    Мин. значение0
                                    Инвариантыele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
                                    958. Observation.component:lesionWidth.value[x].comparator
                                    Определение

                                    How the value should be understood and represented - whether the actual value is greater or less than the stated value due to measurement issues; e.g. if the comparator is "<" , then the real value is < stated value.

                                    Короткий< | <= | >= | > | ad - how to understand the value
                                    Контроль0..1
                                    ПривязкаКоды ДОЛЖНЫ быть взяты из QuantityComparator
                                    (required to http://hl7.org/fhir/ValueSet/quantity-comparator|5.0.0)

                                    How the Quantity should be understood and represented.

                                    Типcode
                                    Модификаторtrue потому что This is labeled as "Is Modifier" because the comparator modifies the interpretation of the value significantly. If there is no comparator, then there is no modification of the value
                                    Примитивное значениеЭтот примитивный элемент может присутствовать или отсутствовать, или быть замененным расширением
                                    Summarytrue
                                    Требования

                                    Need a framework for handling measures where the value is <5ug/L or >400mg/L due to the limitations of measuring methodology.

                                    Значение при отсутствииIf there is no comparator, then there is no modification of the value
                                    Инвариантыele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
                                    960. Observation.component:lesionWidth.value[x].unit
                                    Определение

                                    A human-readable form of the unit.

                                    КороткийUnit representation
                                    Контроль1..1
                                    Типstring
                                    Модификаторfalse
                                    Примитивное значениеЭтот примитивный элемент может присутствовать или отсутствовать, или быть замененным расширением
                                    Summarytrue
                                    Требования

                                    There are many representations for units of measure and in many contexts, particular representations are fixed and required. I.e. mcg for micrograms.

                                    Инвариантыele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
                                    962. Observation.component:lesionWidth.value[x].system
                                    Определение

                                    The identification of the system that provides the coded form of the unit.

                                    КороткийSystem that defines coded unit form
                                    Контроль1..1
                                    На этот элемент влияют следующие инварианты: qty-3
                                    Типuri
                                    Модификаторfalse
                                    Примитивное значениеЭтот примитивный элемент может присутствовать или отсутствовать, или быть замененным расширением
                                    Summarytrue
                                    Требования

                                    Need to know the system that defines the coded form of the unit.

                                    Инвариантыele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
                                    964. Observation.component:lesionWidth.value[x].code
                                    Определение

                                    A computer processable form of the unit in some unit representation system.

                                    КороткийCoded form of the unit
                                    Комментарии

                                    The preferred system is UCUM, but SNOMED CT can also be used (for customary units) or ISO 4217 for currency. The context of use may additionally require a code from a particular system.

                                    Контроль1..1
                                    На этот элемент влияют следующие инварианты: qty-3
                                    Типcode
                                    Модификаторfalse
                                    Примитивное значениеЭтот примитивный элемент может присутствовать или отсутствовать, или быть замененным расширением
                                    Summarytrue
                                    Требования

                                    Need a computable form of the unit that is fixed across all forms. UCUM provides this for quantities, but SNOMED CT provides many units of interest.

                                    Инвариантыele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
                                    966. Observation.component:lesionWidth.dataAbsentReason
                                    Определение

                                    Provides a reason why the expected value in the element Observation.component.value[x] is missing.

                                    КороткийWhy the component result is missing
                                    Комментарии

                                    "Null" or exceptional values can be represented two ways in FHIR Observations. One way is to simply include them in the value set and represent the exceptions in the value. For example, measurement values for a serology test could be "detected", "not detected", "inconclusive", or "test not done".

                                    The alternate way is to use the value element for actual observations and use the explicit dataAbsentReason element to record exceptional values. For example, the dataAbsentReason code "error" could be used when the measurement was not completed. Because of these options, use-case agreements are required to interpret general observations for exceptional values.

                                    Контроль0..1
                                    ПривязкаЕсли они не подходят, эти коды ДОЛЖНЫ быть взяты из DataAbsentReasonVS (0.12.0)
                                    (extensible to https://terminology.dhp.uz/fhir/core/ValueSet/data-absent-reason-vs|0.12.0)
                                    ТипCodeableConcept
                                    Модификаторfalse
                                    Требуется поддержкаfalse
                                    Summaryfalse
                                    Требования

                                    For many results it is necessary to handle exceptional values in measurements.

                                    Инвариантыele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
                                    968. Observation.component:lesionWidth.interpretation
                                    Определение

                                    A categorical assessment of an observation value. For example, high, low, normal.

                                    КороткийHigh, low, normal, etc
                                    Комментарии

                                    Historically used for laboratory results (known as 'abnormal flag' ), its use extends to other use cases where coded interpretations are relevant. Often reported as one or more simple compact codes this element is often placed adjacent to the result value in reports and flow sheets to signal the meaning/normalcy status of the result.

                                    Контроль0..*
                                    ПривязкаЕсли они не подходят, эти коды ДОЛЖНЫ быть взяты из ObservationInterpretationVS (0.12.0)
                                    (extensible to https://terminology.dhp.uz/fhir/core/ValueSet/observation-interpretation-vs|0.12.0)
                                    ТипCodeableConcept
                                    Модификаторfalse
                                    Требуется поддержкаfalse
                                    Summaryfalse
                                    Требования

                                    For some results, particularly numeric results, an interpretation is necessary to fully understand the significance of a result.

                                    Альтернативные именаAbnormal Flag
                                    Инвариантыele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
                                    970. Observation.component:lesionWidth.referenceRange
                                    Определение

                                    Guidance on how to interpret the value by comparison to a normal or recommended range.

                                    КороткийProvides guide for interpretation of component result
                                    Комментарии

                                    Most observations only have one generic reference range. Systems MAY choose to restrict to only supplying the relevant reference range based on knowledge about the patient (e.g., specific to the patient's age, gender, weight and other factors), but this might not be possible or appropriate. Whenever more than one reference range is supplied, the differences between them SHOULD be provided in the reference range and/or age properties.

                                    Контроль0..*
                                    ТипСмотретьttp://hl7.org/fhir/StructureDefinition/Observation#Observation.referenceRange
                                    Модификаторfalse
                                    Требуется поддержкаfalse
                                    Summaryfalse
                                    Требования

                                    Knowing what values are considered "normal" can help evaluate the significance of a particular result. Need to be able to provide multiple reference ranges for different contexts.

                                    Инвариантыele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
                                    972. Observation.component:lesionThickness
                                    Название разрезаlesionThickness
                                    Определение

                                    Some observations have multiple component observations. These component observations are expressed as separate code value pairs that share the same attributes. Examples include systolic and diastolic component observations for blood pressure measurement and multiple component observations for genetics observations.

                                    КороткийLesion thickness
                                    Комментарии

                                    For a discussion on the ways Observations can be assembled in groups together see Notes below.

                                    Контроль0..1
                                    На этот элемент влияют следующие инварианты: obs-7
                                    ТипBackboneElement
                                    Модификаторfalse
                                    Требуется поддержкаtrue
                                    Summarytrue
                                    Требования

                                    Component observations share the same attributes in the Observation resource as the primary observation and are always treated a part of a single observation (they are not separable). However, the reference range for the primary observation value is not inherited by the component values and is required when appropriate for each component observation.

                                    Инвариантыele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
                                    974. Observation.component:lesionThickness.id
                                    Определение

                                    Unique id for the element within a resource (for internal references). This may be any string value that does not contain spaces.

                                    КороткийUnique id for inter-element referencing
                                    Контроль0..1
                                    На этот элемент влияют следующие инварианты: ele-1
                                    Типstring
                                    Модификаторfalse
                                    Формат XMLВ формате XML это свойство представлено в качестве атрибута.
                                    Summaryfalse
                                    976. Observation.component:lesionThickness.extension
                                    Определение

                                    May be used to represent additional information that is not part of the basic definition of the element. To make the use of extensions safe and managable, there is a strict set of governance applied to the definition and use of extensions. Though any implementer can define an extension, there is a set of requirements that SHALL be met as part of the definition of the extension.

                                    КороткийAdditional content defined by implementations
                                    Комментарии

                                    There can be no stigma associated with the use of extensions by any application, project, or standard - regardless of the institution or jurisdiction that uses or defines the extensions. The use of extensions is what allows the FHIR specification to retain a core level of simplicity for everyone.

                                    Контроль0..*
                                    ТипExtension
                                    Модификаторfalse
                                    Summaryfalse
                                    Альтернативные именаextensions, user content
                                    Инвариантыele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
                                    ext-1: Must have either extensions or value[x], not both (extension.exists() != value.exists())
                                    978. Observation.component:lesionThickness.modifierExtension
                                    Определение

                                    May be used to represent additional information that is not part of the basic definition of the element and that modifies the understanding of the element in which it is contained and/or the understanding of the containing element's descendants. Usually modifier elements provide negation or qualification. To make the use of extensions safe and managable, there is a strict set of governance applied to the definition and use of extensions. Though any implementer can define an extension, there is a set of requirements that SHALL be met as part of the definition of the extension. Applications processing a resource are required to check for modifier extensions.

                                    Modifier extensions SHALL NOT change the meaning of any elements on Resource or DomainResource (including cannot change the meaning of modifierExtension itself).

                                    КороткийExtensions that cannot be ignored even if unrecognized
                                    Комментарии

                                    There can be no stigma associated with the use of extensions by any application, project, or standard - regardless of the institution or jurisdiction that uses or defines the extensions. The use of extensions is what allows the FHIR specification to retain a core level of simplicity for everyone.

                                    Контроль0..*
                                    ТипExtension
                                    Модификаторtrue потому что Modifier extensions are expected to modify the meaning or interpretation of the element that contains them
                                    Summarytrue
                                    Требования

                                    Modifier extensions allow for extensions that cannot be safely ignored to be clearly distinguished from the vast majority of extensions which can be safely ignored. This promotes interoperability by eliminating the need for implementers to prohibit the presence of extensions. For further information, see the definition of modifier extensions.

                                    Альтернативные именаextensions, user content, modifiers
                                    Инвариантыele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
                                    ext-1: Must have either extensions or value[x], not both (extension.exists() != value.exists())
                                    980. Observation.component:lesionThickness.code
                                    Определение

                                    Describes what was observed. Sometimes this is called the observation "code".

                                    КороткийType of component observation (code / type)
                                    Комментарии

                                    All code-value and component.code-component.value pairs need to be taken into account to correctly understand the meaning of the observation.

                                    Контроль1..1
                                    На этот элемент влияют следующие инварианты: obs-7
                                    ПривязкаКоды СЛЕДУЕТ взять из ObservationCodesVS (0.12.0)
                                    (preferred to https://terminology.dhp.uz/fhir/core/ValueSet/observation-codes-vs|0.12.0)
                                    ТипCodeableConcept
                                    Модификаторfalse
                                    Требуется поддержкаtrue
                                    Summarytrue
                                    Требования

                                    Knowing what kind of observation is being made is essential to understanding the observation.

                                    Значение шаблона{
                                      "coding" : [{
                                        "system" : "https://terminology.dhp.uz/fhir/integrations/CodeSystem/screening-ultrasound-parameter-cs",
                                        "code" : "scrn-0052-00026"
                                      }]
                                    }
                                    Инвариантыele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
                                    982. Observation.component:lesionThickness.value[x]
                                    Определение

                                    The information determined as a result of making the observation, if the information has a simple value.

                                    КороткийActual component result
                                    Комментарии

                                    Used when observation has a set of component observations:

                                    • An observation may have both a value (e.g. an Apgar score) and component observations (the observations from which the Apgar score was derived).
                                    • If a value is present, the datatype for this element should be determined by the code.
                                    • CodeableConcept with just a text would be used instead of a string if the field was usually coded, or if the type associated with the code defines a coded value.
                                    • Attachment is used if the observation result value is a binary file such as an image. If the observation result value is derived from the binary file (for example 'X' detected and here is the the proof in this image), the binary file may be directly represented using DocumentReference and referenced by derivedFrom.
                                    • If a value is present, the datatype for this element should be determined by the code.
                                    • CodeableConcept with just a text would be used instead of a string if the field was usually coded, or if the type associated with the code defines a coded value.
                                    • Attachment is used if the observation result value is a binary file such as an image. If the observation result value is derived from the binary file (for example 'X' detected and here is the the proof in this image), the binary file may be directly represented using DocumentReference and referenced by derivedFrom.
                                    • The usage of valueReference is restricted to the MolecularSequence resource when used as a definitional resource, not as a patient-specific finding. .
                                    • For additional guidance, see the Notes section below.
                                    Контроль1..1
                                    ТипQuantity
                                    [x] ЗаметкаСмотретьВыбор типов данныхдля дополнительной информации о том, как использовать [x]
                                    Модификаторfalse
                                    Требуется поддержкаtrue
                                    Summarytrue
                                    Требования

                                    An observation exists to have a value, though it might not if it is in error, or if it represents a group of observations.

                                    Значение шаблона{
                                      "unit" : "mm",
                                      "system" : "http://unitsofmeasure.org",
                                      "code" : "mm"
                                    }
                                    Инвариантыele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
                                    984. Observation.component:lesionThickness.value[x].id
                                    Определение

                                    Unique id for the element within a resource (for internal references). This may be any string value that does not contain spaces.

                                    КороткийUnique id for inter-element referencing
                                    Контроль0..1
                                    На этот элемент влияют следующие инварианты: ele-1
                                    Типid
                                    Модификаторfalse
                                    Формат XMLВ формате XML это свойство представлено в качестве атрибута.
                                    Summaryfalse
                                    986. Observation.component:lesionThickness.value[x].extension
                                    Определение

                                    May be used to represent additional information that is not part of the basic definition of the element. To make the use of extensions safe and managable, there is a strict set of governance applied to the definition and use of extensions. Though any implementer can define an extension, there is a set of requirements that SHALL be met as part of the definition of the extension.

                                    КороткийAdditional content defined by implementations
                                    Комментарии

                                    There can be no stigma associated with the use of extensions by any application, project, or standard - regardless of the institution or jurisdiction that uses or defines the extensions. The use of extensions is what allows the FHIR specification to retain a core level of simplicity for everyone.

                                    Контроль0..*
                                    ТипExtension
                                    Модификаторfalse
                                    Summaryfalse
                                    Альтернативные именаextensions, user content
                                    Инвариантыele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
                                    ext-1: Must have either extensions or value[x], not both (extension.exists() != value.exists())
                                    SlicingЭтот элемент представляет набор разрезов на Observation.component.value[x].extension. Разрезы бываютНе упорядочено и Open, и могут быть дифференцированы с помощью следующих дискриминаторов:
                                    • value @ url
                                    • 988. Observation.component:lesionThickness.value[x].value
                                      Определение

                                      The value of the measured amount. The value includes an implicit precision in the presentation of the value.

                                      КороткийNumerical value (with implicit precision)
                                      Комментарии

                                      The implicit precision in the value should always be honored. Monetary values have their own rules for handling precision (refer to standard accounting text books).

                                      Контроль1..1
                                      Типdecimal
                                      Модификаторfalse
                                      Примитивное значениеЭтот примитивный элемент может присутствовать или отсутствовать, или быть замененным расширением
                                      Summarytrue
                                      Требования

                                      Precision is handled implicitly in almost all cases of measurement.

                                      Мин. значение0
                                      Инвариантыele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
                                      990. Observation.component:lesionThickness.value[x].comparator
                                      Определение

                                      How the value should be understood and represented - whether the actual value is greater or less than the stated value due to measurement issues; e.g. if the comparator is "<" , then the real value is < stated value.

                                      Короткий< | <= | >= | > | ad - how to understand the value
                                      Контроль0..1
                                      ПривязкаКоды ДОЛЖНЫ быть взяты из QuantityComparator
                                      (required to http://hl7.org/fhir/ValueSet/quantity-comparator|5.0.0)

                                      How the Quantity should be understood and represented.

                                      Типcode
                                      Модификаторtrue потому что This is labeled as "Is Modifier" because the comparator modifies the interpretation of the value significantly. If there is no comparator, then there is no modification of the value
                                      Примитивное значениеЭтот примитивный элемент может присутствовать или отсутствовать, или быть замененным расширением
                                      Summarytrue
                                      Требования

                                      Need a framework for handling measures where the value is <5ug/L or >400mg/L due to the limitations of measuring methodology.

                                      Значение при отсутствииIf there is no comparator, then there is no modification of the value
                                      Инвариантыele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
                                      992. Observation.component:lesionThickness.value[x].unit
                                      Определение

                                      A human-readable form of the unit.

                                      КороткийUnit representation
                                      Контроль1..1
                                      Типstring
                                      Модификаторfalse
                                      Примитивное значениеЭтот примитивный элемент может присутствовать или отсутствовать, или быть замененным расширением
                                      Summarytrue
                                      Требования

                                      There are many representations for units of measure and in many contexts, particular representations are fixed and required. I.e. mcg for micrograms.

                                      Инвариантыele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
                                      994. Observation.component:lesionThickness.value[x].system
                                      Определение

                                      The identification of the system that provides the coded form of the unit.

                                      КороткийSystem that defines coded unit form
                                      Контроль1..1
                                      На этот элемент влияют следующие инварианты: qty-3
                                      Типuri
                                      Модификаторfalse
                                      Примитивное значениеЭтот примитивный элемент может присутствовать или отсутствовать, или быть замененным расширением
                                      Summarytrue
                                      Требования

                                      Need to know the system that defines the coded form of the unit.

                                      Инвариантыele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
                                      996. Observation.component:lesionThickness.value[x].code
                                      Определение

                                      A computer processable form of the unit in some unit representation system.

                                      КороткийCoded form of the unit
                                      Комментарии

                                      The preferred system is UCUM, but SNOMED CT can also be used (for customary units) or ISO 4217 for currency. The context of use may additionally require a code from a particular system.

                                      Контроль1..1
                                      На этот элемент влияют следующие инварианты: qty-3
                                      Типcode
                                      Модификаторfalse
                                      Примитивное значениеЭтот примитивный элемент может присутствовать или отсутствовать, или быть замененным расширением
                                      Summarytrue
                                      Требования

                                      Need a computable form of the unit that is fixed across all forms. UCUM provides this for quantities, but SNOMED CT provides many units of interest.

                                      Инвариантыele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
                                      998. Observation.component:lesionThickness.dataAbsentReason
                                      Определение

                                      Provides a reason why the expected value in the element Observation.component.value[x] is missing.

                                      КороткийWhy the component result is missing
                                      Комментарии

                                      "Null" or exceptional values can be represented two ways in FHIR Observations. One way is to simply include them in the value set and represent the exceptions in the value. For example, measurement values for a serology test could be "detected", "not detected", "inconclusive", or "test not done".

                                      The alternate way is to use the value element for actual observations and use the explicit dataAbsentReason element to record exceptional values. For example, the dataAbsentReason code "error" could be used when the measurement was not completed. Because of these options, use-case agreements are required to interpret general observations for exceptional values.

                                      Контроль0..1
                                      ПривязкаЕсли они не подходят, эти коды ДОЛЖНЫ быть взяты из DataAbsentReasonVS (0.12.0)
                                      (extensible to https://terminology.dhp.uz/fhir/core/ValueSet/data-absent-reason-vs|0.12.0)
                                      ТипCodeableConcept
                                      Модификаторfalse
                                      Требуется поддержкаfalse
                                      Summaryfalse
                                      Требования

                                      For many results it is necessary to handle exceptional values in measurements.

                                      Инвариантыele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
                                      1000. Observation.component:lesionThickness.interpretation
                                      Определение

                                      A categorical assessment of an observation value. For example, high, low, normal.

                                      КороткийHigh, low, normal, etc
                                      Комментарии

                                      Historically used for laboratory results (known as 'abnormal flag' ), its use extends to other use cases where coded interpretations are relevant. Often reported as one or more simple compact codes this element is often placed adjacent to the result value in reports and flow sheets to signal the meaning/normalcy status of the result.

                                      Контроль0..*
                                      ПривязкаЕсли они не подходят, эти коды ДОЛЖНЫ быть взяты из ObservationInterpretationVS (0.12.0)
                                      (extensible to https://terminology.dhp.uz/fhir/core/ValueSet/observation-interpretation-vs|0.12.0)
                                      ТипCodeableConcept
                                      Модификаторfalse
                                      Требуется поддержкаfalse
                                      Summaryfalse
                                      Требования

                                      For some results, particularly numeric results, an interpretation is necessary to fully understand the significance of a result.

                                      Альтернативные именаAbnormal Flag
                                      Инвариантыele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
                                      1002. Observation.component:lesionThickness.referenceRange
                                      Определение

                                      Guidance on how to interpret the value by comparison to a normal or recommended range.

                                      КороткийProvides guide for interpretation of component result
                                      Комментарии

                                      Most observations only have one generic reference range. Systems MAY choose to restrict to only supplying the relevant reference range based on knowledge about the patient (e.g., specific to the patient's age, gender, weight and other factors), but this might not be possible or appropriate. Whenever more than one reference range is supplied, the differences between them SHOULD be provided in the reference range and/or age properties.

                                      Контроль0..*
                                      ТипСмотретьttp://hl7.org/fhir/StructureDefinition/Observation#Observation.referenceRange
                                      Модификаторfalse
                                      Требуется поддержкаfalse
                                      Summaryfalse
                                      Требования

                                      Knowing what values are considered "normal" can help evaluate the significance of a particular result. Need to be able to provide multiple reference ranges for different contexts.

                                      Инвариантыele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
                                      1004. Observation.component:internalStructureHomogeneous
                                      Название разрезаinternalStructureHomogeneous
                                      Определение

                                      Some observations have multiple component observations. These component observations are expressed as separate code value pairs that share the same attributes. Examples include systolic and diastolic component observations for blood pressure measurement and multiple component observations for genetics observations.

                                      КороткийComponent results
                                      Комментарии

                                      For a discussion on the ways Observations can be assembled in groups together see Notes below.

                                      Контроль0..1
                                      На этот элемент влияют следующие инварианты: obs-7
                                      ТипBackboneElement
                                      Модификаторfalse
                                      Требуется поддержкаtrue
                                      Summarytrue
                                      Требования

                                      Component observations share the same attributes in the Observation resource as the primary observation and are always treated a part of a single observation (they are not separable). However, the reference range for the primary observation value is not inherited by the component values and is required when appropriate for each component observation.

                                      Инвариантыele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
                                      1006. Observation.component:internalStructureHomogeneous.id
                                      Определение

                                      Unique id for the element within a resource (for internal references). This may be any string value that does not contain spaces.

                                      КороткийUnique id for inter-element referencing
                                      Контроль0..1
                                      На этот элемент влияют следующие инварианты: ele-1
                                      Типstring
                                      Модификаторfalse
                                      Формат XMLВ формате XML это свойство представлено в качестве атрибута.
                                      Summaryfalse
                                      1008. Observation.component:internalStructureHomogeneous.extension
                                      Определение

                                      May be used to represent additional information that is not part of the basic definition of the element. To make the use of extensions safe and managable, there is a strict set of governance applied to the definition and use of extensions. Though any implementer can define an extension, there is a set of requirements that SHALL be met as part of the definition of the extension.

                                      КороткийAdditional content defined by implementations
                                      Комментарии

                                      There can be no stigma associated with the use of extensions by any application, project, or standard - regardless of the institution or jurisdiction that uses or defines the extensions. The use of extensions is what allows the FHIR specification to retain a core level of simplicity for everyone.

                                      Контроль0..*
                                      ТипExtension
                                      Модификаторfalse
                                      Summaryfalse
                                      Альтернативные именаextensions, user content
                                      Инвариантыele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
                                      ext-1: Must have either extensions or value[x], not both (extension.exists() != value.exists())
                                      1010. Observation.component:internalStructureHomogeneous.modifierExtension
                                      Определение

                                      May be used to represent additional information that is not part of the basic definition of the element and that modifies the understanding of the element in which it is contained and/or the understanding of the containing element's descendants. Usually modifier elements provide negation or qualification. To make the use of extensions safe and managable, there is a strict set of governance applied to the definition and use of extensions. Though any implementer can define an extension, there is a set of requirements that SHALL be met as part of the definition of the extension. Applications processing a resource are required to check for modifier extensions.

                                      Modifier extensions SHALL NOT change the meaning of any elements on Resource or DomainResource (including cannot change the meaning of modifierExtension itself).

                                      КороткийExtensions that cannot be ignored even if unrecognized
                                      Комментарии

                                      There can be no stigma associated with the use of extensions by any application, project, or standard - regardless of the institution or jurisdiction that uses or defines the extensions. The use of extensions is what allows the FHIR specification to retain a core level of simplicity for everyone.

                                      Контроль0..*
                                      ТипExtension
                                      Модификаторtrue потому что Modifier extensions are expected to modify the meaning or interpretation of the element that contains them
                                      Summarytrue
                                      Требования

                                      Modifier extensions allow for extensions that cannot be safely ignored to be clearly distinguished from the vast majority of extensions which can be safely ignored. This promotes interoperability by eliminating the need for implementers to prohibit the presence of extensions. For further information, see the definition of modifier extensions.

                                      Альтернативные именаextensions, user content, modifiers
                                      Инвариантыele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
                                      ext-1: Must have either extensions or value[x], not both (extension.exists() != value.exists())
                                      1012. Observation.component:internalStructureHomogeneous.code
                                      Определение

                                      Describes what was observed. Sometimes this is called the observation "code".

                                      КороткийType of component observation (code / type)
                                      Комментарии

                                      All code-value and component.code-component.value pairs need to be taken into account to correctly understand the meaning of the observation.

                                      Контроль1..1
                                      На этот элемент влияют следующие инварианты: obs-7
                                      ПривязкаКоды СЛЕДУЕТ взять из ObservationCodesVS (0.12.0)
                                      (preferred to https://terminology.dhp.uz/fhir/core/ValueSet/observation-codes-vs|0.12.0)
                                      ТипCodeableConcept
                                      Модификаторfalse
                                      Требуется поддержкаtrue
                                      Summarytrue
                                      Требования

                                      Knowing what kind of observation is being made is essential to understanding the observation.

                                      Значение шаблона{
                                        "coding" : [{
                                          "system" : "https://terminology.dhp.uz/fhir/integrations/CodeSystem/screening-ultrasound-parameter-cs",
                                          "code" : "scrn-0052-00031"
                                        }]
                                      }
                                      Инвариантыele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
                                      1014. Observation.component:internalStructureHomogeneous.value[x]
                                      Определение

                                      The information determined as a result of making the observation, if the information has a simple value.

                                      КороткийActual component result
                                      Комментарии

                                      Used when observation has a set of component observations:

                                      • An observation may have both a value (e.g. an Apgar score) and component observations (the observations from which the Apgar score was derived).
                                      • If a value is present, the datatype for this element should be determined by the code.
                                      • CodeableConcept with just a text would be used instead of a string if the field was usually coded, or if the type associated with the code defines a coded value.
                                      • Attachment is used if the observation result value is a binary file such as an image. If the observation result value is derived from the binary file (for example 'X' detected and here is the the proof in this image), the binary file may be directly represented using DocumentReference and referenced by derivedFrom.
                                      • If a value is present, the datatype for this element should be determined by the code.
                                      • CodeableConcept with just a text would be used instead of a string if the field was usually coded, or if the type associated with the code defines a coded value.
                                      • Attachment is used if the observation result value is a binary file such as an image. If the observation result value is derived from the binary file (for example 'X' detected and here is the the proof in this image), the binary file may be directly represented using DocumentReference and referenced by derivedFrom.
                                      • The usage of valueReference is restricted to the MolecularSequence resource when used as a definitional resource, not as a patient-specific finding. .
                                      • For additional guidance, see the Notes section below.
                                      Контроль1..1
                                      Типboolean
                                      [x] ЗаметкаСмотретьВыбор типов данныхдля дополнительной информации о том, как использовать [x]
                                      Модификаторfalse
                                      Примитивное значениеЭтот примитивный элемент может присутствовать или отсутствовать, или быть замененным расширением
                                      Требуется поддержкаtrue
                                      Summarytrue
                                      Требования

                                      An observation exists to have a value, though it might not if it is in error, or if it represents a group of observations.

                                      Инвариантыele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
                                      1016. Observation.component:internalStructureHomogeneous.dataAbsentReason
                                      Определение

                                      Provides a reason why the expected value in the element Observation.component.value[x] is missing.

                                      КороткийWhy the component result is missing
                                      Комментарии

                                      "Null" or exceptional values can be represented two ways in FHIR Observations. One way is to simply include them in the value set and represent the exceptions in the value. For example, measurement values for a serology test could be "detected", "not detected", "inconclusive", or "test not done".

                                      The alternate way is to use the value element for actual observations and use the explicit dataAbsentReason element to record exceptional values. For example, the dataAbsentReason code "error" could be used when the measurement was not completed. Because of these options, use-case agreements are required to interpret general observations for exceptional values.

                                      Контроль0..1
                                      ПривязкаЕсли они не подходят, эти коды ДОЛЖНЫ быть взяты из DataAbsentReasonVS (0.12.0)
                                      (extensible to https://terminology.dhp.uz/fhir/core/ValueSet/data-absent-reason-vs|0.12.0)
                                      ТипCodeableConcept
                                      Модификаторfalse
                                      Требуется поддержкаfalse
                                      Summaryfalse
                                      Требования

                                      For many results it is necessary to handle exceptional values in measurements.

                                      Инвариантыele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
                                      1018. Observation.component:internalStructureHomogeneous.interpretation
                                      Определение

                                      A categorical assessment of an observation value. For example, high, low, normal.

                                      КороткийHigh, low, normal, etc
                                      Комментарии

                                      Historically used for laboratory results (known as 'abnormal flag' ), its use extends to other use cases where coded interpretations are relevant. Often reported as one or more simple compact codes this element is often placed adjacent to the result value in reports and flow sheets to signal the meaning/normalcy status of the result.

                                      Контроль0..*
                                      ПривязкаЕсли они не подходят, эти коды ДОЛЖНЫ быть взяты из ObservationInterpretationVS (0.12.0)
                                      (extensible to https://terminology.dhp.uz/fhir/core/ValueSet/observation-interpretation-vs|0.12.0)
                                      ТипCodeableConcept
                                      Модификаторfalse
                                      Требуется поддержкаfalse
                                      Summaryfalse
                                      Требования

                                      For some results, particularly numeric results, an interpretation is necessary to fully understand the significance of a result.

                                      Альтернативные именаAbnormal Flag
                                      Инвариантыele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
                                      1020. Observation.component:internalStructureHomogeneous.referenceRange
                                      Определение

                                      Guidance on how to interpret the value by comparison to a normal or recommended range.

                                      КороткийProvides guide for interpretation of component result
                                      Комментарии

                                      Most observations only have one generic reference range. Systems MAY choose to restrict to only supplying the relevant reference range based on knowledge about the patient (e.g., specific to the patient's age, gender, weight and other factors), but this might not be possible or appropriate. Whenever more than one reference range is supplied, the differences between them SHOULD be provided in the reference range and/or age properties.

                                      Контроль0..*
                                      ТипСмотретьttp://hl7.org/fhir/StructureDefinition/Observation#Observation.referenceRange
                                      Модификаторfalse
                                      Требуется поддержкаfalse
                                      Summaryfalse
                                      Требования

                                      Knowing what values are considered "normal" can help evaluate the significance of a particular result. Need to be able to provide multiple reference ranges for different contexts.

                                      Инвариантыele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
                                      1022. Observation.component:internalStructureHeterogeneous
                                      Название разрезаinternalStructureHeterogeneous
                                      Определение

                                      Some observations have multiple component observations. These component observations are expressed as separate code value pairs that share the same attributes. Examples include systolic and diastolic component observations for blood pressure measurement and multiple component observations for genetics observations.

                                      КороткийComponent results
                                      Комментарии

                                      For a discussion on the ways Observations can be assembled in groups together see Notes below.

                                      Контроль0..1
                                      На этот элемент влияют следующие инварианты: obs-7
                                      ТипBackboneElement
                                      Модификаторfalse
                                      Требуется поддержкаtrue
                                      Summarytrue
                                      Требования

                                      Component observations share the same attributes in the Observation resource as the primary observation and are always treated a part of a single observation (they are not separable). However, the reference range for the primary observation value is not inherited by the component values and is required when appropriate for each component observation.

                                      Инвариантыele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
                                      1024. Observation.component:internalStructureHeterogeneous.id
                                      Определение

                                      Unique id for the element within a resource (for internal references). This may be any string value that does not contain spaces.

                                      КороткийUnique id for inter-element referencing
                                      Контроль0..1
                                      На этот элемент влияют следующие инварианты: ele-1
                                      Типstring
                                      Модификаторfalse
                                      Формат XMLВ формате XML это свойство представлено в качестве атрибута.
                                      Summaryfalse
                                      1026. Observation.component:internalStructureHeterogeneous.extension
                                      Определение

                                      May be used to represent additional information that is not part of the basic definition of the element. To make the use of extensions safe and managable, there is a strict set of governance applied to the definition and use of extensions. Though any implementer can define an extension, there is a set of requirements that SHALL be met as part of the definition of the extension.

                                      КороткийAdditional content defined by implementations
                                      Комментарии

                                      There can be no stigma associated with the use of extensions by any application, project, or standard - regardless of the institution or jurisdiction that uses or defines the extensions. The use of extensions is what allows the FHIR specification to retain a core level of simplicity for everyone.

                                      Контроль0..*
                                      ТипExtension
                                      Модификаторfalse
                                      Summaryfalse
                                      Альтернативные именаextensions, user content
                                      Инвариантыele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
                                      ext-1: Must have either extensions or value[x], not both (extension.exists() != value.exists())
                                      1028. Observation.component:internalStructureHeterogeneous.modifierExtension
                                      Определение

                                      May be used to represent additional information that is not part of the basic definition of the element and that modifies the understanding of the element in which it is contained and/or the understanding of the containing element's descendants. Usually modifier elements provide negation or qualification. To make the use of extensions safe and managable, there is a strict set of governance applied to the definition and use of extensions. Though any implementer can define an extension, there is a set of requirements that SHALL be met as part of the definition of the extension. Applications processing a resource are required to check for modifier extensions.

                                      Modifier extensions SHALL NOT change the meaning of any elements on Resource or DomainResource (including cannot change the meaning of modifierExtension itself).

                                      КороткийExtensions that cannot be ignored even if unrecognized
                                      Комментарии

                                      There can be no stigma associated with the use of extensions by any application, project, or standard - regardless of the institution or jurisdiction that uses or defines the extensions. The use of extensions is what allows the FHIR specification to retain a core level of simplicity for everyone.

                                      Контроль0..*
                                      ТипExtension
                                      Модификаторtrue потому что Modifier extensions are expected to modify the meaning or interpretation of the element that contains them
                                      Summarytrue
                                      Требования

                                      Modifier extensions allow for extensions that cannot be safely ignored to be clearly distinguished from the vast majority of extensions which can be safely ignored. This promotes interoperability by eliminating the need for implementers to prohibit the presence of extensions. For further information, see the definition of modifier extensions.

                                      Альтернативные именаextensions, user content, modifiers
                                      Инвариантыele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
                                      ext-1: Must have either extensions or value[x], not both (extension.exists() != value.exists())
                                      1030. Observation.component:internalStructureHeterogeneous.code
                                      Определение

                                      Describes what was observed. Sometimes this is called the observation "code".

                                      КороткийType of component observation (code / type)
                                      Комментарии

                                      All code-value and component.code-component.value pairs need to be taken into account to correctly understand the meaning of the observation.

                                      Контроль1..1
                                      На этот элемент влияют следующие инварианты: obs-7
                                      ПривязкаКоды СЛЕДУЕТ взять из ObservationCodesVS (0.12.0)
                                      (preferred to https://terminology.dhp.uz/fhir/core/ValueSet/observation-codes-vs|0.12.0)
                                      ТипCodeableConcept
                                      Модификаторfalse
                                      Требуется поддержкаtrue
                                      Summarytrue
                                      Требования

                                      Knowing what kind of observation is being made is essential to understanding the observation.

                                      Значение шаблона{
                                        "coding" : [{
                                          "system" : "https://terminology.dhp.uz/fhir/integrations/CodeSystem/screening-ultrasound-parameter-cs",
                                          "code" : "scrn-0052-00032"
                                        }]
                                      }
                                      Инвариантыele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
                                      1032. Observation.component:internalStructureHeterogeneous.value[x]
                                      Определение

                                      The information determined as a result of making the observation, if the information has a simple value.

                                      КороткийActual component result
                                      Комментарии

                                      Used when observation has a set of component observations:

                                      • An observation may have both a value (e.g. an Apgar score) and component observations (the observations from which the Apgar score was derived).
                                      • If a value is present, the datatype for this element should be determined by the code.
                                      • CodeableConcept with just a text would be used instead of a string if the field was usually coded, or if the type associated with the code defines a coded value.
                                      • Attachment is used if the observation result value is a binary file such as an image. If the observation result value is derived from the binary file (for example 'X' detected and here is the the proof in this image), the binary file may be directly represented using DocumentReference and referenced by derivedFrom.
                                      • If a value is present, the datatype for this element should be determined by the code.
                                      • CodeableConcept with just a text would be used instead of a string if the field was usually coded, or if the type associated with the code defines a coded value.
                                      • Attachment is used if the observation result value is a binary file such as an image. If the observation result value is derived from the binary file (for example 'X' detected and here is the the proof in this image), the binary file may be directly represented using DocumentReference and referenced by derivedFrom.
                                      • The usage of valueReference is restricted to the MolecularSequence resource when used as a definitional resource, not as a patient-specific finding. .
                                      • For additional guidance, see the Notes section below.
                                      Контроль1..1
                                      Типboolean
                                      [x] ЗаметкаСмотретьВыбор типов данныхдля дополнительной информации о том, как использовать [x]
                                      Модификаторfalse
                                      Примитивное значениеЭтот примитивный элемент может присутствовать или отсутствовать, или быть замененным расширением
                                      Требуется поддержкаtrue
                                      Summarytrue
                                      Требования

                                      An observation exists to have a value, though it might not if it is in error, or if it represents a group of observations.

                                      Инвариантыele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
                                      1034. Observation.component:internalStructureHeterogeneous.dataAbsentReason
                                      Определение

                                      Provides a reason why the expected value in the element Observation.component.value[x] is missing.

                                      КороткийWhy the component result is missing
                                      Комментарии

                                      "Null" or exceptional values can be represented two ways in FHIR Observations. One way is to simply include them in the value set and represent the exceptions in the value. For example, measurement values for a serology test could be "detected", "not detected", "inconclusive", or "test not done".

                                      The alternate way is to use the value element for actual observations and use the explicit dataAbsentReason element to record exceptional values. For example, the dataAbsentReason code "error" could be used when the measurement was not completed. Because of these options, use-case agreements are required to interpret general observations for exceptional values.

                                      Контроль0..1
                                      ПривязкаЕсли они не подходят, эти коды ДОЛЖНЫ быть взяты из DataAbsentReasonVS (0.12.0)
                                      (extensible to https://terminology.dhp.uz/fhir/core/ValueSet/data-absent-reason-vs|0.12.0)
                                      ТипCodeableConcept
                                      Модификаторfalse
                                      Требуется поддержкаfalse
                                      Summaryfalse
                                      Требования

                                      For many results it is necessary to handle exceptional values in measurements.

                                      Инвариантыele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
                                      1036. Observation.component:internalStructureHeterogeneous.interpretation
                                      Определение

                                      A categorical assessment of an observation value. For example, high, low, normal.

                                      КороткийHigh, low, normal, etc
                                      Комментарии

                                      Historically used for laboratory results (known as 'abnormal flag' ), its use extends to other use cases where coded interpretations are relevant. Often reported as one or more simple compact codes this element is often placed adjacent to the result value in reports and flow sheets to signal the meaning/normalcy status of the result.

                                      Контроль0..*
                                      ПривязкаЕсли они не подходят, эти коды ДОЛЖНЫ быть взяты из ObservationInterpretationVS (0.12.0)
                                      (extensible to https://terminology.dhp.uz/fhir/core/ValueSet/observation-interpretation-vs|0.12.0)
                                      ТипCodeableConcept
                                      Модификаторfalse
                                      Требуется поддержкаfalse
                                      Summaryfalse
                                      Требования

                                      For some results, particularly numeric results, an interpretation is necessary to fully understand the significance of a result.

                                      Альтернативные именаAbnormal Flag
                                      Инвариантыele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
                                      1038. Observation.component:internalStructureHeterogeneous.referenceRange
                                      Определение

                                      Guidance on how to interpret the value by comparison to a normal or recommended range.

                                      КороткийProvides guide for interpretation of component result
                                      Комментарии

                                      Most observations only have one generic reference range. Systems MAY choose to restrict to only supplying the relevant reference range based on knowledge about the patient (e.g., specific to the patient's age, gender, weight and other factors), but this might not be possible or appropriate. Whenever more than one reference range is supplied, the differences between them SHOULD be provided in the reference range and/or age properties.

                                      Контроль0..*
                                      ТипСмотретьttp://hl7.org/fhir/StructureDefinition/Observation#Observation.referenceRange
                                      Модификаторfalse
                                      Требуется поддержкаfalse
                                      Summaryfalse
                                      Требования

                                      Knowing what values are considered "normal" can help evaluate the significance of a particular result. Need to be able to provide multiple reference ranges for different contexts.

                                      Инвариантыele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
                                      1040. Observation.component:internalStructureCysticInclusions
                                      Название разрезаinternalStructureCysticInclusions
                                      Определение

                                      Some observations have multiple component observations. These component observations are expressed as separate code value pairs that share the same attributes. Examples include systolic and diastolic component observations for blood pressure measurement and multiple component observations for genetics observations.

                                      КороткийComponent results
                                      Комментарии

                                      For a discussion on the ways Observations can be assembled in groups together see Notes below.

                                      Контроль0..1
                                      На этот элемент влияют следующие инварианты: obs-7
                                      ТипBackboneElement
                                      Модификаторfalse
                                      Требуется поддержкаtrue
                                      Summarytrue
                                      Требования

                                      Component observations share the same attributes in the Observation resource as the primary observation and are always treated a part of a single observation (they are not separable). However, the reference range for the primary observation value is not inherited by the component values and is required when appropriate for each component observation.

                                      Инвариантыele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
                                      1042. Observation.component:internalStructureCysticInclusions.id
                                      Определение

                                      Unique id for the element within a resource (for internal references). This may be any string value that does not contain spaces.

                                      КороткийUnique id for inter-element referencing
                                      Контроль0..1
                                      На этот элемент влияют следующие инварианты: ele-1
                                      Типstring
                                      Модификаторfalse
                                      Формат XMLВ формате XML это свойство представлено в качестве атрибута.
                                      Summaryfalse
                                      1044. Observation.component:internalStructureCysticInclusions.extension
                                      Определение

                                      May be used to represent additional information that is not part of the basic definition of the element. To make the use of extensions safe and managable, there is a strict set of governance applied to the definition and use of extensions. Though any implementer can define an extension, there is a set of requirements that SHALL be met as part of the definition of the extension.

                                      КороткийAdditional content defined by implementations
                                      Комментарии

                                      There can be no stigma associated with the use of extensions by any application, project, or standard - regardless of the institution or jurisdiction that uses or defines the extensions. The use of extensions is what allows the FHIR specification to retain a core level of simplicity for everyone.

                                      Контроль0..*
                                      ТипExtension
                                      Модификаторfalse
                                      Summaryfalse
                                      Альтернативные именаextensions, user content
                                      Инвариантыele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
                                      ext-1: Must have either extensions or value[x], not both (extension.exists() != value.exists())
                                      1046. Observation.component:internalStructureCysticInclusions.modifierExtension
                                      Определение

                                      May be used to represent additional information that is not part of the basic definition of the element and that modifies the understanding of the element in which it is contained and/or the understanding of the containing element's descendants. Usually modifier elements provide negation or qualification. To make the use of extensions safe and managable, there is a strict set of governance applied to the definition and use of extensions. Though any implementer can define an extension, there is a set of requirements that SHALL be met as part of the definition of the extension. Applications processing a resource are required to check for modifier extensions.

                                      Modifier extensions SHALL NOT change the meaning of any elements on Resource or DomainResource (including cannot change the meaning of modifierExtension itself).

                                      КороткийExtensions that cannot be ignored even if unrecognized
                                      Комментарии

                                      There can be no stigma associated with the use of extensions by any application, project, or standard - regardless of the institution or jurisdiction that uses or defines the extensions. The use of extensions is what allows the FHIR specification to retain a core level of simplicity for everyone.

                                      Контроль0..*
                                      ТипExtension
                                      Модификаторtrue потому что Modifier extensions are expected to modify the meaning or interpretation of the element that contains them
                                      Summarytrue
                                      Требования

                                      Modifier extensions allow for extensions that cannot be safely ignored to be clearly distinguished from the vast majority of extensions which can be safely ignored. This promotes interoperability by eliminating the need for implementers to prohibit the presence of extensions. For further information, see the definition of modifier extensions.

                                      Альтернативные именаextensions, user content, modifiers
                                      Инвариантыele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
                                      ext-1: Must have either extensions or value[x], not both (extension.exists() != value.exists())
                                      1048. Observation.component:internalStructureCysticInclusions.code
                                      Определение

                                      Describes what was observed. Sometimes this is called the observation "code".

                                      КороткийType of component observation (code / type)
                                      Комментарии

                                      All code-value and component.code-component.value pairs need to be taken into account to correctly understand the meaning of the observation.

                                      Контроль1..1
                                      На этот элемент влияют следующие инварианты: obs-7
                                      ПривязкаКоды СЛЕДУЕТ взять из ObservationCodesVS (0.12.0)
                                      (preferred to https://terminology.dhp.uz/fhir/core/ValueSet/observation-codes-vs|0.12.0)
                                      ТипCodeableConcept
                                      Модификаторfalse
                                      Требуется поддержкаtrue
                                      Summarytrue
                                      Требования

                                      Knowing what kind of observation is being made is essential to understanding the observation.

                                      Значение шаблона{
                                        "coding" : [{
                                          "system" : "https://terminology.dhp.uz/fhir/integrations/CodeSystem/screening-ultrasound-parameter-cs",
                                          "code" : "scrn-0052-00033"
                                        }]
                                      }
                                      Инвариантыele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
                                      1050. Observation.component:internalStructureCysticInclusions.value[x]
                                      Определение

                                      The information determined as a result of making the observation, if the information has a simple value.

                                      КороткийActual component result
                                      Комментарии

                                      Used when observation has a set of component observations:

                                      • An observation may have both a value (e.g. an Apgar score) and component observations (the observations from which the Apgar score was derived).
                                      • If a value is present, the datatype for this element should be determined by the code.
                                      • CodeableConcept with just a text would be used instead of a string if the field was usually coded, or if the type associated with the code defines a coded value.
                                      • Attachment is used if the observation result value is a binary file such as an image. If the observation result value is derived from the binary file (for example 'X' detected and here is the the proof in this image), the binary file may be directly represented using DocumentReference and referenced by derivedFrom.
                                      • If a value is present, the datatype for this element should be determined by the code.
                                      • CodeableConcept with just a text would be used instead of a string if the field was usually coded, or if the type associated with the code defines a coded value.
                                      • Attachment is used if the observation result value is a binary file such as an image. If the observation result value is derived from the binary file (for example 'X' detected and here is the the proof in this image), the binary file may be directly represented using DocumentReference and referenced by derivedFrom.
                                      • The usage of valueReference is restricted to the MolecularSequence resource when used as a definitional resource, not as a patient-specific finding. .
                                      • For additional guidance, see the Notes section below.
                                      Контроль1..1
                                      Типboolean
                                      [x] ЗаметкаСмотретьВыбор типов данныхдля дополнительной информации о том, как использовать [x]
                                      Модификаторfalse
                                      Примитивное значениеЭтот примитивный элемент может присутствовать или отсутствовать, или быть замененным расширением
                                      Требуется поддержкаtrue
                                      Summarytrue
                                      Требования

                                      An observation exists to have a value, though it might not if it is in error, or if it represents a group of observations.

                                      Инвариантыele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
                                      1052. Observation.component:internalStructureCysticInclusions.dataAbsentReason
                                      Определение

                                      Provides a reason why the expected value in the element Observation.component.value[x] is missing.

                                      КороткийWhy the component result is missing
                                      Комментарии

                                      "Null" or exceptional values can be represented two ways in FHIR Observations. One way is to simply include them in the value set and represent the exceptions in the value. For example, measurement values for a serology test could be "detected", "not detected", "inconclusive", or "test not done".

                                      The alternate way is to use the value element for actual observations and use the explicit dataAbsentReason element to record exceptional values. For example, the dataAbsentReason code "error" could be used when the measurement was not completed. Because of these options, use-case agreements are required to interpret general observations for exceptional values.

                                      Контроль0..1
                                      ПривязкаЕсли они не подходят, эти коды ДОЛЖНЫ быть взяты из DataAbsentReasonVS (0.12.0)
                                      (extensible to https://terminology.dhp.uz/fhir/core/ValueSet/data-absent-reason-vs|0.12.0)
                                      ТипCodeableConcept
                                      Модификаторfalse
                                      Требуется поддержкаfalse
                                      Summaryfalse
                                      Требования

                                      For many results it is necessary to handle exceptional values in measurements.

                                      Инвариантыele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
                                      1054. Observation.component:internalStructureCysticInclusions.interpretation
                                      Определение

                                      A categorical assessment of an observation value. For example, high, low, normal.

                                      КороткийHigh, low, normal, etc
                                      Комментарии

                                      Historically used for laboratory results (known as 'abnormal flag' ), its use extends to other use cases where coded interpretations are relevant. Often reported as one or more simple compact codes this element is often placed adjacent to the result value in reports and flow sheets to signal the meaning/normalcy status of the result.

                                      Контроль0..*
                                      ПривязкаЕсли они не подходят, эти коды ДОЛЖНЫ быть взяты из ObservationInterpretationVS (0.12.0)
                                      (extensible to https://terminology.dhp.uz/fhir/core/ValueSet/observation-interpretation-vs|0.12.0)
                                      ТипCodeableConcept
                                      Модификаторfalse
                                      Требуется поддержкаfalse
                                      Summaryfalse
                                      Требования

                                      For some results, particularly numeric results, an interpretation is necessary to fully understand the significance of a result.

                                      Альтернативные именаAbnormal Flag
                                      Инвариантыele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
                                      1056. Observation.component:internalStructureCysticInclusions.referenceRange
                                      Определение

                                      Guidance on how to interpret the value by comparison to a normal or recommended range.

                                      КороткийProvides guide for interpretation of component result
                                      Комментарии

                                      Most observations only have one generic reference range. Systems MAY choose to restrict to only supplying the relevant reference range based on knowledge about the patient (e.g., specific to the patient's age, gender, weight and other factors), but this might not be possible or appropriate. Whenever more than one reference range is supplied, the differences between them SHOULD be provided in the reference range and/or age properties.

                                      Контроль0..*
                                      ТипСмотретьttp://hl7.org/fhir/StructureDefinition/Observation#Observation.referenceRange
                                      Модификаторfalse
                                      Требуется поддержкаfalse
                                      Summaryfalse
                                      Требования

                                      Knowing what values are considered "normal" can help evaluate the significance of a particular result. Need to be able to provide multiple reference ranges for different contexts.

                                      Инвариантыele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
                                      1058. Observation.component:internalStructureMicrocalcifications
                                      Название разрезаinternalStructureMicrocalcifications
                                      Определение

                                      Some observations have multiple component observations. These component observations are expressed as separate code value pairs that share the same attributes. Examples include systolic and diastolic component observations for blood pressure measurement and multiple component observations for genetics observations.

                                      КороткийComponent results
                                      Комментарии

                                      For a discussion on the ways Observations can be assembled in groups together see Notes below.

                                      Контроль0..1
                                      На этот элемент влияют следующие инварианты: obs-7
                                      ТипBackboneElement
                                      Модификаторfalse
                                      Требуется поддержкаtrue
                                      Summarytrue
                                      Требования

                                      Component observations share the same attributes in the Observation resource as the primary observation and are always treated a part of a single observation (they are not separable). However, the reference range for the primary observation value is not inherited by the component values and is required when appropriate for each component observation.

                                      Инвариантыele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
                                      1060. Observation.component:internalStructureMicrocalcifications.id
                                      Определение

                                      Unique id for the element within a resource (for internal references). This may be any string value that does not contain spaces.

                                      КороткийUnique id for inter-element referencing
                                      Контроль0..1
                                      На этот элемент влияют следующие инварианты: ele-1
                                      Типstring
                                      Модификаторfalse
                                      Формат XMLВ формате XML это свойство представлено в качестве атрибута.
                                      Summaryfalse
                                      1062. Observation.component:internalStructureMicrocalcifications.extension
                                      Определение

                                      May be used to represent additional information that is not part of the basic definition of the element. To make the use of extensions safe and managable, there is a strict set of governance applied to the definition and use of extensions. Though any implementer can define an extension, there is a set of requirements that SHALL be met as part of the definition of the extension.

                                      КороткийAdditional content defined by implementations
                                      Комментарии

                                      There can be no stigma associated with the use of extensions by any application, project, or standard - regardless of the institution or jurisdiction that uses or defines the extensions. The use of extensions is what allows the FHIR specification to retain a core level of simplicity for everyone.

                                      Контроль0..*
                                      ТипExtension
                                      Модификаторfalse
                                      Summaryfalse
                                      Альтернативные именаextensions, user content
                                      Инвариантыele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
                                      ext-1: Must have either extensions or value[x], not both (extension.exists() != value.exists())
                                      1064. Observation.component:internalStructureMicrocalcifications.modifierExtension
                                      Определение

                                      May be used to represent additional information that is not part of the basic definition of the element and that modifies the understanding of the element in which it is contained and/or the understanding of the containing element's descendants. Usually modifier elements provide negation or qualification. To make the use of extensions safe and managable, there is a strict set of governance applied to the definition and use of extensions. Though any implementer can define an extension, there is a set of requirements that SHALL be met as part of the definition of the extension. Applications processing a resource are required to check for modifier extensions.

                                      Modifier extensions SHALL NOT change the meaning of any elements on Resource or DomainResource (including cannot change the meaning of modifierExtension itself).

                                      КороткийExtensions that cannot be ignored even if unrecognized
                                      Комментарии

                                      There can be no stigma associated with the use of extensions by any application, project, or standard - regardless of the institution or jurisdiction that uses or defines the extensions. The use of extensions is what allows the FHIR specification to retain a core level of simplicity for everyone.

                                      Контроль0..*
                                      ТипExtension
                                      Модификаторtrue потому что Modifier extensions are expected to modify the meaning or interpretation of the element that contains them
                                      Summarytrue
                                      Требования

                                      Modifier extensions allow for extensions that cannot be safely ignored to be clearly distinguished from the vast majority of extensions which can be safely ignored. This promotes interoperability by eliminating the need for implementers to prohibit the presence of extensions. For further information, see the definition of modifier extensions.

                                      Альтернативные именаextensions, user content, modifiers
                                      Инвариантыele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
                                      ext-1: Must have either extensions or value[x], not both (extension.exists() != value.exists())
                                      1066. Observation.component:internalStructureMicrocalcifications.code
                                      Определение

                                      Describes what was observed. Sometimes this is called the observation "code".

                                      КороткийType of component observation (code / type)
                                      Комментарии

                                      All code-value and component.code-component.value pairs need to be taken into account to correctly understand the meaning of the observation.

                                      Контроль1..1
                                      На этот элемент влияют следующие инварианты: obs-7
                                      ПривязкаКоды СЛЕДУЕТ взять из ObservationCodesVS (0.12.0)
                                      (preferred to https://terminology.dhp.uz/fhir/core/ValueSet/observation-codes-vs|0.12.0)
                                      ТипCodeableConcept
                                      Модификаторfalse
                                      Требуется поддержкаtrue
                                      Summarytrue
                                      Требования

                                      Knowing what kind of observation is being made is essential to understanding the observation.

                                      Значение шаблона{
                                        "coding" : [{
                                          "system" : "https://terminology.dhp.uz/fhir/integrations/CodeSystem/screening-ultrasound-parameter-cs",
                                          "code" : "scrn-0052-00034"
                                        }]
                                      }
                                      Инвариантыele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
                                      1068. Observation.component:internalStructureMicrocalcifications.value[x]
                                      Определение

                                      The information determined as a result of making the observation, if the information has a simple value.

                                      КороткийActual component result
                                      Комментарии

                                      Used when observation has a set of component observations:

                                      • An observation may have both a value (e.g. an Apgar score) and component observations (the observations from which the Apgar score was derived).
                                      • If a value is present, the datatype for this element should be determined by the code.
                                      • CodeableConcept with just a text would be used instead of a string if the field was usually coded, or if the type associated with the code defines a coded value.
                                      • Attachment is used if the observation result value is a binary file such as an image. If the observation result value is derived from the binary file (for example 'X' detected and here is the the proof in this image), the binary file may be directly represented using DocumentReference and referenced by derivedFrom.
                                      • If a value is present, the datatype for this element should be determined by the code.
                                      • CodeableConcept with just a text would be used instead of a string if the field was usually coded, or if the type associated with the code defines a coded value.
                                      • Attachment is used if the observation result value is a binary file such as an image. If the observation result value is derived from the binary file (for example 'X' detected and here is the the proof in this image), the binary file may be directly represented using DocumentReference and referenced by derivedFrom.
                                      • The usage of valueReference is restricted to the MolecularSequence resource when used as a definitional resource, not as a patient-specific finding. .
                                      • For additional guidance, see the Notes section below.
                                      Контроль1..1
                                      Типboolean
                                      [x] ЗаметкаСмотретьВыбор типов данныхдля дополнительной информации о том, как использовать [x]
                                      Модификаторfalse
                                      Примитивное значениеЭтот примитивный элемент может присутствовать или отсутствовать, или быть замененным расширением
                                      Требуется поддержкаtrue
                                      Summarytrue
                                      Требования

                                      An observation exists to have a value, though it might not if it is in error, or if it represents a group of observations.

                                      Инвариантыele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
                                      1070. Observation.component:internalStructureMicrocalcifications.dataAbsentReason
                                      Определение

                                      Provides a reason why the expected value in the element Observation.component.value[x] is missing.

                                      КороткийWhy the component result is missing
                                      Комментарии

                                      "Null" or exceptional values can be represented two ways in FHIR Observations. One way is to simply include them in the value set and represent the exceptions in the value. For example, measurement values for a serology test could be "detected", "not detected", "inconclusive", or "test not done".

                                      The alternate way is to use the value element for actual observations and use the explicit dataAbsentReason element to record exceptional values. For example, the dataAbsentReason code "error" could be used when the measurement was not completed. Because of these options, use-case agreements are required to interpret general observations for exceptional values.

                                      Контроль0..1
                                      ПривязкаЕсли они не подходят, эти коды ДОЛЖНЫ быть взяты из DataAbsentReasonVS (0.12.0)
                                      (extensible to https://terminology.dhp.uz/fhir/core/ValueSet/data-absent-reason-vs|0.12.0)
                                      ТипCodeableConcept
                                      Модификаторfalse
                                      Требуется поддержкаfalse
                                      Summaryfalse
                                      Требования

                                      For many results it is necessary to handle exceptional values in measurements.

                                      Инвариантыele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
                                      1072. Observation.component:internalStructureMicrocalcifications.interpretation
                                      Определение

                                      A categorical assessment of an observation value. For example, high, low, normal.

                                      КороткийHigh, low, normal, etc
                                      Комментарии

                                      Historically used for laboratory results (known as 'abnormal flag' ), its use extends to other use cases where coded interpretations are relevant. Often reported as one or more simple compact codes this element is often placed adjacent to the result value in reports and flow sheets to signal the meaning/normalcy status of the result.

                                      Контроль0..*
                                      ПривязкаЕсли они не подходят, эти коды ДОЛЖНЫ быть взяты из ObservationInterpretationVS (0.12.0)
                                      (extensible to https://terminology.dhp.uz/fhir/core/ValueSet/observation-interpretation-vs|0.12.0)
                                      ТипCodeableConcept
                                      Модификаторfalse
                                      Требуется поддержкаfalse
                                      Summaryfalse
                                      Требования

                                      For some results, particularly numeric results, an interpretation is necessary to fully understand the significance of a result.

                                      Альтернативные именаAbnormal Flag
                                      Инвариантыele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
                                      1074. Observation.component:internalStructureMicrocalcifications.referenceRange
                                      Определение

                                      Guidance on how to interpret the value by comparison to a normal or recommended range.

                                      КороткийProvides guide for interpretation of component result
                                      Комментарии

                                      Most observations only have one generic reference range. Systems MAY choose to restrict to only supplying the relevant reference range based on knowledge about the patient (e.g., specific to the patient's age, gender, weight and other factors), but this might not be possible or appropriate. Whenever more than one reference range is supplied, the differences between them SHOULD be provided in the reference range and/or age properties.

                                      Контроль0..*
                                      ТипСмотретьttp://hl7.org/fhir/StructureDefinition/Observation#Observation.referenceRange
                                      Модификаторfalse
                                      Требуется поддержкаfalse
                                      Summaryfalse
                                      Требования

                                      Knowing what values are considered "normal" can help evaluate the significance of a particular result. Need to be able to provide multiple reference ranges for different contexts.

                                      Инвариантыele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
                                      1076. Observation.component:internalStructureMacrocalcifications
                                      Название разрезаinternalStructureMacrocalcifications
                                      Определение

                                      Some observations have multiple component observations. These component observations are expressed as separate code value pairs that share the same attributes. Examples include systolic and diastolic component observations for blood pressure measurement and multiple component observations for genetics observations.

                                      КороткийComponent results
                                      Комментарии

                                      For a discussion on the ways Observations can be assembled in groups together see Notes below.

                                      Контроль0..1
                                      На этот элемент влияют следующие инварианты: obs-7
                                      ТипBackboneElement
                                      Модификаторfalse
                                      Требуется поддержкаtrue
                                      Summarytrue
                                      Требования

                                      Component observations share the same attributes in the Observation resource as the primary observation and are always treated a part of a single observation (they are not separable). However, the reference range for the primary observation value is not inherited by the component values and is required when appropriate for each component observation.

                                      Инвариантыele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
                                      1078. Observation.component:internalStructureMacrocalcifications.id
                                      Определение

                                      Unique id for the element within a resource (for internal references). This may be any string value that does not contain spaces.

                                      КороткийUnique id for inter-element referencing
                                      Контроль0..1
                                      На этот элемент влияют следующие инварианты: ele-1
                                      Типstring
                                      Модификаторfalse
                                      Формат XMLВ формате XML это свойство представлено в качестве атрибута.
                                      Summaryfalse
                                      1080. Observation.component:internalStructureMacrocalcifications.extension
                                      Определение

                                      May be used to represent additional information that is not part of the basic definition of the element. To make the use of extensions safe and managable, there is a strict set of governance applied to the definition and use of extensions. Though any implementer can define an extension, there is a set of requirements that SHALL be met as part of the definition of the extension.

                                      КороткийAdditional content defined by implementations
                                      Комментарии

                                      There can be no stigma associated with the use of extensions by any application, project, or standard - regardless of the institution or jurisdiction that uses or defines the extensions. The use of extensions is what allows the FHIR specification to retain a core level of simplicity for everyone.

                                      Контроль0..*
                                      ТипExtension
                                      Модификаторfalse
                                      Summaryfalse
                                      Альтернативные именаextensions, user content
                                      Инвариантыele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
                                      ext-1: Must have either extensions or value[x], not both (extension.exists() != value.exists())
                                      1082. Observation.component:internalStructureMacrocalcifications.modifierExtension
                                      Определение

                                      May be used to represent additional information that is not part of the basic definition of the element and that modifies the understanding of the element in which it is contained and/or the understanding of the containing element's descendants. Usually modifier elements provide negation or qualification. To make the use of extensions safe and managable, there is a strict set of governance applied to the definition and use of extensions. Though any implementer can define an extension, there is a set of requirements that SHALL be met as part of the definition of the extension. Applications processing a resource are required to check for modifier extensions.

                                      Modifier extensions SHALL NOT change the meaning of any elements on Resource or DomainResource (including cannot change the meaning of modifierExtension itself).

                                      КороткийExtensions that cannot be ignored even if unrecognized
                                      Комментарии

                                      There can be no stigma associated with the use of extensions by any application, project, or standard - regardless of the institution or jurisdiction that uses or defines the extensions. The use of extensions is what allows the FHIR specification to retain a core level of simplicity for everyone.

                                      Контроль0..*
                                      ТипExtension
                                      Модификаторtrue потому что Modifier extensions are expected to modify the meaning or interpretation of the element that contains them
                                      Summarytrue
                                      Требования

                                      Modifier extensions allow for extensions that cannot be safely ignored to be clearly distinguished from the vast majority of extensions which can be safely ignored. This promotes interoperability by eliminating the need for implementers to prohibit the presence of extensions. For further information, see the definition of modifier extensions.

                                      Альтернативные именаextensions, user content, modifiers
                                      Инвариантыele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
                                      ext-1: Must have either extensions or value[x], not both (extension.exists() != value.exists())
                                      1084. Observation.component:internalStructureMacrocalcifications.code
                                      Определение

                                      Describes what was observed. Sometimes this is called the observation "code".

                                      КороткийType of component observation (code / type)
                                      Комментарии

                                      All code-value and component.code-component.value pairs need to be taken into account to correctly understand the meaning of the observation.

                                      Контроль1..1
                                      На этот элемент влияют следующие инварианты: obs-7
                                      ПривязкаКоды СЛЕДУЕТ взять из ObservationCodesVS (0.12.0)
                                      (preferred to https://terminology.dhp.uz/fhir/core/ValueSet/observation-codes-vs|0.12.0)
                                      ТипCodeableConcept
                                      Модификаторfalse
                                      Требуется поддержкаtrue
                                      Summarytrue
                                      Требования

                                      Knowing what kind of observation is being made is essential to understanding the observation.

                                      Значение шаблона{
                                        "coding" : [{
                                          "system" : "https://terminology.dhp.uz/fhir/integrations/CodeSystem/screening-ultrasound-parameter-cs",
                                          "code" : "scrn-0052-00035"
                                        }]
                                      }
                                      Инвариантыele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
                                      1086. Observation.component:internalStructureMacrocalcifications.value[x]
                                      Определение

                                      The information determined as a result of making the observation, if the information has a simple value.

                                      КороткийActual component result
                                      Комментарии

                                      Used when observation has a set of component observations:

                                      • An observation may have both a value (e.g. an Apgar score) and component observations (the observations from which the Apgar score was derived).
                                      • If a value is present, the datatype for this element should be determined by the code.
                                      • CodeableConcept with just a text would be used instead of a string if the field was usually coded, or if the type associated with the code defines a coded value.
                                      • Attachment is used if the observation result value is a binary file such as an image. If the observation result value is derived from the binary file (for example 'X' detected and here is the the proof in this image), the binary file may be directly represented using DocumentReference and referenced by derivedFrom.
                                      • If a value is present, the datatype for this element should be determined by the code.
                                      • CodeableConcept with just a text would be used instead of a string if the field was usually coded, or if the type associated with the code defines a coded value.
                                      • Attachment is used if the observation result value is a binary file such as an image. If the observation result value is derived from the binary file (for example 'X' detected and here is the the proof in this image), the binary file may be directly represented using DocumentReference and referenced by derivedFrom.
                                      • The usage of valueReference is restricted to the MolecularSequence resource when used as a definitional resource, not as a patient-specific finding. .
                                      • For additional guidance, see the Notes section below.
                                      Контроль1..1
                                      Типboolean
                                      [x] ЗаметкаСмотретьВыбор типов данныхдля дополнительной информации о том, как использовать [x]
                                      Модификаторfalse
                                      Примитивное значениеЭтот примитивный элемент может присутствовать или отсутствовать, или быть замененным расширением
                                      Требуется поддержкаtrue
                                      Summarytrue
                                      Требования

                                      An observation exists to have a value, though it might not if it is in error, or if it represents a group of observations.

                                      Инвариантыele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
                                      1088. Observation.component:internalStructureMacrocalcifications.dataAbsentReason
                                      Определение

                                      Provides a reason why the expected value in the element Observation.component.value[x] is missing.

                                      КороткийWhy the component result is missing
                                      Комментарии

                                      "Null" or exceptional values can be represented two ways in FHIR Observations. One way is to simply include them in the value set and represent the exceptions in the value. For example, measurement values for a serology test could be "detected", "not detected", "inconclusive", or "test not done".

                                      The alternate way is to use the value element for actual observations and use the explicit dataAbsentReason element to record exceptional values. For example, the dataAbsentReason code "error" could be used when the measurement was not completed. Because of these options, use-case agreements are required to interpret general observations for exceptional values.

                                      Контроль0..1
                                      ПривязкаЕсли они не подходят, эти коды ДОЛЖНЫ быть взяты из DataAbsentReasonVS (0.12.0)
                                      (extensible to https://terminology.dhp.uz/fhir/core/ValueSet/data-absent-reason-vs|0.12.0)
                                      ТипCodeableConcept
                                      Модификаторfalse
                                      Требуется поддержкаfalse
                                      Summaryfalse
                                      Требования

                                      For many results it is necessary to handle exceptional values in measurements.

                                      Инвариантыele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
                                      1090. Observation.component:internalStructureMacrocalcifications.interpretation
                                      Определение

                                      A categorical assessment of an observation value. For example, high, low, normal.

                                      КороткийHigh, low, normal, etc
                                      Комментарии

                                      Historically used for laboratory results (known as 'abnormal flag' ), its use extends to other use cases where coded interpretations are relevant. Often reported as one or more simple compact codes this element is often placed adjacent to the result value in reports and flow sheets to signal the meaning/normalcy status of the result.

                                      Контроль0..*
                                      ПривязкаЕсли они не подходят, эти коды ДОЛЖНЫ быть взяты из ObservationInterpretationVS (0.12.0)
                                      (extensible to https://terminology.dhp.uz/fhir/core/ValueSet/observation-interpretation-vs|0.12.0)
                                      ТипCodeableConcept
                                      Модификаторfalse
                                      Требуется поддержкаfalse
                                      Summaryfalse
                                      Требования

                                      For some results, particularly numeric results, an interpretation is necessary to fully understand the significance of a result.

                                      Альтернативные именаAbnormal Flag
                                      Инвариантыele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
                                      1092. Observation.component:internalStructureMacrocalcifications.referenceRange
                                      Определение

                                      Guidance on how to interpret the value by comparison to a normal or recommended range.

                                      КороткийProvides guide for interpretation of component result
                                      Комментарии

                                      Most observations only have one generic reference range. Systems MAY choose to restrict to only supplying the relevant reference range based on knowledge about the patient (e.g., specific to the patient's age, gender, weight and other factors), but this might not be possible or appropriate. Whenever more than one reference range is supplied, the differences between them SHOULD be provided in the reference range and/or age properties.

                                      Контроль0..*
                                      ТипСмотретьttp://hl7.org/fhir/StructureDefinition/Observation#Observation.referenceRange
                                      Модификаторfalse
                                      Требуется поддержкаfalse
                                      Summaryfalse
                                      Требования

                                      Knowing what values are considered "normal" can help evaluate the significance of a particular result. Need to be able to provide multiple reference ranges for different contexts.

                                      Инвариантыele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))